• 제목/요약/키워드: underground concrete

검색결과 596건 처리시간 0.027초

The buried arch structural system for underground structures

  • Hernandez-Montes, Enrique;Aschheim, Mark;Gil-Martin, Luisa Maria
    • Structural Engineering and Mechanics
    • /
    • 제20권1호
    • /
    • pp.69-83
    • /
    • 2005
  • In many cases, underground structures are built using conventional above-grade structural systems to carry gravity load. This paper proposes the use of underground arches, termed "buried arches", to support gravity loads, wherein the horizontal thrust of the arch is equilibrated by soil pressure. Because the horizontal soil pressure increases with depth, the depth of the arch may be reduced as the depth below grade increases. Critical to the success of such an approach is a proper accounting of creep and shrinkage for arches made of reinforced concrete. This paper addresses the influence of equilibrium, creep, and shrinkage as they affect the design of the arch from a theoretical perspective. Several examples illustrate the use of buried arches for the design of underground parking structures.

지하 구조물 동절기 온도조건에서의 방수공법별 습도 변화량 분석 (Humidity Change Rate Analysis for Various Waterproofing Method in Underground Structures During Winter Season)

  • 안기원;이연실;이정훈;송제영;오상근
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제20권1호
    • /
    • pp.118-125
    • /
    • 2016
  • 현재 대형 빌딩이나 공동주택에 건설되는 지하구조물은 건조수축, 시공이음, 폼타이부 등에서 콘크리트 균열로 인한 누수가 많이 발생되고 있다. 누수가 발생하게 되면 구조물의 지하공간은 결로, 곰팡이 등이 발생되어 지하 환경을 악화시키고 구조물의 콘크리트로 흡수되면 철근의 부식 등을 유발하여 구조물의 안전을 위협한다. 이는 지하구조물의 사용과정에서 장기적인 쾌적성과 구조물에 안전성이 고려되지 않은 설계와 시공의 결과이며 누수 하자에 대하여 유도배수처리로 대응하기 때문에 근본적인 누수보수가 이루어지지 않아 지하구조물은 항시 누수를 허용하고 있는 실정이다. 따라서 본 연구에서는 지하에 적용되는 방수공법을 내방수와 외방수로 분류하고 이를 바탕으로 지하구조물과 유사한 간이시험체를 제작하였으며, 결로가 많이 발생되는 동절기의 온도조건을 기준으로 지하환경의 방수공법별 습도변화량을 분석할 것이다.

Seismic behaviors of ring beams joints of steel tube-reinforced concrete column structure

  • Zhang, Yingying;Pei, Jianing;Huang, Yuan;Lei, Ke;Song, Jie;Zhang, Qilin
    • Steel and Composite Structures
    • /
    • 제27권4호
    • /
    • pp.417-426
    • /
    • 2018
  • This paper presents the seismic behaviors and restoring force model of ring beam joints of steel tube-reinforced concrete column structure under cyclic loading. First, the main failure mode, ultimate bearing capacity, stiffness degradation and energy dissipation capacity are studied. Then, the effects of concrete grade, steel grade, reinforcement ratio and radius-to-width ratios are discussed. Finally, the restoring force model is proposed. Results show that the ring beam joints of steel tube-reinforced concrete column structure performs good seismic performances. With concrete grade increasing, the ultimate bearing capacity and energy dissipation capacity increase, while the stiffness degradation rates increases slightly. When the radius-width ratio is 2, with reinforcement ratio increasing, the ultimate bearing capacity decreases. However, when the radius-to-width ratios are 3, with reinforcement ratio increasing, the ultimate bearing capacity increases. With radius-to-width ratios increasing, the ultimate bearing capacity decreases slightly and the stiffness degradation rate increases, but the energy dissipation capacity increases slightly.

현장재하실험을 통한 PC지하주차장 주조물의 거동분석 (Assessments of Precast Concrete Underground Parking Garage Using Site Instrumentations)

  • 곽효경;윤정방;이형진;이석용
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.248-255
    • /
    • 1997
  • The structural behaviors under wheel loads are much different from those under uniform loads which are generally adopted for the design of parking garage. In such a viewpoint, the structural behavior of a Half-PC concrete underground parking garage under wheel loads was investigated using the site instrumentations. The static wheel loads were applied on the structure to evaluate the actual static resistance, and moving load tests were also performed to evaluate the impact factors of the structure. Besides, the impact tests were also conducted to estimate the modal parameters of the structure. Through the experimental investigations, it was found that the structural performance of the underground parking garage can be improved by use of structural type such as Half-PC concrete structures.

  • PDF

지하 콘크리트 구조물에 적용되는 에폭시 수지계 주입형 누수보수재료의 화학저항성능 평가 (Evaluation of Chemical Resistance of Epoxy Resin Injection Type Leakage Repairing Materials Applied to Underground Concrete Structures)

  • 박소영;김수연;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.41-42
    • /
    • 2017
  • In this study, an investigation was made to study the chemical resistance performance of epoxy resin injection type leakage repair material used in the Korean construction market in accordance to the test method outlined in "ISO TS 16774, Part 2; Test Method for Chemical Resistance." This is a new standard document used for quality control method of injection type repair material used for leakage cracking of underground concrete structures. The results of this study can be expected to be utilized as reference data that can be used for quality improvement of the maintenance methods for future construction.

