• Title/Summary/Keyword: ultrasound pretreatment

Search Result 25, Processing Time 0.025 seconds

Extraction of Genistein and Formononetin from Sophoraflavescens Aiton using Ultrasonic wave (초음파를 이용한 고삼에 포함된 Genistein 및 Formononetin의 추출)

  • Kim, Young Sik;Lee, Kwang Jin
    • Korean Chemical Engineering Research
    • /
    • v.47 no.2
    • /
    • pp.258-261
    • /
    • 2009
  • In this work, we the ettect on extraction amounts and general composition content of phytoestrogen genistein and formononetin extracted from Sophoraflavescens Aiton by various ultrasonic waves(35, 72, and 170 KHz) and extraction time(30, and 60 min) were compared using extraction solvent water 100%. The pretreatment step was composed of ultrasonic waves extraction, filtration, concentration, and membrane filtration. The extracted sample was analyzed by reversed-phase high performance liquid chromatography(RP-HPLC). And the mobile phase applied was linearly changed with A/B of 80/20~65/35 vol% for 60 min(A water/acetic acid, 99.9/0.1 vol%, B acetonitrile/acetic acid, 99.9/0.1 vol%). The experimental results, general composition carbohydrate(0.255 to 0.413%) excepts, other ingredients was confirmed almost similarly. Also, The highest yield of extraction amount 3.17g was obtained by ultrasonic waves with a frequency of 170 KHz and an extraction time of 60 min. This work offers would be useful for chemical and biological studies of natural plants and its products.

Fertility-Preserving Treatments in Patients with Gynecological Cancers: Chinese Experience and Literature Review

  • Liu, Chun-Yan;Li, Hua-Jun;Lin, Hua;Ling, Bin
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4839-4841
    • /
    • 2015
  • We conducted a retrospectively reviewed of the literature published of patients underwent fertility-preserving treatments for cervical, endometrial and ovarian cancers using the WANFANG database in Chinese. A majority were retrospective studies and case reports. With cervical cancer, radical trachelectomy(RT) in combination with pelvic lymphadenectomy could preserve the fertility of patients with early stage IA1-IB1 cancers, Tumor size ${\leq}2cm$ should be emphasized as the indication of RT in considering of the higher recurrent rate in patients with tumor size >2cm. For endometrial cancers, there is much experience on it. Given accurate pretreatment assessment, hormonal therapy is feasible management option to preserve fertility in young patients with early stage lesions that limited to the endometrium and well differentiated. High dose progestin have been applied, oral medroxyprogesterone acetate (MPA), 250-500mg/day, megestrol acetate 160-480mg/day. Other therapies that have been used in a limited number of cases include GnRH analog, intrauterine devices (IUDS) containing progestogen, usually combination of these therapies. All patients should be followed up by ultrasound and/or MRI evaluation, and endometrial curettage at intervals of 3 months. With ovarian cancer, in China, fertilitypreserving surgery in patients with stage IA (grade G1) of epithelial ovarian tumor and patients with germ cell tumor and borderline ovarian tumor have been successfully performed.

A Study on Rapid Residual Analysis of Benzo(a)pyrene in Agricultural Products and Soils (농산물 및 경작지 토양 시료 중 Benzo(a)pyrene 신속잔류분석법 개선 연구)

  • Kim, Hee-Gon;Ham, Hun-Ju;Hong, Kyong-Suk;Shin, Hee-Chang;Hur, Jang Hyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.39 no.1
    • /
    • pp.44-49
    • /
    • 2020
  • BACKGROUND: Benzo(a)pyrene is a highly toxic substance which has been listed as a Group I carcinogen by the International Agency for Research on Cancer. There have been numerous studies by researchers worldwide on benzo(a)pyrene. Soxhlet, ultrasound-assisted, and liquid-liquid extractions have been widely used for the analysis of benzo(a)pyrene. However these extraction methods have significant drawbacks, such as long extraction time and large amount of solvent usage. To overcome these disadvantages, we aimed to establish a rapid residual analysis of benzo(a)pyrene content in agricultural products and soil samples. METHODS AND RESULTS: A Quick, Easy, Cheap, Effective, Rugged, and Safe (QuEChERS) method was used as the pretreatment procedure. For rapid residual analysis of benzo(a)pyrene, a modified QuEChERS method were used, and the best codition was demonstrated after various performing instrument analysis. The extraction efficiency of this method was also compared with Soxhlet extraction, the current benzo(a)pyrene extracting method. Although both methods showed high recovery rates, the rapid residual analysis method markedly reduced both the measurement time and solvent usage by approximately 97% and 96%, respectively. CONCLUSION: Based on these results, we suggest the rapid residual analysis method established through this study, faster and more efficient analysis of residual benzo(a)pyrene in major agricultural products such as rice, green and red chili peppers and also soil samples.

