• Title/Summary/Keyword: underground air

Search Result 551, Processing Time 0.022 seconds

The Analysis of heating performance of heat pump system for agricultural facility using underground air in Jeju area - Focused on the Jeju Area - (제주지역 지하공기를 이용한 농업시설용 히트펌프시스템의 난방 성능 분석 - 제주지역을 중심으로 -)

  • Kang, Youn-Ku;Lim, Tae-Sub
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.109-114
    • /
    • 2016
  • Purpose: The underground air is the warm air discharged from the porous volcano bedrock 30-50m underground in Jeju, including excessive humidity. The temperature of the underground air is $15-20^{\circ}C$ throughout the year. In Jeju, the underground air was used for heating greenhouses by supplying into greenhouses directly. This heating method by supplying the underground air into greenhouses directly had several problems. The study was conducted to develop the heat pump system using underground air as heat source for resolving excessive humidity problem of the underground air, adopting the underground air as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) and saving heating cost for agricultural facilities. Method: 35kW scale(10 RT) heat pump system using underground air installed in a greenhouse of area $330m^2$ in Jeju-Special Self-Governing Province Agricultural Research & Extension Services, Seogwipo-si, Jeju. The inlet and outlet water temperature of the condenser, the evaporator and the thermal storage tank and the underground air temperature and the air temperature in the greenhouse were measured by T type thermocouples. The data were collected and saved in a data logger(MV200, Yokogawa, Japan). Flow rates of water flowing in the condenser, the evaporator and the thermal storage tank were measured by an ultrasonic flow meter(PT868, Panametrics, Norway). The total electric power that consumed by the system was measured by a wattmeter(CW240, Yokogawa, Japan). Heating COP, rejection heat of condenser, extraction heat of evaporator and heating cost were analyzed. Result: The underground air in Jeju was adopted as a farm supporting project by Ministry of Agriculture, Food and Rural Affairs(MAFRA) in 2010. From 2011, the heat pump systems using underground air as a heat source were installed in 12 farms(16.3ha) in Jeju.

Performance of Heat Pump System Using Underground Air as Heat Source (지하공기를 이용하는 농업시설용 난방시스템)

  • Kang, Youn-Ku;Ryou, Young-Sun;Kim, Young-Hwa;Sung, Moon-Seok;Kim, Jong-Koo;Jang, Jae-Kyoung;Lee, Hyoung-Mo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.587-589
    • /
    • 2009
  • The districts of underground geologic structure in Jeju island where underground air is distributed are lava cave, pyroclastic, open joint, and crushing zone. Such districts are identified to secure an enough airflow when air ventilation layer is to secure 25-35m in depth. In Jeju, Ground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But the heating method by suppling ground air into greenhouse directly bring about several problem. The occurrence of disease of the crops by high humidity is worried because the underground air which becomes discharge from underground air layer has over 90% relative humidity. The underground air is inadequate in heating for crops which need high temperature heating such as mangos, Hallbong and mandarin orange because the temperature of it is $15{\sim}18^{\circ}C$. Also There is worry where the ventilation loss becomes larger because the air pressure inside greenhouse is high by supplying underground air directly. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analysed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air were 40,000~27,000 kcal/h, 30,000~18,000 kcal/h respectively.

  • PDF

Performance of Underground Air-to-Water Heat Pump with Direct Contact Heat Exchanger (지하공기-물 직접접촉식 열교환기를 구비한 히트펌프의 성능)

  • Kim, Y.H.;Kang, Y.K.;Sung, M.S.;Ryou, Y.S.;Kim, J.G.;Jang, J.K.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.172.1-172.1
    • /
    • 2010
  • In Jeju, underground air is used for heating greenhouse and fertilizing natural $CO_2$ gas by suppling directly into greenhouse. But greenhouse heating method by direct supply of underground air has several problems as like low temperature below $20^{\circ}C$ or high relative humidity over 90%. The underground air is inadequate in heating of crops such as mangos, oranges with the growing temperature over $20^{\circ}C$. Also if the relative humidity of greenhouse is kept with over 90%, diseases can strike almost of the crops. And also the ventilation loss becomes larger because the air pressure of inside greenhouse by direct supply of underground air is higher. In this study the heat pump system using underground air as heat source was developed and heating performance of the system was analyzed. Heating COP of the system was 2.5~5.0 and rejecting heat into greenhouse and extracting heat from underground air in this heat pump system were 46.5~31.4 kW, 34.9~20.9 kW respectively.

