• Title/Summary/Keyword: u-Health system

Search Result 526, Processing Time 0.025 seconds

The engineering merit of the "Effective Period" of bilinear isolation systems

  • Makris, Nicos;Kampas, Georgios
    • Earthquakes and Structures
    • /
    • v.4 no.4
    • /
    • pp.397-428
    • /
    • 2013
  • This paper examines whether the "effective period" of bilinear isolation systems, as defined invariably in most current design codes, expresses in reality the period of vibration that appears in the horizontal axis of the design response spectrum. Starting with the free vibration response, the study proceeds with a comprehensive parametric analysis of the forced vibration response of a wide collection of bilinear isolation systems subjected to pulse and seismic excitations. The study employs Fourier and Wavelet analysis together with a powerful time domain identification method for linear systems known as the Prediction Error Method. When the response history of the bilinear system exhibits a coherent oscillatory trace with a narrow frequency band as in the case of free vibration or forced vibration response from most pulselike excitations, the paper shows that the "effective period" = $T_{eff}$ of the bilinear isolation system is a dependable estimate of its vibration period; nevertheless, the period associated with the second slope of the bilinear system = $T_2$ is an even better approximation regardless the value of the dimensionless strength,$Q/(K_2u_y)=1/{\alpha}-1$, of the system. As the frequency content of the excitation widens and the intensity of the acceleration response history fluctuates more randomly, the paper reveals that the computed vibration period of the systems exhibits appreciably scattering from the computed mean value. This suggests that for several earthquake excitations the mild nonlinearities of the bilinear isolation system dominate the response and the expectation of the design codes to identify a "linear" vibration period has a marginal engineering merit.

The Study on Impact of Introduction Characteristics Factor of EMR System on Perceived Usefulness and Ease of Use and Behavioral Intention to Use (EMR시스템의 도입 특성요인이 지각된 유용성, 편이성 및 사용의도에 미치는 영향에 관한 연구)

  • Im, Hyung-Joo;Shim, Jeong-Taek;Lee, Sang-Shik
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.2
    • /
    • pp.32-50
    • /
    • 2009
  • Since 1990 when order communication system(OCS) was first introduced, the use of information technology in medical service has been widely accepted in order to enhance quality and customer relationship as well as to increase managerial efficiency. Medical information system is rapidly increasing and is trying to make ubiquitous healthcare environment through telemedicine system. Especially, medical profession and government have taken interest in electronic medical record (EMR) system which can digitalize and manage all medical records in hospitals. By recording patient's medical information in real time, EMR system can improve service efficiency and customer service quality including short waiting time, various utilization of clinic information, and reduced cost.

Critical Pathway Development for the Hysterectomy Patients and its applied Effect (자궁적출술 환자를 위한 critical pathway 개발과 적용효과)

