• Title/Summary/Keyword: ultrasonic array

Search Result 210, Processing Time 0.023 seconds

A Study on Continuous long-term Wave Observation using Remote Monitoring System (원격모니터링을 이용한 연속파랑관측에 관한 연구)

  • Shin, Bumshick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.654-659
    • /
    • 2018
  • In this study, continuous long-term observation is implemented with an ocean radar. Ocean radar conducts remote observation (combined) with ground-based radars, which enable a series of simultaneous observations of an extensive range of the coast with high frequency. An ocean radar for continuous long-term observation is operated at Samcheok on the east coast of Korea. Samcheok experienced tsunami damage in recent years and is the location of a nuclear power plant. In order to examine the reliability of the ocean radar, a pressure-type wave gauge, ultrasonic wave gauge, and ocean buoy are installed for the purpose of data comparison and verification. The ocean radar used in this study is an array-type HF-RADAR named WERA (WavE RAdar). The analysis of the data obtained from continuous long-term observations showed that the radar observations were in agreement with more than 90% of the wave data collected within a 25 km range from the center of two sites. Less than 1% of the entire observation data was unmeasured by the time series analysis. As a result of comparing the radar data with the direct observations made by the wave gauge, it was inferred that the RMS deviation is less than 20cm and the correlation coefficient was in the range of 0.84 ~ 0.87. Moreover, supported by such observations, a comprehensive monitoring system is being developed to provide the public with real-time reports on waves and currents via the internet.

A Study about Measurement Method for Quantitative Classification of Breeding Pig's Locomotor Behaviors using Ultrasonic Sensor Array (초음파 센서 어레이를 이용한 모돈 지제이상 정량분석 방법 연구)

  • Cho, Jinho;Oh, Jong-woo;Lee, DongHoon
    • Proceedings of the Korean Society for Agricultural Machinery Conference
    • /
    • 2017.04a
    • /
    • pp.163-163
    • /
    • 2017
  • 모돈은 교배, 임신, 분만, 포유, 이유를 순환적 반복을 요구하는 개체로서 스마트 농장 시스템의 생산성 향상에 있어서 중요한 요소이다. 본 연구에서는 모돈 능력의 극대화 및 최적의 시스템 관리를 위해서 초음파 센서를 활용한 모돈의 지제 이상 징후를 실시간으로 계측할 수 있는 시스템을 개발하였다. 이 시스템은 높이에 따라 상-중-하(30 cm 간격), 위치에 따라 전면부-후면부에 초음파 센서를 설치하고 이를 마이크로 컨트롤러에 연결하여 모돈의 지제 이상 유무 측정이 가능하도록 하였다. 모돈의 체형과 위치를 고려하여 설치된 초음파 센서의 위치 조절이 가능하도록 하였다. 또한 소형 LCD 모듈을 내장하여 실시간 모니터링이 가능하도록 하였으며, 측정된 데이터는 저장장치인 microSD 카드에 저장되도록 하였다. 모돈사의 환경을 고려하여 방밀형 구조로 하우징 마감하였다. 이 모돈 지체 이상 분석 시스템에 사용된 툴은 C언어를 이용하였다. 건강한 모돈을 대상으로 모돈의 지제의 관찰을 위하여 총 12회의 현장 실증실험이 수행되었으며, 현장 실증 시험 중 소요된 시간은 현장의 상황에 따라 다소 상이하였다 (8시간-28일). 높이 상에 위치한 전면부 및 후면부 초음파 센서 모두에서 모돈이 검출이 된 경우 정상 기립으로 간주하였고, 높이 상에 위치한 전면-후면부 초음파 센서 모두에서 모돈이 검출이 되지 않은 경우 정상적으로 누워 있는 걸로 간주하였다. 높이 하에 위치한 전면부 혹은 후면부 초음파 센서 한곳만 모돈이 검출된 경우 비정상적인 기립으로 간주하였다. 취득된 데이터를 분석한 결과 모돈의 정상적 상태 (기립상태, 누운 상태, 앉은 상태)와 그 외의 비정상적 상태로 분류가 가능하다. 또한 측정된 초음파 센서의 진동의 유무 및 파동형태에 따라서 모돈의 상태 예측이 가능하다. 초음파 센서의 진동 파동이 크고 안정된 상태인 경우 정상적인 활동 상태로 판단하였으며, 진동 파동이 작고 안정적인 경우는 수면 상태로 분류하였다. 실시간으로 지속적인 데이터 획득을 위하여 차후 초음파 센서 및 시스템의 보완작업이 필요하다. 이와같은 모돈의 행동 패턴에 따른 취득된 데이터를 분류하여 모돈의 발정에 의한 행동 특성(기립시간) 분석에 따른 발정 적기 발견 및 정량화 기술 개발에 활용이 가능하다.

