• Title/Summary/Keyword: ultimate strength of plates

Search Result 127, Processing Time 0.029 seconds

Assessment of the performance of composite steel shear walls with T-shaped stiffeners

  • Zarrintala, Hadi;Maleki, Ahmad;Yaghin, Mohammad Ali Lotfollahi
    • Earthquakes and Structures
    • /
    • v.23 no.3
    • /
    • pp.297-313
    • /
    • 2022
  • Composite steel plate shear wall (CSPSW) is a relatively novel structural system proposed to improve the performance of steel plate shear walls by adding one or two layers of concrete walls to the infill plate. In addition, the buckling of the infill steel plate has a significant negative effect on the shear strength and energy dissipation capacity of the overall systems. Accordingly, in this study, using the finite element (FE) method, the performance and behavior of composite steel shear walls using T-shaped stiffeners to prevent buckling of the infill steel plate and increase the capacity of CSPSW systems have been investigated. In this paper, after modeling composite steel plate shear walls with and without steel plates with finite element methods and calibration the models with experimental results, effects of parameters such as several stiffeners, vertical, horizontal, diagonal, and a combination of T-shaped stiffeners located in the composite wall have been investigated on the ultimate capacity, web-plate buckling, von-Mises stress, and failure modes. The results showed that the arrangement of stiffeners has no significant effect on the capacity and performance of the CSPSW so that the use of vertical or horizontal stiffeners did not have a significant effect on the capacity and performance of the CSPSW. On the other hand, the use of diagonal hardeners has potentially affected the performance of CSPSWs, increasing the capacity of steel shear walls by up to 25%.

Flexural strengthening of continuous unbonded post-tensioned concrete beams with end-anchored CFRP laminates

  • Ghasemi, Saeed;Maghsoudi, Ali A.;Bengar, Habib A.;Ronagh, Hamid R.
    • Structural Engineering and Mechanics
    • /
    • v.53 no.6
    • /
    • pp.1083-1104
    • /
    • 2015
  • This paper provides the results of an experimental investigation into the flexural behavior of continuous two-span unbonded post-tensioned high strength concrete (HSC) beams, strengthened by end-anchored CFRP laminates of different configurations in the hogging region. Implementing two different configurations of end-anchorage systems consisting of steel plates and bolts and carefully monitoring the development of strains throughout the load history using sufficiently large number of strain gauges, the response of beams including the observed crack propagations, beam deflection, modes of failure, capacity enhancement at service and ultimate and the amount of moment redistribution are measured, presented and discussed. The study is appropriate in the sense that it covers the more commonly occurring two span beams instead of the simply supported beams investigated by others. The experiments reconfirmed the finding of others that proper installation of composite strengthening system is most important in the quality of the bond which is essential for the internal transfer of forces. It was also found that for the tested two span continuous beams, the capacity enhancement is more pronounced at the serviceability level than the ultimate. This is an important finding as the design of these beams is mostly governed by the serviceability limit state signifying the appropriateness of the suggested strengthening method. The paper provides quantitative data on the amount of this capacity enhancement.

Stability condition for the evaluation of damage in three-point bending of a laminated composite

  • Allel, Mokaddem;Mohamed, Alami;Ahmed, Boutaous
    • Steel and Composite Structures
    • /
    • v.15 no.2
    • /
    • pp.203-220
    • /
    • 2013
  • The study of the tensile strength of composite materials is far more complex than analysis of the properties of elasticity and plasticity. Indeed, during mechanical loading, micro-cracks in the matrix, the fibers break, debonding of the interfaces are created. The failure process of composites is of great diversity and cannot be described if even we know: the strength criterion of each individual component, the state of stress and strain in the material, the propagation phenomena cracks in the structure and nature of the interface between the matrix and the reinforcement. This information is only partially known and the obtained by the analysis of a stress limit beyond which there is destruction of the material is almost impossible. To partially process the issue, a solution lies in a mesoscopic approach of seeking a law to locate the ultimate strength of the material for a plane stress state. Tests on rectangular plates in bending PEEK/APC2 and T300/914 three were made and this in order to validate our approach, the calculation has been implemented in a nonlinear finite element code (Castem 2000), in order to make comparison with the numerical results. The results show good agreement between numerical simulation and the two materials; however, it would be interesting to consider other phenomena in the criterion.

