• 제목/요약/키워드: underground depth

검색결과 648건 처리시간 0.025초

냉방과 난방 부하 감소를 위한 지하피트의 이용 가능성 (The Possibility on Utilization of Underground Pit for Reduction of Cooling and Heating Load)

  • 조성우
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.144-150
    • /
    • 2006
  • The purpose of this study is to predict outlet temperature and humidity through underground pit for the reduction of cooling load and heating load. Commonly, the underground temperature is lower than outdoor in summer but the reverse happens in winter. When the outdoor average air temperature is $25.7^{\circ}C$ during cooling periods, the average outlet air temperature through underground pit is $23.6^{\circ}C$ with 3 m-depth and 60m-length and is $22.2^{\circ}C$ with 3 m-depth and 150 m-length. When the outdoor average air temperature is $4.9^{\circ}C$ during heating periods, the average outlet air temperature through underground pit is $7.7^{\circ}C$ with 3m-depth and 60 m-length and is $10.8^{\circ}C$ with 3 m-depth and 150 m-length. The outlet air temperature is affected by more length than depth of underground pit. The diffusion ratio of outdoor humidity is $-7.7\times10^{-8}kg/s$ in cooling periods and $9.29\times10^{-7}kg/s$ in heating periods.

지하거주공간의 연간 열환경에 관한 연구 (A Study on the Yearly Thermal Environmental Characteristics in Underground Space)

  • 정효민;정한식
    • 동력기계공학회지
    • /
    • 제2권3호
    • /
    • pp.27-33
    • /
    • 1998
  • The room temperature and air conditioning load in the underground space have been investigated numerically by the unsteady heat conduction equation. The model room has 3 m in height and 10 m in width, and it's position in the underground depth are 0.5 m to 5 m. When the room was located around surface, the room temperatures were strongly influenced by the atmosphere. But the underground depth is more than 2 m, the yearly temperature amplitude was small and the temperature phase was delayed. Up to 5 m of the depth, the cooling and heating load was decreased rapidly, but over 10 m of the depth, the air conditioning load was constant.

  • PDF

Safety assessment of an underground tunnel subjected to missile impact using numerical simulations

  • Thai, Duc-Kien;Nguyen, Duy-Liem;Pham, Thanh-Tung;Pham, Thai-Hoan
    • Computers and Concrete
    • /
    • 제27권1호
    • /
    • pp.1-12
    • /
    • 2021
  • This work presents a safety assessment of an underground tunnel subjected to a ballistic missile attack employing the numerical approach. For the impact simulation, a box shaped reinforced concrete (RC) structure with a cross section dimension of 8.0×10.0 m under a soil layer that was attacked by a SCUD missile was modeled using finite element (FE) software LS-DYNA. SCUD missile is one of a series of tactical ballistic missiles developed by Soviet Union during the Cold War, which is adopted for a short-range ballistic missile. The developed FE simulation for the penetration depth of the missile impacting into the soil structure was verified from the well-known formula of the penetration prediction. The soil-structure interaction, the soil type, and the impact missile velocity effects on the penetration depth of the missile into the different soil types were investigated. The safety assessment of the underground tunnel was performed with regard to the different depths of the underground tunnel. For each missile velocity and soil type, a specific depth called the unsafe depth was obtained from the analysis results. The structure beneath the soil beyond this depth remains safe. The unsafe depth was found to be increased with the increasing missile velocity.

The buried arch structural system for underground structures

  • Hernandez-Montes, Enrique;Aschheim, Mark;Gil-Martin, Luisa Maria
    • Structural Engineering and Mechanics
    • /
    • 제20권1호
    • /
    • pp.69-83
    • /
    • 2005
  • In many cases, underground structures are built using conventional above-grade structural systems to carry gravity load. This paper proposes the use of underground arches, termed "buried arches", to support gravity loads, wherein the horizontal thrust of the arch is equilibrated by soil pressure. Because the horizontal soil pressure increases with depth, the depth of the arch may be reduced as the depth below grade increases. Critical to the success of such an approach is a proper accounting of creep and shrinkage for arches made of reinforced concrete. This paper addresses the influence of equilibrium, creep, and shrinkage as they affect the design of the arch from a theoretical perspective. Several examples illustrate the use of buried arches for the design of underground parking structures.

지중 연성관의 거동특성 분석 (Analysis of Behavior for Underground Flexible Pipes)

  • 김경열;상현규;이대수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.315-322
    • /
    • 2001
  • Underground flexible pipes for electric cables are subject to external loads and surrounding soil pressure. Particularly, strain of flexible pipes is of great concern in terms of safety and maintenance for electric cables. In this paper, stress and strain of flexible pipes with various depth are calculated using traditional formula and FEM analysis. The results show that theoretical values are more conservative in strain whereas FEM analysis gives larger stress. Considering the strain criteria - 3.5 %, maximum, flexible pipes can be buried at the range of 50cm to 5m in depth without additional soil improvement.

