• 제목/요약/키워드: ultrasound guided aspiration

검색결과 81건 처리시간 0.024초

젖소의 초음파 유도 채란율에 대한 FSH 전처리 효과의 비교 (Effect of FSH Pretreatment on Follicle Development and Oocyte Recovery by Ultrasound-guided Aspiration in Holstein Heifers)

  • 박충생;조성근;이정규;강태영;박성재;공일근;최민철
    • 한국가축번식학회지
    • /
    • 제21권2호
    • /
    • pp.147-156
    • /
    • 1997
  • Ultrasound-guided follicular aspiration was performed in Holstein heifers once weekly with or without pretreatment of single or multiple decreasing doses using a total of 400 mg FSH. Oocytes were aspirated with a 6.5 MHz convex-array ultrasound trasducer designed for intravaginal use. All the visible follicles larger than 4 mm in diameter were punctured with a 17 gauge, 55 cm needle at each aspiration session and the follicular fluids containing oocytes were obtained by vacuum suction. The results obtained were as follows: As a preliminary experiment, the recovery rates of folicular oocytes by ultrasound-guided aspiration from the isolated ovaries of Korean native cows were compared between suction methods using manual syringe or vacuum pump. The recovery rate of oocytes using vacuum pump (80.7%) was significantly (P<0.05) higher than that using manual syringe (47.1%). The follicles were counted by their size in diameter with ultrasound image, and recovery rates and grades of follicular oocytes collected by ultrasound-guided aspiration were investigated in Holstein heifers pretreated with or without FSH. A group of heifiers were injected with multiple decreasing doses (twice a day for 3 days) of a total of 400 mg FSH. The other 2 groups were injected with a single dose of 400 mg FSH mixed with 25% PVP. Ultrasound observation of follicle population and/or ultrasound-guided transvaginal oocyte aspiration were performed 12 hrs following the last FSH injection in the multiple dose group, and 48 or 60 hrs after FSH injection in the single dose groups. Most of the visible follicles had small size of less than 3 mm in diameter in unstimulated heifers (71.0%), but medium size in all the heifers treated with FSH. (70.5 to 92.8%). The number of OPU follicles per session (4.6$\pm$1.9) were much less, compared to the vilsible follicle counts (9.7$\pm$2.2), in the nustimulated heifers due to the small dominant follicles. Among 4 goups of heifers the most visible as well as OPU follicles were observed in the heifers at 60 hrs following treatment of a single dose of 400 mg FSH (21.2$\pm$2.3 and 21.0$\pm$2.0), and the differences in both the follicle counts between the groups was found significant (P<0.05) The rates of oocyte recovery from the follicles by ultrasound-guilded aspiration were varied 46.3 to 75.0% in the heifers unstimulated and treated with a single dose of 400 mg FSH, but the group difference was not significant. The number of recovered oocytes per session a, pp.ared to be highest at aspiration at 60 hrs following single FSH (10.6$\pm$2.2) than at aspiration at 48 hrs after single FSH (7.8$\pm$2.7) or in the unstimulated heifers (3.4$\pm$3.0). The proportion of grade I and II oocytes to all oocytes collected was varied 31.8 to 64.0% between the groups. However, there was found no significant difference in both the number of oocytes recovered per session and the percentage and the percentage of grade I and II oocytes. From the above results it was concluded that the more oocytes of superior quality might be recovered economically by ultrasound-guided aspiration at 60 hrs following the pretreatment of a single dose of 400 mg FSH and by suction using a vacuum pump system of about negative pressure of 75 to 85 mmHg.

