• 제목/요약/키워드: underground development

검색결과 1,084건 처리시간 0.031초

온실(溫室) 난방(暖房)을 위한 태양열(太陽熱)-지하(地下) 잠열(潛熱) 축열(蓄熱) 시스템 개발(開發) (Development of Solar Energy-Underground Latent Heat Storage System for Greenhouse Heating)

  • 송현갑;류영선
    • Journal of Biosystems Engineering
    • /
    • 제19권3호
    • /
    • pp.211-221
    • /
    • 1994
  • In this study, to maximize the solar energy utilization for greenhouse heating during the winter season, solar energy-underground latent heat storage system was constructed, and the thermal performance of the system has been analyzed to obtain the basic data for realization of greenhouse solar heating system. The results are summarized as follows. 1. $Na_2SO_4{\cdot}10H_20$ was selected as a latent heat storage material, its physical properties were stabilized and the phase change temperature was controlled at $13{\sim}15^{\circ}C$. 2. Solar radiation of winter season was the lowest value in December, and Jinju area was the highest and the lowest value was shown in Jeju area. 3. The minimum inner air temperature of greenhouse with latent heat storage system(LHSS) was $7.0{\sim}7.5^{\circ}C$ higher than that of greenhouse without LHSS and was $7.0{\sim}11.2^{\circ}C$ higher than the minimum ambient air temperature. 4. Greenhouse heating effect of latent heat storage system was getting higher according to the increase of solar radiation and was not concerned with the variation of minimum ambient air temperature. 5. The relative humidity of greenhouse with latent heat storage system was varied from 50 to 85%, but that of greenhouse without LHSS was varied from 30 to 93%. 6. The heating cost of greenhouse with solar energy-latent heat storage system was about 24% of that with the kerosene heating system.

  • PDF

지하수 열원 열펌프 개발을 위한 지하수 온도의 변화 특성 연구 (A Study on the Variation of Ground Water Temperature for Development of Ground Water Source Heat Pump)

  • 남현규;김영일;서정아;신영기
    • 한국지열·수열에너지학회논문집
    • /
    • 제1권2호
    • /
    • pp.1-6
    • /
    • 2005
  • Ground water source heat pumps are clean, energy-efficient and environment-friendly systems for cooling and heating. Although the initial cost of ground water source heat pump system is higher than that of air source, it is now widely accepted as an economical system since the installation cost can be returned within a short period of time due to its high efficiency. In a ground water source heat pump system, the variation of the ground water temperature is an important factor that influences the system performance. In this study, variation of the ground water temperature of a single well system is studied experimentally for various operating conditions. When ground water flow exists in the underground, the returned water exchanges heat efficiently with the ground and the temperature of the ground water remains nearly constant. Hence the short circuit problem is minimized. If an active flow of ground water flow exists in the underground, a singe well heat pumps system will be free of short circuit problem and can operate with high performance.

  • PDF

230kV XLPE 케이블 및 부속재 인증시험 완료 (DEVELOPMENT OF 230kV XLPE CABLE & ACCESSORY)

  • 권병일;남정세;오응종;김기영;최봉남;윤덕환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2268-2270
    • /
    • 1999
  • The underground transmission line have been consistently developed to increase its voltage level for satisfying the customer's demand through supplying the high reliability power. The underground XLPE cable and its accessories of 500kV level have been already developed internationally, but the XLPE cable have been installed 154kV level in Korea up to now. Thus, our company has developed 230kV XLPE cable and its accessory in 1998 for preparing 345kV level system in Korea and being qualified as international cable maker of developing oversea markets. In this paper, newly our developed 230kV system will be introduced using the type test result according to IEC 840 and additional specification.

  • PDF

전기물성 측정의 국내외 기술 동향 (Technical Trends of Domestic and Overseas on Electro-physical Properties Measurement)

  • 박삼규;조성준;이태종;이성곤;이상규
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.285-290
    • /
    • 2007
  • Electrical and electromagnetic methods were widely applied to survey of civil engineering, environment site assessments and maintenance of underground structures in Korea. Electro-physical properties measurements of soil and rock are necessary in order to quantitatively estimate the ground from these survey results. A few geotechnical researcher groups have been simplified measurement system of the electro-physical properties, which was intermittently operating by the necessity. Recent strong concern about $CO_2$ underground storage and development of gas hydrate projects have urged many advanced countries. The electro-physical properties estimation of the deep object stratum is very importance for basic information of these research. So, advanced countries have a high-end measurement system with high temperature(200 degrees) and pressure(300 MPa), also they have been a lot of experience and know-how on the electro-physical properties measurement.

  • PDF

홀센서 기반의 연약지반 자동 지반침하 계측시스템 개발 (Development of Automated Monitoring System for Soft Ground Settlement Based on Hole Senor)

  • 전제성;이근호;윤동구
    • 한국지반공학회논문집
    • /
    • 제28권6호
    • /
    • pp.39-52
    • /
    • 2012
  • 연약지반 계측에 있어, 원거리 측량에 의한 지표침하 측정 및 수동 방식의 층별침하 측정 방식을 탈피하고 기존 자동 침하 계측기술의 한계를 극복하고자, 디지털 홀센서를 이용한 자력감지 시스템 및 원위치 지반침하 자동 계측시스템을 개발하였다. 본 연구를 통한 개발 시스템은 지표침하와 다수 층별침하를 NX 규격의 단일 시추공내에서 동시에 측정할 수 있다. 개발 시스템의 실제 연약지반 개량현장 적용 및 기존 수동계측 결과와의 비교, 분석을 통해 그 기술검증 및 안정성을 확인할 수 있었다.

