• Title/Summary/Keyword: underground development

Search Result 1,087, Processing Time 0.027 seconds

A Study on Risk Influence Factors of Ground Subsidence through Soil Investigation Analysis (지반조사 분석을 통한 지반함몰 위험영향인자 연구)

  • Joung, Ho Young;Lee, Gil Hwan
    • Journal of Korean Society of Disaster and Security
    • /
    • v.10 no.1
    • /
    • pp.43-46
    • /
    • 2017
  • Recently, the development of underground space is being actively carried out in the urban area by saturation, and the excavation works are mainly carried out by various excavation methods by the structures adjacent to the ground and underground excavation. During such excavation work, ground subsidence accidents are occurring due to inattention construction, lack of construction technology, and leakage of ground water. For the prevention of ground subsidence we studied the method of risk influence factors by soil investigation. Analysis of 75 sites soil investigation by U.S.C.S (Unified Soil Classification System), construction method, depth of excavation and we studied the risk influence factors with ground subsidence.

Development of Solar Energy-Underground Latent Heat Storage System for Greenhouse Heating (온실(溫室) 난방(暖房)을 위한 태양열(太陽熱)-지하(地下) 잠열(潛熱) 축열(蓄熱) 시스템 개발(開發))

  • Song, H.K.;Ryou, Y.S.
    • Journal of Biosystems Engineering
    • /
    • v.19 no.3
    • /
    • pp.211-221
    • /
    • 1994
  • In this study, to maximize the solar energy utilization for greenhouse heating during the winter season, solar energy-underground latent heat storage system was constructed, and the thermal performance of the system has been analyzed to obtain the basic data for realization of greenhouse solar heating system. The results are summarized as follows. 1. $Na_2SO_4{\cdot}10H_20$ was selected as a latent heat storage material, its physical properties were stabilized and the phase change temperature was controlled at $13{\sim}15^{\circ}C$. 2. Solar radiation of winter season was the lowest value in December, and Jinju area was the highest and the lowest value was shown in Jeju area. 3. The minimum inner air temperature of greenhouse with latent heat storage system(LHSS) was $7.0{\sim}7.5^{\circ}C$ higher than that of greenhouse without LHSS and was $7.0{\sim}11.2^{\circ}C$ higher than the minimum ambient air temperature. 4. Greenhouse heating effect of latent heat storage system was getting higher according to the increase of solar radiation and was not concerned with the variation of minimum ambient air temperature. 5. The relative humidity of greenhouse with latent heat storage system was varied from 50 to 85%, but that of greenhouse without LHSS was varied from 30 to 93%. 6. The heating cost of greenhouse with solar energy-latent heat storage system was about 24% of that with the kerosene heating system.

  • PDF

A Study on the Variation of Ground Water Temperature for Development of Ground Water Source Heat Pump (지하수 열원 열펌프 개발을 위한 지하수 온도의 변화 특성 연구)

  • Nam Hyun Kyu;Kim Youngil;Seo Joung Ah;Shin Younggy
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.1 no.2
    • /
    • pp.1-6
    • /
    • 2005
  • Ground water source heat pumps are clean, energy-efficient and environment-friendly systems for cooling and heating. Although the initial cost of ground water source heat pump system is higher than that of air source, it is now widely accepted as an economical system since the installation cost can be returned within a short period of time due to its high efficiency. In a ground water source heat pump system, the variation of the ground water temperature is an important factor that influences the system performance. In this study, variation of the ground water temperature of a single well system is studied experimentally for various operating conditions. When ground water flow exists in the underground, the returned water exchanges heat efficiently with the ground and the temperature of the ground water remains nearly constant. Hence the short circuit problem is minimized. If an active flow of ground water flow exists in the underground, a singe well heat pumps system will be free of short circuit problem and can operate with high performance.

  • PDF

DEVELOPMENT OF 230kV XLPE CABLE & ACCESSORY (230kV XLPE 케이블 및 부속재 인증시험 완료)

  • Kwon, B.I.;Nam, J.S.;Oh, E.J.;Kim, K.Y.;Choi, B.N.;Yun, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2268-2270
    • /
    • 1999
  • The underground transmission line have been consistently developed to increase its voltage level for satisfying the customer's demand through supplying the high reliability power. The underground XLPE cable and its accessories of 500kV level have been already developed internationally, but the XLPE cable have been installed 154kV level in Korea up to now. Thus, our company has developed 230kV XLPE cable and its accessory in 1998 for preparing 345kV level system in Korea and being qualified as international cable maker of developing oversea markets. In this paper, newly our developed 230kV system will be introduced using the type test result according to IEC 840 and additional specification.

  • PDF

Technical Trends of Domestic and Overseas on Electro-physical Properties Measurement (전기물성 측정의 국내외 기술 동향)

  • Park, Sam-Gyu;Cho, Seong-Jun;Lee, Tae-Jong;Lee, Seong-Kon;Lee, Sang-Kyu
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.285-290
    • /
    • 2007
  • Electrical and electromagnetic methods were widely applied to survey of civil engineering, environment site assessments and maintenance of underground structures in Korea. Electro-physical properties measurements of soil and rock are necessary in order to quantitatively estimate the ground from these survey results. A few geotechnical researcher groups have been simplified measurement system of the electro-physical properties, which was intermittently operating by the necessity. Recent strong concern about $CO_2$ underground storage and development of gas hydrate projects have urged many advanced countries. The electro-physical properties estimation of the deep object stratum is very importance for basic information of these research. So, advanced countries have a high-end measurement system with high temperature(200 degrees) and pressure(300 MPa), also they have been a lot of experience and know-how on the electro-physical properties measurement.