  • PDF

한우에서 초음파 유래와 도축장 유래 난포란을 이용한 체외 수정란 생산에 관한 연구 (Study on In Vitro Bovine Embryo Production with Follicular Oocytes Obtained via Ultrasound-guided Ovum Pick-up (OPU) and Slaughterhouse-derived(SHD) Ovary Aspiration in Korean Native Cows)

  • 손우진;강태영;조성근;심보웅;최민철;최상용;박충생;이효종
    • 한국수정란이식학회지
    • /
    • 제13권2호
    • /
    • pp.107-115
    • /
    • 1998
  • The present study was carried out for the comparative study on the collection of bovine follicular oocytes by ultrasound-guided ovum pick-up(OPU) and slaughterhouse-derived (SHD) ovary aspiration and in vitro production of bovine embryos with the follicular oncytes in Korean native cows. Bovine follicular nocytes were observed with a 6.5 MHz convex-array ultrasound transducer designed for intravaginal use and the oocytes were collected with the aspiration equipment attached to the ultrasonograph. Bovine ovaries were collected and transported in phosphate buffered saline from the local slaughterhouse, the follicular oocytes were collected by the aspiration method. The collected follicular oocytes in good quality were matured, fertilized and cultured in the media. The total number of the visible follicles and the recovery rate of follicular oocytes were increased in ultrasonography following follicle stimulating hormone(FSH) treatment in Korean native cows. The mean recovery rate of oocytes was 66.2, 52.8 and 41.7% in the FSH-OPU, non-treatment-OPU and SHD ovaries, respectively. The mean number of recorved oocytes per cow were not significantly(P<0.05) different between the FSH-OPU(14.0$\pm$11.54) and SHD(17.1i6.21) groups, but the numbers in both groups were significantly(P<0.05) higher than the number in the non-treatment-OPU(3.7$\pm$1.57) group. The mean number of usable nocytes in Grade T /11 per ovary was 6.3, 4.8 and 1.3 in the cows of the SHD, FSH-OPU and non-treatment-OPU groups, respectively. The in vitro developmental rate to the blastocyst was not significantly different between the oocytes obtained via OPU(37.1%) and SHD(29.3%). Therefore, the ultrasound-guided OPU technique can be applied to the production of excellent embryos from the high-quality cows, and for the large scale production of in vitro bovine oocytes and embryos, the SHD ovary aspiration method is valuable.

  • PDF

진균성 요근 농양의 초음파 유도하 경피적 천자술을 통한 성공적 치료 - 증례보고 - (Fungal Psoas Abscess Successfully Treated by Ultrasonographically Guided Percutaneous Aspiration - A Case Report -)

  • 문상호;김진학;이송;안동기;김대근
    • 대한정형외과 초음파학회지
    • /
    • 제5권1호
    • /
    • pp.36-40
    • /
    • 2012
  • 요근 농양은 전통적으로는 수술적 배농술이 많이 시도되고 있으나 초음파 유도하 경피적 천자술이 효과적인 치료방법이 될 수 있다. 그러나 아직까지 초음파를 이용한 천자술의 유용성에 대해서는 잘 확립되어 있지 않다. 저자들은 진균성 요근 농양을 초음파 유도하 경피적 천자술로 치유하였던 증례를 경험하였기에 문헌 고찰과 함께 보고하고자 한다. 배농은 초음파 영상 하에서 침 천자술로써, 시술로 인한 합병증의 발생 없이 시행하였다. 배농 후 배양에서 Candida Albicans가 동정되었으며 두 번의 천자술과 적절한 항진균제 치료로써 성공적으로 치유할 수 있었다.

  • PDF

비촉지성 갑상선 결절의 진단에서 초음파 유도하 세침검사법의 임상적 가치 (A Clinical Significance of Ultrasound Guided Aspiration Cytology in Diagnosis of Impalpable Thyroid Nodule)

  • 최낙선;윤정한;제갈영종
    • 대한두경부종양학회지
    • /
    • 제15권2호
    • /
    • pp.189-193
    • /
    • 1999
  • Objectives: Fine needle aspiration cytology(FNAC) is a well established preoperative diagnostic procedure in the thyroid nodules. However, diagnostic accuracy of FNAC varies according to the size and the structural characteristics of thyroid nodule. We performed the ultrasound guided FNAC(US-guided FNAC) for impalpable thyroid nodule, and estimated the sampling accuracy rate through a comparison study between the cytologic diagnosis and the final histologic diagnosis of the postoperative specimens in order to determine clinical efficacy of the US-guided FNAC. Materials and Methods: We evaluated 117 patients underwent US-guided FNAC from January 1997 to December 1998. These patients had 129 thyroid nodules to need cytologic examination. Whereas the nodules were so no graphically classified into cystic, solid, and mixed type according to echo pattern, the aspirated thyroid specimens were classified into benign, malignant, suspicious, and insufficient. Results: Positive sampling for diagnositc examination was achieved in 75 nodules(58.1%), and US-guided FNAC in our study showed the accuracy rate of 95.2%, false positivity rate of 0%, and false negativity rate of 5.5%. Conclusions: US-guided FNAC is a powerful techniques for evaluating cytologic characterics and allowing a reliable diagnositc result in the impalpable thyroid nodule. However, the experienced technique is recommanded in order to obtain the sufficient samples for reliable results.