  • Noh, Gi-Ok;Park, Kyung-Sook
    • Women's Health Nursing
    • /
    • v.6 no.2
    • /
    • pp.234-257
    • /
    • 2000
  • At present in the medical care, the study and effort for producing health service to consider efficiency, effectiveness, and quality are urgently called for because of the difficulty in the keen competition according to the inter- nationalization and opening, the operation in the medical institution service testing system, the change in the medical policy of KDRGs, and the lack of the health care cost increasing rate. As an alternative, the case management for the new management system is introduced in the U.S., and the Critical Pathway that is the method designing the contents of activity and its result has been developed and applied in order to anticipate and manage the patient-outcome for the realization of the cost-effective case-management. Thus, this study intended to analyze the effectiveness to obtain by developing the Critical Pathway presented as the method to improve the quality-betterment and cost effectiveness through the continuous and consistent patient management for the hysterectomy patient and applying it to the real practice. As a study method, this author formed a conceptual framework through considering five Critical Pathway used in the current U.S. and three Critical Pathway presented in the literature to develop the Critical Pathway for the hysterectomy patient, and made out the preliminary Critical Pathway through reviewing the old chart. This author made the verified the validity of the expert group about the developed Critical Pathway, and to confirm the possibility of practice application, completed and settled the final Critical Pathway after using the Critical Pathway to the hysterectomy patient from March 1st to 15th, 1997. Finally, to analyze the application-effect of the developed Critical Pathway, this author offered health care service applying the Critical Pathway to the hysterectomy patient from April 15th to August 31th, 1997. The guide for the Critical Pathway was carried out in advance by outpatient setting nurse for outpatient setting visit before the operation, and after hospitalization the primary nurse monitored the execution degree on the every duty. After discharge this author surveyed the complication through phone visiting, and one month after discharge surveyed the patient's reaction about the offered service when outpatient setting visit and analyzed the result. The source for health care cost was obtained by the statistics about the hospital charge which was offered by the General Business Department. The results were as follows. 1. It was decided that the vertical line of the Critical Pathway was made up of eight items such as monitoring/assessment, treatment, line/drains, activity, medication, lab test, diet, patient teaching, and the horizontal line of the Critical Pathway was made up of from hospitalization to discharge. 2. After the analysis of service contents through reviewing the old chart, it was decided that the horizontal line of the preliminary Critical Pathway was made up of from hopitalization to fourth postoperative day, and the vertical line of it was divided into eight items which were the contents to occur with the time frame of the horizontal line. 3. After the verifying the validity of the expert group about the preliminary Critical Pathway, the horizontal line was amended from hopitalization to third postoperative day, and taking their consensus, some contents of the horizontal line was amended and deleted. 4. From March 1st to 15th, 1997, to confirm the clinical suitability, this author offered eight hysterectomy patients the medical service through the Critical Pathway. The result was that three of them could be discharged at the expected discharge day, and the others later than that day. Supplementing the preliminary Critical Pathway through analyzing the cause of that delay- case, this author developed the final Critical Pathway. 5. There were no significant differences between the experimental and the control group in the incidence of complication(P > 0.05). 6. The 92.4% of experimental group was satisfied with the Critical Pathway service. 7. The length of hospital stay of the experimental group offered with the Critical Pathway service was 4.6 days and there was a significant difference that it was 1.3 days shorter than that of the control group(t=-29.514, P=0.000). 8. There wsa a significant difference that the mean medical charge per one patient of the experimental group offered the Critical Pathway service was cheaper \124,150 than that of the control group(t=-9.826, P=0.000). 9. The result that the author assumed and analyzed hospital income with the rate of turning bed was assumed that the increase of hospital income was \63,245,072 for that study, and the income increase was expected with \68,704,864 for a year. The result that this author applied the Critical Pathway to the hysterectomy patient have no differences in the incidence of complication, high satisfaction with that service, and the length of hospital stay decreased in the experimental group, and the mean hospital charge per one patient decreased, but hospital income increased. Suggestions for further study and nursing practice are as follows. 1. The study to apply the Critical Pathway for a year, verify the validity, and measure the effect repeatedly is needed. 2. To apply and manage the Critical Pathway effectively, the study to computerize it is needed. 3. The study to develop hospital-based Critical Pathway about other diseases or procedure, and measure the effect is needed.

  • PDF

Preliminary Design of PNUSAT-1 Cubesat for Vessel Monitoring (선박 모니터링을 위한 PNUSAT-1 큐브위성 시스템 예비 설계)

  • Kim, Haelee;Cho, Dong-hyun;Lee, Sanghoon;Park, Chanhwi;Lim, Ha Kyeong;Kim, Geonwoo;Kwak, Minwoo;Lee, Changhyun;Kim, Shinhyung;Koo, Inhoi;Lee, Daewoo
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.50 no.2
    • /
    • pp.137-146
    • /
    • 2022
  • AIS(Automatic Identification System) is a device that automatically transmits and receives ship information and is mounted on the ship. AIS information of ships near the coast can be received on the ground, but when going out to sea more than 50 nautical miles, communication with the ground is cut off. To solve this problem, ship information can be transmitted to the ground through an AIS satellite equipped with an AIS receiver. There is no case of AIS satellite development in Korea yet, and many domestic shipping companies are using overseas AIS services. PNUSAT-1 is a 1U+ CubeSat, developed by Pusan National University, and it is equipped with an AIS receiver for monitoring of ships and transmitting ship information to the ground. Since the mission data of PNUSAT-1 is in text format, the data size is not large. In consideration of this, communication equipment, low-precision sensors, and actuators were selected. In this paper, system preliminary design of PNUSAT-1 was performed, requirements for mission performance, operation scenario and mode design, hardware and software selection, and preliminary design of each subsystem were performed.

Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography

  • Kim, Dong-Yeon;Kim, Chong-Myeong;Kim, Ji-Hwan;Kim, Hae-Young;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.3
    • /
    • pp.176-181
    • /
    • 2017
  • PURPOSE. The purpose of this study was to evaluate the marginal and internal gaps of Ni-Cr and Co-Cr copings, fabricated using the dental ${\mu}-SLA$ system. MATERIALS AND METHODS. Ten study dies were made using a two-step silicone impression with a dental stone (type IV) from the master die of a tooth. Ni-Cr (NC group) and Co-Cr (CC group) alloy copings were designed using a dental scanner, CAD software, resin coping, and casting process. In addition, 10 Ni-Cr alloy copings were manufactured using the lost-wax technique (LW group). The marginal and internal gaps in the 3 groups were measured using a digital microscope ($160{\times}$) with the silicone replica technique, and the obtained data were analyzed using the non-parametric Kruskal-Wallis H test. Post-hoc comparisons were performed using Bonferroni-corrected Mann-Whitney U tests (${\alpha}=.05$). RESULTS. The mean (${\pm}$ standard deviation) values of the marginal, chamfer, axial wall, and occlusal gaps in the 3 groups were as follows: $81.5{\pm}73.8$, $98.1{\pm}76.1$, $87.1{\pm}44.8$, and $146.8{\pm}78.7{\mu}m$ in the LW group; $76.8{\pm}48.0$, $141.7{\pm}57.1$, $80.7{\pm}47.5$, and $194.69{\pm}63.8{\mu}m$ in the NC group; and $124.2{\pm}52.0$, $199.5{\pm}71.0$, $67.1{\pm}37.6$, and $244.5{\pm}58.9{\mu}m$ in the CC group. CONCLUSION. The marginal gap in the LW and NC groups were clinically acceptable. Further improvement is needed for CC group to be used clinical practice.

Modeling the Impacts of Increased Urbanization on Local Meteorology in the Greater Seoul Area (수도권지역 도시화가 국지기상에 미치는 영향 모델링)

  • Kang, Yoon-Hee;Kim, Yoo-Keun;Oh, In-Bo;Hwang, Mi-Kyoung;Song, Sang-Keun
    • Journal of Environmental Science International
    • /
    • v.19 no.12
    • /
    • pp.1361-1374
    • /
    • 2010
  • The impact of urbanization on local meteorology (e.g., surface temperature, PBL height, wind speed, etc.) in the Greater Seoul Area (GSA) was quantitatively evaluated based on a numerical modeling approach during a 1-month period of 2001 (9 Sep. through 8 Oct. 2001). The analysis was carried out by two sets of simulation scenarios: (1) with the global land use and topographic data from the U.S. Geological Survey (USGS) in 1990s (i.e., LU-USGS case) and (2) with the land use data from the Environmental Geographic Information System (EGIS) along with the 3 sec elevation data from the Shuttle Radar Topography Mission (SRTM) in 2000s (i.e., LU-EGIS case). The extension of urban areas in the GSA (especially, the southern parts of Seoul) accounted for 1.8% in the LU-USGS case and 6.2% in the LU-EGIS case. For the simulations, the surface temperature and PBL height due to urbanization in the LU-EGIS case was higher (the differences of up to $0.1^{\circ}C$ and 36 m, respectively) than those in the LU-USGS case, whereas the wind speed (up to 0.3 $ms^{-1}$) in the former was lower than that in the latter at 1500 LST. The increase in surface temperature due to urbanization in the GSA (especially, the southern parts of Seoul) was led to the strong convergence of air masses, causing the early sea breeze and its rapid propagation to inland locations. In addition, the vertical mixing motion in the extended urban areas for the LU-EGIS case was predicted to be stronger than that for the LU-USGS case and vice versa for the original urban areas.

Radiation Exposure Evaluation Depending on Radiation Workers' Locations during Dental Radiography (치과방사선 검사 시 방사선작업종사자의 위치에 따른 방사선 노출 평가)

  • Jeong, Cheonsoo;Kim, Jiyoung
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.433-438
    • /
    • 2015
  • To evaluate the radiation exposure level based on radiation workers' locations in dental radiography, the radiation dose rate in the radiographic room, lead glass, and operation system was measured. To that end, various devices were used, such as a Standard(Max-GLS, Shinhung), a panorama (PCH-2500, Vatech), a cephalometric radiography (PCH-2500), and a cone beam CT (PHT-30LFO, Vatech), as well as a PM1405 equipment as a radiation meter. Radiography conditions were set the same as the factors used in the clinical setting. As the result, the cone beam CT turned out the highest with 98 uSv and the standard showed the lowest level with 0.4 uSv/h. The panorama was measured to be higher than the Cephalo due to its different focus mode. On the lead glass surface and in the operation stand, the oral radiography device, panoramic, and Cephalo all were measured below the recording level. However, the cone beam CT was measured to have the leakage dose. Thus, radiation involved workers should be equipped with appropriate protection tools and reduce radiography time as much as possible. In addition, the structure of the radiation chamber should be also designed efficiently. Dental radiography has continued to grow in recent years, so it is necessary take appropriate protection measures for patients and radiation workers.