  • PDF

Development of Automated Monitoring System for Soft Ground Settlement Based on Hole Senor (홀센서 기반의 연약지반 자동 지반침하 계측시스템 개발)

  • Jeon, Je-Sung;Lee, Keun-Ho;Yoon, Dong-Gu
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.6
    • /
    • pp.39-52
    • /
    • 2012
  • Magnetic sensing system and automated monitoring system based on digital hall sensor for ground settlement are developed to change traditional method for monitoring surface settlement and underground settlement by manual type and to overcome technical limits of existing automated settlement monitoring system. It's possible to monitor surface settlement and underground settlement with multi-points at the same time in a single hole with NX size. It was possible to verify technical confidence and stability by several case studies of soft ground improvement project.

A Development of Surface Temperature Monitoring System for Underground Tunnel Cable Joint using Wireless Sensor (무선센서를 이용한 지하전력구의 케이블 접속함 표면온도감시시스템 개발)

  • Kim, Young-Il;Song, Jae-Ju;Shin, Jin-Ho;Yi, Bong-Jae;Cho, Seon-Ku
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.11
    • /
    • pp.1879-1884
    • /
    • 2007
  • In the electric power industry, it is important that the supply of energy must be guaranteed. Many power utilities control and supervise the transmission line to avoid power failures. In case of underground tunnel, some troubles are reported in cable joint. To stabilize the power, it is needed to monitor the cable joint. Many researches of cable joint monitoring have been going on by partial discharge measurement and temperature measurement using optical cable. These methods need much cost to install and maintain, so it is only used in critical transmission line. In this research, we use wireless sensor technology, because of its low cost and easy installation. We develop the temperature monitoring system for cable joint. Temperature sensor is installed on the surface of cable joint and sends data to server through router node using wireless network. Generally Ad hoc routing is searched in wireless network. However, in this research, we design the static linear routing mechanism, which is suitable for electric power line monitoring and analyze the life time of the sensor node by measuring the amount of the battery consumption.

DEVELOPMENT OF 275kV OIL FILLED CABLE & ITS ACCESSORIES (275kV O.F 케이블로 부속재 인증시험 완료)

  • Kwon, B.I.;Nam, J.S.;Oh, E.J.;Kim, H.J.;Choi, B.N.;Lee, S.R.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07c
    • /
    • pp.2057-2059
    • /
    • 2000
  • The underground transmission system has been internationally developing the voltage class of which increase to realizing high reliability and efficiency. Under this situation, if a company don't do much labor to elevating one's technology, the company will be hard to compete against other companies in trade. Our company has successfully developed 275kV oil-filled cable and its accessory in 1999 for Malaysia project, which was based on accumulated technological know-how, which is the highest voltage level among awarded oversea underground transmission networks in Korea. The power cable and its accessories were subjected to type approval test in accordance with IEC 60141-1 and TNB tender documents. This paper describes the main features of the type approval tests of the cable and its accessories.

  • PDF

An analysis on the Causes of the Under-Potential in the Electric Anti-corrosion Section (전기방식(電氣防蝕) 적용구간의 전위 미달 원인 분석)

  • Lee, Eun-Chun;Ryu, Keong-Man;Yoon, Han-Bong;Shin, Gang-Wook;Hong, Sung-Taek;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.55-57
    • /
    • 2005
  • Along with the development of the industrial society, as the transportation of water which is the indirect capital of society and petroleum, gas, etc used as energy sources is rapidly increased. the underground material is being expanded. Like this, the pipes laid under the ground not only bring the corrosion to the land circumstances to reduce the life of the pipes, but also raise the social problem of leakage accidents and the economic loss by Pin Hole. By reason of this, for the purpose of protecting the corrosion of the underground material, we are constructing and operating the electrolytic protection facilities. In case of a region of which specific resistance is high, however, we are not keeping proper protection potential(that is -850mV) to get protection effects. In this study, for the water pipes that under-voltage phenomena occur in the protection potential, we made a spot survey on the under-voltage section and normal-voltage section, compared, analyzed each of the contents and examined the under-voltage causes of the protection potential.

  • PDF

A Study for Development of Durability of the Subway Concrete Structure exposed to Choride Environment (염해 환경에 있는 지하철 콘크리트 구조물의 내구성 향상 대책수립에 관한 연구)

  • Lee Moo-Kwan;Kim Eun Kyum;Kim Dae Ho
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.1184-1189
    • /
    • 2005
  • Durability of concrete has been currently issued in the engineering societies and a large number of studies on the concrete corrosion in salty environment have been performed. The reinforcement corrosion, which is the primary reason of deterioration of the concrete structure exposed to chloride environment. is caused by the chloride ions infiltration owing to underground water seeping into the concrete. In this study. the endurance periods using the diffusion equation of the concrete specification have been evaluated on the concrete structures with different addictives for the brand new R/C subway structure exposed to seashore underground water. Furthermore. the guidance for proper use of the addictives and the reasonable thickness of concrete cover are derived for concrete mixing. From the result of the evaluation corresponding to salt damage for Inchon subway line I, the endurance periods of the ordinary Portlandcement concretes are represented as $42\~75$ years and fail to achieve the objective period of 100 years. However, the lower water-cement ratio expands the endurance periods and the blast furnace slag concrete with small quantity of the silica fume, which shows the best performance of corrosion resistance in this study, represents more than 170 years of the endurance period. Moreover, the case of use of blast furnace slag and fly ash together shows the endurance period of $134\~171$ years and it means that the result very satisfies the objective endurance period.

  • PDF