• Title/Summary/Keyword: underground part environment

Search Result 76, Processing Time 0.025 seconds

Reconsideration of Waterproofing and Rootproofing to keep Durable Safety of Concrete Structure in the Greening System (콘크리트 구조물 기반 녹화 공사에 있어서 콘크리트의 내구안전성 확보를 위한 방수 및 방근 기술의 제고)

  • Oh, Sang-Keun;Kim, Hyeon-Soo;Kim, Young-Geun;Kwon, Shi-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.927-930
    • /
    • 2008
  • Recently, the scale and form of the construction promoting in government and private organization have large scaled town. The underground area of whole town are used for every facilities, and most of concrete area are used for greening part for friendly environment construction. This greening part for concrete area have good point such as being amendment and various economical effect and improvement for environmental problem, moreover, the amount of greening part become great increased. For this factor, we have to newly consider to keep durable safety for concrete structure, therefore, we suggest that how to keep structural safety of greening area on the concrete.

  • PDF

Distribution of hazardous heavy metals in commercial herbal medicines classified by plant parts used in seoul (서울지역 유통한약재의 약용부위에 따른 유해중금속 분포)

  • Kim, Donggyu;Kim, Bogsoon;Han, Eunjung;Han, Changho;Kim, Oukhee;Choi, Byunghyun;Hwang, Insook;Chae, Youngzoo;Kim, Minyoung;Park, Seungkook
    • Analytical Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.504-513
    • /
    • 2009
  • In this study, the safety of commercial herbal medicines was evaluated by determining concentration of hazardous heavy metals. 3,152 samples (244 types) purchased by individual packing unit from market in Seoul, were analyzed using ICP-MS and mercury analyzer. As a result, the content (mg $kg^{-1}$) of Pb was higher in the above-ground part (0.92) than underground part (0.43). But in case of As and Cd contents, there is slightly higher in the underground-parts (0.26, 0.13) than the above-ground parts (0.18, 0.08). There were many herbal medicines exceeding regulatory limits of Cd comparing with other metals. The levels of Hg seemed to be different between above-ground part(0.009) and underground part (0.008) but there was no sample exceeding tolerance limits. In the comparison of imported samples with domestic herbal medicines, it was shown that Pb, As, and Hg were measured highly in the imported ones, Cd was not significantly different (t-test, p<0.05). The significant correlation was observed between Pb and As (r=0.386, p<0.01) but there was no difference in other parts. The heavy metal contamination of herbal medicines measured in total amount of respective heavy metals (mg $kg^{-1}$) was high in Flos (6.241) and Caulis (2.238), and decreased in the order of Cortex (1.634), Herba (1.154), Perithecium (0.861), Rhizoma (0.828), Radix (0.825), Fructus (0.475), and was low in Semen (0.422) (ANOVA-test, p<0.05).

Study on Seismic Evaluation of Racking Response of Underground Utility Tunnels with a Rectangular Cross Section in Korea (국내 박스형 공동구의 횡방향 지진 변위응답 평가에 대한 고찰)

  • Kim, Dae-Hwan;Lim, Youngwoo;Chung, Yon Ha ;Lee, Hyerin
    • Journal of the Korean Geotechnical Society
    • /
    • v.38 no.12
    • /
    • pp.29-43
    • /
    • 2022
  • Various underground facilities are being constructed to improve the urban environment. Therefore, it is more necessary than ever to reasonably evaluate the seismic response of underground utility tunnels, playing a significant part in urban infrastructure. In this study, the major features and differences of two types of existing pseudo-static analysis methods are reviewed. Each method uses a simplified 2D frame model to represent the seismic behavior of underground structures. Applying each method to a one-barrel rectangular utility tunnel in Korea, the suitability in predicting seismic responses, especially the racking deformation of the tunnel, is examined. In addition, several precautions and suggestions are provided in this study against the inattentive application of the methods to seismic evaluation of underground structures.