  • PDF

The Theoretical Investigation of Phased Array Guided Waves (위상배열 유도초음파 검사의 이론적 고찰)

  • Lee, Jae-Sun;Cho, Youn-Ho;Achenbach, Jan D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.4
    • /
    • pp.367-373
    • /
    • 2011
  • Guided waves inspection techniques that are different with inspection technique by bulk waves are widely used in pipe line evaluation due to advantages of long distance inspection. However, most of pipe lines at industrial fields are buried and/or coated. In this case, due to the attenuation effect from soil and/or coating material, there are a lot of difficulty on inspection by conventional ultrasonic technique. In this paper, guided waves propagating patterns are calculated with respect to excitation mode by Normal Mode Expansion(NME). Guided waves patterns based on excited by single transducer and guided wave focusing technique have employed to analyze focusing pattern on a pipe. A longitudinal mode and high order flexural modes are used with various number of transducers to determine sensitivity. Guided waves energy excited by multi transducer with focusing algorithm was successfully focused at a desired point.

An Experimental Study of the Synthetic Sinc Wave in Ultrasonic Imaging (초음파 의료 영상에서 합성 Sinc 음장 집속방법의 실험적 고찰)

  • 이광주;정목근
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.3
    • /
    • pp.243-251
    • /
    • 2002
  • Synthetic zinc wave employs Pulsed plane wave as transmit beam with linear time delay curve. The received echoes in different transmit directions at different transmit times are superposed at imaging Points with Proper time delay compensation using synthetic focusing scheme. This scheme. which uses full aperture in transmit, obtains a high SNR image, and also features high lateral resolution by using two way dynamic focusing at all imaging depths. In this Paper, we consider the Problems in realization of synthetic zinc wave. Also. we have applied the scheme to obtain phantom and in-vivo images using a linear array of 5 MHz. In phantom test. experimental images show high resolution over a more extended imaging depth than conventional fixed Point transmit and receive dynamic focusing schemes In-vivo images show that the resolution could not overcome conventional focusing systems because of motion blurring and(or) aberration of tissue. but the frame rate tan be increased by a factor of more than 5 compared to conventional focusing schemes. with competitive resolution at all imaging depths .

Signal Processing in Medical Ultrasound B-mode Imaging (의료용 초음파 B-모드 영상을 위한 신호처리)

  • Song, Tai-Kyong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.521-537
    • /
    • 2000
  • Ultrasonic imaging is the most widely used modality among modern imaging device for medical diagnosis and the system performance has been improved dramatically since early 90's due to the rapid advances in DSP performance and VLSI technology that made it possible to employ more sophisticated algorithms. This paper describes "main stream" digital signal processing functions along with the associated implementation considerations in modern medical ultrasound imaging systems. Topics covered include signal processing methods for resolution improvement, ultrasound imaging system architectures, roles and necessity of the applications of DSP and VLSI technology in the development of the medical ultrasound imaging systems, and array signal processing techniques for ultrasound focusing.

