• Title/Summary/Keyword: u-Safety

Search Result 1,348, Processing Time 0.028 seconds

A Study on the Improvement Measures for Training of Special Security Guard (특수경비원 교육훈련의 개선방안에 관한 연구)

  • Choi, Eun-Ha;Yoo, Young-Jae;Lee, Sang-Bin
    • Korean Security Journal
    • /
    • no.16
    • /
    • pp.357-371
    • /
    • 2008
  • Currently, the security operations in nation's key foundations in Korea are performed by private police and special security guard in accordance with the Private Police Act and Security Business Act, respectively. In 1960s, The Korean Government introduced the private police system in terms of the national security issues, but it was just a hurriedly-set plan on the basis of Japanese Sunsa system as by that time there was no such system revitalized. However, the special security guards could offer wider range of security services including those of the private police with the enactment and revision of the Security Business Act 1976 and April 2001, respectively. Moreover, the expectations and interests rose over the special security guards in nation's key foundations after 9.11Terror Event in the U. S. 2001. However, as we investigated the current education/training system for the special security guard, we found that such education/training which is not activating the specialty of special security guard will not respond to the social demands. Special security guard owns its own characteristics other than those of general security guard as they are in service in nation's key foundations. Thus, the effcient management and training for the special security guard is the most important matter for the safety and security of nation's key foundations. Therefore, the well-educated special security guard through the reorganized and specialized education/training for the protection of nation's key foundations is expected to offer qualitatively improved security services.

  • PDF

Pretreatment Effect on the Analysis of Insoluble Hexavalent Chromium (전처리방법에 따른 불용성 6가 크롬 분석에 관한 연구)

  • Lee, Eun Jung;Roh, Jae Hoon;Won, Jong Uk;Chun, Mi Ryonng;Cho, Myung Hwa;Kim, Chi Nyon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.2
    • /
    • pp.292-300
    • /
    • 1996
  • Hexavalent chromium($Cr^{+6}$) compounds are considered to be particularly hazardous, primarily because of the associated risk of allergic reaction and cancer. The analytic method of hexavalent chromium such as the s-diphenylcarba-zide(DPC) method and all ether previously used methods are often made uncertain due to significant interferences from organic components. This report can provide a technique for the more rapid and simple determination of total hexavalent chromium. than other currently using methods. The s-diphenylcarbazide method proposed by the U.S. National Institute for Occupational Safety and Health has low recovery rate(15.67 - 48.20%) due to interference, iron chloride and nickel chloride. A microwave oven technique has high recovery rate(about 70%) of insoluble hexavalent chromium. For the difference of ionic charges of $Cr^{+3}$-ethylenediamine tetraacetic acid(EDTA) chelate and $CrO_4{^{-2}}$, we could detect them simultaneously by ion exchanged high performance liquid chromatography. The confirmation of $Cr^{+3}$ and $Cr^{+6}$ were checked by fraction collector and flameless atomic absorption spectrometer. We observed that the small amount of hexavalent chromium is converted to trivalent chromium due to enhancement of chromium reduction by $Fe^{+3}$ or $Ni^{+2}$. As a result of this study, on the analysis of insoluble hexavalent chromium with microwave oven was used for, it may be better and more precise analysis after pretreatment by 2% NaOH-3% $Na_2CO_3$ and then analysis UV-spectrophotometer. It should be done for various studies on insoluble hexavalent chromium on the basis work environmental monitoring so called welding, painting etc.

  • PDF

Study of Quantitative Assessment Standard for Type 1 and Type 2 Gas Cylinders Using Acoustic Emission Testing (음향방출법을 이용한 Type 1 및 Type 2 가스실린더의 정량적 평가기준에 대한 연구)

