• Title/Summary/Keyword: ultrasound horn

Search Result 18, Processing Time 0.035 seconds

Characteristics on Temperature Evolution in the Metallic Specimen by Ultrasound-Excited Thermography

  • Choi, M.Y.;Park, J.H.;Kang, K.S.;Kim, W.T.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.3
    • /
    • pp.200-206
    • /
    • 2010
  • In ultrasound-excited thermography, the injected ultrasound to an object is transformed to heat and the appearance of defects can be visualized by thermography camera. The advantage of this technology is selectively sensitive to thermally active defects. Despite the apparent simplicity of the scheme, there are a number of experimental considerations that can complicate the implementation of ultrasound excitation thermography inspection. Factors including acoustic horn location, horn-crack proximity, horn-sample coupling, and effective detection range all significantly affect the detect ability of this technology. As conclusions, the influence of coupling pressures between ultrasound exciter and specimen was analyzed, which was dominant factor in frictional heating model.

An Immunohistochemical Study of Effects of Therapeutic Ultrasound on the Expression of Substance-P in Muscle Contusion Injury (근타박상시 치료용 초음파가 Substance-P 발현에 미치는 효과에 대한 면역조직화학적 연구)

  • Kim Yong Su;Kim Seok Beom;Kim Jin Sang;Park Rae Jun
    • The Journal of Korean Physical Therapy
    • /
    • v.15 no.1
    • /
    • pp.9-25
    • /
    • 2003
  • The purpose of this study was to evaluate the effect of therapeutic ultrasound after muscle contusion injury by observed immunoreactivity of substance-P that plays an important role in pain transmission. Ultrasound irradiation(1MHz, 1W/$cm^{2}$ continuous mode, treatment time 5 min) was applied through water submersion technique to 1 limb daily by kept off 5cm from muscle belly of gastrocnemius. The result of this study were as follows. 1. The substance-P was expressed in lamina I and II of dorsal horn of spinal cord, also in lamina IV and around of central cannel of spinal cord. Experimental group was lower expressed than control group with the exception of 1 days. 2. The substance-P immunoreactivity was decreased for 5 days together in lumbar and sacral region of all groups, expecially experimental group was rapidly. These data suggest therapeutic ultrasound may stimulate pain relief by diminish of substance-P in dorsal horn of spinal cord.

  • PDF

The Effect of Ultrasound Irradiation on the Neural Cell Adhesion Molecules(NCAM) Expression in Rat Spinal Cord after the Sciatic Nerve Crush Injury (초음파가 흰쥐의 좌골신경 압좌손상 후 척수내 Neural Cell Adhesion Molecules의 발현에 미치는 영향)

  • Kim, Hyun-Ae;Han, Jong-Man
    • The Journal of Korean Physical Therapy
    • /
    • v.19 no.2
    • /
    • pp.41-55
    • /
    • 2007
  • Purpose: This study aimed to compare the effect on nerve regeneration of ultrasound irradiation in rats with peripheral nerve injury. Methods: To investigate alterations of the NCAM immunoreactivity in non-crushed part and crushed part of the spinal cord, the unilateral sciatic nerve of the rats were crushed. The expression of NCAM was used as the marked of peripheral nerve regeneration, and also plays an important role in developing nerve system. Experimental animals were sacrificed by perfusion fixation at post-injury 1, 3, 7, 14 days after ultrasound irradiation. The pulsed US was applied at a frequency of 1MHz and a spatial average-temporal average Intensity of 0.5W/of (20% pulse ratio) for 1 mins. The Luxol fast blue-cresyl violet stain were also done to observe the morphological changes. Results: Alteration of NCAM immunoreactivity in the crushed part and the non-crushed part of lower lumbar spinal cord were observed. NCAM-immunoreactivity cells were some increased in the dorsal horn lamina I, III and cell ventral horn at 1 day after unilateral sciatic nerve injury. However, there was not significant difference in the relationship between crushed part and non-crushed part. NCAM-inmmunoreactivity was remarkably increased at 3 days after unilateral sciatic nerve injuryin the gray matter and white matter. NCAM-immunoreactivity was increased in the ventral horn and post horn of experimental crushed part. Also, NCAM-immunoreactivity in large motor neurons in ventral horns lamina VIII, IX were increased at 7 days after unilateral sciatic nerve injury. At 14 days after sciatic nerve crushed injury, there was no significant difference. All group were decreased for 14 days. In the time course of NCAM expression, all groups showed a significant difference at 3day groups(p<0.05). Whereas, CC group was noted a significant difference between 3day and 7 day group respectively. In NCAM expression, there were significantly increased in all group. In the relationship between CNC group and ENC group, significant difference was detected among 3, 7, 14 day group(p<0.05). The difference between CC group and ENC group were noted in all groups(p<0.05). Conclusion: It is consequently suggested that the effects of the ultrasound irradiation may increase the NCAM immunoreactive neurons and glial cell in the spinal cord after unilateral sciatic nerve crushed injury. Therefore, the increased NCAM immunoreactivity in the spinal cord may reflect the neuronal damage and healing process induced by a ultrasound irradiation after peripheral nerve injury in rat.

