• Title/Summary/Keyword: ultrasound imaging

Search Result 679, Processing Time 0.028 seconds

Ultrasound-guided intraoral botulinum toxin injection into the lateral pterygoid muscle for chronic temporomandibular joint dislocation

  • Sung-Tak Lee;Dohyoung Kim;Jae-Hyeong Park;Tae-Geon Kwon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.50 no.1
    • /
    • pp.41-48
    • /
    • 2024
  • Objectives: Botulinum toxin type A (BTX), a powerful neurotoxin, can be an effective treatment choice for diverse muscular disorders and can reduce abnormal muscle activities. Abnormal movements of the mandible can be caused by involuntary and uncontrolled contractions of the lateral pterygoid muscle (LP) in various pathological situations. Previous reports have shown that BTX can reduce abnormal contractions of the LP. However, needle placement into the LP for BTX injection requires skill, experience, and sufficient anatomical knowledge. To place the needle precisely into the LP, ultrasonography (USG) can be used as an effective needle-guidance modality. USG is a non-invasive imaging modality able to create real-time images without any potential risks, including radiation exposure. Patients and Methods: The patients who had been performed USG-guided BTX injection into the LP using an intraoral approach were included in this study with a literature review and case presentations. Using the USG, four patients received BTX injections to treat recurrent temporomandibular dislocation and oromandibular dystonia resulting from involuntary LP activity. Result: Involuntary movements of the mandible were improved successfully in all patients, and showed satisfactory results without significant complication. Conclusion: The intraoral approach could prevent potential complications during needle placement. USG-guided BTX injection is an effective, convenient, and safe method that provides real-time imaging without unnecessary pain to the patient.

Rapid Local Recurrence of Breast Myoepithelial Carcinoma Arising in Adenomyoepithelioma: A Case Report (빠른 국소 재발을 보인 유방의 선근상피종에서 발생한 근상피암: 증례 보고)

  • Mo In Ha;Bo Kyoung Seo;Jung Woo Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.207-212
    • /
    • 2020
  • Adenomyoepithelioma (AME) is a rare breast neoplasm composed of both epithelial and myoepithelial cells with biphasic proliferation. Although most AMEs are benign, malignant transformation of either or both cellular components may occur. This report describes an unusual rapid local tumor recurrence a month after excision of the myoepithelial carcinoma arising in an AME. Ultrasound and MRI showed small recurrent masses in the superficial part of a hematoma. This report suggests the benefit of immediate postoperative breast imaging in patients with malignant AME with potential for local recurrence, such as those with narrow resection margins or high mitotic activity.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

A Performance Improvement of Ultrasonic Diagnosis Transducer by Transient Acoustic Field Analysis (과도음장 해석을 통한 초음파 진단 탐촉자의 성능 개선)

  • 박은주;송행용;김무준;김동현;이수성;하강열
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.8
    • /
    • pp.744-756
    • /
    • 2002
  • The transient acoustic fields formed by a 3.5 ㎒ curved linear array transducer which is commonly used in ultrasonic medical imaging system for diagnosis of abdomen are systematically analyzed to obtain new design parameters for the better acoustic image. In the analysis with an assumption of radiating waveform, element size, radius of curvature, amplitude apodization are considered as parameters giving constitutive relations with the fields. As simulation results, appropriate new parameters with the reduced curvature and elevation aperture and the apodization of Hamming window, which make an improved acoustic beam with lower side lobe levels than a conventional typical transducer, are obtained.

