• 제목/요약/키워드: ultrasonic instrument

검색결과 92건 처리시간 0.024초

Cutting efficiency of apical preparation using ultrasonic tips with microprojections: confocal laser scanning microscopy study

  • Kwak, Sang-Won;Moon, Young-Mi;Yoo, Yeon-Jee;Baek, Seung-Ho;Lee, WooCheol;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제39권4호
    • /
    • pp.276-281
    • /
    • 2014
  • Objectives: The purpose of this study was to compare the cutting efficiency of a newly developed microprojection tip and a diamond-coated tip under two different engine powers. Materials and Methods: The apical 3 mm of each root was resected, and root-end preparation was performed with upward and downward pressure using one of the ultrasonic tips, KIS-1D (Obtura Spartan) or JT-5B (B&L Biotech Ltd.). The ultrasonic engine was set to power-1 or -4. Forty teeth were randomly divided into four groups: K1 (KIS-1D / Power-1), J1 (JT-5B / Power-1), K4 (KIS-1D / Power-4), and J4 (JT-5B / Power-4). The total time required for root-end preparation was recorded. All teeth were resected and the apical parts were evaluated for the number and length of cracks using a confocal scanning micrscope. The size of the root-end cavity and the width of the remaining dentin were recorded. The data were statistically analyzed using two-way analysis of variance and a Mann-Whitney test. Results: There was no significant difference in the time required between the instrument groups, but the power-4 groups showed reduced preparation time for both instrument groups (p < 0.05). The K4 and J4 groups with a power-4 showed a significantly higher crack formation and a longer crack irrespective of the instruments. There was no significant difference in the remaining dentin thickness or any of the parameters after preparation. Conclusions: Ultrasonic tips with microprojections would be an option to substitute for the conventional ultrasonic tips with a diamond coating with the same clinical efficiency.

초음파 트랜스듀서의 종진동을 이용한 알루미늄 와이어 용접 (Aluminum Wire Bonding by Longitudinal Vibration of Ultrasonic Transducer)

  • Lee, G.B.;Kim, H.S.
    • 한국정밀공학회지
    • /
    • 제13권11호
    • /
    • pp.38-45
    • /
    • 1996
  • In recent years, ultrasonic has been widely applied in measurement and industrial fields and its application range has been expanded as a result of continuous research and development. Wire Bonding Machine, an instrument fabricating semi-conductor, makes use of ultrasonic bonding method. Specially, the method utilizes the longitudinal vibration of ultrasonic transducer composed of piezoelectric vibrator and horn. This work investigates the design conditions affecting the dynamic characteristics through the theretical and experimental analysis. It conducts separately the system identification of piezoelectric vibrator in time domain and the modal analysis of horn in frequency domain. The integrated modeling is conducted via a combbination of dynamic identification of piezoelectric vibrator and theroretical analysis of horn. Then comparison is made for theroretical and experimental results of the dynamic characteristics of the ultrasonic transducer comprised of piezoelectric vibrator and horn. Form the results of the comparison we develop the design technique of ultrasonic transducer using dynamic characteristics analysis and propose the possibility of ultrasonic bonding considering the optimal conditions for the longitudinal vibration of ultrasonic transducer and other conditions.

  • PDF

초음파 진동자를 이용한 알루미늄 와이어 용접에 관한 연구 (A Study on the Aluminum Wire Bondingby Using Ultrasonic Vibrator)

  • 김희수;이건복
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.571-576
    • /
    • 1994
  • In recent years, ultrasonic has been widely applied in measurement and industrial fields and its application range has been expanded as a result of continuous research and development. Wire Bonding Machine, an instrument fabricating semi-conductor, makes use of ultrasonic bonding method. In order to improve the currently used wire bonding machine using ultrasonic energy, technical accumulation is needed steadily through development of exciting device of ultrasonic composed of piezoelectic vibrator and horn. This study investigates the design conditions affecting the dynamic characteristics through the theoretical and experimental analysis of piezoelectric vibrator and horn, The study conducts separately the system identification of piezoelectric vibrator in time domain and the modal analysis of horn in frequency domain. In theoretical model, the integrated modeling is conducted via a combination of dynamic identification of piezoelectric vibrator and theoretical analysis of horn. Hence comparison is made for theoretical and experimental results of the dynamic characteristics of the ultrasonic transducer composed of piezoelectric vibrator and horn. Form the results of this study we develop the design technique of ultrasonic transducer using dynamic characteristic analysis and propose the possibility of ultrasonic welding considering the optimal condition of the natural frequency and vibration mode of horn.

