• Title/Summary/Keyword: ultrasound echo

Search Result 85, Processing Time 0.026 seconds

Nondestructive Evaluation Technique of Painted Sandwich Control Surfaces of CN-235 using Full-field Pulse-echo Ultrasonic Propagation Imaging System (전영역 펄스-에코 초음파전파영상화 시스템의 CN-235의 도색된 샌드위치 조종면 In-situ 비파괴평가 기술)

  • Hong, Seung-Chan;Lee, Jung-Ryul;Park, Jongwoon
    • Composites Research
    • /
    • v.29 no.5
    • /
    • pp.288-292
    • /
    • 2016
  • In this paper, a novel ultrasonic propagation imaging system, called a full-field pulse-echo ultrasonic propagation imaging (FF PE UPI) system is introduced. The system nondestructively inspected targets with two-axis translation stage. The coincident laser beams for ultrasonic sensing and generation are scanned and pulse-echo mode laser ultrasounds are captured. This procedure makes it possible to generate full-field ultrasound in through-the-thickness direction as large as the scan area. Structural inspection results in the form of full-field ultrasonic wave propagation videos are introduced, which are painted sandwich control surfaces. In addition, the inspection results of FF PE UPI system are compared with conventional ultrasonic testing methods such as waterjet and portable C-scan.

Ultrasonic Measurement of Tissue Motion for the Diagnosis of Disease

  • Beach Kirk W.
    • International Journal of Vascular Biomedical Engineering
    • /
    • v.1 no.1
    • /
    • pp.3-12
    • /
    • 2003
  • Ultrasonic pulsed Doppler velocimetry has become a standard international method of classifying carotid disease. Because the measured angle adjusted velocity increases as the Doppler angle increases, examinations should be performed at a convenient standard Doppler examination angle. An angle of 60 degrees is achievable throughout most examinations. Multiple Doppler viewing angles allow the acquisition of velocity vectors during the cardiac cycle, revealing the complex velocity patterns. Ultrasonic velocimetry (whether Doppler or time domain) is based on changes in the phase of the ultrasound echo. Other examinations can be done based on the echo phase. Slow motions of organs such as the brain can be used to monitor changes in edema. Measurements of tissue strain due to the pulsatile filling of the arterioles. This plethysmographic imaging method can display differences in tissue perfusion because of different tissue types and changes in autonomic activity.

  • PDF

An analysis of Ultrasound signals using wavelet transform (II) (Wavelets 변환을 이용한 초음파 신호의 분석 (II))

  • Hong, S.W.;Kim, D.J.;Choi, H.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.11
    • /
    • pp.583-586
    • /
    • 1997
  • In this study, we proposed an application of wavelet transform or analysis of ultrasound echo signals to improve troubles of convenianced methods such as SDM, SSM. We examined method using wavelet transform to prove again our proposal which we have proposed prior time. At first, we made phantoms by adding 0.01, 0.015, 0.02, 0.025, 0.03, 0.035, 0.04, 0.045, 0.05($g/cm^3$) on constant quantity of distilled water and agar, and collected echo signals. We used SDM(spectral difference method) and WTM(wavelet transform method) as signal processing method. To compare with WTM, SDM was used. In WTM, we selected detail signals of level 3 of Daubechies 16, and got derivative, calculated area of it. Next, we calculated slopes. In SDM, it was 0.0308 and in WTM, it was 0.5248. As a result, we knew that we could know that the values using WTM showed more detailed than those using SDM. So we could concluded wavelet transform is very useful and powerful in ultrasound tissue characterization.

  • PDF

Object imaging in the water by neural network and multi-element ultrasound transducer (신경회로망과 다소자 초음파 트랜스듀스에 의한 수중물체의 화상화)

  • 김응규
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.1
    • /
    • pp.80-87
    • /
    • 1998
  • In this study, a multi-element ultrasound transducer has been developed aiming at basic experiment of three-dimension endovascular ultrasound endscopy for clinical diagnos, and experimental results of two-dimensional object imaging in the water are presented by the ultrasound tranducer and neural network. Each ultrasound echo received by thirty-six angular transducer elements is inputed to the eural network, and then backpropagation is used as a learning algorithm. A three-layer artificial neural network is used for learning and imaging of targetw placed in front of the transducer. The object shape of imaging is restricted to rectangular shapes by considering experimental restraint conditions. As a result, rough visualization can be realized even for objects with unlearned shapes through the training by primitive patterns of a various sized rectangular targets.

  • PDF

Forward-Looking Ultrasound Imaging Transducer : II. Fabrication and Experimental Results

  • Lee, Chankil
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.2E
    • /
    • pp.76-84
    • /
    • 1996
  • The experimental testing results of the large-scale version of a forward-looking ultrasound imaging catheter(FLUIC) are presented, along with the fabrication techniques used, experimental methods, and comparisons of the measured and simulated results. The transducer model is verified by measuring the electrical impedance of the transducer. The pulse width, beamwidth, and the dynamic range for both transmit and pulse-echo response of the fabricated FLUIC are also analyzed. The experimental results conformed its forward-looking imaging capability and the sources of discrepancies between the simulated and experimental beam profiles are addressed.