Evaluation of Chemical Resistance Performance of Synthetic Rubber and Cement Based Injection Repair Materials Used in Underground Concrete Structures (지하 콘크리트 구조물에 적용되는 합성고무계 및 시멘트계 주입형 보수재료의 화학 저항성능평가)

  • Kim, Soo-Yeon;Lee, Yeon-Sil;Song, Je-Young;Kim, Byoungil;Oh, Sang-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.5
    • /
    • pp.148-155
    • /
    • 2017
  • In this study, by using the international standards ISO TS 16774, Part 2 Test method for chemical resistance as a quality control method of injection type repair material used for leakage crack of underground concrete structure, the performance requirement against of chemical environment of underground concrete structures for repair materials was tested. For this testing 3 types for each of the 2 classes of repair materials(synthetic rubber, cement), with a total of 9 types repair materials, were selected and examined. As a result, the test results showed that the smallest performance deterioration by the change in the mass was with the synthetic rubber(RG) type as opposed to the cement type system, showing that the synthetic rubber type had the strongest relative resistance to chemical exposure. Furthermore, it is necessary to investigate the material with high resistance to chemical substances and to examine the material which can increase resistance to sodium hydroxide and sodium chloride in cement system. These results can be used as a basic index for the selection of repair materials with the strongest resistance to chemical environment found in concrete structures. In addition, it is expected that the test results derived in this study can be used as reference data that can be reflected in the quality improvement of the maintenance material to be developed later.

Fault Reactivation Modeling Using Coupled TOUGH2 and FLAC3D Interface Model: DECOVALEX-2019 Task B (TOUGH2-FLAC3D Interface 모델을 통한 단층 재활성 모델링: DECOVALEX-2019 Task B)

  • Park, Jung-Wook;Park, Eui-Seob;Lee, Changsoo
    • Tunnel and Underground Space
    • /
    • v.30 no.4
    • /
    • pp.335-358
    • /
    • 2020
  • We present a numerical model to simulate coupled hydro-mechanical behavior of fault using TOUGH-FLAC simulator. This study aims to develop a numerical method to estimate fluid injection-induced fault reactivation in low permeability rock and to access the relevant hydro-mechanical stability in rock as part of DECOVALEX-2019 Task B. A coupled fluid flow and mechanical interface model to explicitly represent a fault was suggested and validated from the applications to benchmark simulations and the field experiment at Mont Terri underground laboratory in Switzerland. The pressure build-up, hydraulic aperture evolution, displacement, and stress responses matched those obtained at the site, which indicates the capability of the model to appropriately capture the hydro-mechanical processes in rock fault.

Comparative Analysis of Substrate Wet Surface Adhesion and Substrate Movement Response Performance Testing Methods for Injection Type Repair Materials Used in Leakage Cracks of Concrete Structure in Underground Environment (지하 습윤 환경에서 콘크리트 구조물 균열 누수에 사용되는 주입형 보수재료의 부착 성능과 거동 대응 성능 평가의 상관성 분석 연구)

  • Kim, Soo-Yeon;Oh, Kyu Hwan;Oh, Snag-Keun
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.9
    • /
    • pp.19-26
    • /
    • 2018
  • The focus of this study was centered around 15 common injection type water leakage repair materials (3 different types for each; synthetic polymer, cementitious, acrylic, epoxy, urethane) used in concrete structures of Korea and analyzing their wet surface adhesion performance in accordance to the ISO TS 16774 Test Method for Repair Materials for Water-leakage Cracks in Underground Concrete Structures, Part 4: Test Method for Adhesion on Wet Concrete Surface, and the results of this study was taken to be place under a comparative analysis with the results of the preceeding study on response to substrate movement performance study. The results of this comparative study showed that other than 1 specimen of 1 type of the acrylic and 3 specimens of 1 type of the synthetic polymer type materials, all of the 93% of the specimens used in this study showed stable adhesion on wet substrate surface, and we were able to determine that materials that have proper response properties against substrate movement are highly flexible and have high adhesion properties, but their adhesion properties on wet substrate would change based on their viscosity.

Simplification Method for Lightweighting of Underground Geospatial Objects in a Mobile Environment (모바일 환경에서 지하공간객체의 경량화를 위한 단순화 방법)

  • Jong-Hoon Kim;Yong-Tae Kim;Hoon-Joon Kouh
    • Journal of Industrial Convergence
    • /
    • v.20 no.12
    • /
    • pp.195-202
    • /
    • 2022
  • Underground Geospatial Information Map Management System(UGIMMS) integrates various underground facilities in the underground space into 3D mesh data, and supports to check the 3D image and location of the underground facilities in the mobile app. However, there is a problem that it takes a long time to run in the app because various underground facilities can exist in some areas executed by the app and can be seen layer by layer. In this paper, we propose a deep learning-based K-means vertex clustering algorithm as a method to reduce the execution time in the app by reducing the size of the data by reducing the number of vertices in the 3D mesh data within the range that does not cause a problem in visibility. First, our proposed method obtains refined vertex feature information through a deep learning encoder-decoder based model. And second, the method was simplified by grouping similar vertices through K-means vertex clustering using feature information. As a result of the experiment, when the vertices of various underground facilities were reduced by 30% with the proposed method, the 3D image model was slightly deformed, but there was no missing part, so there was no problem in checking it in the app.