  • PDF

핵실험과 지각변동 (Underground Nuclear Test and Crustal Deformation)

  • 김익곤
    • 기술사
    • /
    • 제44권1호
    • /
    • pp.44-47
    • /
    • 2011
  • Huge amount of energy produced by an underground nuclear test is released into the surrounding rock. Depending on the properties of the bed rock surrounding the detonation and overlaying it a variety of effects can occur. At some particular depth the increasing amount of material thrown upward is exactly balanced by the decreasing fraction escaping the crater, the crater volume reaches to a maximum. This depth is called the optimum depth of burial and varies somewhat with the geology of the site, being greater for less dense and structurally weaker material.

  • PDF

대심도 복층터널 화재 시 유입풍속 저감방안 연구 (A Study on the Inflow Velocity Reduction Measures in Case of Fire Great Depth Underground Double-Deck Tunnel)

  • 양용원;문정주;신태균
    • 한국화재소방학회논문지
    • /
    • 제30권2호
    • /
    • pp.81-86
    • /
    • 2016
  • 최근 국내 도심지 도로는 빈번한 교통정체가 발생하고 있다. 도심지 교통정체를 해소하기 위한 방안으로 국내에서는 대심도 복층터널에 대한 계획이 이루어지고 있다. 국내에서 계획되는 대심도 복층터널은 소형차 전용으로 계획되며 네트워크형의 구조를 가지고 있어 차량의 출입이 지하공간에서 이루어지고 있다. 이러한 네트워크형 대심도 복층터널은 터널의 단면 및 높이가 일반도로터널 보다 작고 차량의 출입으로 인한 교통풍의 작용으로 화재연기가 터널 승객의 대피보다 빠르게 전파되어 인명피해 발생이 예상된다. 따라서 본 연구에서는 국내 네트워크형 대심도 복층터널에 화재시 화재연기 확산지연을 방지하고자 화재연기 확산지연 장치 작동시 터널 차단면적에 터널 내 작용하는 유입풍의 저감효과를 분석하였으며, 분석결과 터널 차단면적이 50% 이상일 경우 터널 내 작용하는 풍속을 약 21% 저감시키는 효과가 나타났으며, 면적이 50% 이상일 경우 화재 연기의 확산속도를 약 21% 저감시켜 안전한 대피에 도움이 될 것이라 판단된다.

지하공동에 인접한 연속기초의 안정성 (The Stability of Strip Footing above Underground Cavity)

  • 오세욱;이봉직;배우석
    • 한국지반환경공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.69-76
    • /
    • 2006
  • 본 연구는 모래지반에서 공동위에 위치한 연속기초의 지지력거동을 연구하기 위하여 강사법으로 조성된 모래지반에서 모형실험을 수행하였다. 모형실험결과와 이론식을 비교하여 지하공동이 연속기초의 지지력에 영향을 미치는 한계범위를 도출하였다. 한계범위의 크기는 기초의 형상, 지반특성, 공동크기, 공동형상 등 여러 가지 인자에 의존한다. 지하공동의 깊이가 편심거리보다 극한지지력에 더 큰 영향을 주는 것으로 나타났다. 또한 연속기초에 미치는 지하공동의 영향은 편심거리에 따른 지지력 감소현상 뿐만 아니라 연속기초의 부등침하 현상에도 큰 영향을 줄 것으로 판단되었다.

  • PDF

대심도 복층터널에 설치 가능한 화재연기 확산지연장치 성능 평가 연구 (A evaluation study of a fire smoke diffusion delay device installed in a great depth underground double deck tunnel)

  • 신태균;문정주;양용원;이윤택
    • 한국터널지하공간학회 논문집
    • /
    • 제20권1호
    • /
    • pp.225-234
    • /
    • 2018
  • 국내 대도시 도심지역은 지속적인 인구증가와 교통량의 증가로 심각한 교통혼잡 문제가 발생하고 있다. 교통혼잡 등의 문제를 해결하기 위한 방안으로 서울, 부산 등의 도심지에서는 지하공간을 활용한 소형차 전용 대심도 복층터널 연구가 활발히 이루어지고 있다. 이러한 소형차 전용 대심도 복층터널의 특징은 비교적 단면의 높이가 낮아 터널 내 화재 발생시 화재연기의 전파가 전 차종이 통행 가능한 일반적인 도로 터널보다 빠르게 전파되어 인명피해 발생이 우려된다. 따라서, 소형차 전용 대심도 복층터널에 화재 발생시 화재연기의 확산을 지연시켜 인명피해 발생을 최소화시키는 화재연기 확산지연장치가 필요하다. 선행하여 연구된 대심도 복층터널 화재시 연기확산 방지연구에서 3차원 CFD 해석을 통하여 화재연기 확산지연장치 작동 시 차단 면적에 따라 확산 효과를 분석하였고, 대심도 복층터널 화재연기 확산지연장치 연구개발에서는 대심도 복층터널에 적용성이 뛰어나며 경제적으로 상품가치가 높은 스프링 탄성을 이용한 화재연기 확산지연장치에 대하여 연구하였다. 이에, 본 연구에서는 화재연기 확산을 지연시키기 위한 화재연기 확산지연장치 시제품을 제작하여 화재연기 확산지연 효과를 실험하였으며, 분석 결과 화재연기 확산지연장치 작동 시 화재연기 지연효과가 나타났다. 따라서, 화재연기 확산지연 장치를 대심도 복층터널에 적용시 대피자들의 인명피해를 최소화시킬 수 있을 것으로 판단된다.