  • PDF

Reliability of underground concrete barriers against normal missile impact

  • Siddiqui, N.A.;Khan, F.H.;Umar, A.
    • Computers and Concrete
    • /
    • 제6권1호
    • /
    • pp.79-93
    • /
    • 2009
  • In the present paper, a methodology has been presented for the reliability assessment of concrete barriers that lie at a certain depth in the soil, and a missile (a rigid projectile) impacts the top of the soil cover normally, and subsequently after penetrating the soil cover completely it hits the barrier with certain striking velocity. For this purpose, using expressions available in the literature, striking velocity of missile at any depth of soil has been derived and then expressions for the depths of penetration in crater and tunnel region of concrete barrier have been deduced. These depths of penetration have been employed for the derivation of limit state functions. Using the derived limit state functions reliability assessment of underground concrete barrier has then been carried out through First Order Reliability Method (FORM). To study the influence of various random variables on barrier reliability, sensitivity analysis has also been carried out. In addition, a number of parametric studies is conducted to obtain the results of practical interest.

복공식 지하 압축공기에너지 저장공동 기밀시스템 설계변수의 민감도 해석 (Sensitivity Analysis of Design Parameters of Air Tightness in Underground Lined Rock Cavern (LRC) for Compressed Air Energy Storage (CAES))

  • 김형목;;류동우;선우춘;송원경
    • 터널과지하공간
    • /
    • 제21권4호
    • /
    • pp.287-296
    • /
    • 2011
  • 본 연구에서는 압축공기에너지 지하저장을 위한 복공식 암반공동의 기밀성능을 평가할 목적으로 다상유체 열유동 해석을 수행하였다. 기밀성능은 저장공동으로부터 누출되는 공기질량으로 평가하였으며, 저장공동 내부에 콘크리트 라이닝 기밀시스템을 설치하고 저장공동은 비교적 천심도인 지하 100m 심도에 위치하는 것으로 가정하였다. 저장공동 내 질량수지분석 결과, 콘크리트 라이닝 및 주변 암반의 투과계수가 누기량 및 저장공동의 장기적 기밀성능에 미치는 영향이 큰 것으로 파악되었으며 콘크리트 라이닝의 투과계수가 $1.0{\times}10^{-18}\;m^2$이하 일 경우, 저장공동 운영압력이 5 MPa에서 8 MPa 사이일 때 누기량은 1%이하 인 것으로 계산되었다. 또한, 콘크리트 라이닝의 초기포화도에 따른 공기누출량 계산결과, 라이닝 수분포화도를 증가시킬수록 누기량은 감소하고 저장공동 기밀성능이 향상됨을 확인하였다.

강섬유 보강 콘크리트의 전자파 차폐효과 (Electromagnetic wave shielding effectiveness of steel fiber reinforced concrete)

  • 이규필;장수호;최순욱;배규진;박영택
    • 한국터널지하공간학회 논문집
    • /
    • 제17권2호
    • /
    • pp.107-115
    • /
    • 2015
  • 전력구 방식의 지중 송전선로 시공시 TBM 공법이 널리 적용되고 있으며, 세그먼트의 구조적 특징에 따라 강섬유 보강 콘크리트를 이용한 세그먼트의 개발과 사용이 크게 증가하는 추세이다. 그러나 최근 지중 송전선로 구간에서의 전자파 유해성에 대한 문제가 대두되고 있으며, 세그먼트 제작시 투입되는 강섬유의 영향으로 콘크리트의 전기전도성 등이 변화되고, 이로 인하여 더 많은 전자파가 지상에서 계측될 수 있다는 우려가 야기되고 있다. 따라서 본 연구에서는 강섬유 보강 유무 및 사용량 변화조건에 따른 전자파의 차폐효과를 분석하기 위하여, 3가지 조건에 대한 실험체를 제작하여 관련 실험을 수행하였으며, 실험결과 강섬유 보강콘크리트와 전자파 발생 상관관계는 없는 것으로 나타났다.

터널 화재로 인한 콘크리트 세그먼트의 손상특성 규명 (Eire-induced Damage to Shield TBM Concrete Segment)

  • 최순욱;장수호;이규필;배규진
    • 한국지반공학회논문집
    • /
    • 제21권5호
    • /
    • pp.171-177
    • /
    • 2005
  • 지하공간에서의 화재는 인명 및 재산피해 뿐만 아니라 지하구조물에 심각한 손상을 발생시킨다. 이러한 화재로부터 구조물을 보호하기 위해서 화재에 의한 지하구조물 시공재료의 손상을 파악하는 것은 매우 중요한 사항이다. 본 연구에서는 화재에 의한 지하구조물의 손상을 파악하기 위하여 지하공간 화재모의시험 가열로를 제작하였고, 쉴드 TBM 콘크리트 세그먼트시편에 대하여 모의 화재실험을 수행하였다. 수행된 실험은 5분에 $1,200^{circ}C$에 도달하여 1시간동안 유지한 후 2시간에 걸쳐 소화되는 RABT곡선을 모사하였다. 시험체내에 설치된 온도센서로 확인한 결과, 화재면으로부터 약 20cm까지 폭렬이 발생하였다. 또한 시험이 완료된 블럭시편으로부터 채취된 코어시편에 수행된 물리$\cdot$화학적 실험을 통하여 폭렬면으로부터 약 l0cm까지 시공재료의 특성이 저하되었음을 확인하였다.