  • PDF

Optimization of Extraction Conditions for Swertiamarin in Swertia japonica Makino (당약의 swertiamarin 분석을 위한 추출조건 최적화)

  • Kim, Tae Hee;Jang, Seol;Lee, Ah Reum;Lee, A Young;Choi, Goya;Kim, Ho Kyoung
    • The Korea Journal of Herbology
    • /
    • v.29 no.1
    • /
    • pp.13-18
    • /
    • 2014
  • Objectives : Iridoid glycoside, swertiamarin is a well known bioactive component found in Swertia japonica Makino (SJ). In this study, we tried to optimize a suitable method which would extract swertiamarin effectively. Methods : Extraction of SJ was carried out by various conditions of time (5 - 60 min), temperature ($30-70^{\circ}C$), solvent (from non-polar to polar), and ratio of solvnet / sample (10 : 1 - 40 : 1) using ultrasonic extractor. Swertiamarin in SJ extracts was quantified by high performance liquid chromatography - Phtodiode array detector (HPLC-PDA) using C18 column and the analytical procedure was validated by evaluation of specificity, range, linearity, accuracy (recovery), precision (intra- and inter day variability), limit of detection (LOD), and limit of quantification (LOQ). Results : An efficient extraction condition for swertiamarin in SJ was optimized using sonicator extraction (temperature $40^{\circ}C$, solvent 20% methanol, solvent / sample (20 : 1), and time 10 min. Analytical procedure was optimized by HPLC-PDA using isocratic solvent system of acetonitrile and water (9 : 91), and the method was validated in regard to linearity (correlation coefficient, $R^2$ > 0.9999), range ($50-1000{\mu}g/mL$), intra- and inter-precision (RSD < 5.0 %), and recovery (99 -103 %). LOD and LOQ were 0.051 and $0.155{\mu}g/mL$, respectively. Conclusion : An optimized method of extraction for swertiamarin in SJ was established through conditions of diverse extraction and the validation result indicated that the method is suited for the determination of swertiamarin in SJ.

Phytochemical analysis of Panax species: a review

  • Yang, Yuangui;Ju, Zhengcai;Yang, Yingbo;Zhang, Yanhai;Yang, Li;Wang, Zhengtao
    • Journal of Ginseng Research
    • /
    • v.45 no.1
    • /
    • pp.1-21
    • /
    • 2021
  • Panax species have gained numerous attentions because of their various biological effects on cardiovascular, kidney, reproductive diseases known for a long time. Recently, advanced analytical methods including thin layer chromatography, high-performance thin layer chromatography, gas chromatography, high-performance liquid chromatography, ultra-high performance liquid chromatography with tandem ultraviolet, diode array detector, evaporative light scattering detector, and mass detector, two-dimensional high-performance liquid chromatography, high speed counter-current chromatography, high speed centrifugal partition chromatography, micellar electrokinetic chromatography, high-performance anion-exchange chromatography, ambient ionization mass spectrometry, molecularly imprinted polymer, enzyme immunoassay, 1H-NMR, and infrared spectroscopy have been used to identify and evaluate chemical constituents in Panax species. Moreover, Soxhlet extraction, heat reflux extraction, ultrasonic extraction, solid phase extraction, microwave-assisted extraction, pressurized liquid extraction, enzyme-assisted extraction, acceleration solvent extraction, matrix solid phase dispersion extraction, and pulsed electric field are discussed. In this review, a total of 219 articles published from 1980 to 2018 are investigated. Panax species including P. notoginseng, P. quinquefolius, sand P. ginseng in the raw and processed forms from different parts, geographical origins, and growing times are studied. Furthermore, the potential biomarkers are screened through the previous articles. It is expected that the review can provide a fundamental for further studies.

Comparison of Major Compounds in Illicii Veri Fructus by Extraction Solvents (추출용매에 따른 팔각회향의 주성분 함량비교)