  • PDF

Fabrication of Microcantilever Ultrasound Sensor and Its Application to the Scanning Laser Source Technique

  • Sohn, Young-Hoon;Krishnaswamy, Sridhar
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.6
    • /
    • pp.459-466
    • /
    • 2005
  • The scanning laser source (SLS) technique has been proposed recently as an effective way to investigate small surface-breaking defects, By monitoring the amplitude and frequency changes of the ultrasound generated as the SLS scans over a defect, the SLS technique has provided enhanced signal-to-noise performance compared to the traditional pitch-catch or pulse-echo ultrasonic methods, An extension of the SLS approach to map defects in microdevices is proposed by bringing both the generator and the receiver to the near-field scattering region of the defects, To facilitate near-field ultrasound measurement, silicon microcantilever probes are fabricated using microfabrication technique and their acoustical characteristics are investigated, Then, both the laser-generated ultrasonic source and the microcantilever probe are used to monitor near-field scattering by a surface-breaking defect.

Ultrasound Echolocation Inspired by a Prey Detection Strategy of Big Brown Bats (박쥐의 먹이 탐지 전략을 모방한 초음파 센서의 물체 위치 추정)

  • Park, Sang-Wook;Kim, Dae-Eun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.18 no.3
    • /
    • pp.161-167
    • /
    • 2012
  • It is known that big brown bats can distinguish echo of a prey at various angles. In this paper, we suggest a new object localization strategy using ultrasonic echolocation. We calculate the relative energy ratio between a high frequency component of ultrasound signal and a low frequency component of ultrasound signal for a target object. We found the measure depends on bearing angle of the object in space. We also tested energy ratio of echoed FM ultrasound signals depending on frequency, based on cross-correlation. It can determine the relative angular position of objects even though the reflected signals are congested form each object.

Development of a Mobile Ultrasound Scanner for Point-of-care Applications (현장 진단 응용을 위한 모바일 초음파 스캐너 개발)

  • Cho, Jeong;Sohn, Hak-Yeol;Kim, Gi-Duck;Song, J.H.;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.1
    • /
    • pp.66-78
    • /
    • 2009
  • A mobile ultrasound scanner developed for use in point-of-care applications is introduced, which can not only provide ultrasound images but can also measure various bio-signals. The mobile ultrasound scanner is also designed to meet the demanding requirements for point-of-care diagnosis, such as battery-powered operation, portability in terms of size and weigh, and real-time wireless communications capability for remote diagnosis. To meet these requirements, an efficient beamforming method for high resolution imaging with a small number of active elements, a hardware efficient beamformer architecture, and echo processing algorithms with greatly reduced computational complexity have been developed. Experimental results show that the prototype mobile ultrasound scanner is fully functional and satisfies most of the design requirements.

Ultrasonographic evaluation of rotator cuff leison

  • Sugimoto Katsumasa;Matsui Nobuo
    • The Academic Congress of Korean Shoulder and Elbow Society
    • /
    • 1995.03a
    • /
    • pp.46-46
    • /
    • 1995
  • We investigated the reliablity of the ultrasonography for diagnosis of rotatar cuff taers. We prepared histological sections of forty shoulder joints In match the ultrasound planes, and conducted a comparative study of tke two sets of images. hi cases of rotator cuff tear, hyperechogenic and cartilaginfication of the tear site were detected as hyperechogenic foci. On the countrary, the regions in which tendon fibers were decreased or absent showed sonolucent areas. We caluculated the echo level of rotator cuff objectively. The area of abnormal echo level and the other regions located in the same depth of the rotator cuff were defined by ultrasonic equipment. The mein difference in these two echo levels was calculated. The mean difference in patients with rotator cuff tears was larger than that in normal cases. These results indicate that ultrasonography is a useful procedure in many patients with rotator cuff lesions.

  • PDF

Phantom Experiments for Breast Cancer Detection by Ultrasound Transmission Period

  • Sakasegawa, Aya;Hoshino, Hirokazu;Tsuji, Kiichi;Hayakawa, Yoshinori
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.481-484
    • /
    • 2002
  • In every cancer early detection and early treatment is the best way to decrease mortality of patients. Moreover early detection of breast cancer increases the possibility of breast conservation treatment. Although mammography is the most powerful modality for early detection, it is hazardous to be used for young women due to X-ray exposure. Another modality of image diagnosis is ultrasound echo technique. But it is not so powerful to detect breast cancer compared to mammography. Palpation is another modality, but is largely dependent on the skill and experience of medical doctors. A new technique is tested its validity in phantom experiments with good results.

  • PDF