  • Kim, Dong-Hyun;Lee, Sang-Bum;Kim, Kyung-Hoon;Yoon, Dong-Jin;Bae, Dong-Myung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.2
    • /
    • pp.176-183
    • /
    • 2014
  • Acoustic emission testing (AET) of cylinders is advantageous in that it can be directly conducted on cylinders installed in a car, without needing to dissemble them on a real-time basis. Therefore, users prefer AET over other nondestructive testing methods. Owing to these advantages of AET, it has been approved by the Department of Transportation of the U.S. as a safety evaluation method for pressure containers or as an alternative to the hydroproof testing method. This paper presents a study of the quantitative evaluation criteria for a container having ultrasonic testing defects and also for Type 1 and Type 2 gas cylinders, which are defective seamless pressure containers provided by NK, a manufacturer of pressure containers. For the Type 1 cylinder, the process from crack growth to leak was observed in a repetitive fatigue test using a 113 L container according to ASTM E 1419-02. Further, for the Type 2 cylinder, integrity was evaluated using a 119 L sound container and a container damaged by hydraulic pressure, by the slow-fill method according to ASTM E 2191-02. Based on the AET results of the Type 1 and Type 2 cylinders, quantitative evaluation criteria were established for a defective and non-defective container.

Comparison of the Effects of Topical Nasal Application on Allergic Rhinitis between Korean and Western Medicine : A Systematic Review of Randomized Controlled Trials (알레르기성 비염에 대한 한약 및 양약 국소비강외용제의 효과 비교 : 체계적 문헌 고찰)

  • Jo, Hyo-Rim;Oh, Se-Hee;Kim, Seon-Hye;Sung, Won-Suk;Hong, Seung-Ug;Kim, Eun-Jung
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.32 no.4
    • /
    • pp.62-89
    • /
    • 2019
  • Objectives : The purpose of this study is to evaluate the effectiveness and safety of topical nasal application of Herbal medicine compared with Western medicine in the treatment of Allergic Rhinitis(AR). Methods : Electronic databases including Cochrane library, PubMed, EMBASE, CNKI, KMBASE, KISS, NDSL, OASIS, KISS and KJTK(Korean Traditional Knowledge Portal) were searched by the keywords such as 'allergic rhinitis', 'nasal sprays', 'herbal medicine', 'plant extracts', and 'external application'. The quality of each RCTs was assessed by Cochrane Collaboration of 'Risk of bias(RoB) Tool'. Results : 19 RCTs were finally selected from 1419 references screened. 19 RCTs were compared with the effects of topical nasal application of Herbal medicine and Western medicine. Based on the symptom scores from 13 RCTs, topical nasal application of herbal medicine generally has a better effect on relief of AR. The two treatments have similar effects on improving the level of specific factors like IgE, IgG, IL-13, $uLTD_4$ in blood and urine. 8 RCTs showed adverse effects(AEs) in both groups and severe AEs were not reported. Conclusions : This study shows that topical nasal application of herbal medicine can improve symptoms and related factors of allergic rhinitis. Well-designed RCT studies with low risk of bias should be conducted to confirm these findings.

Understanding of a Korean Standard for the Analysis of Hexavalent Chromium in Soils and Interpretation of their Results (토양오염공정시험기준 6가크롬 분석의 이해와 결과 해석)

  • Kim, Rog-Young;Jung, Goo-Bok;Sung, Jwa-Kyung;Lee, Ju-Young;Jang, Byoung-Choon;Yun, Hong-Bae;Lee, Yee-Jin;Song, You-Seong;Kim, Won-Il;Lee, Jong-Sik;Ha, Sang-Keun
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.5
    • /
    • pp.727-733
    • /
    • 2011
  • A new Korean standard for the determination of Cr(VI) in soils has been officially published as ES 07408.1 in 2009. This analytical method is based on the hot alkaline digestion and colorimetric detection prescribed by U.S. EPA method 3060A and 7196A. The hot alkaline digestion accomplished using 0.28 M $Na_2CO_3$ and 0.5 M NaOH solution (pH 13.4) at $90{\sim}95^{\circ}C$ determines total Cr(VI) in soils extracting all forms of Cr(VI), including water-soluble, adsorbed, precipitated, and mineral-bound chromates. This aggressive alkaline digestion, however, proved to be problematic for certain soils which contain large amounts of soluble humic substances or active manganese oxides. Cr(III) could be oxidized to Cr(VI) by manganese oxides during the strong alkaline extraction, resulting in overestimation (positive error) of Cr(VI). In contrast, Cr(VI) reduction by dissolved humic matter or Fe(II) could occur during the neutralization and acidic colorimetric detection procedure, resulting in underestimation (negative error) of Cr(VI). Futhermore, dissolved humic matter hampered the colorimetric detection of Cr(VI) using UV/Vis spectrophotometer due to the strong coloration of the filtrate, resulting in overestimation (positive error) of Cr(VI). Without understanding the mechanisms of Cr(VI) and Cr(III) transformation during the analysis it could be difficult to operate the experiment in laboratory and to evaluate the Cr(VI) results. For this reason, in this paper we described the theoretical principles and limitations of Cr(VI) analysis and provided useful guidelines for laboratory work and Cr(VI) data analysis.