An Experimental Study on the Evaluation of Physical Properties of Planting Porous Concrete using Industrial By-products. (산업부산물을 이용한 식생용 포러스콘크리트의 물성평가에 관한 실험적 연구)

  • Park, Seung-Bum;Lee, Taek-Woo;Kwon, Hyuk-Joon;Lee, Bong-Chun;Lee, Jun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.929-934
    • /
    • 2001
  • As the notion of environment protection changes throughout the world, construction engineers, as part of the effort to resolve environmental problems, have been actively doing research on environmental friendly porous concrete using large and non-uniform aggregate. Concrete having a great deal of continuous porosity enable water and air to pass freely through firmly hardened material, allowing necessary nutrients to reach roots of vegetation, thereby sustaining them. It is possible to prevent the exhaustion of natural resources by recycling waste concrete and industrial by-products, to reduce damage caused by the destruction of nature through effective management of natural resources, to preserve the natural environment and vegetation in urban areas by activating the soil, protecting the underground ecology system, and growing garden plants through the application of environmentally friendly concrete.

  • PDF

Studies on Nutri-irrigation Culture for Developing Farm-land Resources -2. Effect of Calcium & Cation Level on the Growth and Root Environment of Radish (관비농법(灌肥農法)에 의한 농지자원개발(農地資源開發)에 관한 연구(硏究) -2. 「칼슘」 및 양(陽) 「이온」 공급수준이 이십일(二十日)무의 생육(生育)과 근권환경(根圈環境)에 미치는 영향(影響)을 중심(中心)으로)

  • Kim, Yong Chull;Kim, In Ja
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.4 no.1
    • /
    • pp.41-48
    • /
    • 1971
  • For increasing Productivity of Nutri-irrigation culture used liquified fertilizer in sandy land, the effect of Ca etc. on growth and roat system of crop (radish) was studied. Results are as follows. 1) High level of Ca in irrigated nutrient solution promoted growth of radish, especially, growth of underground part and increased yield on sand media than low level of Ca. 2) High level of cation promoted also growth of radish compared with control though less than high level of Ca do. 3) Promoted growth in high level of Ca and cation acompanied larger attachment of sand grain to root system making good condition for absorption. 4) Higher content of Ca in fibrous roots and attached sand grains compared with thickend root and other sand media (especially, in higher level of Ca), suggest a specific roll of Ca on the in teraction between roots and media constituting a root environment for productivity. 5) The content of Ca, Mg, Mn, in tops are manifestly higher than underground part while no dislinct differences are found between tops and underground parts in N.P.K.

  • PDF

Indoor and Outdoor $NO_2$ Concentration at Subway Station and Personal $NO_2$ Exposure of Subway Station Workers (지하철역사의 이산화질소 농도와 역무원의 이산화질소 개인폭로량)

  • 손부순;장봉기;박종안;김윤신
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.4
    • /
    • pp.134-141
    • /
    • 2000
  • The person' spending time in underground s[aces within indoor environment show a tendency to increase every year, but in Korea, levels and sources of pollutant in underground spaces have not been well-characterized. Therefore, as part or a larger indoor environmental study, conducted at subway station in Seoul, nitrogen dioxide was measured using passive samplers in 16 subway stations, 2 tunnels and 70 workers of subway station. The mean concentrations of nitrogen dioxide in subway stations were $27.87{\pm}7.15$ ppb at station office, $35.76{\pm}8.35$ ppb at platform, $52.60{\pm}13.04$ ppb at outdoor, respectively, and the Indoor/Outdoor ratio were 0.49~0.93. The mean concentrations of nitrogen dioxide in tunnels were $44.91{\pm}4.67$ ppb in Chunggye-Nowon tunnel with a single track, $42.55{\pm}3.33$ ppb in Mokkol-Taenung tunnel with double track, respectively, and as a result of t-test, a single track levels were higher than double track levels(p<0.05). The mean personal exposure of the subject of station workers was $29.40{\pm}9.75$ ppb.

  • PDF