• Title/Summary/Keyword: ultrasonic parameters

Search Result 324, Processing Time 0.029 seconds

Removal Characteristics of Lead-contaminated Soil at Military Shooting Range by Using Soil Washing Process (토양세척공정을 이용한 군사격장 납 오염토양의 제거특성)

  • Ahn, Sung-Kyun;Kim, Chul;Lee, Joung-Man;Lee, Gang-Choon;Shon, Zang-Ho;Jung, Byung-Gil;Yoon, Tae-Kyung
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.390-397
    • /
    • 2012
  • Removal characteristics of lead-contaminated soil at the military shooting range located in the Changwon city were studied experimentally using soil washing process. As a washing solution, hydrogen chloride (HCl) concentrations of 0.001, 0.01, 0.1 and 0.2 N were used, and soil : solution ratios were 1 : 2, 1 : 3, 1 : 4, and 1 : 5. Particle diameter of contaminated soil of 4-0.075 mm, and washing period of 5, 10, 15, 20, 30, 60, and 120 min were used as operating parameters. The optimum concentration of HCl solution was 0.1 N (56.3% of Pb removal efficiency) with 15 minutes operation period in views of economics, and the optimum soil : solution ratio was determined as 1 g : 3 mL for 69.7% of Pb removal efficiency with 0.1 N HCl and 15 minutes washing period. As washing period increased, removal efficiency was increased until 20 min of the removal efficiency of 75.3%, and then almost stable. Pb removal efficiency in soil particle diameters of 0.075 mm or more was ranged from 77.0% to 82.0%, but it was decreased to 52.8% in diameter of less than 0.075 mm. Therefore, the optimum cut-off size of the soil particle diameter was found less than 0.075 mm. Combined HCl solution and ultrasonic washing method showed better removal efficiency compared to only water or HCl washing method for particle sizes above 0.075 mm.

Implementation of a Person Tracking Based Multi-channel Audio Panning System for Multi-view Broadcasting Services (다시점 방송 서비스를 위한 사용자 위치추적 기반 다채널 오디오 패닝 시스템 구현)

  • Kim, Yong-Guk;Yang, Jong-Yeol;Lee, Young-Han;Kim, Hong-Kook
    • 한국HCI학회:학술대회논문집
    • /
    • 2009.02a
    • /
    • pp.150-157
    • /
    • 2009
  • In this paper, we propose a person tracking based multi-channel audio panning system for multi-view broadcasting services. Multi-view broadcasting is to render the video sequences that are captured from a set of cameras based on different viewpoints, and multi-channel audio panning techniques are necessary for audio rendering in these services. In order to apply such a realistic audio technique to this multi-view broadcasting service, person tracking techniques which are to estimate the position of users are also necessary. For these reasons, proposed methods are composed of two parts. The first part is a person tracking method by using ultrasonic satellites and receiver. We could obtain user's coordinates of high resolution and short duration about 10 mm and 150 ms. The second part is MPEG Surround parameter-based multi-channel audio panning method. It is a method to obtain panned multi-channel audio by controlling the MPEG Surround spatial parameters. A MUSHRA test is conducted to objectively evaluate the perceptual quality and measure localization performance using a dummy head. From the experiments, it is shown that the proposed method provides better perceptual quality and localization performance than the conventional parameter-based audio panning method. In addition, we implement the prototype of person tracking based multi-view broadcasting system by integrating proposed methods with multi-view display system.

