• Title/Summary/Keyword: ultrasound focusing

Search Result 73, Processing Time 0.02 seconds

New Circular Wave Generation Method for Synthetic Focusing in Ultrasonic Imaging Systems (초음파 영상 시스템에서 합성 집속을 위한 새로운 구면파 발생 방법)

  • Ahn, Young-Bok
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.798-802
    • /
    • 2007
  • The synthetic focusing in the ultrasonic imaging systems has been formed in the way that one element transmits a circular wave and receives an echo signal. The amplitude of the signal transmitted from one element is too small to propagate a long distance so that the SNR(Signal to Noise Ratio) is very low in an image obtained by the synthetic focusing. To solve this problem, a defocusing method which uses several elements has been proposed. In this method, the SNR is improved due to using several elements to transmit the circular wave. But if the number of transmitting elements increases, the phase distortion is severe in the defocusing method. In this paper, we propose a new method that can generate a circular wave using a lot of elements without phase distortion. At first, we generate limited plane waves with different propagation angles and then superpose them to make a circular wave. We show that the circular wave can be used to improve SNR in the real-time 3D ultrasonic imaging as well as the synthetic focusing through computer simulation and experiments.

Design of Ultrasound Dynamic Focusing Systems (초음파 다이나믹 집속 시스템의 설계)

  • 김진하;김청월
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.21 no.4
    • /
    • pp.65-71
    • /
    • 1984
  • The design formular of optical focusing systems cannot be applied to ultrasonic B scanners, which use broadband pulses instead of continuous wave. In this paper, a calculation method is studied for analyzing the propagation of ultrasonic broadband pulse excited by ultrasonic array transducers. Using the results, seveial design parameters such as the number of transducer elements, delay time, and the focal point are determined to obtain high resolution in the ultrasonic dynamic focusing system. A dynamic focusing system with low-noise switching characteristics; which attains lateral resolution of 2-3mm all along the axial direction up to 18 cm with a 3.5 MHz linear array transducer, was implemented.

  • PDF

A Study of Sidelobe Reduction Based on FFT in Ultrasound Images (FFT를 기반으로 한 초음파 영상의 Sidelobe 영향 감소에 관한 연구)

  • 정목근
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.40-47
    • /
    • 1999
  • Focusing is widely used to increase the resolution in ultrasound transmit field. It increases signal levels returning from the mainlobe direction and decreases those due to sidelobe directions. However, when the sidelobes cannot be completely canceled, the resulting image resolution is greatly deteriorated. This paper proposes a method of improving the resolution by scaling the received signal according to the difference between the mainlobe and sidelobe levels computed in the frequency domain by the use of Fourier transform. The proposed method is verified by computer simulation and experiments, and is shown to be highly effective in narrowing the mainlobe width and decreasing the sidelobe levels.

  • PDF

Development of Ultrasound B-scanner(I)-System and Analog Part- (초음파 B스캔너의 개발(I) -시스템 및 아나로그부분-)

  • 김진하;신동희
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.77-84
    • /
    • 1984
  • A prototype of a linear real-time ultrasound B-scanner has been developed which has an axial resolution of 1-2mm and lateral resolution of 2-3mm. In the actual hardware and software implementations of the B-scanner, the following features were emphasized; (1) a dynamic focusing to improve resolution; (2) signal processing to obtain low noise image; (3) various functions for the user's convenience' (4) simplification of the system by an extensive use of recently developed LSI's; (5) development of a prototype at the level of a commercial product. This paper reports the experimental results of the overall system and the design approach of the analog part. The work on the digital part of the B-scanner is reported in part (II) seperately.

  • PDF

A Tangible Floating Display System for Interaction

  • Kim, Youngmin;Kang, Hoonjong;Ahn, Yangkeun;Choi, Kwang-Soon;Park, Byoungha;Hong, Sunghee;Jung, Kwang-Mo
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.32-36
    • /
    • 2014
  • A tangible floating display that can provide different perspective views without special glasses being introduced. The proposed system can display perspective floating images in the space in front of the system with the help of concave mirrors. In order to avoid wearing special equipment to interact and deliver the sense of touch, the proposed system adopted an ultrasound focusing technology. For providing an immersive experience to the viewers, the proposed system consists of a tangible floating display system and a multiple-view imaging system for generating three lenticular displays in front of the users.

Convergence Formulation studies of Diagnostic Ultrasound Transmission Media:focusing on the manufacturing costs and rheology (초음파전파매개물의 융복합 제형 연구 :제조비용, 윤활성에 대하여)

  • Lee, Hye-Nam;Park, Mi-Soon;Park, Yeon-Hwa
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.369-374
    • /
    • 2015
  • In this study, by combining a unique purpose and additional aspects of ultrasonic transmission media, a development potential on a new ultrasonic transmission media was sought. The rheological characteristics and the manufacturing cost for each manufactured formulation were compared and analysed with ready-made. An ultrasonic transmission media is to have different functional characteristics according to the following formulation, it was the best in rheological value, low viscosity emulsion with the oil gel. Polymer hydro gel is can be manufactured at low cost compared to other formulations. Emulsion which shows a sharp viscosity difference according to the components of oil and water had a big difference in manufacturing cost. This study can be utilized as the fundamental data on the ultrasound transmission media equipped with expertise in various areas of ultrasound.

