• Title/Summary/Keyword: ultra high molecular weight of polyethylene (UHMWPE)

Search Result 59, Processing Time 0.021 seconds

Effect of Heat Treatment on Mechanical Properties of Cross-Linked Ultra-High Molecular Weight Polyethylene Used for Artificial Joint Liner (인공관절 라이너용 가교된 초고분자량폴리에틸렌(UHMWPE)의 열처리 조건에 따른 기계적 특성 변화)

  • Kim, Hyun-Mook;Kim, Dong-Hoon;Gu, Ja-Uk;Choi, Nak-Sam;Kim, Sung-Kon
    • Composites Research
    • /
    • v.22 no.2
    • /
    • pp.1-6
    • /
    • 2009
  • The mechanical characteristics of gamma-ray irradiated UHMWPE specimens were investigated under various heat treatment conditions. The heat treatment was performed in the range of annealing and remelting temperatures. The annealing treatment below the temperature of $130^{\circ}C$ hardly induced changes in the tensile strength, the strain at the failure and the hardness. However the remelting treatment above $140^{\circ}C$ deteriorated those mechanical properties. It was shown in an FTIR analysis that the annealing treatment caused some oxidation of free radicals created by the pretreatment of the irradiation. These quantitative data represented by the behavior of mechanical properties might be used as basic informations for the design and analysis of various artificial joints.

Hemiarthroplasty for Osteosarcoma of Proximal Tibia (근위 경골의 골육종에 시행한 반관절성형술)

  • Jeon, Dae-Geun;Cho, Wan-Hyeong;Kim, Jin-Wook-;Koh, Han-Sang
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.12 no.1
    • /
    • pp.9-14
    • /
    • 2006
  • Purpose: The proximal tibial sarcoma patients, especially in their growing ages have problems of reconstruction. This study is to devise a methodology which can circumvent this limitations. Materials and Methods: Four cases of proximal tibial osteosarcoma underwent hemiarthroplasty. The mean age was 13 years (11~15) with a mean follow-up of 64 months (47~89). The procedure consists of ultrahigh molecular weight polyethylene (UHMWPE) liner as an substitute for the joint surface and this piece was fixed to the remaining tibial bone stock with Ender nail and bone cement. Results: Final functional score was 23.5 (78.3% of control) by MSTS criteria. All the cases showed stable joint without pain. Hemiarthroplasty related complications were absent. By saving the femoral physis, expected leg length discrepancy could be minimized by this procedure. Conclusions: Hemiarthroplasty of proximal tibia can be an option in pediatric sarcoma patients.

  • PDF

Surface and Chemical Properties of Surface-modified UHMWPE Powder and Mechanical Properties of Self Curing PMMA Bone Cement Containing UHMWPE Powder I. Effect of MMA/Xylene Contents on Surface Modification of UHMWPE (표면개질된 초고분자량 폴리에틸렌 분말의 표면과 화학적 특성 및 이를 함유하는 상온 경화용 폴리(메틸 메타크릴레이트) 뼈 시멘트의 기계적 특성 I. 메틸 메타크릴레이트/자일렌 함량에 따른 초고분자량 폴리에틸렌의 표면 개질 효과)

  • 양대혁;윤관희;김순희;이종문;강길선
    • Polymer(Korea)
    • /
    • v.28 no.1
    • /
    • pp.77-85
    • /
    • 2004
  • It has been widely used ultra high molecular weight polyethylene (UHMWPE) for the biomaterials due to its excellent mechanical properties and biocompatibility. In the case of blend of UHMPE with another polymeric biomaterials, however, UHMWPE might have low blend compatibility due to surface inertness. In this study, in order to improve the mechanical properties of poly(methyl methacrylate) (PMMA) bone cement by means of the impregnation of UHMWPE powder, we developed the novel surface modification method by the mixture of methyl methacrylate (MMA) and xylene. We investigated the variation of composition of MMA/xylene. It was confirmed by the analysis of Fourier transform infrared-attenuated total reflectance, scanning electron microscope, universal transverse mercator, and digital thermometer. The maximum mechanical strength of surface modified UHMWPE powder impregnated PMMA bone cement compound was observed the ratio of 1 : 1 (v/v%) MMA/xylene. Also its curing temperature decreased from 103 $^{\circ}C$ to 58 ∼ 73 $^{\circ}C$ The mechanism of surface modification of UHMWPE powder by the mixture of MMA/xylene has been proposed.