Design and development of clear aligner management system using QR code (QR 코드를 활용한 투명 교정장치 관리 시스템 설계 및 개발)

  • Jang, Jin-Su;Son, Ho-Jung;Sim, Ji-Young;Kang, Sin-Yeong;Moon, Jun-Mo;Lee, Tae-Ro
    • Journal of Digital Convergence
    • /
    • v.17 no.9
    • /
    • pp.185-192
    • /
    • 2019
  • The introduction of smart technology provides accuracy, safety, and efficiency to both physicians and patients. Although interest in a clear aligner is increasing among users worldwide, the current clear aligner requires a visit to the hospital every one or two weeks for replacement, which is a very cumbersome process. There is also confusion among dentists and patients because about 40 to 80 devices are made, and calibration is done based on the order and duration of the clear aligner. Therefore, this study designed and developed a clear aligner management system so that communication between the patient and dentist can be smoothly performed by inserting the QR code into the transparent correction device. As a result, the size of the QR code was recognized as $6{\ast}6mm^2$ which can be used in the oral and the recognition distance was 100% within 12 cm. Since the dentist can remotely manage the patient with the proposed system and improve the correction effect, it is possible to manage patients abroad, as well as domestically.

A Comparison Study of College Student Pilots' Learning Styles in Flight Training School: applying Kolb's Learning Style Model (국내·외 학생조종사들의 비행훈련 학습양식 비교 연구: Kolb 학습양식 모델을 적용하여)

  • Hwang, Jae-Kab;Lee, Gun-Young;Yoon, Han-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.1
    • /
    • pp.197-207
    • /
    • 2021
  • According to the analysis of Kolb's learning style, Korean university student pilots interpret and attach meaning to themselves. Moreover, as the school year progresses, they enter the flight-training course with a 100 % diverger style, which is a variety of thoughts and imaginative learning styles. As the school year progresses, some changes occur with accommodator (11.1%) and assimilator (15.9%) styles. On the other hand, most students remain as the diverger style (71.4%). In the case of U.S. student pilots, most in first-year are assimilator (35.5%) and converger (24.3%) styles, and the proportion of the converger style increases as the senior year is approached. In the first grade, most Chinese student pilots are assimilators (41.5%) and convergers (28.4%), but in the higher grade, the proportion of assimilators and convergers decrease, and the proportion of diverger styles increases dramatically. In the fourth grade, the accommodator was similar to the first grade, but the converger style continued to decrease (41.5% in the first grade and 27.0% in the fourth grade).

A Study on Health Risk Assessment by Exposure to Organic Compounds in University Laboratory (대학 실험실에서의 유기화합물 노출에 의한 건강위험성 평가에 관한 연구)