  • PDF

Defect Detection of Carbon Steel Pipe Weld Area using Infrared Thermography Camera (적외선 열화상 카메라를 이용한 탄소강관 용접부 결함검출)

  • Kwon, DaeJu;Jung, NaRa;Kim, JaeYeol
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.124-129
    • /
    • 2014
  • The piping system accounts for a large portion of the machinery structure of a plant, and is considered as a very important mechanical structure for plant safety. Accordingly, it is used in most energy plants in the nuclear, gas, and heavy chemical industries. In particular, the piping system for a nuclear plant is generally complicated and uses the reactor and its cooling system. The piping equipment is exposed to diverse loads such as weight, temperature, pressure, and seismic load from pipes and fluids, and is used to transfer steam, oil, and gas. In ultrasound infrared thermography, which is an active thermography technology, a 15-100 kHz ultrasound wave is applied to the subject, and the resulting heat from the defective parts is measured using a thermography camera. Because this technique can inspect a large area simultaneously and detect defects such as cracks and delamination in real time, it is used to detect defects in the new and renewable energy, car, and aerospace industries, and recently, in piping defect detection. In this study, ultrasound infrared thermography is used to detect information for the diagnosis of nuclear equipment and structures. Test specimens are prepared with piping materials for nuclear plants, and the optimally designed ultrasound horn and ultrasound vibration system is used to determine damages on nuclear plant piping and detect defects. Additionally, the detected images are used to improve the reliability of the surface and internal defect detection for nuclear piping materials, and their field applicability and reliability is verified.

Emulsion Polymerization of Octamethylcyclotetrasiloxane under Ultrasonic Irradiation (고강도 초음파를 이용한 Octamethylcyclotetrasiloxane의 에멀전 중합)

  • Kim, Jihye;Kim, Yubin;Kim, Hyungsu
    • Applied Chemistry for Engineering
    • /
    • v.20 no.3
    • /
    • pp.322-328
    • /
    • 2009
  • Emulsion polymerization of octamethylcyclotetrasiloxane (OMCTS) was conducted under ultrasonic irradiation. Two sources of ultrasound with different intensities and frequencies of 20 KHz and 40 KHz were used for horn and bath type reactor, respectively. A combined process of horn and bath was also investigated. The effectiveness of the reaction systems was investigated by measuring conversion as well as intrinsic viscosity of the products. The influence of reaction temperature and sonication time on the progress of sonochemical polymerization was examined. It was found that conversion of greater than 80% and high viscosity were achieved within a few minutes of sonication in a horn type reactor, however, conversion and viscosity showed maximum values depending upon the sonication time. In a bath type reactor where a relatively weak intensity was maintained, longer duration time of more than one hour of sonication was required to reach a high level of conversion and viscosity. Compared with the horn type system, the conversion and viscosity in the bath type reactor were increased along with the sonication time. When the polymerization was carried out in a combined system of horn and bath, the evolution of conversion and molecular weight was quite different from the other cases. For the given geometry of reaction system, acoustic analysis using a commercial software was carried out and the results were correlated with experimental observation.

Extraction of Useful component from Natural plants using Ultrasound system (초음파 시스템을 이용한 천연물로부터 유용성분의 추출)

  • Lee, Kwang-Jin;Um, Byung-Hun
    • KSBB Journal
    • /
    • v.23 no.2
    • /
    • pp.101-108
    • /
    • 2008
  • Ultrasound assisted extraction (UAE) process enhancement for food and allied industries are reported in this review. Recently ultrasound system has been used more frequently to extract drugs and natural substances. This modern emulsification, homogenization, particle size reduction and viscosity alteration methodologies require reliable tools that perform on a high level in terms of efficiency and reproducibility. Also, Ultrasound can enhance existing extraction processes and enable new commercial extraction opportunities and processes. Therefore, ultrasound technologies could have a strong presence in the future of the food industry.