  • PDF

I.V.F.를 위한 난자채취 방법의 비교연구 (A Comparative Study on Oocyte Retrieval for I.V.F.)

  • 김서경;김영태;김선행;나중열;구병삼
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제17권2호
    • /
    • pp.115-121
    • /
    • 1990
  • Ultrasonically guided oocyte collection gradually replaces laparoscope in many IVF center. In present study, we compare the efficacy of both methods in our IVF program. Totally 377 cycles which were undertaken in vitro fertilization treatment were divided into 2 groups. Ultrasonically guided transvaginal follicular aspiration was performed in 188 cycles and laparoscopic follicular aspiration was performed in 189 cycles under local anesthesisa. The mean age for both groups was similar. Follicular recruitment was achieved with human menopausal gonadotropin (hMG) or a com bination of clomiphene citrate and hMG or a combination of FSH and hMG. In the ultrasonically guided aspiration group, 1821 follicles were aspirated with 61.8% of recovery rate (1125 oocytes), 81.5% of embryo transfer rate (145 cycles) and (17%), 26 cases intrauterine pregnancies were estabilished. In the laparoscopic group, 604 follicles were aspirated with 68.7% recovery rate (445 oocytes) and a 79.9% ET rate (127 cycles), 11 cases (8.7%) intrauterine pregnancies were estabilished. A valid comparison of these data is not possible because the 2 groups are dissimilar for factors known to influence oocyte development and recovery. No statistically significant differences could be demonstrated between 2 groups in all but the recovery rate and clinical pregnancy rate, In ultrasound group, the clinical pregnancy rate was significantly higher than that of laparoscope group. The potentially detrimental effect of CO2 pnemoperitonium present during laparoscope but not in ultrasound guided recovery on ova quality may underlie the observed difference in the clinical pregnancy rate between the 2 groups. Ultrasound guided aspiration seems to be as effective as laparoscopy in terms of oocyte retrieval and conception rate. Furthermore, the procedure is simple and inexpensive, it may replace laparoscopy as a method for oocyte collection in most patients who undergo IVF.

  • PDF

Malignant Pleural Mesothelioma Diagnosed by Endobronchial Ultrasound- Guided Transbronchial Needle Aspiration

  • Kang, Byungju;Kim, Mi Ae;Lee, Bo Young;Yoon, Hwan;Oh, Dong Kyu;Hwang, Hee Sang;Choi, Changmin
    • Tuberculosis and Respiratory Diseases
    • /
    • 제74권2호
    • /
    • pp.74-78
    • /
    • 2013
  • A 61-year-old woman came to the hospital with dyspnea and pleural effusion on chest radiography. She underwent repeated thoracentesis, transbronchial lung biopsy, bronchoalveolar lavage, and thoracoscopic pleural biopsy with talc pleurodesis, but diagnosis of her was uncertain. Positron emission tomography showed multiple lymphadenopathies, so she underwent endobronchial ultrasound-guided transbronchial needle aspiration of mediastinal lymph nodes. Here, we report a case of malignant pleural mesothelioma that was eventually diagnosed by endobronchial ultrasound-guided transbronchial needle aspiration. This is an unusual and first case in Korea.

