• 제목/요약/키워드: ultimate displacement

검색결과 337건 처리시간 0.03초

철도노반 긴급복구를 위한 토목섬유 컨테이너의 파괴형태 분석 (Analysis of Failure Mode of Geotextile Container for Urgent Rehabilitation of Railroad Bed)

  • 신은철;이명호;이준철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(I)
    • /
    • pp.608-613
    • /
    • 2002
  • This study was under taken as an analysis of failure mode in a railroad bed reconstructed with miniaturized Geotextile Container after being destroyed by heavy rain. It assesses the practical use of the bag shaped Geotextile Container method in the rehabilitation of destroyed roadbeds. The failure mode was assessed using the laboratory model tests to determine the following criteria: Strain of Geotextile Container, Vertical & Horizontal displacements of Geotextile Container layer, and the transmitting load effects due to the applied load. The Geotextile Container layer was failed as a Block Failure type, although there was some variation in the results between the saturated and unsaturated conditions. The main failure was caused by the reduction of the interface friction between Geotextile Containers. The result of this mobilizes the significant horizontal displacement and the ultimate failure of the Geotextile Container layer. The strain on the wet Geotextile Container was occurred about two times greater than that of dry condition.

  • PDF

유사동적실험에 의한 탄성패드 접합 H형 철골프레임공법으로 보강 된 기존 중·저층 R/C 골조의 내진성능 평가 (Seismic Capacity Evaluation of Existing Medium-and low-rise R/C Frame Retrofitted by H-section Steel Frame with Elastic Pad Based on Pseudo-dynamic testing)

  • 김진선;이강석
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권4호
    • /
    • pp.83-91
    • /
    • 2021
  • 본 연구에서는 기존 철근콘크리트 (R/C) 구조체와 내진보강 부재의 접합부의 성능을 향상시키기 위해서 접합부에 탄성패드를 가지는 새로운 H형강 철골프레임 내부접합형 내진보강공법 (H-section Steel Frame with Elastic Pad, HSFEP)을 제안하였다. HSFEP 시스템은 필요 내진보강량 산정이 간편한 내력향상형 보강공법으로서, 전단파괴가 발생할 가능성이 매우 높은 비내진상세를 가지는 중·저층 R/C 건축물에 적합한 공법이다. 본 연구에서 제안한 HSFEP 내진보강공법의 유용성을 검증하기 위하여 비내진상세를 가지는 국내 R/C 건축물을 바탕으로 실물 2층 골조 실험체를 제작하여 유사동적실험을 수행하여 최대지진응답 하중 및 변위, 지진피해정도를 중심으로 내진보강효과를 검토하였다. 실험결과 본 연구에서 개발한 HSFEP 내부접합형 내진보강법은 접합부성능이 개선되었으며, 효과적으로 수평극한내력을 증진시킴과 동시에 대지진 입력 시에도 지진응답변위를 매우 효과적으로 억제시켰다.

사질토에 근입된 헬릭스 피치에 따른 헬리컬 파일의 수치해석적 거동분석 (Analysis of Helical Pile Behavior in Sands Varying Helix Pitch Based on Numerical Analysis Results)

