• Title/Summary/Keyword: ultrasonic field analysis

Search Result 104, Processing Time 0.022 seconds

Quantitative evaluating method for diagnostic ultrasound probe using 3-dimensional acoustic field analysis (3차원 음장 분석법을 이용한 진단용 초음파 프로브의 정량적 성능평가)

  • Noh, Si-Cheol;Kim, Ju-Young;Park, Jae-Hyun;Kim, Jin-Su;Kang, Jung-Hoon;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.490-496
    • /
    • 2010
  • In this study, in order to overcome the weakness of acoustic field analysis which is generally used for ultrasonic probe performance evaluation, automatic acoustic field measurement system and evaluation parameters were proposed. The comparisons between acoustic field simulation and measured acoustic distribution data of normal and abnormal channels were conducted to evaluate the availability of proposed system and evaluation parameters. First, the impulse response characteristic of sample probe was investigated to classify the normal elements and abnormal elements. And then, normal channels and abnormal channels with abnormal element were chosen. The suggested 12 evaluation parameters were calculated using the acoustic fields of these channels. The availability of proposed automatic acoustic field measurement system and evaluation parameters was confirmed. And the performance evaluation of ultrasonic probe using acoustic field analysis could be easier and faster.

A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division (채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구)

  • Yoo, B.C.;Choi, H.H.;Noh, S.C.;Min, H.K.;Kwon, J.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.5
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

A Study on Performance Prediction for a Magnetostrictive Ultrasonic Transducer According to Arrangement of Permanent Magnets for Biasing (바이어스 자기장용 영구자석 배치에 따른 자왜 초음파 변환기 성능 예측에 관한 연구)

  • Lee, Ho-Cheol
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.20 no.12
    • /
    • pp.1200-1209
    • /
    • 2010
  • The main subject of this paper is to develop analytic method with which output power or sensitivity variations of a magnetostrictive ultrasonic transducer can be estimated with no aid of experiments. After the bias magnetic field deployed over the patch is calculated using finite element analysis for magnetostatics, the representative value is extracted by averaging these field values. The operating point on the characteristic curve for magnetostriction is identified by this value and then the output performance is calculated from it. It is verified that the results from this simple model match well with those of its experimental version and some limits of this modeling technique are also considered.

Development of sensors with mode-selective measuring capability of ultrasonic waves traveling on a cylindrical shaft (축을 따라 전파되는 초음파 모드의 선택적 측정이 가능한 센서 개발)

  • Lee, Ho-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.336-339
    • /
    • 2007
  • A sensor having capability to measure two different kinds of ultrasonic waves selectively is described. Under the same bias field configuration, this magnetostrictive type sensor can selectively measure longitudinal waves and flexural ones. Since the switching operation of mode selection is made only by changing the polarity of the permanent magnets used to configure the bias field, it will be very useful after the permanent magnet are interchanged with electromagnets. In order to find the optimal operating bias field, finite elements analysis is used and the condition for flexural wave measurements to meet is found. The linearity of the sensor is verified by experiments and the requirements for linearity also are proposed.

  • PDF

The Study on Scattered Far-Field Analysis of Ultrasonic SH-Wave Using Boundary Element Method (경계요소법을 이용한 SH형 초음파 원거리 산란장 해석에 관한 연구)

  • Lee, Joon-Hyun;Lee, Seo-Il
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.5
    • /
    • pp.333-339
    • /
    • 1999
  • It is well recognized that ultrasonic technique is one of the most common and reliable nondestructive evaluation techniques for quantitative estimation of defects in structures. For the quantitative and accurate estimation of internal defects. the characteristics of scattered ultrasonic wavefields must be understood. In this study. the scattered near-field and far-field due to a circular cavity embedded in infinite media subjected to incident SH-waves were calculated by the boundary element method. The frequency response of the scattered ultrasonic far-field was transformed into the time-domain signal by obtaining its inverse Fourier transform. It was found that the amplitude of time-domain signal decreases and its time delay increases as the distance between the detecting point of ultrasonic scattered field and the center of internal cavity increases.