초음파유도 난포채란기의 개발과 이의 검증 (Development of needle guidance system and its evaluation for ultrasound-guided follicular aspiration)

  • 최민철;이효종;조성근;강태영;원현희
    • 대한수의학회지
    • /
    • 제39권6호
    • /
    • pp.1210-1217
    • /
    • 1999
  • This study was carried out to develop a newly designed ovum pick-up(OPU) instrument for ultrasound-guided transvaginal follicular aspiration in cows. This new instrument consists of out- & inner-layer stainless pipes and a grip with a trigger(hand) switch. Some gauge types of disposable needles and tubes can be attached to this inner pipe. With this instrument, while grasping an ovary with one hand, the other hand can handle in apiration and vacuum on/off with the least assitant's help. With this instrument the mean recovery rate of bovine follicular oocytes was 45.2%. In recovered oocytes, usable oocytes(Grade I & II) were 30.4% and this rate meant 1.4 oocytes per ovary. For 30 days after initial aspiration with this instrument, some adverse effects such as adhesion, hemorrhage, hematoma and other mass formation in/with ovaries were also examined by rectal examination, ultrasonographic and endoscopic images. Adhesion was found in one ovary 1 week after aspiration, and hemorrhagic lesion was found 1-2 days and petechia were found 3-5 days after aspiration and there was no remarkable adverse effects. It was found that this instrument could be applicable and safe for ovum pick-up in cows.

  • PDF

Diagnostic Value of Ultrasound-Guided Fine Needle Aspiration Biopsy in Malignant Thyroid Nodules: Utility for Micronodules

  • Unal, Betul;Sezer, Cem
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제15권20호
    • /
    • pp.8613-8616
    • /
    • 2014
  • Background: The diagnostic approach to thyroid nodules involves ultrasound-guided fine needle aspiration biopsy (US-FNAB). We especially aimed to evaluate the contribution and the place of US-FNAB in preoperative evaluation of the malignant cases and draw attention to discordant cases diagnosed with papillary thyroid microcarcinoma (PTMC). Materials and Methods: A total of 276 cases were retrospectively reviewed who were subsequently diagnosed with a malignancy and who underwent US-FNAB. Results: Some 45 were found to have previously undergone the US-FNAB procedure. Of the patients in whom the surgical specimen was diagnosed with a malignancy, 21 (46.7%) were diagnosed as malignant or suspicious for malignancy, and 24 (53.3%) were concluded as benign or insufficient for diagnosis. Patients with the diagnosis of PTMC outnumbering the others was a striking finding (11 cases, 24%). Conclusions: We suggest performing repeat aspiration biopsy considering sampling errors in cases where inconsistency exists between clinical findings and cytological results in thyroid nodules smaller than 10 mm in diameter and with suspicious findings on ultrasonography.

Minimally Invasive Approach to Esophageal Perforation after Endoscopic Ultrasound-Guided Fine-Needle Aspiration: A Report of 2 Cases

  • Geraedts, Anna C.M.;Broos, Pieter P.H.L.;Gronenschild, Michiel H.M.;Custers, Frank L.J.;Hulsewe, Karel W.E.;Vissers, Yvonne L.J.;de Loos, Erik R.
    • Journal of Chest Surgery
    • /
    • 제53권5호
    • /
    • pp.313-316
    • /
    • 2020
  • Esophageal perforation after endoscopic ultrasound-guided fine-needle aspiration for mediastinal staging is a rare but severe complication. We report 2 cases of patients with esophageal perforation who were treated using video-assisted thoracoscopic surgery in combination with esophageal stenting. Through these cases, the feasibility of minimally invasive thoracic surgery was evaluated.

개에서 발생한 간 농양의 진단 영상과 치료 증례 (Diagnostic imaging and treatment of hepatic abscess in a Dachshund)

  • 정주현;채웅주;장진화;오선경;윤정희;최민철
    • 대한수의학회지
    • /
    • 제48권1호
    • /
    • pp.119-124
    • /
    • 2008
  • A castrated male, 4-year old, Dachshund weighing 5.3 kg with an acute history of anorexia, vomiting, severe depression, and hypothermia for 1 day was referred. Severe leukopenia, mild increased hepatic enzymes, and mild imbalanced electrolyte were found on laboratory tests. There are no remarkable findings on abdominal radiographs. Ultrasonography showed multifocal heterogeneous and hypoechoic round regions in the liver. Ultrasound guided fine needle aspiration and drainage were performed and hepatic abscess was diagnosed. The patient was recovered normally without any complications through aggressive medical treatments from the result of culture and sensitivity test.