  • PDF

An Innovative Solution for the Power Quality Problems in Induction Motor by Using Silica and Alumina Nano Fillers Mixed Enamel for the Coatings of the Windings

  • Mohanadasse, K.;Sharmeela, C.;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1621-1625
    • /
    • 2015
  • Power quality has always been a concern of power engineers. Certainly an argument can be successfully made that most parts of power engineering have the ultimate objective to improve power quality. AC motors were widely used in industrial and domestic applications. Generally, AC motors were of two types: Induction and Synchronous motors. In motor many parameters like different load cycling, switching, working in hot weather and unbalances creates harmonics which creates major reasons for temperature rise of the motors. Due to high peak value of voltage, harmonics can weaken insulation in cables, windings and capacitors and different electronic components. Higher value of harmonics increase the motor current and decrease the power factor which will reduce the life time of the motor and increase the overall rating of all electrical equipments. Harmonics reduction of all the motors in India will save more power. Coating of windings of the motor with nano fillers will reduce the amount of harmonics in the motor. Based on the previous project works, actions were taken to use the enamel filled with various nano fillers for the coating of the windings of the different AC motors. Ball mill method was used to convert the micro particles of Al2O3, SiO2, TiO2, ZrO2 and ZnO into nano particles. SEM, TEM and XRD were used to augment the particle size of the powder. The synthesized nano powders were mixed with the enamel by using ultrasonic vibrator. Then the enamel mixed with the nano fillers was coated to the windings of the several AC motors. Harmonics were measured in terms of various indices like THD, VHD, CHD and DIN by using Harmonic analyzer. There are many other measures and indices to describe power quality, but none is applicable in all cases and in many instances, these indices may hide more than they show. Sometimes power quality indices were used as a basis of comparison and standardization. The efficiency of the motors was increased by 5 – 10 %. The thermal withstanding capacity of the motor was increased by 5º to 15º C. The harmonics of the motors were reduced by 10 – 50%.

Magnitudes of the Harmonic Components Emitted from Utrasonic Contrast Agents in Response to a Diagnostic Utrasound: Theoretical Consideration (진단용 초음파에 의해 가진된 초음파 조영제에서 방사하는 하모닉 성분의 크기: 이론적 고찰)

  • Kang Gwan Suk;Yu Ji Chul;Paeng Dong Guk;Rhim Sung Min;Choi Min Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.78-86
    • /
    • 2005
  • This study considers the magnitude of the harmonic components radiated from the ultrasonic contrast agents (UCA) activated by a typical diagnostic ultrasound. The nonlinear dynamic response of UCA to a 2 MHz diagnostic ultrasound pulse was predicted using Gilmore Model. The elastic property of the shell membrane of the UCA was ignored in the numerical model. Simulation was carried out for the UCA varying from 1 - 9 $\mu$m in its initial radius and the driving diagnostic ultrasound whose mechanical index (MI) ranges from 0.125 to 8. The powers of the sub. ultra and second harmonics of the acoustic signal from the UCA activated were compared with that of the fundamental component. The results show that. if the UCA is bigger than its resonant size (2 $\mu$m in radius for the present case) the sub harmonic power was much bigger than the fundamental. In particular, the 2nd harmonic component currently used as an imaging parameter for the harmonic imaging, was predicted to be lower in power than both the sub and the ultra harmonic component. This study indicates that, for obtaining harmonic imaging with UCA, the sub or ultra harmonics could be taken as imaging parameters better than the 2nd harmonic component.

Influence of Operating Parameters on Nitrite Accumulation in a Biofilm Reactor and Supplement of External Carbon Source for Denitrification by Sewage Sludge Solubilization (생물막 반응조에서 아질산염 축적에 미치는 운전인자 영향과 하수슬러지 가용화에 의한 탈질반응의 외부탄소원 공급에 관한 연구)

  • Ahn, Hye Min;Lee, Dae Sung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.1
    • /
    • pp.57-63
    • /
    • 2013
  • A combined process consisted of a biofilm reactor and a continuously stirred-tank reactor (CSTR) was investigated for highly loaded ammonium wastewater treatment via nitrite accumulation. To enhance ammonium oxidizing bacteria over nitrite oxidizing bacteria on the surface of carriers, the biofilm reactor was operated at temperature of $35^{\circ}C$ for more than three months but the influent ammonium (500 mg-N/L) was partially oxidized to nitrite (240 mg-N/L). As pH was increased from 7.5 to 8.0, nitrite accumulation was fully achieved due to the inhibition of nitrite oxidizing bacteria under high free ammonia concentration. The biofilm reactor performance was severely deteriorated at the hydraulic retention time of 12 hr, at which incomplete nitrification of ammonia was observed. Various solubilization methods were applied to sewage sludge for enhancing its biodegradability and the combined method, alkaline followed by ultrasonic, gave the highest solubilization efficiency (58%); the solubilized solution was used as the external carbon source for denitrification reaction in CSTR. FISH analysis showed that the dominant microorganisms on the carriers were ammonium oxidizing bacteria such as Nitrosomonas spp. and Nitrospirar spp. but low amounts of nitrite oxidizing bacteria as Nitrobacter spp. was also detected.

