• 제목/요약/키워드: unbalance supply voltage

검색결과 39건 처리시간 0.026초

A Simplified Control Algorithm for Three-Phase, Four-Wire Unified Power Quality Conditioner

  • Singh, Bhim;Venkateswarlu, P.
    • Journal of Power Electronics
    • /
    • 제10권1호
    • /
    • pp.91-96
    • /
    • 2010
  • In this paper, a simplified control algorithm for a three-phase, four-wire unified power quality conditioner (UPQC) is presented to compensate for supply voltage distortions/unbalance, supply current harmonics, the supply neutral current, the reactive power and the load unbalance as well as to maintain zero voltage regulation (ZVR) at the point of common coupling (PCC). The UPQC is realized by the integration of series and shunt active filters (AFs) sharing a common dc bus capacitor. The shunt AF is realized using a three-phase, four leg voltage source inverter (VSI) and the series AF is realized using a three-phase, three leg VSI. A dynamic model of the UPQC is developed in the MATLAB/SIMULINK environment and the simulation results demonstrating the power quality improvement in the system are presented for different supply and load conditions.

전압불평형율의 현장측정 및 분석 (Field Measurement and Analysis of Voltage Unbalance Factor)

  • 정종호;박영진;이은웅;김종겸
    • 전기학회논문지P
    • /
    • 제54권1호
    • /
    • pp.41-46
    • /
    • 2005
  • Most of LV customer have applied the 3-phase four wire system distribution system because it has advantage of supplying both of 1-phase & 3-phase loads simultaneously. Due to its structural simplicity, it is more convenient for use rather than the conventional separated scheme. But voltage unbalance more commonly emerges in individual customer loads due to phase load unbalance, especially where, single-phase power loads are used. Voltage unbalance factor(VUF) represents the loss of symmetry in the supply(magnitude and angle). It leads some problems such as de-rating or power losses. In this paper, voltage and current waveform in the actual fields have been measured and analyzed in relation with internationally allowable voltage unbalance limits.

불평형 전압으로 운전시 비선형 부하에 나타나는 현상 (The Phenomena Giving Rise of Nonlinear Load Operated by Unbalance Voltage)

  • 김종겸;이은웅
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제51권6호
    • /
    • pp.285-291
    • /
    • 2002
  • In general, utility voltage is maintained at a relatively low level of Phase unbalance since a low level of unbalance can cause a significant power supply ripple and heating effects on the power system equipment. Voltage unbalance more commonly emerges in individual customer loads due to phase load unbalanced, especially where single phase power loads are used. Under unbalanced input voltages large lower order harmonics appears at the input and output ports of Power conversion devices. As the application of adjustable -speed drives (ASDs) and their integration with complex industrial processes increase, so does the need to understand how ASDs perform during voltage This paper describes a real load test to investigate the performance of 3-HP adjustable speed drives by an unbalanced voltage at the low-voltage system.

회로해석을 이용한 전기철도 급전시스템의 전압불평형 평가 (Voltage Unbalance Evaluation in Autotransformer-Fed Electric Railway Systems using Circuit Analysis)

  • 오광해;차준민
    • 조명전기설비학회논문지
    • /
    • 제12권4호
    • /
    • pp.20-28
    • /
    • 1998
  • This study proposes a new method to estimate voltage unbalance more exactly using Thevenin's equivalent circuit. The conventional simple formula were easily applied to evaluate voltage unbalance. Because the formula was derived on the assumption that traction load would be directly connected to the secondary windings of the main transformer, they could not consider the detailed characteristics of traction power supply system, for example, self and mutual impedances of rail, catenary and return feeder. So, the ac쳐racy of the results could not be guaranteed. The proposed algorithm is applied to a standard autotransformer-fed test system to analyze unbalance phenomena. Through simulations, we could evaluate voltage and current unbalance factors and compare the voltage unbalance of the three transformer connection schemes : single phase, V- and Scott-connections which are required for suitable train operation schedules. Additionally, we could determine the combinations of trains which can be operated under the unbalance factor limits.

  • PDF

불평형 전압 인가시 유도전동기 전류 불평형율 계산 (Calculation of Current Unbalance Factor for Induction Motor under the Unbalanced Voltages)

  • 김종겸;박영진;이은웅;정종호;조현길;이종한;이동주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.633-634
    • /
    • 2006
  • The current unbalance occurs in an induction motor with the supply of unbalanced voltage. Existence of an current unbalance occurs by various problems at the time of driving by in crease of the noise not to mention output decrease of a motor by increase of a loss. We confirmed how current unbalance occurred by a voltage unbalance because a slip came to change by the driving situation of a subordinate as for the induction motor. We confirmed that case to run to a low slip in a ratio of the same voltage unbalance rate brought a high current unbalance rate.