Pre-radiotherapy and Post-radiotherapy Serial Serum Squamous Cell Carcinoma Antigen (SCC) and Carcinoembryonic Antigen (CEA) in the Monitoring of Squamous Cell Carcinoma of Uterine Cervix (자궁경부암 방사선치료시 Squamous Cell Carcinoma Antigen(SCC) 고k Carcinoembryonic Antigen(CEA) 의 종양표지자로서의 의의)

  • Yun, Hyong-Geun;Park, Choong-Hak
    • Radiation Oncology Journal
    • /
    • v.17 no.1
    • /
    • pp.30-35
    • /
    • 1999
  • Purpose : To evaluate the significance of squamous cell carcinoma antigen (SCC) and carcinoembryonic antigen (CEA) as tumor markers in uterine cervix carcinoma. Materials and Methods : In 22 patients with histologically proven primary squamous cell carcinoma of uterine cervix, tumor volume was checked either by using MRI (in 20 patients) or ultrasound (in 2 patients). Pre-treatment serum SCC levels were checked in 22 patients and CEA levels in 21 patients. After curative radiotherapy, post-treatment SCC and CEA were checked regularly. Results : SCC was raised In 68.2$\%$ and CEA was raised in 19.0$\%$ before treatment. The coefficient of correlation between tumor volume and pre-reatment SCC was 0.59382 when one extremely deviated case was excluded. And there was no correlation between tumor volume and CEA. After the treatment, SCC was raised En 9.1$\%$ and CEA was raised in 4.8$\%$. In further follow up measurement, raise of SCC was associated with clinical relapse or persistence of disease. The specificity of raised SCC level in association with recurrent or persistent disease was 93.8$\%$ . The sensitivity in association with recurrent or persistent disease was 100$\%$. The positive predictive values was 85.7$\%$. The median lead time for recurrence was 1.2 months. Conclusions: Both SCC and CEA were good tumor markers for monitoring treatment effect in patients with raised pre-treatment levels. But the sensitivity of pretreatment CEA was low, while that of pretreatment SCC was high. And there was no additional gain by adding CEA measurements to SCC measurements.

  • PDF

A study of analytical method for Benzo[a]pyrene in edible oils (식용유지 중 벤조피렌 분석법 비교 연구)

  • Min-Jeong Kim;jun-Young Park;Min-Ju Kim;Eun-Young Jo;Mi-Young Park;Nan-Sook Han;Sook-Nam Hwang
    • Analytical Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.291-299
    • /
    • 2023
  • The benzo[a]pyrene in edible oils is extracted using methods such as Liquid-liquid, soxhlet and ultrasound-assisted extraction. However these extraction methods have significant drawbacks, such as long extraction time and large amount of solvent usage. To overcome these drawbacks, this study attempted to improve the current complex benzo[a]pyrene analysis method by applying the QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe) method that can be analyzed in a simple and short time. The QuEChERS method applied in this study includes extraction of benzo[a]pyrene into n-hexane saturated acetonitrile and n-hexane. After extraction and distribution using magnesium sulfate and sodium chloride, benzo[a]pyrene is analyzed by liquid chromatography with fluorescence detector (LC/FLR). As a result of method validation of the new method, the limit of detection (LOD) and quantification (LOQ) were 0.02 ㎍/kg and 0.05 ㎍/kg, respectively. The calibration curves were constructed using five levels (0.1~10 ㎍/kg) and coefficient (R2) was above 0.99. Mean recovery ratio was ranged from 74.5 to 79.3 % with a relative standard deviation (RSD) between 0.52 to 1.58 %. The accuracy and precision were 72.6~79.4 % and 0.14~7.20 %, respectively. All results satisfied the criteria ranges requested in the Food Safety Evaluation Department guidelines (2016) and AOAC official method of analysis (2023). Therefore, the analysis method presented in this study was a relatively simple pretreatment method compared to the existing analysis method, which reduced the analysis time and solvent use to 92 % and 96 %, respectively.