Characteristics of High Strength Polyethylene Tape Yarns and Their Composites by Solid State Processing Methods (고상공정법에 의한 고강도 폴리에틸렌 테이프사와 그 복합재료의 특성)

  • Lee, Seung-Goo;Cho, Whan;Joo, Yong-Rak;Song, Jae-Kyung;Joo, Chang-Whan
    • Composites Research
    • /
    • v.12 no.2
    • /
    • pp.91-100
    • /
    • 1999
  • The manufacture of high strength polyethylene(HSPE) tape yarns has been accomplished by a solid state processing(SSP) method as the compaction of ultra-high molecular weight polyethylene(UHMWPE) powders and drawing of the compacted film under the melting point without any organic solvents. In this study, the characteristics of HSPE tape yarns produced by SSP which is desirable for production cost and environmental aspect were analyzed. As the results, tensile strengths of HSPE tape yarns increased with increasing the draw ratio and the fracture morphology of highly drawn HSPE tape yarns showed more fibrillar shape than the low drawn one. Interfacial shear strengths of HSPE tape yarns with vinylester resin increased by $O_2$ plasma treatment and maximum interfacial shear strength was obtained in the plasma treatment condition of 100W and 5min. In addition, mechanical properties of HSPE tape yarn reinforced composites were investigated and compared with those of the gel spun HSPE fiber reinforced composites.

  • PDF

Fatigue Crack Propagation of Sliding Core in Artificial Intervertebral Disc due to the Fatigue Loading Mode (인공추간판의 피로하중 모드에 따른 슬라이딩 코어의 피로균열전파 거동)

  • Kim Cheol-Woong;Kang Bong-Su
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.367-368
    • /
    • 2006
  • Today, the Artificial Intervertebral Disc (AID) is being developed by increasing the oblique of the endplate gradually. In other words, Ultra-high Molecular Weight Polyethylene (UHMWPE) which is apply to the sliding core of the AID, does not change the shape but alters the oblique of endplate. However, the unreasonable increase of degree of freedom (DOF) can result in the aggravation of the bone fusion and the initial stability and it can also lead to the increase of the concentrated force in core. For these reasons, it is necessary to develop the advanced techniques, which choose the most adequate DOF. In this study, the new optimized modeling of the sliding core and the endplate, the fatigue characteristics, the crack propagation and the formation mechanism of wearing debris was studied and the minimizing technique will be derived from this research.

  • PDF

고체원소 이온주입 공정으로 제조된 NbN 박막의 내마모 특성 평가

  • Park, Won-Ung;Choe, Jin-Yeong;Jeon, Jun-Hong;Han, Seung-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.62-62
    • /
    • 2010
  • 인공관절은 노인성 질환이나 자가 면역질환, 신체적인 외상 등에 의한 관절의 손상 부위를 대체하기 위해 고안된 관절의 인공대용물로써 최근 인구의 고령화와 질병, 사고의 증가에 따라 그 수요가 급격히 증가하는 추세를 보이고 있다. 인공관절의 소재로는 현재 metal-on-polymer(MOP) 소재가 가장 많이 사용되고 있는데, metal 소재로서는 Co-Cr계 합금이, polymer 소재로서는 초고분자량 폴리에틸렌 (ultra high molecular weight polyethylene) 이 주로 사용되고 있다. MOP 소재의 경우 충격흡수의 장점이 있는 반면 wear debris에 의한 골용해로 인해 관절이 느슨해지는 문제점이 발생하여 재시술의 주요 원인이 되고 있다. 또한 metal 소재로 주로 사용되고 있는 Co-Cr계 합금의 경우 인공관절의 마모, 부식 현상에 의해 Co, Cr등이 체내에 용출되어 세포독성의 문제를 일으킬 수 있다는 단점을 가지고 있다. 본 연구에서는 고체원소 이온주입 기술을 이용하여 316L stainless steel 기판에 niobium을 이온 주입 한 후 niobium nitride (NbN) 박막을 증착하여 counterpart 소재인 초고분자량 폴리에틸렌(UHMWPE) 의 마모를 줄이는 실험을 진행하였다. Pin-on-disk tribometer를 통해 마모 테스트를 진행하여 NbN 박막의 내마모특성을 평가하였으며, 박막의 결정구조 및 화학적 특성을 평가하기 위해 XRD, AES 분석을 수행하였다. 또한 박막의 경도와 표면조도를 측정하기 위해 micro hardness tester, AFM을 이용하였다.