무선센서를 이용한 지하전력구의 케이블 접속함 표면온도감시시스템 개발 (A Development of Surface Temperature Monitoring System for Underground Tunnel Cable Joint using Wireless Sensor)

  • 김영일;송재주;신진호;이봉재;조선구
    • 전기학회논문지
    • /
    • 제56권11호
    • /
    • pp.1879-1884
    • /
    • 2007
  • In the electric power industry, it is important that the supply of energy must be guaranteed. Many power utilities control and supervise the transmission line to avoid power failures. In case of underground tunnel, some troubles are reported in cable joint. To stabilize the power, it is needed to monitor the cable joint. Many researches of cable joint monitoring have been going on by partial discharge measurement and temperature measurement using optical cable. These methods need much cost to install and maintain, so it is only used in critical transmission line. In this research, we use wireless sensor technology, because of its low cost and easy installation. We develop the temperature monitoring system for cable joint. Temperature sensor is installed on the surface of cable joint and sends data to server through router node using wireless network. Generally Ad hoc routing is searched in wireless network. However, in this research, we design the static linear routing mechanism, which is suitable for electric power line monitoring and analyze the life time of the sensor node by measuring the amount of the battery consumption.

275kV O.F 케이블로 부속재 인증시험 완료 (DEVELOPMENT OF 275kV OIL FILLED CABLE & ITS ACCESSORIES)

  • 권병일;남정세;오응종;김화종;최봉남;이승렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2057-2059
    • /
    • 2000
  • The underground transmission system has been internationally developing the voltage class of which increase to realizing high reliability and efficiency. Under this situation, if a company don't do much labor to elevating one's technology, the company will be hard to compete against other companies in trade. Our company has successfully developed 275kV oil-filled cable and its accessory in 1999 for Malaysia project, which was based on accumulated technological know-how, which is the highest voltage level among awarded oversea underground transmission networks in Korea. The power cable and its accessories were subjected to type approval test in accordance with IEC 60141-1 and TNB tender documents. This paper describes the main features of the type approval tests of the cable and its accessories.

  • PDF

전기방식(電氣防蝕) 적용구간의 전위 미달 원인 분석 (An analysis on the Causes of the Under-Potential in the Electric Anti-corrosion Section)

  • 이은춘;류경만;윤한봉;신강욱;홍성택;이은웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.55-57
    • /
    • 2005
  • Along with the development of the industrial society, as the transportation of water which is the indirect capital of society and petroleum, gas, etc used as energy sources is rapidly increased. the underground material is being expanded. Like this, the pipes laid under the ground not only bring the corrosion to the land circumstances to reduce the life of the pipes, but also raise the social problem of leakage accidents and the economic loss by Pin Hole. By reason of this, for the purpose of protecting the corrosion of the underground material, we are constructing and operating the electrolytic protection facilities. In case of a region of which specific resistance is high, however, we are not keeping proper protection potential(that is -850mV) to get protection effects. In this study, for the water pipes that under-voltage phenomena occur in the protection potential, we made a spot survey on the under-voltage section and normal-voltage section, compared, analyzed each of the contents and examined the under-voltage causes of the protection potential.

  • PDF

염해 환경에 있는 지하철 콘크리트 구조물의 내구성 향상 대책수립에 관한 연구 (A Study for Development of Durability of the Subway Concrete Structure exposed to Choride Environment)

  • 이무관;김은겸;김대호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1184-1189
    • /
    • 2005
  • Durability of concrete has been currently issued in the engineering societies and a large number of studies on the concrete corrosion in salty environment have been performed. The reinforcement corrosion, which is the primary reason of deterioration of the concrete structure exposed to chloride environment. is caused by the chloride ions infiltration owing to underground water seeping into the concrete. In this study. the endurance periods using the diffusion equation of the concrete specification have been evaluated on the concrete structures with different addictives for the brand new R/C subway structure exposed to seashore underground water. Furthermore. the guidance for proper use of the addictives and the reasonable thickness of concrete cover are derived for concrete mixing. From the result of the evaluation corresponding to salt damage for Inchon subway line I, the endurance periods of the ordinary Portlandcement concretes are represented as $42\~75$ years and fail to achieve the objective period of 100 years. However, the lower water-cement ratio expands the endurance periods and the blast furnace slag concrete with small quantity of the silica fume, which shows the best performance of corrosion resistance in this study, represents more than 170 years of the endurance period. Moreover, the case of use of blast furnace slag and fly ash together shows the endurance period of $134\~171$ years and it means that the result very satisfies the objective endurance period.

  • PDF

절개사면의 안정성 증가를 위한 배수시스템 개발에 관한 기초적 연구 (A Study on Drain System Development for Stability Increase of Cutting Slope)

  • 이승호
    • 한국지반환경공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.15-20
    • /
    • 2005
  • 도로 주변 절토사면 상부에 시공되는 산마루 측구는 상부로부터 흘러내리는 지표수를 원활히 배수시켜 절개면으로 유입되는 것을 방지한다. 국내의 경우 전 국토의 70%이상이 산악지로 구성되어 있어 도로 개설에 따른 절개면의 발생은 필연적이다. 여름 집중호우와 간극수압의 증가로 인하여 절개면의 불안정성은 증가된다. 그러나 절토사면 상부에 시공되어 있는 산마루측구는 품질관리의 어려움과 배수능력 부족 등의 문제점들이 있다. 따라서, 본 논문에서는 산마루 측구의 깊이와 투수계수에 따른 절토사면의 안전율 변화를 분석하였으며 적절한 측구 설치깊이를 결정하였다.

  • PDF