• Title/Summary/Keyword: ultrasound imaging

Search Result 657, Processing Time 0.023 seconds

The Reliability of Thickness Measurement of the Deep Fiber of the Lumbar Multifidus Using Ultrasonography

  • Jung, Doh-Heon;Kim, Su-Jung;Yi, Chung-Hwi;Cynn, Heon-Seock;Choi, Houng-Sik
    • Physical Therapy Korea
    • /
    • v.17 no.4
    • /
    • pp.49-54
    • /
    • 2010
  • The reliability of the thickness measurement of the lumbar multifidus (LMD using real-time ultrasonography (US) was determined in only the superficial fiber of the lumbar multifidus (SM). However, previous studies have not examined the reliability of the deep fiber of the LM (DM). The purpose of this study was to determine the intrarater and the interrater reliability of the thickness measurements of DM using US. Eleven heathy males participated in the study. The thickness of the DM was measured with an US in the prone position. Reliability was examined using intraclass correlation coefficients (ICC), standard error of the measurement (SEM), and the Bland and Altman plot. ICC(3,1) was used to calculate the interrater reliability of the thickness measurement of DM using the values from both the first and second test sessions. Additionally, ICC(3,1) was used to calculate the intrarater reliability of the measurements over two days using the measurements obtained in test session 1 and lest session 2. The results of this study were as follows: 1) the ICC(3,1) value for interrater reliability was .94 in the first test session, and .93 in the second test session. 2) the ICC(3,1) values for intrarater reliability of the measurements over two days was .90 in both the first examiner and the second examiner. The interrater reliability and interrater reliability of the DM measurements, obtained via the US protocol used in this research was excellent. Therefore, we conclude that the thickness measurement of the DM obtaioned from the US protocol used in this research would be useful for clinician assessment of the thickness of the DM.

A case of McKusick-Kaufman syndrome

  • Son, Se-Hyung;Kim, Yoon-Joo;Kim, Eun-Sun;Kim, Ee-Kyung;Kim, Han-Suk;Kim, Beyong-Il;Choi, Jung-Hwan
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.5
    • /
    • pp.219-223
    • /
    • 2011
  • McKusick-Kaufman syndrome (MKS) is an autosomal recessive multiple malformation syndrome characterized by hydrometrocolpos (HMC) and postaxial polydactyly (PAP). We report a case of a female child with MKS who was transferred to the neonatal intensive care unit of Seoul National University Children's Hospital on her 15th day of life for further evaluation and management of an abdominal cystic mass. She underwent abdominal sonography, magnetic resonance imaging, genitography and cystoscopy which confirmed HMC with a transverse vaginal septum. X-rays of the hand and foot showed bony fusion of the left third and fourth metacarpal bones, right fourth dysplastic metacarpal bone and phalanx, right PAP and hypoplastic left foot with left fourth and fifth dysplastic metatarsal bones. In addition, she had soft palate cleft, mild hydronephroses of both kidneys, hypoplastic right kidney with ectopic location and mild rotation, uterine didelphys with transverse vaginal septum and low-type imperforated anus. She was temporarily treated with ultrasound-guided transurethral aspiration of the HMC. Our patient with HMC and PAP was diagnosed with MKS because she has two typical abnormality of MKS and she has no definite complications of retinal disease, learning disability, obesity and renal failure that develop in Bardet-Biedl syndrome, but not in MKS until 33 months of age. Here, we describe a case of a Korean patient with MKS.

A sclerosing stromal tumor of the ovary with masculinization in a premenarchal girl