  • 박종호;이기철;최병현;김동욱
    • 한국지반신소재학회논문집
    • /
    • 제17권4호
    • /
    • pp.29-40
    • /
    • 2018
  • 캐나다 및 베네수엘라에 주로 분포하는 오일샌드는 원유들이 모래질 흙의 간극에 존재한다. 이러한 오일샌드로부터 원유를 따로 추출하기 위해서는 규모가 큰 플랜트를 건설해야 한다. 일반적으로 오일샌드 플랜트의 기초는 주로 항타말뚝 혹은 현장타설말뚝이 사용되고 있다. 하지만 주로 극지에 위치한 오일샌드는 얼어있는 지반과 표층의 유기토 때문에 항타말뚝의 시공 및 장비 진입에 어려움이 있으며, 현장타설말뚝의 경우 기온이 낮기 때문에 콘크리트 양생에 문제가 있다. 이번 연구의 주제인 헬리컬 파일은 크지 않은 연직력에 기초한 회전력을 중심으로 빠르고 간편하게 시공이 가능하다. 따라서, 접근성이 떨어지는 극지환경에서도 소형장비를 사용하여 간단한 시공이 가능하며, 헬리컬 파일의 두부에 역회전을 가해 말뚝기초의 인발 및 재사용 또한 용이하다. 이번 연구에서는 헬릭스 피치를 변화시켜 헬리컬 파일 및 헬릭스의 거동을 수치해석으로 분석하였다. 수치해석의 검증은 모형 헬리컬 파일의 실내모형실험 결과와 비교하여 수행하였으며, 헬릭스의 피치에 따른 헬리컬 파일의 극한하중, 헬리컬 파일의 축에 부착한 각 헬릭스의 변위, 하중분담률을 분석하였다.

모래지반에서 비배토 테이퍼말뚝의 연직거동 특성 (Axial Behavior of Non-Displacement Tapered Piles in Sand)

  • 백규호;이준환;김대홍
    • 한국지반공학회논문집
    • /
    • 제23권8호
    • /
    • pp.35-45
    • /
    • 2007
  • 말뚝의 거동특성은 지반조건 뿐만 아니라 말뚝의 형상에 의해서도 영향을 받는 것으로 알려져 있다. 본 논문에서는 비배토 테이퍼말뚝과 원통형말뚝의 연직거동과 지지력 특성을 조사하기 위해서 선단지지력과 주면마찰력을 분리해서 측정할 수 있는 모형말뚝과 가압토조를 이용해서 총 12회의 모형말뚝시험을 실시하였다. 시험결과 원통형말뚝의 주면 하중은 말뚝 직경의 4%에 해당하는 침하량에서 극한치에 도달하였다. 반면 테이퍼말뚝의 주면하중은 말뚝이 침하함에 따라 계속 증가하는 경향을 보였으며, 원통형말뚝의 주면하중보다 상당히 큰 것으로 나타났다. 그리고 조밀한 지반에서는 테이퍼말뚝의 전체지지력이 원통형말뚝보다 작은 반면 상대밀도가 보통인 지반에서는 테이퍼말뚝의 전체 지지력이 원통형말뚝보다 큰 것으로 나타났다. 테이퍼말뚝의 단위 극한선단지지력은 지반의 토압계수가 0.4보다 클 때 원통형말뚝보다 컸으며, 테이퍼말뚝의 단위 극한주면마찰력은 지반의 토압계수와는 무관하게 원통형말뚝보다 큰 것을 알 수 있었다.

Experimental study on shear capacity of SRC joints with different arrangement and sizes of cross-shaped steel in column

  • Wang, Qiuwei;Shi, Qingxuan;Tian, Hehe
    • Steel and Composite Structures
    • /
    • 제21권2호
    • /
    • pp.267-287
    • /
    • 2016
  • The seismic performance of the ordinary steel reinforced concrete (SRC) columns has no significant improvement compared to the reinforced concrete (RC) columns mainly because I, H or core cross-shaped steel cannot provide sufficient confinement for core concrete. Two improved SRC columns by constructing with new-type shaped steel were put forward on this background, and they were named as enlarging cross-shaped steel and diagonal cross-shaped steel for short. The seismic behavior and carrying capacity of new-type SRC columns have been researched theoretically and experimentally, while the shear behavior remains unclear when the new-type columns are joined onto SRC beams. This paper presents an experimental study to investigate the shear capacity of new-type SRC joints. For this purpose, four new-type and one ordinary SRC joints under low reversed cyclic loading were tested, and the failure patterns, load-displacement hysteretic curves, joint shear deformation and steel strain were also observed. The ultimate shear force of joint specimens was calculated according to the beam-end counterforce, and effects of steel shape, load angel and structural measures on shear capacity of joints were analyzed. The test results indicate that: (1) the new-type SRC joints display shear failure pattern and has higher shear capacity than the ordinary one; (2) the oblique specimens have good bearing capacity if designed reasonably; and (3) the two proposed construction measures have little effect on the shear capacity of SRC joints embedded with diagonal cross-shaped steel. Based on the mechanism observed from the test, the formulas for calculating ultimate shear capacity considering the main factors (steel web, stirrup and axial compression ratio) were derived, and the calculated results agreed well with the experimental and simulated data.