  • PDF

A Study on the Preparation of Battery Separator for Polyethylene/Potassium Hexatitanate Whisker (폴리에틸렌/육티탄산칼륨 휘스커 복합재료에 의한 축전지격리막의 제조에 관한 연구)

  • Lee, Wan-Jin;Ko, Man-Seok;Choi, Byung-Ryul;Cho, Il-Hoon
    • Applied Chemistry for Engineering
    • /
    • v.9 no.2
    • /
    • pp.193-199
    • /
    • 1998
  • The mixtures of ultra-high molecular weight polythylene (UHMWPE), high density polyethylene (HDPE), process oil (mineral oil) and potassium hexatitanate whisker were melted and mixed at $150^{\circ}C$ for 30min, and prepared by compression molding to the specimen of separator of about $200{\mu}m$ thickness at the same temperature and 5000 psi. Thereafter the pores were formed by extracting process oil with organic solvents. In this study, the range of PR (the ratio polymer to process oil) was varied from 0.1 to 0.5 because the specimen turned into rubbery phase at which PR was below 0.1 whereas it changed into gel phase at which PR was above 0.5. When the specimen was treated with nonpolar organic solvents, process oil was extracted nearly 98%. Tensile strength was $31kg/cm^2$ at PR = 0.426, and resistance of specimen was $37m{\Omega}/cm^2$ at PR = 0.186, and $53m{\Omega}/cm^2$ at PR = 0.426. The $N_2$ adsorption-desorption isotherm showed a hysteresis representing regions of capillary condensation, and the surface area at PR = 0.186 was relatively large as $130cm^2/g$. Potassium hexatitanate whisker was randomly dispersed in between PE layers. It might be that the whisker is intercalated through the PE thin layers oriented by compression.

  • PDF

Preconcentration and Speciation of Trace Mercury Compounds in Water Sample Using Dithizonates Extraction and Reverse Phase Liquid Chromatography (디티존 착물 추출과 역상 액체 크로마토그래피를 이용한 물시료 중의 미량 수은 화합물의 농축 및 화학종의 분리)

  • Suh, Jung-Ki;Cho, Kyung-Haeng;Lee, Sang-Haak
    • Analytical Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.81-88
    • /
    • 2000
  • A rapid preconcentration method was developed for the speciation of the trace mercury compounds in water sample. The mercury compounds were extracted and preconcentrated simply as their dithizone complexes by passing through the dithizone impregnated ultra-high molecular weight polyethylene (UHMWPE) membrane solvent inlet filter following sanification in methanol solvent. The concentrated dithizonates were separated by liquid chromatography on a $C_{18}$ column. Complete resolution was obtained between methyl-, ethyl-, phenyl-, and inorganic mercury with a mobile phase of 0.05 M acetate buffer (pH=4)/THF/methanol(3:5:2). The separnted mercury chelates were detected by spectrophotometrically at 475 nm. The proposed method was successfully applied to the speciation of mercury compounds in waste water with detection limit at the subnanogram/mL level.

  • PDF

Effect of the Radius of Curvature on the Contact Pressure Applied to the Endplate of the Sliding Core in an Artificial Intervertebral Disc (인공추간판 슬라이딩 코어의 곡률반경 변화가 종판의 접촉압력에 미치는 영향)

  • Kim, Cheol-Woong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.1
    • /
    • pp.29-35
    • /
    • 2012
  • The treatments for spinal canal stenosis are radicular cyst removal, spine fusion, and implantation of an artificial intervertebral disc. Artificial intervertebral discs have been most widely used since the mid-2000s. The study of artificial intervertebral discs has been focused on the analysis of the axial rotation, lateral bending, the degrees of freedom of the disc, and flexion-extension of the vertebral body. The issue of fatigue failure years after the surgery has arisen as a new problem. Hence, study of artificial intervertebral discs must be focused on the fatigue failure properties and increased durability of the sliding core. A finite element model based on an in the artificial intervertebral disc (SB Charit$\acute{e}$ III) was produced, and the influence of the radius of curvature and the change in the coefficient of friction of the sliding core on the von-Mises stress and contact pressure was evaluated. Based on the results, new artificial intervertebral disc models (Models-I, -II, and -III) were proposed, and the fatigue failure behavior of the sliding core after a certain period of time was compared with the results for SB Charit$\acute{e}$ III.