  • PDF

4단자 회로망 모델을 이용한 전기철도 차량기지의 전압불평형 해석 (Analysis of Voltage Unbalance in the Electric Railway Depot Using Two-port Network Model)

  • 창상훈;오광해;김정훈
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권5호
    • /
    • pp.248-254
    • /
    • 2001
  • The traction power demand highly varies with time and train positions and the traction load is a large-capacity current at single phase converted from 3-phase power system. Subsequently, each phase current converted from 3-phase power system cannot be maintained in balance any longer and thus the traction load can bring about imbalance in three-phase voltage. Therefore, the exact assessment of voltage unbalance must be carried out preferentially as well as load forecast at stages of designing and planning for electric railway system. The evaluation of unbalance voltage in areas, such as electric railway depots should be a prerequisite with more accuracy. The conventional researches on voltage unbalance have dealt with connection schemes of the transformers used in ac AT-fed electric railroads system and induced formulas to briefly evaluate voltage unbalance in the system(3). These formulas are still being used widely due to their easy applicabilities on voltage unbalance evaluation. Meanwhile, they don't take into account detailed characteristics of ac AT-fed electric railroads system, being founded on some assumptions. Accordingly. accuracy still remains in question. This paper proposes a new method to more effectively estimate voltage unbalance index. In this method, numerous diverted circuits in electric railway depots are categorized in three components and each component is defined as a two-port network model. The equivalent circuit for the entire power supply system is also described into a two-port network model by making parallel and/or series connections of these components. Efficiency and accuracy in voltage unbalance calculation as well can be promoted by simplifying the circuits into two-port network models.

  • PDF

불평형 전원 전압을 갖는 PWM 컨버터의 입·출력 특성 분석 (Analysis of Input·Output Characteristics in the PWM Converter with Unbalance Supply Voltage)

  • 구자경;김상훈
    • 산업기술연구
    • /
    • 제25권B호
    • /
    • pp.203-210
    • /
    • 2005
  • The PWM(Pulse Width Modulated) converter for the AC to DC rectification has become attractive in the industrial variable-speed drive application and the electric utilities due to the following benefits: Nearly the sinusoidal input current with unity power factor; Controllable DC link voltage; Bidirectional power flow. This paper presents a quantitative analysis of single and three phase PWM converter's input and output characteristics as a function of the input filter inductance under balanced and unbalanced conditions. Also, its performance under the supply voltage including harmonics is investigated by simulation with Matlab Simlulink and experiments. These results provide a reference for selecting the reasonable converter's input filter inductance for given harmonics or power factor criterion.

  • PDF

Unbalanced Power Sharing for Islanded Droop-Controlled Microgrids

  • Jia, Yaoqin;Li, Daoyang;Chen, Zhen
    • Journal of Power Electronics
    • /
    • 제19권1호
    • /
    • pp.234-243
    • /
    • 2019
  • Studying the control strategy of a microgrid under the load unbalanced state helps to improve the stability of the system. The magnitude of the power fluctuation, which occurs between the power supply and the load, is generated in a microgrid under the load unbalanced state is called negative sequence reactive power $Q^-$. Traditional power distribution methods such as P-f, Q-E droop control can only distribute power with positive sequence current information. However, they have no effect on $Q^-$ with negative sequence current information. In this paper, a stationary-frame control method for power sharing and voltage unbalance compensation in islanded microgrids is proposed. This method is based on the proper output impedance control of distributed generation unit (DG unit) interface converters. The control system of a DG unit mainly consists of an active-power-frequency and reactive-power-voltage droop controller, an output impedance controller, and voltage and current controllers. The proposed method allows for the sharing of imbalance current among the DG unit and it can compensate voltage unbalance at the same time. The design approach of the control system is discussed in detail. Simulation and experimental results are presented. These results demonstrate that the proposed method is effective in the compensation of voltage unbalance and the power distribution.

불평형 부하 운전시 3상 유도발전기 특성 해석 (Characteristics Analysis of 3-phase Induction Generator at the Unbalanced Load Operation)

  • 김종겸
    • 전기학회논문지P
    • /
    • 제56권3호
    • /
    • pp.123-128
    • /
    • 2007
  • Hydro power supplies no pollution energy, mainly induction generator has been applied at the small capacity power station. The generating power of small hydro-electric power station connects on the 22.9kV distribution system or low voltage system in the case of three-phase four-wire supply system. There are side effects of various kinds in the 3-three phase 4-wire distribution system mixing 1-phase load and 3-phase load. This system generates the voltage unbalance by unbalanced load operating condition. They have various serious effects on generator and connection system. In this paper, we analyzed what kind of operation characteristic are happened in the induction generator by customer load variation at the 3-three phase 4-wire distribution system.

급전회로망 해석기법을 활용한 전철계통 해석 (Train voltage analysis of railroad system using supply network method)

  • 윤재영;최흥관
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.108-115
    • /
    • 2000
  • This paper presents the new simulation algorithms using network methods to analysis the steady-state train voltage distribution characteristics in ac auto-transformer fed railroads. In general, the supply system of railroads is composed of non-symmetrical and unbalance transmission line. Therefore, the general method using simplified old algorithms have the self-contradictory errors because the supply line of train railroads is completely unbalanced. In this paper, the simulation results of new developed algorithms is compared with those of EMTP to confirm the effectiveness.

  • PDF