Quantitative assessment of Endorectal Ultrasonography by using GLCM Algorithm (GLCM알고리즘을 이용한 경직장 초음파 영상의 정량적 평가)

  • Nho, Da-Jung;Kang, Min-Ji;Kim, Yoo-Kyeong;Seo, Ah-Reum;Lee, In-Ho;Jeong, Hee-Seong;Jo, Jin-Yeong;Ko, Seong-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.383-387
    • /
    • 2015
  • Bowel and rectal diseases are on the increase by irregular life and westernized eating habits of modern people, especially rectal cancer, which accounts for 50% of the entire colon cancer. For the initial rectal cancer, because there is no portion projecting on the surface, if not see inside the tissue with ultrasound, you make an errors that misdiagnosis as rectal abscess. However there is a need for more accurate diagnosis, because it is sometimes difficult to distinguish abscess from rectal cancer depending on staging, in spite of the ultrasonic diagnosis. Therefore, this study was performed quantitative analysis by using a computer algorithm for rectal cancer and abscess image. Each of 20 cases about normal, abscess and cancer by setting analysis region ($50{\times}50$ pixels) applies to GLCM algorithm and Autocorrelation, Max probability, Sum average, Sum variance in each image were analyzed by comparing the 4 single parameter. Consequently, The high lesion detection efficiency was presented 100% by the 3 parameter of Autocorrelation, Max probability, Sum variance and the parameter of Sum average presents 95% in cancer, more than 90% in abscess. Those parameters are valuable in distinction standard about normal, cancer and abscess in rectum. It is sufficient availability as a computer assisted diagnosis system depended on clinical using.

  • PDF

Evaluation of Dispersion Stability and Absorption Performance Enhancement of Binary Nanoemulsion Fluids (이성분 나노에멀전 유체의 분산안정성 및 흡수성능 촉진실험)

  • Lee, Jin-Ki;Kim, Young-Jin;Shin, Myung-Chul;Kim, Se-Won;Kang, Yong-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.9
    • /
    • pp.895-900
    • /
    • 2012
  • This paper aims to examine the effect of nanodroplets on pool-type absorption heat transfer enhancement and to find the relationship between the dispersion stability and the absorption performance. The concentrations of oil and surfactant are considered as the key parameters. $C_{12}E_4$ and Tween20 are used as the surfactants and N-decane oil is added to the $NH_3/H_2O$ solution to make the binary nanoemulsion fluids. Binary nanoemulsion fluids are dispersed by the ultrasonic vibrator and the stirrer under specific conditions. The dispersion stability of binary nanoemulsion fluids for each oil concentrations is evaluated from the droplet size and Tyndall effect analysis. The absorption performance of binary nanoemulsion fluids is compared with the result of dispersion stability. In addition, it is found that the binary nanoemulsion fluid is a strong candidate as a new working fluid for absorption applications.