  • PDF

치과용 골 수술기의 초음파 진동자 설계 및 평가 (Evaluation and Design of Ultrasonic Vibrator for Dental Surgery)

  • 박기문;김정현;고태조
    • 한국기계가공학회지
    • /
    • 제15권3호
    • /
    • pp.102-108
    • /
    • 2016
  • A dental ultrasonic surgical instrument, commercially known as a scaler, is a high-value-added advanced technology that is used for tartar removal, implant operations, and gum and jaw bone surgery. In this study, the piezoelectric phenomenon for making linear motion associated with input electrical signals was studied, and the behavior of the ultrasonic vibrator was investigated by using the commercially available finite element program ANSYS(R) for the purpose of designing dental surgery tools. Modal analysis was carried out, and the optimal frequency range was calculated from the analyzed results. The ultrasonic vibrator was then redesigned based on the calculated optimal frequency range. The performance of the system was tested, and consequently, the proposed methodology was proven useful in vibrator design.

초음파 측정에 의한 변압기내 부분방전 위치측정 (Location of Partial Discharge in Oil Transformer by means of Ultrasonic measurement)

  • 곽희로;전희종;김재철;황선주;윤용한;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 추계학술대회 논문집 학회본부
    • /
    • pp.415-418
    • /
    • 1991
  • This paper described an instrument for the detection and geometric location of partial discharge(PD) sources in oil transformer. This instrument measures electric current pulse and ultrasonic pulse simultaneously in order to determine the geometric location of PD in transformer. Laboratory experiment systems are made for detection and location of PD in oil transformer. It was observed that there are effects of the barrier, such as insulation papers, silicon steel plate and actual transformer with location and detection of PD in model transformer. Through the laboratory actual test, it was clarified that this measurement device could be used satisfactorily for location of pd in oil transformer.

  • PDF

위상차 변화에 따른 초음파 모터의 주파수-속도 특성 (The Frequency-Speed Characteristics of Ultrasonic Motor by the Change of Phase difference)

  • 김동옥;정국영;오금곤;김영동
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(1)
    • /
    • pp.146-149
    • /
    • 2003
  • To control the position, velocity and torque of the ultrasonic motor, a great variety of method are proposed such as the amplitude, phase difference, frequency and so on. In the case of phase difference method, it has some advantages: it can control the direction and velocity of rotation only adjusting the phase difference and it has wide control-band. During the USM driving on adjusting phase difference, its characteristic was transformed by the change of resonance-frequency of stator, which means that the resonance frequency is different according to the phase difference. Consequently, we need to set up the most suitable driving frequency according to each phase difference.

  • PDF

신경회로망을 이용한 오스테나이트계 스테인리스강 304 용접부의 결함 분류 및 평가에 관한 연구 (A Study on the Defect Classification and Evaluation in Weld Zone of Austenitic Stainless Steel 304 Using Neural Network)

  • 이원;윤인식
    • 한국정밀공학회지
    • /
    • 제15권7호
    • /
    • pp.149-159
    • /
    • 1998
  • The importance of soundness and safety evaluation in weld zone using by the ultrasonic wave has been recently increased rapidly because of the collapses of huge structures and safety accidents. Especially, the ultrasonic method that has been often used for a major non-destructive testing(NDT) technique in many engineering fields plays an important role as a volume test method. Hence, the defecting any defects of weld Bone in austenitic stainless steel type 304 using by ultrasonic wave and neural network is explored in this paper. In order to detect defects, a distance amplitude curve on standard scan sensitivity and preliminary scan sensitivity represented of the relation between ultrasonic probe, instrument, and materials was drawn based on a quantitative standard. Also, a total of 93% of defect types by testing 30 defect patterns after organizing neural network system, which is learned with an accuracy of 99%, based on ultrasonic evaluation is distinguished in order to classify defects such as holes or notches in experimental results. Thus, the proposed ultrasonic wave and neural network is useful for defect detection and Ultrasonic Non-Destructive Evaluation(UNDE) of weld zone in austenitic stainless steel 304.