  • Sim, Sanghyo;Won, Jung-II;Jeon, Hasub;Kim, Dowon
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.22 no.4
    • /
    • pp.49-60
    • /
    • 2021
  • Objectives: Laboratories have various latent physical, chemical, biological, and ergonomical factors according to the diversification and fusion of research and development activities. This study aims to investigate the chemical exposure concentrations of college laboratories and evaluate their health risks, and use them as basic data to promote the health of college students. Methods: The sampling and analysis of harmful chemicals in the air in laboratories were performed using Method 1500 of the U.S. National Institute for Occupational Safety and Health (NIOSH)의 Method 1500. The harmful chemicals in the laboratories were divided into carcinogenic and non-carcinogenic chemicals. Risk assessment was performed using the cancer risk (CR) for carcinogenic chemicals and using the hazard index (HI) for non-carcinogenic chemicals. Results: The harmful chemicals in college laboratories consisted of acetone, diethyl ether, methylene chloride, n-hexane, ethyl acetate, chloroform, tetrahydrofuran, toluene, and xylenes. They showed the highest concentrations in laboratories A (acetone 0.001~2.34ppm), B (chloroform 0.95~6.35ppm), C (diethyl ether 0.08~8.68ppm), and D (acetone 0.07~14.96ppm). The risk assessment result for non-carcinogenic chemicals showed that the HI of methylene chloride was 2.052 for men and 2.333 for women, the HI of N-hexane was 4.442 for men and 5.05 for women. Thus, the HI values were higher than 1. The risk of carcinogenic chemicals is determined by an excess cancer risk (ECR) value of 1.0×10-5, which means that one in 100,000 people has a cancer risk. The ECRs of chloroform exceeded 1.0×10-5 for both men and women, indicating the possibility of cancer risk. Conclusion: College laboratories showed the possibility of non-carcinogenic health risks for methylene chloride, n-hexane, tetrahydrofuran (THF), toluene, and xylenes, and carcinogenic health risks for chloroform, methylene chloride. However, this study used the maximum values of measurements to determine the worst case, and assumed that the subjects were exposed to the corresponding concentrations continuously for 8 hours per day for 300 days per year. In consideration of the nature of laboratory environment in which people are intermittently exposed, rather than continuously, to the chemicals, the results of this study has an element of overestimation.

Does dexmedetomidine combined with levobupivacaine in inferior alveolar nerve blocks among patients undergoing impacted third molar surgery control postoperative morbidity?

  • Patil, Shweta Murlidhar;Jadhav, Anendd;Bhola, Nitin;Hingnikar, Pawan;Kshirsagar, Krutarth;Patil, Dipali
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.2
    • /
    • pp.145-153
    • /
    • 2022
  • Background: Postoperative analgesia (POA) is an important determinant of successful treatment. Dexmedetomidine (DEX) has recently gained attention as a promising adjuvant to local anesthetics (LA). The present study aimed to evaluate the efficacy and safety of levobupivacaine (LB) as an adjuvant during inferior alveolar nerve block (IANB) in the extraction of lower impacted third molars (LITM). Methods: A prospective, randomized, placebo-controlled, triple-blind, parallel-arm, and clinical study was performed on 50 systemically healthy participants who required removal of an asymptomatic LITM. Using a 1:1 distribution, the participants were randomized into two groups (n = 25). Group L (control group) received 1.8 mL of 0.5% LB and 0.2 mL normal saline (placebo) and Group D (study group) received a blend of 1.8 mL of 0.5% LB and 0.2 mL (20 ㎍) DEX. The primary outcome variable was the duration of POA and hemodynamic stability, and the secondary variable was the total number of analgesics required postoperatively for up to 72 h. The participants were requested to record the time of rescue analgesic use and the total number of rescue analgesics taken. The area under the curve was plotted for the total number of analgesics administered. The pain was evaluated using the visual analog scale. Data analysis was performed using paired students and unpaired t-test, Mann-Whitney U test, Chi-square test, and receiver operating characteristic analysis. Statistical significance was set at P < 0.05. Results: The latency, profoundness of anesthesia, and duration of POA were statistically significant (P < 0.05). The differences between mean pain scores at 6, 12, 24, 48, and 72 h were found to be significant (each P = 0.0001). Fewer analgesics were required by participants in group D (2.12 ± 0.33) than in L (4.04 ± 0.67), with a significant difference (P = 0.0001). Conclusion: Perineurally administered LA with DEX is a safe, effective, and therapeutic approach for improving latency, providing profound POA, and reducing the need for postoperative analgesia.

The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy (저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향)

  • Park, Young-Sang;Son, ByeongJin;Son, Jaebum;Lee, Hoyul;Jeong, Yoosoo;Song, Chanho;Jung, Euisung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.259-267
    • /
    • 2021
  • Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.