  • Park, Soo-Min;Kim, Young-Nam;Woo, Young-Jong;Choi, Ho-Sun;Lee, Ji-Shin;Heo, Suk-Hee;Kim, Chan-Jong
    • Clinical and Experimental Pediatrics
    • /
    • v.54 no.5
    • /
    • pp.224-227
    • /
    • 2011
  • A sclerosing stromal tumor of the ovary is an extremely rare benign tumor; it usually is found during the second and third decades of life. Patients present with pelvic pain or a palpable abdominal mass. Hormonal effects such as masculinization are uncommon. Here, an 11-year old premenarchal girl presented with deepening of the voice. In addition, clitoromegaly and hirsutism with a male suprapubic hair pattern were observed. The laboratory findings showed that the testosterone level was elevated to 3.67 ng/ml, andostenedione to above 10 ng/ml, dehydroepiandrosterone-sulfate to 346 ${\mu}g$/dl and 17-hydroxy progesterone (17-OHP) to 11.28 ng/ml. The chromosome evaluation revealed a 46,XX female karyotype. An adrenocorticotropic hormone stimulation test was performed. The 17-OHP to cortisol ratio in 30 minutes was 0.045, which suggested a heterozygote for the 21-hydroxylase deficiency. However, the CYP21A2 gene encoding steroid 21-hydroxylase showed normal. The pelvic ultrasound showed a heterogeneous mass consisting of predominantly solid tissue in the pelvic cavity. The pelvic magnetic resonance imaging revealed an $8.9{\times}6.2{\times}6.6$ cm mass of the left ovary. A left oophrectomy was performed and microscopic examination confirmed a sclerosing stromal tumor. Immunohistochemical studies showed that the tumor was positive for smooth muscle actin and vimentin, but negative for S-100 protein and cytokeratin. Following surgery, the hormone levels returned to the normal range and the hirsutism resolved.

Survey for Needs of Bio-Signal Devices for the Diagnosis, Assessment, or Analysis of Neurocognitive Disorder in Korean Society of Oriental Neuropsychiatry (인지 장애 진단·평가·분석을 위한 생체신호 장비 개발에 대한 수요조사: 한방신경정신과학회 회원들을 대상으로)

  • Choi, Yujin;Kim, Ji Hye;Kim, Kahye;Kim, Jaeuk
    • Journal of Oriental Neuropsychiatry
    • /
    • v.31 no.2
    • /
    • pp.89-99
    • /
    • 2020
  • Objectives: The purpose of this study was to identify the needs of bio-signal devices for the diagnosis, assessment, and analysis of neurocognitive disorder in Korean medicine (KM) hospitals and clinics. Methods: A questionnaire was developed to survey the current status of medical device use, and diagnosis and interventions for patients with cognitive disorders in KM hospitals and clinics. November 11~December 2, 2019, 114 responses (71.9% completed) were collected by internet-based questionnaires from the members of the Korean society of Oriental Neuropsychiatry. Results: The clinical requests were in the descending order of hematology analyzer, ultrasound imaging system, and electroencephalography among the 15 most commonly used devices of which research would support for their clinical usability. The biosignal-based devices showed the highest research demands for patients with mild cognitive impairment rather than more severe stages of cognitive impairment. Prevention rather than diagnosis, or several treatment regimens was the strongest clinical area of the KM for patients with neurodegenerative cognitive impairment. Many responded that five to 10 minutes of test duration and 20,000 won to 30,000 won of cost would be appropriated for a new device to be developed. Conclusions: There were strong demands for the development of bio-signal devices for neurocognitive disorders among the KM doctors. Specifically, it showed high needs for the technology that can be used in the prevention area of cognitive disorders. Additionally, new medical devices to assess cognitive functions and to obtain KM pattern-related information were the high needs.

Accuracy of Intraoperative Gross Examination of Myometrial Invasion in Stage I-II Endometrial Cancer