Clinical features of the gingiva according to maxillary anterior teeth form in adult (성인 상악 전치 형태에 따른 치은의 임상적 소견)

  • An, Chi-Hyun;Heo, Soo-Rye;Cho, Ik-Hyun;Kim, Hyung-Seop
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.2
    • /
    • pp.359-369
    • /
    • 2005
  • It has been suggested that morphologic characteristics of the periodontium are partly related to the shape and form of the teeth. Furthermore, the severity of symptoms of periodontal disease have been proposed to differ among these various morphologic entities or "biotypes". The purpose of the present study was to examine the relationship between the form of the crowns in the maxillary anterior tooth segment and (1) a group of morphological characteristics and (2) the thickness of the gingiva. The thickness of gingiva was measured by ultrasonic device(SDM). 100 subjects devoid of symptoms of destructive periodontal disease were examined regarding, e.g., probing depth, gingival recession, width of keratinized gingiva, thickness of the keratinized gingiva. From maxillary study cast, the width(at the apical third-CW) and the length(CL) of the crowns of the 6 anterior teeth were determined. A CW/CL-ratio was calculated for each tooth and averaged for each tooth region. The individual mean CW/CL-ratio values for the central incisors were ranked. The 10 subjects ranked highest and the 10 ranked lowest were selected as having either a long-narrow(group N) or a short-wide(group W) form of the crown of the tooth. The data for each of the examined parameters were averaged for each tooth region in each subject and mean values for subjects in groups W and N were compared using the Student t-test. Stepwise multiple regression analysis, including data from the whole sample, was performed for each tooth region with the thickness of the free gingiva as the dependent variable. The results from the analyses demonstrated that individuals with a long-narrow form of the central incisors displayed, compared to individuals with a short-wide crown, form (l) a narrow zone of keratinized gingiva, (2) a pronounced "scalloped" contour of the gingival margin. There was no significant difference between groups N and W with respect to the thickness of the keratinized gingiva. The CW/CL-ratio data revealed that a certain form of the crowns in the central incisors was accompanied by a similar form in the lateral incisors and canine tooth region. The regression analyses demonstrated that the thickness of the keratinized gingiva in central, lateral incisors and canines was significantly related to the width of the keratinized gingiva.

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

Comparison of Pulsatile and Non-Pulsatile Extracorporeal Circulation on the Pattern of Coronary Artery Blood Flow (체외순환에서 박동 혈류와 비박동 혈류가 관상동맥 혈류양상에 미치는 영향에 대한 비교)

  • Son Ho Sung;Fang Yong Hu;Hwang Znuke;Min Byoung Ju;Cho Jong Ho;Park Sung Min;Lee Sung Ho;Kim Kwang Taik;Sun Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.101-109
    • /
    • 2005
  • Background: In sudden cardiac arrest, the effective maintenance of coronary artery blood flow is of paramount importance for myocardial preservation as well as cardiac recovery and patient survival. The purpose of this study was to directly compare the effects of pulsatile and non-pulsatile circulation to coronary artery flow and myocardial preservation in cardiac arrest condition. Material and Method: A cardiopulmonary bypass circuit was constructed in a ventricular fibrillation model using fourteen Yorkshire swine weighing $25\~35$ kg each. The animals were randomly assigned to group I (n=7, non-pulsatile centrifugal pump) or group II (n=7, pulsatile T-PLS pump). Extra-corporeal circulation was maintained for two hours at a pump flow of 2 L/min. The left anterior descending coronary artery flow was measured with an ultrasonic coronary artery flow measurement system at baseline (before bypass) and at every 20 minutes after bypass. Serologic parameters were collected simultaneously at baseline, 1 hour, and 2 hours after bypass in the coronary sinus venous blood. The Mann-Whitney U test of STATISTICA 6.0 was used to determine intergroup significances using a p value of < 0.05. Result: The resistance index of the coronary artery was lower in group II and the difference was significant at 40 min, 80 min, 100 min and 120 min (p < 0.05). The mean velocity of the coronary artery was higher in group II throughout the study, and the difference was significant from 20 min after starting the pump (p < 0.05). The coronary artery blood flow was higher in group II throughout the study, and the difference was significant from 40 min to 120 min (p < 0.05) except at 80 min. Serologic parameters showed no differences between the groups at 1 hour and 2 hours after bypass in the coronary sinus blood. Conclusion: In cardiac arrest condition, pulsatile extracorporeal circulation provides more blood flow, higher flow velocity and less resistance to coronary artery than non-pulsatile circulation.