A Case of Pulmonary Sequestration Diagnosed by Doppler Sonography (도플러초음파로 진단한 폐분리증 1례)

  • Kwon, Sung-Ho;Ha, Hyoung-Keun;Chung, Myoung-Jin;Park, Man-Sil;Bae, In-Kyu;Kim, Sang-Hoon;Ahn, Young-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.1
    • /
    • pp.66-70
    • /
    • 2002
  • Pulmonary Sequestration is a rare congenital malformation during embryouic development which results in a cystic mass of nonfunctioning lung tissue. A diagnosis of a pulmonary sequestration has traditionally relied upon identifying the pathological arterial vessels by arteriography, computed tomography, and magnetic resonance imaging. We reported a case of pulmonary sequestration diagnosed by Doppler sonography and subsequent CT angiography. A 21-year-old-woman admitted to hospital for an investigation of recurrent pneumonia with left lower chest pain. A doppler ultrasound sonography showed an aberrant blood supply from the descending thoracic aorta to the left lower chest lesion. The pulmonary sequestration was confirmed by the subsequent CT angiograph.

Imaging Characteristics of Perosomus elumbis in a Puppy

  • Choi, Sooyoung;Lee, Byungho;Lee, Byungdon;Seo, Jiwon;Park, Hyunyoung;Kwon, Kyunghun;Lee, Youngwon;Choi, Hojung
    • Journal of Embryo Transfer
    • /
    • v.30 no.4
    • /
    • pp.341-344
    • /
    • 2015
  • A 4-day-old, male Poodle dog was presented with dull, depressed and exhausted activity after the birth. On physical examination, the puppy showed arthrogryposis, muscular atrophy and no movement of hindlimbs. Palpation on dorsum revealed an absence of lumbar and sacral vertebrae. On prenatal and postnatal radiography, lumbar vertebrae, sacrum and coccygeal vertebrae were not visualized. On ultrasonography, bilateral kidney and urinary bladder were observed. On computed tomography, there were no apparent abnormalities in the forelimbs, cervical vertebrae or head, while lumbar vertebrae, sacrum and coccygeal vertebrae were not observed. At necropsy examination, the liver, stomach, intestine, kidney and urinary bladder were normal. This congenital anomaly was consistent with Perosomus elumbis. Perosomus elumbis in dogs is a rare condition of unknown etiology. In this report, Perosomus elumbis was evaluated with radiography, ultrasound and computed tomography.

Diagnostic Consistency between Sonoelastography and Conventional Sonography of Long Head of the Biceps

  • Yoon, Sunghyun;Seo, Joong-Bae;Yoo, Jae-Sung;Ryu, Jee-Won
    • Clinics in Shoulder and Elbow
    • /
    • v.17 no.3
    • /
    • pp.107-113
    • /
    • 2014
  • Background: Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness, the purpose of this study was to evaluate the ability of SE to assess the long head of biceps tendon alteration. Methods: Forty shoulders of 36 consecutively registered patients with clinical symptoms and conventional ultrasonography findings of biceps tendinitis or tendinosis, and 40 asymptomatic shoulders of 20 healthy volunteers were assessed with SE. Transverse and longitudinal images of long head of biceps tendon were obtained using SE. SE images were performed by one orthopedic surgeon and evaluated by two orthopedic surgeons using an experimentally proven color grading system. Results: The transverse images of SE showed a sensitivity of 87.5%, a specificity of 95.0% and a accuracy of 91.3%, the longitudinal images of SE showed a sensitivity of 92.5%, a specificity of 90.0% and a accuracy of 91.3%. Inter-observer reliability of SE was in 'almost perfect agreement' with a weighted kappa coefficient of 0.83. Conclusions: SE is valuable in the detection of the intratendinous and peritendinous alterations of biceps tendon, and has excellent accuracy and excellent correlation with conventional ultrasound findings.