  • Sethasathien, Prauk;Charoenkwan, Kittipat;Siriaunkgul, Sumalee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.17
    • /
    • pp.7061-7064
    • /
    • 2014
  • Background: To assess the sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of intraoperative gross examination (IGE) of uterine specimens in determining deep myometrial invasion and cervical invasion compared to final histology. Materials and Methods: The clinical, surgical and histological data of all FIGO stage I-II endometrial cancer (EC) patients who had primary surgery were reviewed. Results of the IGE for myometrial invasion and cervical invasion were compared to the final histology. The sensitivity, specificity, PPV, NPV, and accuracy of the IGE in determining deep myometrial invasion and cervical invasion were calculated. Association between clinico-pathological factors and discrepancy between IGE and final histology in the determination of myometrial invasion was also assessed. A p-value of <0.05 was considered significant. Results: From January 2007 to December 2012, 179 patients diagnosed with clinical stage I-II endometrial cancer underwent surgical staging. The sensitivity and specificity of IGE in detecting deep myometrial invasion were 42.4% and 90.0%, respectively, and the PPV and NPV were 67.6% and 76.1%. The overall accuracy of IGE was 74.3%. The sensitivity and specificity of IGE in identifying cervical invasion were 28.6% and 97.5%, respectively, while the PPV and NPV were 60.0% and 91.1%. The overall accuracy of IGE was 89.4%. Conclusions: The sensitivity of IGE for detecting deep myometrial invasion and cervical invasion in early-stage EC is too low to be used alone. Alternative methods including intraoperative frozen section analysis, preoperative three dimensional ultrasound, and preoperative magnetic resonance imaging should be strongly considered.

A study of the high resolution Ultrasound Diagnostic system for Dermatology (피부학(Dermatology)을 위한 고해상도 초음파 진단 장치에 관한 연구)

  • Lew, Jeom-Soo;Lim, Chun-Sung;Kim, Young-Kil
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.6
    • /
    • pp.66-71
    • /
    • 1998
  • High spatial resolution ultrasonic imaging is necessary in several fields of investigation, in order to permit greater precision of clinical diagnosis in the dermatology, ophthalmology etc. We present a B-mode scan system using sector scanning probe of 20MHz center frequency. This developed system allow the high resolution image of 250${\mu}m$ in lateral and 80${\mu}m$ in axial, which of display the size of a $5mm {\times} 5mm$ image with 20 frames/sec. We have shown the images of various structural elements of the human skin and of the nail. We have compared the skin images obtained for each of the different age and we have shown in a general with the age, the atrophy of the skin thickness and the appearance of the abnormal hypoechogene band under epidermis (named SENEB : Sub Epidermal Non Echogene Band).

  • PDF

Extraction of Lumbar Multifidus Muscle using Ultrasound Imaging (초음파 영상에서 다열근 추출)

  • Kim, Kwang-Baek;Shin, Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • In this paper, we propose a new method for extracting muscles from lumbar images. The proposed method sets areas without distortions with field expert's assistance as areas of measuring interest and removing noises from initial ultrasonic videos. Then, the method emphasizes the brightness contrast with Ends-in search stretching algorithm and separate thoracic vertebra from subcutaneous fat area using morphological characteristics. 4-directions contour tracing algorithm is applied to extract the bottom of subcutaneous fat area. Extracting thoracic vertebra area requires noise removal and morphological characteristics as well among candidate areas obtained by controlling min-max brightness. The thickness of muscles is then defined as the length between subcutaneous fat area and extracted thoracic vertebra. The experiment which consists of 368 image analysis verifies that the proposed method is more effective in measuring the thickness of muscles than before.

Intra- and inter-rater reliability of muscle thickness measurement of the tibialis anterior using different inward pressures

  • Lee, Seong-Joo;Lim, Ji Young;Lee, Chang-Hyung;Park, Dae-Sung
    • Physical Therapy Rehabilitation Science
    • /
    • v.8 no.4
    • /
    • pp.218-224
    • /
    • 2019
  • Objective: This reliability study examined the effects of applying varying induced inward pressures using a transducer placed at 0° neutral ankle position (NEU) and 15° ankle dorsiflexion (DF) on tibialis anterior (TA) muscle thickness using a custom-made device with a force indicator during rehabilitative ultrasound imaging. Design: Cross-sectional study. Methods: Twenty-four healthy subjects were recruited in this study. Two examiners measured the muscle thickness of the TA at 0° NEU and 15° DF in 3 conditions of inward pressures (1.0 N, 2.0 N, and 4.0 N) using a custom-made holder. The muscle thickness was measured three times for each of the conditions arranged in random order. For intra- and inter-rater reliability, the intraclass correlation coefficients (ICCs) with 95% confidence intervals, standard error of measurement, minimal detectable change, and coefficient of variation were analyzed. One-way repeated measures analysis of variance was conducted for investigating changes of TA muscle thickness according to the inward pressures of the transducers. Results: The intra-rater reliability of TA muscle thickness measurement was excellent (ICC3,1: 0.92-0.96) for all conditions (at both ankle joint angles per varying inward pressure). Likewise, the inter-rater reliability of TA muscle thickness measurement was excellent (ICC2,1: 0.89-0.97) under same conditions. The mean of TA thickness showed the trend of decreasing significantly with increased inward pressures at all ankle joint angles (p<0.05). Conclusions: Use of this custom-made device with a force indicator is useful to accomplish the high intra- and inter-rater reliability of TA muscle thickness measurement at both ankle joint angles in reducing the measurement error.