  • PDF

A Study on Scattered Fields Analysis of Ultrasonic SH-Wave from Multi-Defects by Boundary Element Method (경계요소법을 이용한 다중결함의 SH형 초음파 산란장 해석에 관한 연구)

  • Lee, Jun-Hyeon;Lee, Seo-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.23 no.11 s.170
    • /
    • pp.1878-1885
    • /
    • 1999
  • Ultrasonic technique which is one of the most common nondestructive evaluation techniques has been applied to evaluate the integrity of structures by analyzing the characteristic of scattering sign al from internal defects. Therefore, a numerical analysis of ultrasonic scattering field due to defect profiles is absolutely needed for the accurate, quantitative estimation of internal defects. In this paper, the SH-wave scattering by multi-cavity defects and inclusion using Elastodynamic Boundary Element Method is studied. The effects of shape and distance of defects on transmitted and reflected fields are considered. The interaction of multi-cavity defects in SH-wave scattering is also investigated. Numerical calculations by the BEM have been carried out to predict near field solution of scattered fields of ultrasonic SH-wave. The presented results can be used to improve the detection sensitivity and pursue quantitative nondestructive evaluation for inverse problem.

Numerical Analysis on the Signal Characteristics for Scattered Far-field of Ultrasonic SH-Wave by the Internal Cavity (재료내 기공결함에 의한 SH형 초음파 원거리 산란장의 신호특성에 대한 수치해석)

  • Lee, Jun-Hyeon;Lee, Seo-Il;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.1 s.173
    • /
    • pp.163-172
    • /
    • 2000
  • In this study, the scattered far-field due to a cavity embedded in infinite media subjected to the incident SH-wave was calculated by the boundary element method. The effects of cavity shape and distance between internal cavity and internal point in infinite media were considered. The scattered far-field of the frequency domain was transformed into the signal of the time domain by using the Inverse Fast Fourier Transform(IFFT). It was found that the amplitude of scattered signal in time domain decreased with the increase of the distance between the detecting points of ultrasonic scattered field and the center of internal cavity in media. In addition, the time delay was clearly found in time domain waveform as the distance between the detecting points of ultrasonic scattered field and the center of internal cavity was gradually increased.

Continuous Microalgae Separation Process Using Ultrasonic Waves (초음파를 이용한 미세조류 연속분리공정)

  • Kim, Sung Bok;Jeong, Sang Hwa
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.4
    • /
    • pp.407-413
    • /
    • 2015
  • Research for renewable energy is being performed since it has the merits of little pollution of the environment and sustainable energy resources. Microalgae is attractive as a renewable energy resource. Biomass of the microalgae can be produced by mass culturing, and bulk harvest technology of is needed to produce biomass continuously. Recently, ultrasonic waves were used to harvest the cultivated microalgae continuously. In this study, the separation process using ultrasonic waves was performed to effectively harvest the microalgae. An ultrasonic wave separation resonator was designed and manufactured based on the acoustic field analysis. Separation experiments using design of experiment were carried out, and the influence of experimental variables from the ultrasonic wave separation process was investigated. Mixing conditions of variables were estimated to obtain high separation efficiency and a large microalgae harvest. Experimental results for suitable mixing conditions were compared with simulation results calculated from the state equation.

Analysis of Broadband Ultrasonic Field Response and its Application to the Design of Focused Annular Array System (광대역 초음파 장 응답의 해석과 집속된 Annular Array 영상 시스템 설계에의 응용)

  • Rho, Gyoung-Tae;Song, Tae-Kyung;Park, Song-Bae
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1252-1255
    • /
    • 1987
  • In this paper an approach for the analysis of the transient field response of radially symmetric transducer due to a wideband ultrasonic pulse is presented, which is based on a development of Green's function and applies the linear system theory to obtain an analytic expression for the impulse response of an annulus with a planar or spherical geometry. For the focused annular array, the impulse responses of the indivisual annuli are convolved with the delayed excitation pulse, and then summed to obtain the resultant response of the array. This process is very effective in the study of the various focusing abilities of the annular array. For illustration, the field distribution of a five element annular array is treated in detail for several focusing system.

  • PDF

Research for Signal Analysis of 18Mn-5Cr Steel Generator Retaining Ring using Ultrasonic Wave (초음파를 이용한 18Mn-5Cr강 발전기 리테이닝 링의 신호분석에 관한 연구)

  • Gil, D.S.;Ahn, Y.S.;Park, S.K.
    • Journal of Power System Engineering
    • /
    • v.14 no.2
    • /
    • pp.65-70
    • /
    • 2010
  • Retaining rings are used to support the field winding end turns from the centrifugal force by the high speed of the field and these are the overstressed parts among the generator parts. There have been several retaining failures in Europe and America, all attributable to stress corrosion cracking in 18Mn-5Cr steel. Since then, each manufacture companies have developed a good 18Mn-5Cr steel in temperature, strength characteristic and it is used in many field now. From many findings and test results, we could conformed that the failure might be grown in the overstressed condition unrelated to the moisture particle.