Elasto-plastic behaviour of perforated steel plates subjected to compression and bending

  • Maiorana, Emanuele;Pellegrino, Carlo;Modena, Claudio
    • Steel and Composite Structures
    • /
    • v.11 no.2
    • /
    • pp.131-147
    • /
    • 2011
  • The aim of this work is to provide some insights into the elasto-plastic behaviour of plate girder web square and rectangular panels with centred and eccentric holes under both compression and in-plane bending moment. The numerical study was validated comparing the numerical results obtained for one simple steel plate configuration with the corresponding experimental results, obtained at the University of Padova, observing the influence of the initial out-of-plane imperfections on the force vs. displacement relationship and ultimate strength. Once validated the numerical approach, the effect of bending moment on the stability of the plate is studied and some differences with respect to the uniform compression load case are shown. The influence of dimension and position of the hole, the plate aspect ratio and the steel grade on elasto-plastic behaviour is observed. Some indications regarding the critical slenderness (at which transition from elastic to plastic collapse occurs) are given for square and rectangular plates with symmetric and eccentric holes having small, medium and large diameter.

Experimental and numerical study of a steel plate-based damper for improving the behavior of concentrically braced frames

  • Denise-Penelope N. Kontoni;Ali Ghamari;Chanachai Thongchom
    • Steel and Composite Structures
    • /
    • v.47 no.2
    • /
    • pp.185-201
    • /
    • 2023
  • Despite the high lateral stiffness and strength of the Concentrically Braced Frame (CBF), due to the buckling of its diagonal members, it is not a suitable system in high seismic regions. Among the offered methods to overcome the shortcoming, utilizing a metallic damper is considered as an appropriate idea to enhance the behavior of Concentrically Braced Frames (CBFs). Therefore, in this paper, an innovative steel damper is proposed, which is investigated experimentally and numerically. Moreover, a parametrical study was carried out to evaluate the effect of the mechanism (shear, shear-flexural, and flexural) considering buckling mode (elastic, inelastic, and plastic) on the behavior of the damper. Besides, the necessary formulas based on the parametrical study were presented to predict the behavior of the damper that they showed good agreement with finite element (FE) results. Both experimental and numerical results confirmed that dampers with the shear mechanism in all buckling modes have a better performance than other dampers. Accordingly, the FE results indicated that the shear damper has greater ultimate strength than the flexural damper by 32%, 31%, and 56%, respectively, for plates with elastic, inelastic, and plastic buckling modes. Also, the shear damper has a greater stiffness than the flexural damper by 43%, 26%, and 53%, respectively, for dampers with elastic, inelastic, and plastic buckling modes.

Estimation of Buckling and Plastic Behaviour according to the Analysis Model of the Stiffened Plate (보강판의 해석모델에 따른 좌굴 및 소성거동 평가)

  • Ko, Jae-Yong;Oh, Young-Cheol;Park, Joo-Shin
    • Journal of Navigation and Port Research
    • /
    • v.31 no.3 s.119
    • /
    • pp.271-279
    • /
    • 2007
  • Ship structures are basically an assembly of plate elements and estimation load-carrying capacity or the ultimate strength is one of the most important criterion for estimated safety assessment and rational design on the ship structure. Also, Structural elements making up ship plated structures do not work separately against external load. One of the critical collapse events of a ship structure is the occurrence of overall buckling and plastic collapse of deck or bottom structure subjected to longitudinal bending. So, the deck and the bottom plates are reinforced by a number af longitudinal stiffeners to increase their strength and load-carrying capacity. For a rational design avoiding such a sudden collapse, it is very important to know the buckling and plastic behaviour or collapse pattern of the stiffened plate under axial compression. In this present study, to investigate effect af modeling range, the finite element method are used and their results are compared varying the analysis ranges. When making the FEA model, six types of structural modeling are adopted varying the cross section of stiffener. In the present paper, a series of FEM elastoplastic large deflection analyses is performed on a stiffened plate with fiat-bar, angle-bar and tee-bar stiffeners. When the applied axial loading, the influences of cross-sectional geometries on collapse behaviour are discussed. The purpose of the present study is examined to numerically calculate the characteristics of buckling and ultimate strength behavior according to the analysis method of ship's stiffened plate subject to axial loading.