Change of Muscle Thickness on Exercise Type of Core Stabilization in Aged Men (남성노인의 코어 안정화 운동 형태가 근 두께에 미치는 영향)

  • Lim, Chaegil
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.8 no.1
    • /
    • pp.67-76
    • /
    • 2020
  • Purpose : The purpose of this study was to provide more effective interventions for elderly men with weak core muscles by measuring the thickness of the muscles according to the five core stabilization exercise and comparing the thickness differences in muscles in each posture. Methods : The study selected 29 elderly men aged 65 to 80 years old among outpatient patients at S Medical Center in B city, and measured the muscle thickness by exercise posture once. In order to find out the thickness of the external oblique (EO), internal oblique (IO), and transverse abdominis (TrA) muscles were measured by using rehabilitative ultrasound imaging (RUSI) in five exercise conditions. Results : A significant change in the thickness of the EO muscles in each group was measured by the method of motion, followed by the abdominal crunches (1.67±0.15), the lower body rotations (1.54±0.07). As a result of measuring the thickness of the IO muscles of each group according to the exercise method, the bridge group (1.14±0.22) was the highest, followed by the abdominal drawing group (1.05±0.03). As a result of measuring the thickness of the TrA muscles of each group according to the exercise method, the abdominal crunches (0.98±1.00) were the highest, and the bridge group (0.57±0.05) were higher in order of magnitude. Conclusion : Consequently, the five core stabilization exercises all affect changes in abdominal thickness and are expected to continue to require training studies on muscle posture.

US-guided 14G Core Needle Biopsy: Comparison Between Underestimated and Correctly Diagnosed Breast Cancers

  • Kim, Hana;Youk, Ji Hyun;Kim, Jeong-Ah;Gweon, Hye Mi;Jung, Woo-Hee;Son, Eun Ju
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.7
    • /
    • pp.3179-3183
    • /
    • 2014
  • Background: The purpose of study was to evaluate radiologic or clinical features of breast cancer undergoing ultrasound (US)-guided 14G core needle biopsy (CNB) and analyze the differences between underestimated and accurately diagnosed groups. Materials and Methods: Of 1,898 cases of US-guided 14G CNB in our institute, 233 cases were proven to be cancer by surgical pathology. The pathologic results from CNB were invasive ductal carcinoma (IDC) (n=157), ductal carcinoma in situ (DCIS) (n=40), high-risk lesions in 22 cases, and benign in 14 cases. Among high-risk lesions, 7 cases of atypical ductal hyperplasia (ADH) were reported as cancer and 11 cases of DCIS were proven IDC in surgical pathology. Some 29 DCIS cases and 157 cases of IDC were correctly diagnosed with CNB. The clinical and imaging features between underestimated and accurately diagnosed breast cancers were compared. Results: Of 233 cancer cases, underestimation occurred in 18 lesions (7.7%). Among underestimated cancers, CNB proven ADH (n=2) and DCIS (n=11) were diagnosed as IDC and CNB proven ADH (n=5) were diagnosed at DCIS finally. Among the 186 accurately diagnosed group, the CNB results were IDC (n=157) and DCIS (n=29). Comparison of underestimated and accurately diagnosed groups for BI-RADS category, margin of mass on mammography and US and orientation of lesion on US revealed statistically significant differences. Conclusions: Underestimation of US-guided 14G CNB occurred in 7.7% of breast cancers. Between underestimated and correctly diagnosed groups, BI-RADS category, margin of the mass on mammography and margin and orientation of the lesions on US were different.