A Case of Infantile Hemangioendothelioma of the Liver Treated with Hepatic Embolization and Lobectomy (간동맥 색전술과 간엽 절제술로 치료한 영아 간내 혈관내피종 1례)

  • Kim, Jae Seon;Moon, Soo Kyung;Yoon, Hye Seon;Lee, Tae Seok
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.6
    • /
    • pp.660-664
    • /
    • 2005
  • Infantile hemangioendothelioma(IHE) of the liver is the most common vascular tumor in infants before the age of 6 months. It is a histologically benign tumor with potentially life-threatening complications. The clinical manifestations are variable, ranging from asymptomatic forms to intractable high-output heart failure. In addition, abdominal mass, intraperitoneal hemorrhage due to rupture of mass, respiratory distress, hematologic abnormalities and jaundice can occur. Diagnostic work-up is through doppler ultrasound sonography, computed tomography scan, magnetic resonance imaging and angiography. Treatment consists of medical treatment, interventional therapy, surgical resection and liver transplantation. We experienced symptomatic IHE in a premature neonate who presented with high output heart failure and respiratory distress. Initial medical treatment and steroid therapy failed to improve his condition. Coil embolization of left hepatic artery resulted in improvement of respiratory symptoms. However, a left lobectomy was performed because the mass size was not decreased with development of collateral vessels. The infant was well, after a successful discharge from the hospital.

Challenges in neuro-machine interaction based active robotic rehabilitation of stroke patients

  • Song, Aiguo;Yang, Renhuan;Xu, Baoguo;Pan, Lizheng;Li, Huijun
    • Advances in robotics research
    • /
    • v.1 no.2
    • /
    • pp.155-169
    • /
    • 2014
  • Study results in the last decades show that amount and quality of physical exercises, then the active participation, and now the cognitive involvement of patient in rehabilitation training are known of crux to enhance recovery outcome of motor dysfunction patients after stroke. Rehabilitation robots mainly have been developing along this direction to satisfy requirements of recovery therapy, or focusing on one or more of the above three points. Therefore, neuro-machine interaction based active rehabilitation robot has been proposed for assisting paralyzed limb performing designed tasks, which utilizes motor related EEG, UCSDI (Ultrasound Current Source Density Imaging), EMG for rehabilitation robot control and feeds back the multi-sensory interaction information such as visual, auditory, force, haptic sensation to the patient simultaneously. This neuro-controlled and perceptual rehabilitation robot will bring great benefits to post-stroke patients. In order to develop such kind of robot, some key technologies such as noninvasive precise detection of neural signal and realistic sensation feedback need to be solved. There are still some grand challenges in solving the fundamental questions to develop and optimize such kind of neuro-machine interaction based active rehabilitation robot.

Diagnostic Imaging Features of Abdominal Foreign Body in Dogs; Retained Surgical Gauze (개에서 복강내 잔존한 거즈 이물의 진단영상)

  • Choi, Ji-Hye;Kim, Gye-Dong;Keh, Seo-Yeun;Jang, Jae-Yong;Choi, Hee-Yeon;Yoon, Jung-Hee
    • Journal of Veterinary Clinics
    • /
    • v.28 no.1
    • /
    • pp.94-100
    • /
    • 2011
  • This study was performed to describe the radiographic and ultrasonographic features of retained surgical gauze known as gossypiboma in 9 dogs. Female dogs (n = 8) were at higher risk and seven out of the eight cases had a history of ovariohysterectomy. Seven dogs were symptomatic and the most common clinical signs were vomiting, anorexia, and inertia. A palpable abdominal mass was detected in six dogs. Radiographic signs included a localized abdominal mass with soft tissue density (n = 7) or a mass containing speckled gas (n = 1). Ultrasonography showed a hypoechoic mass with a hyperechoic center (n = 4), or a homogeneous hypoechoic mass (n = 3). The remaining dogs (n = 2) showed an intestinal wall surrounding a hyperechoic center. Regardless of the characteristics of a mass, an acoustic shadowing was accompanied from the center of a mass in all dogs. Ultrasonography also revealed complications such as adhesion between a mass and adjacent organs, and peritonitis and intestinal obstruction around a mass. The gossypiboma can be considered when a hypoechoic mass accompanying a hyperechoic center with acoustic shadowing is observed on ultrasound examination.