성토지반에 타입된 H형강 말뚝의 지지거동 (Bearing Capacity of Driven H-Piles in Embankment)

  • 박영호;정경자;김성환;유성근;이재혁;박종면
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.173-182
    • /
    • 2000
  • To find axial and lateral responses of impact-driven H piles in embankment(SM), the H piles are instrumented with electric strain gages, dynamic load test is performed during driving, and then the damage of strain gages is checked simultaneously. Axially and laterally static load tests are performed on the same piles after one to nine days as well. Then load-settlement behavior is measured. Furthermore, to find the set-up effect in H pile, No. 4, 16, 26, and R6 piles are restriked about 1, 2, and 14 days after driving. As results, ram height and pile capacity obtained from impact driving control method become 80cm and 210.3∼242.3ton, respectively. At 15 days after driving, allowable bearing capacity by CAPWAP analysis, which 2.5 of the factor of safety is applied for ultimate bearing capacity, increases 10.8%. Ultimate bearing capacity obtained from axially static load test is 306∼338ton. This capacity is 68.5∼75.7% at yield force of pile material and is 4∼4.5 times of design load. Allowable bearing capacity using 2 of the factor of safety is 153∼169ton. Initial stiffness response of the pile is 27.5ton/mm. As the lateral load increases, the horizontal load-settlement behaves linearly to which the lateral load reaches up to 17ton. This reason is filled with sand in the cavity formed between flange and web during pile driving. As the result of reading with electric strain gages, flange material of pile is yielded at 19ton in horizontal load. Thus allowable load of this pile material is 9.5ton when the factor of safety is 2.0. Allowable lateral displacement of this pile corresponding to this load is 23∼36mm in embankment.

  • PDF

수직하중을 받는 모형 강널말뚝의 거동 (Behavior of Model Sheet Piles under Vertical Loads)

  • 윤여원;김두균
    • 한국지반공학회지:지반
    • /
    • 제14권6호
    • /
    • pp.5-16
    • /
    • 1998
  • 모래지반에서 모형강널말뚝의 수직하중에 대한 거동을 알아보기 위하여 말뚝단면적이 동일하고 플랜지의 개구정도가 각기 다른 5개의 모형말뚝을 제작하였으며, 각 말뚝에 대해 상대밀도, 하중작용방향(압축, 인발)을 달리하여 토조내에서 실내 모형말뚝시험을 수행하였다. 동일한 말뚝에 대해 인발하중을 받는 경우보다 압축하중을 받는 경우가 극한지지력에 있어 100%가량 크며, 상대밀도가 조밀할수록 그 차이는 더욱 증가하였다. 인발재하시험에서 극한지지력과 극한상태의 침하량은 상대밀도가 증가함에 따라 증가하였으며, 동일한 지반조건하에서 개구정도의 변화에 따른 극한지지력과 침하량은 일정한 범위내에 존재하였다. 압축하중조건하에서 극한지지력은 개구정도가 30$^{\circ}$이내에 있을 경우 가장 크게 나타났으며, 상대밀도가 커질수록 이러한 경향이 뚜렷하게 나타났다. 단면의 변화에 따른 극한하중 변화는 하중분포의 해석결과 부분폐색효과에 기인된 것으로 생각된다.