A Study on Mechanical properties of Aluminized Steel Plate (熔融알루미늄 鍍金한 鋼板의 機械的 性質에 關한 硏究)

  • Kim, Suk-Yoon;Choi, Chong-Sool
    • Journal of the Korean institute of surface engineering
    • /
    • v.13 no.2
    • /
    • pp.81-86
    • /
    • 1980
  • The mechanical properties of aluminized steel were investigated after the JIS SB 41 plates were dipped in molten aluminum bath. (1) The growth rate of iron-aluminum alloy layer was fast in early stage of alumizing, and then gradually decreased with increasing time. However, over the time period above 10 minutes the growth of alloy layer did not occur. (2) The constituent of alloy layer formed on the steel surface was identified to be intermetallic compound of $Fe_2\;Al_5$. (3) The ultimate tensile strength and elongation of aluminized steel showed a nearly constant value over all thickness below about 0.15 mm. However, both properties decreased rapidly in showed a nearly constant value over all thickness above about 0.20 mm. (4) In case of aluminized steel with greater thickness, crack was formed below yield point of base metal, which is considered to be attributed to the alloy layer failure.

  • PDF

A Study on the Structural Performance of Retrofitted RC Shear Walls with An Opening (피해를 입은 전단벽의 보강 후 구조성능 평가)

  • Kim, Hyun-Min;Choi, Youn-Cheul;Choi, Chang-Sik;Lee, Li-Hyung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.05a
    • /
    • pp.234-237
    • /
    • 2006
  • A series of three shear wall specimens was tested under constant axial stress and reversed cyclic lateral loading in order to evaluate the seismic retrofit that had been proposed for the shear wall with the opening induced by remodeling. One of these specimens was tested in the as-built condition and the other two were retrofitted prior to testing. The retrofit involved the use of carbon fiber sheets and steel plates (thickness of 3mm) over the entire face of the wall. The test results show that the ultimate failure modes of the specimens were found to be shear fracture of the wall around the opening and two difference types of retrofitting strategy make the different effects of a rise in the strength of each specimen.

  • PDF

An experimental study on the unequal thickness joint using FSW with $4mm^{t}$ and $6mm^{t}$ Al 6061 T6 plates (Al 6061 T6 합금의 이두께 마찰교반 용접에 관한 연구)

  • Ryu, Deok-Hui;Kim, Jae-Seong;Jin, Hyeong-Guk;Lee, Jae-Hun;Lee, Bo-Yeong
    • Proceedings of the KWS Conference
    • /
    • 2005.06a
    • /
    • pp.223-225
    • /
    • 2005
  • In order to demonstrate the friction stir weldability of the Al 6061 T-6 unequal thickness joint and determine optimum welding parameters, the relations between welding parameters and properties of the joints have been studied in this paper. The experimental results showed that the tensile properties of the joints are affected by the welding heat inputs and tool shape. In this study, the maximum ultimate strength of the as-welded joint is equivalent to 78% and 18hour aged joint is equivalent to 93% that of the base metal. Though the voids-free joints are fractured at the thermally affected zone on the advancing side, the fracture occurs at the weld center when the void defects exist in the joints.

  • PDF

Analysis of composite girders with hybrid GFRP hat-shape sections and concrete slab

  • Alizadeh, Elham;Dehestani, Mehdi
    • Structural Engineering and Mechanics
    • /
    • v.54 no.6
    • /
    • pp.1135-1152
    • /
    • 2015
  • Most of current bridge decks are made of reinforced concrete and often deteriorate at a relatively rapid rate in operational environments. The quick deterioration of the deck often impacts other critical components of the bridge. Another disadvantage of the concrete deck is its high weight in long-span bridges. Therefore, it is essential to examine new materials and innovative designs using hybrid system consisting conventional materials such as concrete and steel with FRP plates which is also known as composite deck. Since these decks are relatively new, so it would be useful to evaluate their performances in more details. The present study is dedicated to Hat-Shape composite girder with concrete slab. The structural performance of girder was evaluated with nonlinear finite element method by using ABAQUS and numerical results have been compared with experimental results of other researches. After ensuring the validity of numerical modeling of composite deck, parametric studies have been conducted; such as investigating the effects of constituent properties by changing the compressive strength of concrete slab and Elasticity modulus of GFRP materials. The efficacy of the GFRP box girders has been studied by changing GFRP material to steel and aluminum. In addition, the effect of Cross-Sectional Configuration has been evaluated. It was found that the behavior of this type of composite girders can be studied with numerical methods without carrying out costly experiments. The material properties can be modified to improve ultimate load capacity of the composite girder. strength-to-weight ratio of the girder increased by changing the GFRP material to aluminum and ultimate load capacity enhanced by deformation of composite girder cross-section.