  • Lee, A Yeong;Kim, Hyo Seon;Choi, Goya;Chun, Jin Mi;Moon, Byeong Cheol;Kim, Ho Kyoung
    • The Korea Journal of Herbology
    • /
    • v.28 no.6
    • /
    • pp.47-51
    • /
    • 2013
  • Objectives : The Illicii Veri Fructus was not only traditional medicine but also food in Asia. The aim of this study was selection of optimum solvent in the fruit of Illicii Veri Fructus because an appropriate solvent affect a medicinal effect. Methods : Illicii Veri Fructus was carried out ultrasonic-assisted extraction as various solvents. Two main compounds, p-anisaldehyde and anethole, were successfully analyzed by high performance liquid chromatography-photodiode array detector (HPLC-PDA) and carried out method validation according to ICH guideline. The optimum solvent selected by comparing with yields of two main ingredients. Results : The p-anisaldehyde and anethole were detected at approximately 8.0 min and 19.8 min, respectively. It was all below 5.0% that RSD of retention time and peak area for two main peaks. Calibration curves of two compounds were good linearity as $R^2$ >0.9999. All of the precisions and accuracy were good intra-day and inter-day as below 5.0% RSD. Limited of detection (LOD) of p-anisaldehyde and anethole were analyzed as $0.134{\mu}g/mL$ and $4.286{\mu}g$, respectively. Limited of quantification (LOQ) of two compounds were $0.407{\mu}g$ and $12.989{\mu}g$, respectively. As a result of this study, p-anisladehyde was detected as 0.209 ~ 0.467%, however anethole was not detected in the distilled water. Conclusions : Anethole was main component as 5.329 ~ 6.815% except for water extraction. Methanol extraction among various solvents was detected the highest contents of p-anisaldehyde and anethole as 0.467(${\pm}0.008$)% and 6.815(${\pm}0.220$)%, respectively.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Development of a split beam transducer for measuring fish size distribution (어체 크기의 자동 식별을 위한 split beam 음향 변환기의 재발)

  • 이대재;신형일
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.196-213
    • /
    • 2001
  • A split beam ultrasonic transducer operating at a frequency of 70 kHz to use in the fish sizing echo sounder was developed and the acoustic radiation characteristics were experimentally analyzed. The amplitude shading method utilizing the properties of the Chebyshev polynomials was used to obtain side lobe levels below -20 dB and to optimize the relationship between main beam width and side lobe level of the transducer, and the amplitude shading coefficient to each of the elements was achieved by changing the amplitude contribution of elements with 4 weighting transformers embodied in the planar array transducer assembly. The planar array split beam transducer assembly was composed of 36 piezoelectric ceramics (NEPEC N-21, Tokin) of rod type of 10 mm in diameter and 18.7 mm in length of 70 kHz arranged in the rectangular configuration, and the 4 electrical inputs were supplied to the beamformer. A series of impedance measurements were conducted to check the uniformity of the individual quadrants, and also in the configurations of reception and transmission, resonant frequency, and the transmitting and receiving characteristics were measured in the water tank and analyzed, respectively. The results obtained are summarized as follows : 1. Average resonant and antiresonant frequencies of electrical impedance for four quadrants of the split beam transducer in water were 69.8 kHz and 83.0 kHz, respectively. Average electrical impedance for each individual transducer quadrant was 49.2$\Omega$ at resonant frequency and 704.7$\Omega$ at antiresonant frequency. 2. The resonance peak in the transmitting voltage response (TVR) for four quadrants of the split beam transducer was observed all at 70.0 kHz and the value of TVR was all about 165.5 dB re 1 $\mu$Pa/V at 1 m at 70.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The resonance peak in the receiving sensitivity (SRT) for four combined quadrants (quad LU+LL, quad RU+RL, quad LU+RU, quad LL+RL) of the split beam transducer was observed all at 75.0 kHz and the value of SRT was all about -177.7 dB re 1 V/$\mu$Pa at 75.0 kHz with bandwidth of 10.0 kHz between -3 dB down points. The sum beam transmitting voltage response and receiving senstivity was 175.0 dB re 1$\mu$Pa/V at 1 m at 75.0 kHz with bandwidth of 10.0 kHz, respectively. 3. The sum beam of split beam transducer was approximately circular with a half beam angle of $9.0^\circ$ at -3 dB points all in both axis of the horizontal plane and the vertical plane. The first measured side lobe levels for the sum beam of split beam transducer were -19.7 dB at $22^\circ$ and -19.4 dB at $-26^\circ$ in the horizontal plane, respectively and -20.1 dB at $22^\circ$ and -22.0 dB at $-26^\circ$ in the vertical plane, respectively. 4. The developed split beam transducer was tested to estimate the angular position of the target in the beam through split beam phase measurements, and the beam pattern loss for target strength corrections was measured and analyzed.

  • PDF