  • PDF

Estimation of Risk from Air Pollution in the Underground Highway Proposed to Construct in Seoul, Korea

  • Lee, Ki-Young;Yukio-Yanagisawa
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.9 no.E
    • /
    • pp.397-400
    • /
    • 1993
  • The possible air pollution problems in a proposed underground highway are discussed using carbon monoxide (CO) as an indicator. Carbon monoxide concentrations in the underground highway depend on several factors, including the size of tunnel, the number of automobiles, the CO emission rate, and the tunnel ventilation rate. Using the estimated values, CO concentrations in the underground highway can be predicted. Without proper ventilation system, CO concentration in the underground highway can be dangerous level. However, the cost of operating the mandatory mechanical ventilation system may be tremendouslyy high and may be technically unrealistic to implement. If the underground highway is constructed with proper ventilation system, a continuous air pollution monitoring system with alarming function must be installed to alert personnel of serious air pollution built up in the underground highway. Traffic must be restricted, whenever the inside air pollution levels exceed agreed values. Short distances between evacuation exits are necessary for emergency situations or malfunction of ventilation system.

Heating Effect of Greenhouse Cultivated Mangos by Heat Pump System using Underground Air as Heat Source (지하공기 이용 히트펌프시스템의 망고온실 난방효과)

  • Kang, Younkoo;Kim, Younghwa;Ryou, Youngsun;Kim, Jongkoo;Jang, Jaekyoung;Lee, Hyoungmo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.200.1-200.1
    • /
    • 2011
  • Underground air is a special energy source in Jeju and distributes lava cave, pyroclastic, open joint, and crushing zone. A possible area to utilize underground air is 85% of Jeju except to the nearby area of Sambang Mt. and 25m high coastal area from sea level. In Jeju, underground air is used for heating agricultural facilities such as greenhouse cultivated mangos, Hallbong and mandarin orange, pigsty, mushroom cultivation house, etc. and fertilizing natural $CO_2$ gas by suppling directly into agricultural facilities. But this heating method causes several problem because the underground air has over 90% relative humidity and is inadequate in heating for crops. Mangos are the most widely grown tropical fruit trees and have been cultivated since 1993 in Jeju. In Jeju, the cultivating area is about 20ha and amount of harvest is 275ton/year in 2010. In this study, the heat pump system using underground air as heat source was installed in mangos greenhouse which area is $495m^2$. The capacity of heat pump system and heat storage tank was 10RT, 5ton respectively and heating effect and heating performance of the system were analysed.

  • PDF

The Possibility on Utilization of Underground Pit for Reduction of Cooling and Heating Load (냉방과 난방 부하 감소를 위한 지하피트의 이용 가능성)

  • Cho Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.144-150
    • /
    • 2006
  • The purpose of this study is to predict outlet temperature and humidity through underground pit for the reduction of cooling load and heating load. Commonly, the underground temperature is lower than outdoor in summer but the reverse happens in winter. When the outdoor average air temperature is $25.7^{\circ}C$ during cooling periods, the average outlet air temperature through underground pit is $23.6^{\circ}C$ with 3 m-depth and 60m-length and is $22.2^{\circ}C$ with 3 m-depth and 150 m-length. When the outdoor average air temperature is $4.9^{\circ}C$ during heating periods, the average outlet air temperature through underground pit is $7.7^{\circ}C$ with 3m-depth and 60 m-length and is $10.8^{\circ}C$ with 3 m-depth and 150 m-length. The outlet air temperature is affected by more length than depth of underground pit. The diffusion ratio of outdoor humidity is $-7.7\times10^{-8}kg/s$ in cooling periods and $9.29\times10^{-7}kg/s$ in heating periods.