Evolution of phase morphology and in-situ compatibilization of polymer blends during ultrasound-assisted melt mixing

  • Kim, Hyungsu;Ryu, Joung-Gul;Lee, Jae-Wook
    • Korea-Australia Rheology Journal
    • /
    • v.14 no.3
    • /
    • pp.121-128
    • /
    • 2002
  • A series of thermoplastic polymers and their blends were melt-processed with high intensity ultrasonic wave in an intensive mixer. For the effective transfer of ultrasonic energy, an experimental apparatus was specially designed so that polymer melt can directly contact with ultrasonic horn. It was observed that significant variations in the rheological properties of polymers occur due to the unique action of ultrasonic wave without any aid of chemical additives. It was also found that the direct sonication on immiscible polymer blends in melt state reduces the domain sizes considerably and stabilizes the phase morphology of the blends. The degree of compatibilization was strongly affected by viscosity ratio of the components and the morphology was stable after annealing in properly compatibilized blends. It is suggested that ultrasound assisted melt mixing can lead to in-situ copolymer formation between the components and consequently provide an effective route to compatibilize immiscible polymer blends.

A Study on Wear-type Defects of Part and Materials in Wind Power Generation (풍력발전기 부품소재의 마모결함 검출에 관한 연구)

  • Kim, Sung-Hyun;Choi, Seung-Hyun;Jung, Na-Ra;Yoon, Cheon-Han;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.22 no.6
    • /
    • pp.989-995
    • /
    • 2013
  • Unlike fossil-or nuclear fuel-based power generation, wind power generation using inexhaustible wind energy is a pollution-free, hazardless power generation method. In this study, ultrasound thermography is used for fabricating specimens of wind power generator bearings and wind power generator supplement flanges, and an optimally designed ultrasound horn and ultrasound excitation system are used for detecting damage to part materials of a wind power generation setup. In addition, thermal flow analysis and ultrasonic thermography imaging are comparatively analyzed for improving the detection reliability in terms of surface and internal defects of part materials and for verifying the developed system's field applicability and reliability.

Reduction of Twin Pregnancy by Transvaginal Ultrasound-guided Aspiration in a Mare

  • Lee, Eun-bee;Song, Mingeun;Park, Chull-gyu;Hwang, Jun-seok;Chun, Yong-woo;Lee, Seung-hwan;Cheong, Jongtae;Lee, Joomyoung;Kang, Tae-Young;Seo, Jong-pil
    • Journal of Veterinary Clinics
    • /
    • v.34 no.4
    • /
    • pp.304-306
    • /
    • 2017
  • A 3-year-old Thoroughbred mare was referred to J&C Equine Hospital with gestation day 30 twin pregnancy. On transrectal ultrasonographic examination, two similar sized (28 mm) embryonic vesicles, unilaterally fixed in the uterine horn, were detected. Transvaginal ultrasound-guided aspiration (TUGA) was performed for reduction of one embryonic vesicle. Yolk sac and allantoic cavity fluids from one embryonic vesicle were aspirated by a needle guided by using transvaginal ultrasound. The mare continued normal singleton pregnancy after twin reduction and delivered a foal successfully. This is the first case described the clinical use of TUGA in Korea. Clinical use of TUGA in twin reduction after embryonic fixation is recommended for equine clinicians.

The Effects of c-Fos Expression on Ultrasound Treatment in Sciatic Nerve Crush Damaged Rats (초음파 치료가 좌골신경 압좌 손상된 흰쥐의 c-Fos 발현에 미치는 영향)

  • Kim, Dong-Dae
    • Journal of Korean Physical Therapy Science
    • /
    • v.14 no.1_4
    • /
    • pp.11-23
    • /
    • 2007
  • This study was performed to evaluate the effects of low-intensity ultrasound application to the peripheral nerve injury animal model on enhancement of nerve regeneration and functional recovery. Using aseptic microsurgical techniques, the sciatic nerve of adult male Sprague-Dawley rats was crushed at the outside of right mid-thigh for 30 seconds with fine forceps. Beginning just after surgery, various continuous-wave ultrasound treatments with intensities of 0.2 W/$cm^2$, 0.5 W /$cm^2$ and 1.0 W /$cm^2$ operated at 1 MHz or sham treatment were applied to the opposite inside of the crush site for 1 minute every other day with a transducer moving speed of 2cm/sec. For evaluation of the progress of sciatic nerve regeneration, c-Fos expression in the lumbar spinal cord (L4-5) dorsal horn was investigated. c-fos expression was markedly increased at 1hour after sciatic nerve crush injury, then gradually decreased thereafter. The c-fos expressions were significantly decreased (p<0.05) in all the experimental groups in comparison with the control group until 3days post-crush, and the degrees of decrease were higher in 0.5 W/$cm^2$ and 1 W/$cm^2$ intensity ultrasound application groups. It is suggested that low-intensity ultrasound application to an animal model of sciatic crush injury may suppress pain transmission and promote nerve regeneration, and which may result in delayed progress of muscle atrophy and accelerated progress of muscle recovery and eventually may result in accelerated and improved foot function recovery.

  • PDF