Evaluation of Marginal and Internal Gap of Cobalt-Chromium Sintering Metal Coping Fabricated by Dental CAD/CAM System (치과 CAD/CAM 시스템으로 제작한 코발트-크롬 소결 금속 코핑의 변연 및 내면 적합도 평가)

  • Kim, Dong-Yeon;Sin, Chun-Ho;Jung, Il-Do;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of dental hygiene science
    • /
    • v.15 no.5
    • /
    • pp.536-541
    • /
    • 2015
  • The purpose of this study was to evaluate the marginal and internal gap of Cobalt (Co)-Chromium (Cr) sintering metal coping fabricated by dental computer-aided design/computer-aided manufacturing systems. Abutment tooth 46 of universal numbering system was selected for the study. Twenty Co-Cr metal copings of two groups were manufactured and scanned. Co-Cr cast metal copings (CCM) group of ten were fabricated using investment, burnout and casing after subtractive manufacturing of wax block. Also, Co-Cr sintering metal copings (CSM) group of ten were fabricated using sintering processing after subtractive manufacturing of Co-Cr soft metal bock. Marginal and internal gap of Co-Cr metal copings of twenty were measured by digital microscope (${\times}160$) with silicone replica technique. The data was analyzed from IBM SPSS Statistics ver. 22.0 Statistical software for Mann-Whitney U test (${\alpha}=0.05$). $Mean{\pm}standard$ deviation of marginal gap of CCM group was $90.12{\pm}61.73{\mu}m$ of CSM group was $60.17{\pm}24.83{\mu}m$. However, two groups was statistically not different (p>0.05). This study showed that CSM group was clinically acceptable adaptation.

Comparisons of the Nursing Workforce with Japan, and the U.S. (한국, 미국, 일본의 간호인력 양성 및 활동 현황 비교)

  • You, Sunju
    • Journal of Digital Convergence
    • /
    • v.11 no.6
    • /
    • pp.275-287
    • /
    • 2013
  • This study aims to derive implications on current problems in the nursing manpower management in Korea through the comparison with the nursing workforce and employmentrent in the United States and Japan. There are various issues in nursing policy, such as nursing shortage, quality of the nursing service, and the increased cost of management due to the high turnover rate of nursing staffs and it is urgent to seek various policy measures to resolve this. Although nursing shortage is a commom problem in the world, the U.S. and Japan were higher rate of employment than Korea in nursing staffs, which implicates the importance of the legislation of mandatory minimum staffing ratios, the establishment of policies such as the fees and charge policy and the nursing work environments. For quality nursing care and patient safety through the stable workforce of qualified nursing staffs, administrative mechanisms that support adequate nurse staffing and promote positive work conditions are needed, for which the improvement of legal system is required.

Cloning and Expression of hpaA Gene of Korean Strain Helicobacter pylori K51 in Oral Vaccine Delivery Vehicle Lactococcus lactis subsp. lactis MG1363

  • Kim Su-Jung;Jun Do-Youn;Yang Chae-Ha;Kim Young-Ho
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.2
    • /
    • pp.318-324
    • /
    • 2006
  • In order to develop an oral vaccine to prevent H. pylori infection, we have expressed the hpaA gene of H. pylori K51 isolated from Korean patients, encoding 29-kDa HpaA that is known to be localized on the cell surface and flagella sheath, in a live delivery vector system, Lactococcus lactis. The hpaA gene, amplified by PCR using the genomic DNA of H. pylori K51, was cloned in the pGEX-2T vector, and the DNA sequence analysis revealed that the hpaA gene of H. pylori K51 had 99.7% and 94.8% identity with individual hpaA genes of the H. pylori 26695 strain (U.K) and the J99 strain (U.S.A). A polyclonal anti-HpaA antibody was raised in rats using GST-HpaA fusion protein as the antigen. The hpaA gene was inserted in an E. coli-L. lactis-shuttle vector (pMG36e) to express in L. lactis. Western blot analysis showed that the expression level of HpaA in the L. lactis transformant remained constant from the exponential phase to the stationary phase, without extracelluar secretion. These results indicate that the HpaA of H. pylori K51 was successfully expressed in L. lactis, and suggest that the recombinant L. lactis expressing HpaA may be applicable as an oral vaccine to induce a protective immune response against H. pylori.