Neuroimaging of Germinal Matrix and Intraventricular Hemorrhage in Premature Infants

  • Sun Kyoung You
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.3
    • /
    • pp.239-246
    • /
    • 2023
  • Germinal matrix and intraventricular hemorrhage (GM-IVH) are the major causes of intracranial hemorrhage in premature infants. Cranial ultrasound (cUS) is the imaging modality of choice for diagnosing and classifying GM-IVH. Magnetic resonance imaging (MRI), usually performed at term-equivalent age, is more sensitive than cUS in identifying hemorrhage in the brain. Post-hemorrhagic ventricular dilatation is a significant complication of GM-IVH and correlates with adverse neurodevelopmental outcomes. In this review, we discuss the various imaging findings of GM-IVH in premature infants, focusing on the role of cUS and MRI.

An Experimental Study of the Synthetic Sinc Wave in Ultrasonic Imaging (초음파 의료 영상에서 합성 Sinc 음장 집속방법의 실험적 고찰)

  • 이광주;정목근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.243-251
    • /
    • 2002
  • Synthetic zinc wave employs Pulsed plane wave as transmit beam with linear time delay curve. The received echoes in different transmit directions at different transmit times are superposed at imaging Points with Proper time delay compensation using synthetic focusing scheme. This scheme. which uses full aperture in transmit, obtains a high SNR image, and also features high lateral resolution by using two way dynamic focusing at all imaging depths. In this Paper, we consider the Problems in realization of synthetic zinc wave. Also. we have applied the scheme to obtain phantom and in-vivo images using a linear array of 5 MHz. In phantom test. experimental images show high resolution over a more extended imaging depth than conventional fixed Point transmit and receive dynamic focusing schemes In-vivo images show that the resolution could not overcome conventional focusing systems because of motion blurring and(or) aberration of tissue. but the frame rate tan be increased by a factor of more than 5 compared to conventional focusing schemes. with competitive resolution at all imaging depths .

Image Enhancement for Sub-Harmonic Phased Array by Removing Surface Wave Interference with Spatial Frequency Filter

  • Park, Choon-Su;Kim, Jun-Woo;Cho, Seung Hyun;Seo, Dae-Cheol
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.3
    • /
    • pp.211-219
    • /
    • 2014
  • Closed cracks are difficult to detect using conventional ultrasonic testing because most incident ultrasound passes completely through these cracks. Nonlinear ultrasound inspection using sub-harmonic frequencies a promising method for detecting closed cracks. To implement this method, a sub-harmonic phased array (PA) is proposed to visualize the length of closed cracks in solids. A sub-harmonic PA generally consists of a single transmitter and an array receiver, which detects sub-harmonic waves generated from closed cracks. The PA images are obtained using the total focusing method (TFM), which (with a transmitter and receiving array) employs a full matrix in the observation region to achieve fine image resolution. In particular, the receiving signals are measured using a laser Doppler vibrometer (LDV) to collect PA images for both fundamental and sub-harmonic frequencies. Oblique incidence, which is used to boost sub-harmonic generation, inevitably produces various surface waves that contaminate the signals measured in the receiving transducer. Surface wave interference often degrades PA images severely, and it becomes difficult to read the closed crack's position from the images. Various methods to prevent or eliminate this interference are possible. In particular, enhancing images with signal processing could be a highly cost-effective method. Because periodic patterns distributed in a PA image are the most frequent interference induced by surface waves, spatial frequency filtering is applicable for removing these waves. Experiments clearly demonstrate that the spatial frequency filter improves PA images.

An Efficient Motion Estimation and Compensation Method for Ultrasound Synthetic Aperture Imaging (초음파 합성구경 영상을 위한 효율적인 움직임 추정 및 보상 기법)

  • 김강식;황재섭;정종섭;송태경
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.87-99
    • /
    • 2002
  • This paper describes a method for overcoming the motion artifacts inherent in synthetic aperture(SA) imaging. based on the investigation results as to the influence of a target motion on synthetic aperture techniques. This method uses a region-based motion compensation approach in which only the axial motion is estimated and compensated for a given region of interest(ROI) under the assumption that the whole ROI moves uniformly The estimated axial motion is calculated with a crosscorrelation(CC) method at the Point where the focused signal has the maximum energy within the ROI. We also presents a method for estimating the axial motion using the autocorrelation(AC) method that is widely used to estimate average Doppler frequency Both computer simulations and in vivo experiments show that the proposed methods can improve greatly the spatial resolution and SNR of ultrasound imaging by implementing the SA techniques for two-way dynamic focusing without motion artifacts. In addition the AC-barred motion compensation method provides almost the same results as the CC-based one, but with a dramatically reduced computational complexity.