  • PDF

파이프형 앵커의 인발거동에 대한 연구 (Study on Pullout Behavior of Pipe Anchor)

  • 배우석;이봉직;권영철;이준대
    • 한국지반환경공학회 논문집
    • /
    • 제9권1호
    • /
    • pp.5-10
    • /
    • 2008
  • 본 연구에서는 표면거칠기와 근입비, 직경에 따른 파이프형 앵커의 인발거동을 평가하기 위하여 실내모형실험이 시행되었다. 수직방향의 지반 변형에서 매입된 파이프형 앵커의 설계는 파이프에 부과된 힘의 크기에 의해 지배받는다. 본 논문에서는 모형실험의 분석을 통하여 파이프 직경과 표면 거칠기, 근입비와 지반상태로 야기된 파이프형 앵커의 변위 특성과 극한 저항력을 비교하고 평가하였다. 실험결과는 상대밀도의 증가에 따라 극한 인발력이 20%가량 증가하고 있음을 보여주고 있다. 지반의 상대밀도와 파이프의 지름, 표면거칠기의 변화에 따른 파이프형 앵커의 파괴시 변위는 근입비가 2에서 8로 증가함에 따라 약 5배 정도의 증가 경향을 보였다. 또한 앵커이론에 근거한 이론식들은 인발계수를 과대평가하는 것으로 나타났다.

  • PDF

원심모형 실험을 이용한 지반-말뚝 상호작용의 정적 및 동적 거동 평가 (Comparison of Lateral Pile Behavior under Static and Dynamic Loading by Centrifuge Tests)

  • 유민택;권선용
    • 한국지반공학회논문집
    • /
    • 제34권7호
    • /
    • pp.51-58
    • /
    • 2018
  • 본 연구에서는 하중 조건에 따른 지반-말뚝 상호작용 시스템의 거동 차이를 분석하기 위해 일련의 원심모형 실험을 수행하였다. 정적 하중 조건의 경우, 말뚝 직경의 50% 수준까지 변위제어를 통해 하중을 재하하였으며, 지진 하중 조건의 경우 0.1g~0.4g 수준으로 1Hz 정현파를 가진하였다. 실험 결과로부터 얻은 정적 및 동적 p-y 곡선을 API p-y 곡선과 비교한 결과, API p-y 곡선과 정적 하중조건에서의 실험 p-y 곡선은 최대 지반반력 값이 20% 이내의 오차를 보인 반면, 동적 하중 조건에서의 실험 p-y 곡선과는 최대 지반반력 값이 5배 이상 차이가 발생하였다. 이는 등가정적 해석에서 기존 API p-y 곡선을 적용할 경우 비선형 영역에서 지반 반력을 크게 과소평가하며 보수적 설계를 야기할 수 있음을 의미한다.

Scale model experimental of a prestressed concrete wind turbine tower

  • Ma, Hongwang;Zhang, Dongdong;Ma, Ze;Ma, Qi
    • Wind and Structures
    • /
    • 제21권3호
    • /
    • pp.353-367
    • /
    • 2015
  • As concrete wind-turbine towers are increasingly being used in wind-farm construction, there is a growing need to understand the behavior of concrete wind-turbine towers. In particular, experimental evaluations of concrete wind-turbine towers are necessary to demonstrate the dynamic characteristics and load-carrying capacity of such towers. This paper describes a model test of a prestressed concrete wind-turbine tower that examines the dynamic characteristics and load-carrying performance of the tower. Additionally, a numerical model is presented and used to verify the design approach. The test results indicate that the first natural frequency of the prestressed concrete wind turbine tower is 0.395 Hz which lies between frequencies 1P and 3P (0.25-0.51 Hz). The damper ratio is 3.3%. The maximum concrete compression stresses are less than the concrete design compression strength, the maximum tensile stresses are less than zero and the prestressed strand stresses are less than the design strength under both the serviceability and ultimate limit state loads. The maximum displacement of the tower top are 331 mm and 648 mm for the serviceability limit state and ultimate limit state, respectively, which is less than L/100 = 1000 mm. Compared with traditional tall wind-turbine steel towers, the prestressed concrete tower has better material damping properties, potential lower maintenance cost, and lower construction costs. Thus, the prestressed concrete wind-turbine tower could be an innovative engineering solution for multi-megawatt wind turbine towers, in particular those that are taller than 100 m.