• Title/Summary/Keyword: ultrasonic pulse wave

Search Result 128, Processing Time 0.03 seconds

Bonding Strength Analysis and Ultrasonic Testing of Structural Adhesive Joints (구조접착 이음에서의 접합강도해석과 초음파실험)

  • 장철섭;오승규;김종현;황영택;이원
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.860-864
    • /
    • 2004
  • This article discusses the use of pulse-echo ultrasonic testing for the stress analysis of adhesive bonds between metal sheets. The method is based on the measurement of the reflection wave at the metal/adhesive interface. After describing briefly the physical aspects of the phenomenon, an index is defined to detect defective zone of the joint(both for the lack of adhesive and for insufficient adhesion); the influence of the experimental variables(variables stress...) on the measurement is discussed. By means of a control experiment it is shown that Stress Variation in Adhesive Joints are separate to be distingguished. In this paper, Quantitative Nondestructive Evaluation in Adhesive Joints are together with Ultrasonic Testing and Finite Element Method.

  • PDF

AN ULTRASONIC METHOD FOR VIBRATION MEASUREMENT OF THE SUSPENSION IN HARD DISK DRIVES (하드디스크 서스펜션의 초음파 진동측정 기술)

  • Ha, Wan;Kim, Noh-Yu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.720-725
    • /
    • 2000
  • A new ultrasonic pulse-echo technique was developed and described for vibration measurement of the suspension assembly in hard disk drives. The method is based upon the difference in magnitude of two consecutive reflection waves from a moving object(suspension), while the traditional ultrasonic vibrometer uses the phase shift of the reference wave and the reflection wave. A cone-shape delay line is designed to access the small structure. A simple mathematical model is presented and analyzed with experimental results to show the feasibility of the method. The advantages of this ultrasonic vibration measurement method are relatively high resolution, low cost, and ease of implementation comparing with the Laser Doppler vibrometer.

  • PDF

Fundamental and Harmonic Wave Characteristics of Concrete Subjected to Temperature by Strength (고온이력을 받은 콘크리트의 강도별 기본파와 고조파 특성)

  • Suh, Dong-Kyun;Kim, Gyu-Yong;Son, Min-Jae;Sasui, Sasui;Eu, Ha-Min;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.207-208
    • /
    • 2021
  • The non-destructive method using ultrasonic waves has been applied in many studies due to its low damage to the structure and its simple evaluation method and high precision. On the other hand, if the concrete is subjected to a high-temperature, the mechanical properties may be deteriorated due to the micro-crack network and the damage may be severe depending on the strength of the concrete. Therefore, this study attempts to evaluate the fundamental wave behavior of different strength ranges using the ultrasonic non-destructive method for concrete that has been subjected to high-temperature. As a result, the relative power of the fundamental wave was decreased as temperature increase. And it was confirmed that the 2nd and 3rd harmonics were generated at 110 MPa. However, to check the 2nd, 3rd harmonics 110 MPa or less, there is a need for further research considering the ultrasonic output, the output of the sender and receiver, and the appropriate frequency accordingly.

  • PDF

Crack Size Determination Through Neural Network Using Back Scattered Ultrasonic Signal (저면산란 초음파 신호 및 신경회로망을 이용한 균열크기 결정)

  • Lee, Jun-Hyeon;Choe, Sang-U
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.52-61
    • /
    • 2000
  • The role of quantitative nondestructive evaluation of defects is becoming more important to assure the reliability and the safety of structure, which can eventually be used for residual life evaluation of structure on the basis of fracture mechanics approach. Although ultrasonic technique is one of the most widely used techniques for application of practical field test among the various nondestructive evaluation technique, there are still some problems to be solved in effective extraction and classification of ultrasonic signal from their noisy ultrasonic waveforms. Therefore, crack size determination through a neural network based on the back-propagation algorithm using back-scattered ultrasonic signals is established in this study. For this purpose, aluminum plate containing vertical or inclined surface breaking crack with different crack length was used to receive the back-scattered ultrasonic signals by pulse echo method. Some features extracted from these signals and sizes of cracks were used to train neural network and the neural network's output of the crack size are compared with the true answer.

Analysis of an Error Accompanying Measured Surface Crack Depth of Concrete Using Ultrasonic Pulse Velocity Method (초음파법에 의한 콘크리트 표면 균열 깊이의 측정오차 분석에 관한 연구)

  • 박석균;최욱
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.175-180
    • /
    • 2003
  • Ultrasonic pulse velocity method is applied many times for measuring surface crack depth of concrete in case of diagnosis of concrete structures. By the way, this method has an error accompanying measured surface crack depth of concrete because there are many uncertainty factors. So, it is necessary to study for an error of this method affected by these uncertainty factors. Two error factors(uncertainty factors) are tested and analyzed in this study. One is for an error according to measuring the propagation time of ultrasonic wave and the arrangement distance of transducers. Another is for an error according to positioning the transducer as a distance to surface crack from the transducer.