A study on the availability of underground air for heating/cooling energy in volcano-stratigraphic (화산지질층 지하공기 열원 이용 가능성에 관한 연구)

  • Kim, Yong-Hwan;Kim, Sung-Man;Lee, Dong-Won;Hyun, Myun-Taek
    • Journal of Power System Engineering
    • /
    • v.17 no.6
    • /
    • pp.136-141
    • /
    • 2013
  • This study introduces and analyzes the energy for heating and cooling system in region with volcano-stratigraphic. The thermodynamic properties of air through the air blower installed at the entrance of borehole are measured. It estimates the availability of underground air for heating and cooling system through experimental data and theoretical analysis. Based on our conclusion from these calculations we predict possibility of over 40kW steady and stable energy source from underground. Therefore this underground air can be utilized in region with volcano-stratigraphic.

An Experimental Study on the Characteristics of Train-Wind in Underground Shopping Center Connected to Subway Station (지하도 상가와 지하 역사 연계구에서 열차풍 발생 특성에 관한 실험적 연구)

  • Hwang, In-Ju;Lee, Hong-Cheol
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.82-87
    • /
    • 2005
  • The characteristics of train-wind in the underground shopping center(UGSC) connected to subway station is investigated by field measurement for the case of train movement such as arrival and departure, etc. Also air curtain installed at the pass way between underground shopping center and subway station were considered as the parameter in order to analysis the effect on indoor air quality and thermal condition. The measurement data such as velocity, relative humidity, wind-pressure were plotted as quantity variation with time scale. The train-wind affected wind velocity, air pressure and relative humidity at the connecting area of underground shopping center and subway station, and the variation was about 4.5 m/s, 8%, 40 Pa. Also the result showed that the air curtain is not proper to reduce influence of train-wind

  • PDF

A Study on the Actual Conditions of Indoor Air Quality of Underground Dwellings and the Automatic Ventilating Fan Operated by CO2 Controller and Timer (지하주거의 실내공기환경 실태조사와 CO2 조절기 및 타이머에 의한 환기팬 자동운전에 관한 연구)

  • Kwon, Young Cheol;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.8 no.4
    • /
    • pp.3-9
    • /
    • 2008
  • The rapid urbanization after 1970s caused the shortage of dwellings in urban areas. As the result, the underground dwellings were developed to compensate for the insufficient dwelling spaces. While the underground dwellings have some advantage in the respect of thermal and acoustic environment, they usually have the basic problems in the indoor air quality because of the lack of natural ventilation through small window areas. The purpose of this study is to investigate and to improve the indoor air quality of underground dwellings. Thirty Units in Seoul and Gyung-Gi Province were investigated into the indoor environmental conditions. For the purpose of the improvement of their indoor air quality, Automatically-operated ventilating fan was installed in a sample unit which has worst indoor environmental condition. Then the indoor air quality was monitored when it was operated by $CO_2$ control system and timer. Finally economic feasibility study was made considering the effect of the improvement of indoor air quality. The extra cost for installing timer could be paid back only in 10 months, so timer-installed automatic fan is recommended to improve the indoor air quality of underground dwellings.

A Survey of the Air Quality in Underground Environment (지하환경의 대기오염물질 규제에 관한 조사연구)

  • Lee M. H.;Han E. J.;Shin C. K.;Chung H. D.;Han J. K.
    • Journal of environmental and Sanitary engineering
    • /
    • v.1 no.1 s.1
    • /
    • pp.47-58
    • /
    • 1986
  • The underground living spaces have become one of the major environment of this decade in urban area. This study was carried out to examine contamination level for purpose of preservation of the pleasant underground environment. Three subway stations and three underground shopping centers in Seoul and two underground shopping centers in Busan were selected and surveyed by measuring gaseous pollutants $(SO_2,\; NO_2,\;CO,\;HC,\; HCHO,\;CO_2)$, dust, airborne microbes, and the other air condtions (temperature, humidity, air pressure, air flow, kata cooling power). These examined data were compared with four kinds of standard (building sanitation management, room air quality standards, occupational safety and health standards, ventilation equipment) as environmental hygiene.

  • PDF