  • PDF

초음파 근관기구를 이용한 근관충전법의 근관폐쇄능에 관한 주사 전자현미경적 연구 (A SCANNING ELECTRON MICROSCOPIC EVALUATION OF THE ROOT CANAL FILLING WITH ULTRASONIC ENDODONTIC INSTRUMENT)

  • 최라영;이인숙
    • Restorative Dentistry and Endodontics
    • /
    • 제15권2호
    • /
    • pp.104-114
    • /
    • 1990
  • The purpose of this study was to evaluate the adaptation of root canal filling material to the dentinal wall of root canal and to compare the sealing ability of the root canal filling materials using ultrasonic endodontic instrument with injection-molded thermoplasticized gutta-percha filling method and lateral condensation method. Fifty fresh human single root exlracted for orthodontic treatment, were randomly selected, and instrumented by step-back technique. And then, the teeth were divided into 5 groups according to each root canal filling methods. In the experimental group 1 and group 2, the root canals were filled with gutta perdia cases using ultrasonic instrument with and without sealer. In the experimental group 3 and 4, using jection-moldeed thermoplasticized gutta-percha method by obtul$^{(R)}$ canals were filled with and without sealer. In the control group, the canals were filled with sealer by lateral candensation. And then, 5 teeth of each group were immersed in black Indian ink, decalcified and cleared. The depth of dye penetration into the root canal were evaluated with stereoscope (Reichert Ltd., USA). Among the 5 teeth remaining in each group, the single longituding grooves were made on the labial and lingual root surfaces and then immersed in the liquid nitrogen to fracture the teeth spontaneously without any distortions of gutta-percha. Each specimens were examined with X-650 Scanning Electron Microscope(Hitachi ltd, Japan) to show the adaptation to the canal wall, void, homogenicity of filling material and location of gutta-percha or sealer in the dentinal tubules of the root canal. The observations were as follows : 1. The experimental group 1 showed smaller mean dye penetration than control group, and showed the penetraton of sealer in the dentinal tubules of apical third of the root canal. 2. The experimental group 2 and group 4 showed the penetration of gutta-percha in the dentinal tubules of root canals. 3. The experimental group 1 and group 3 showed less mean dye penetration than the experimental group 2 and group 4. 4. The experimental group 1 and group 2 showed better adaptation of filling materials than control group.

  • PDF

초음파 이송장치에서 탄성 빔의 진동을 이용한 물체 이송방향 제어 (Control of Object Transport Direction Using Vibration of Flexural Beam in Ultrasonic Transport System)

  • 정상화;박진완
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 추계학술대회논문집
    • /
    • pp.1241-1246
    • /
    • 2007
  • In recent years, the semiconductor industry and the optical industry are developed rapidly. The recent demands have expanded for optical components such as the optical lens, the optical semiconductor and the measuring instrument. Object transport systems are driven typically by the magnetic field and the conveyer belt. Recent industry requires more faster and efficient transport system. However, conventional transport systems are not adequate for transportation of optical elements and semiconductors. The conveyor belts can damage precision optical elements by the contact force and magnetic systems can destroy the inner structure of semiconductor by the magnetic field. In this paper, the levitation transport system using ultrasonic wave is developed for transporting precision elements without damages. The steady state flexural vibration of the beam is expressed using Euler-Bernoulli beam theory. The transport direction of an object is examined according to phase difference and frequency. The theoretical results are verified by experiments.

  • PDF

두개의 탐촉자를 사용한 등방성 균일 고체의 초음파 속도 및 두께 동시 측정법 (Simultaneous Measurement of Ultrasonic Velocity and Thickness of Isotropic and Homogeneous Solids Using Two Transducers)

  • 이정기;권진오;김영환
    • 비파괴검사학회지
    • /
    • 제19권5호
    • /
    • pp.363-368
    • /
    • 1999
  • 시험체의 두께나 초음파 속도를 측정하기 위해서 초음파 펄스-에코법이 널리 사용되고 있다. 초음파 속도를 결정하기 위해서는 초음파 송수신 장치를 포함한 오실로스코우프와 같은 초음파 측정 장치를 사용하여 시험편에서의 초음파진행 시간을 측정하고, 초음파 진행 거리에 해당하는 시험편의 두께를 버어니어 캘리퍼스 또는 마이크로미터와 같은 길이측정 도구를 사용하여 측정한다. 그리고 초음파를 이용하여 시험편의 두께를 측정할 때에는 초음파 속도를 알고 있는 대비 시험편으로 기준을 설정하여야 한다. 본 연구에서는, 대비 시험편 없이 재료의 두께와 초음파 속도를 동시에 구하는 방법을 제시하였다. 재질과 두께를 달리한 여러 시험편에서 측정된 초음파 속도와 두께가 기존의 방법에 의해 측정한 값과 잘 일치하였다.

  • PDF