  • PDF

A Study on the Improvement in Performance of Ultrasonic Pulsed Doppler Velocimeter (초음파 펄스 도플러 속도계의 성능 개선에 관한 연구)

  • 이은방;이상집
    • Journal of the Korean Institute of Navigation
    • /
    • v.20 no.3
    • /
    • pp.85-95
    • /
    • 1996
  • In the velocimeter, the ultrasonic pulse signal is used for measuring the profile velocity of moving targets distributed in space because of the merits of its high distance resolution and harmless affect to the human body. The velocity reading in conventional ultrasonic pulsed velocimeter depends on the wave pattern reflecting the spatial distribution of scatters and includes observational error due to the signal processing of analyzing pulse signal. In this paper, we evaluate an influence of the received waveform of pulsed signal on the velocity information by setting a model. Subsequently, in order to improve the distance resolution and to obtain precise velocity information without the influence of the spatial distribution of scatterers, we propose a new method for the analysis of Doppler pulsed signal, in which the pulsed signal is transformed into a phase function with local data. Finally, it is confirmed that the performance of the velocimeter is more improved in the proposed method than in the conventional one.

  • PDF

The Study for Correlation Characteristics on Radial Artery and Floating/sinking Pulse with BMI (BMI에 따른 요골동맥의 혈관특성과 부/침맥과의 상관관계 연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.121-126
    • /
    • 2008
  • Pulse diagnosis refers to the process of diagnosing a patient by feeling an artery on the wrist based on the shape that the pulse take s while the hold-down pressure increase. The styloid process artery on the wrist is usually felt, and the pulse is taken on Chon, Gwan and Cheok using three fingers. This study is to examine the structural difference in the location of pulse diagnosis by measuring and analyzing blood diameter, blood depth, and blood flow velocity of the location of pulse diagnosis by using ultrasonic wave (VOLUSION730 PRO, GE Medical, U.S.A). This study also attempted to grasp whether the characteristics of blood vessels differ depending on Body Mass Index (BMI) and analyzed their correlation with Oriental medical pulse diagnosis. The male subjects without cardiovascular diseases were divided into the normal BMI group, the underweight group and the overweight group and 10 people of each group were measured, Blood depth, blood diameter and blood flow velocity at the location of pulse diagnosis (Chon, Gwan, Cheok) of the wrists of left and right hands were measured and the pulse wave was measured by using pulse diagnosis instrument (3-D Mac, DaeyoMedi, Korea).The results of this study showed that the characteristics of blood vessels differ depending on the degrees of obesity, and the characteristics of floating pulse and sinking pulse of Oriental medical pulses were related to the degrees of obesity. This shows that the characteristics of the blood vessels of subjects and BMI information are the major indicators for diagnosis and are the matters that must always be considered when developing the algorithm of pulse diagnosis.

  • PDF

Implementation of High Accurate Level Sensor System using Pulse Wave Type Magnetostriction Sensor (펄스파 자왜 센서를 이용한 고정밀 액위 센서 시스템의 실현에 관한 연구)

  • Choi, Woo-Jin;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.395-400
    • /
    • 2013
  • In this paper, we introduce the implementation of high accurate level sensor system using the pulse wave type magnetostriction sensor. When a current pulse flows along the waveguide, the magnetic field also propagates towards the end of waveguide. When this magnetic field just passes the position of the magnet for level detection, the resultant magnetic field by these two magnetic fields makes a torsional reflected signal. This is used to calculate the time difference between a interrogation pulse wave and this torsional reflected signal. The key elements and characteristics were investigated to implement level sensor system based on this principle. We introduce a method to calculate the speed of ultrasonic reflected signal and how to make a model of sensing coil. In particular, we experiment with the characteristics of the torsional reflected signal according to the changes of the interrogation voltage and displacement. To make high accurate level sensor system, two methods were compared. One is to use the comparator and time counter, the other is STFT(Short Time FFT) which is capable of the time-frequency analysis.

Nondestructive Evaluation of Creep Damage Materials by using Ultrasonic Spectrum Analysis (초음파 Spectrum 해석에 의한 Creep 손상재의 비파괴평가)

  • Kim, C.I.;Yi, W.;Lim, Y.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.2
    • /
    • pp.42-47
    • /
    • 1991
  • Nondestructive evaluation study was made on creep damage materials by ultrasonic spectrum analysis. The evaluation methods was developed in order to predict the change of ultrasonic attenuation with increasing creep damage. A new algorithm for the improvement of measuring accuracy of ultrasonic attenuation using a spectrum analysis has been developed. Normally, the ultrasonic attenuation is evaluated from 1st and 2nd peak values of the pulse-echo ultrasonic wave. The algorithm developed is incorporated in a measuring system which consists of a personal computer with ultrasonic apparatus and a digital storage oscilloscope. By the spectrum analysis method, it become popssible to describe approximately the attenuation change with increassing creep damage in Cr-Mo-V forging.

  • PDF

Development of an Ultrasonic Gas Flow Meter Using Transit Time Difference (전달 시간차 방식 초음파 가스 유량계)

  • 박상국;황원호
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.9 no.9
    • /
    • pp.707-713
    • /
    • 2003
  • We investigate the ultrasonic gas flow meter for the measurement of gas volume quantity, which passing through pipe, using the transit time difference method. We have designed a receiving system of an ultrasonic signal and hardware system of a flow meter Also, we have designed an experimental system for the characteristic test and calibration of a gas flow meter system. We have developed an ultrasonic gas flow meter, which has a measurement uncertainty within $\pm$ 1.7 %. For the test, we have compared our system with a difference pressure type flow meter for a few months in the real field. Through the test, we have confirmed that our system have a good reliability and durability. Also, we have confirmed that our system follows very well the variation of gas volume quantity, which was measured by a difference pressure type flow meter.