• Title/Summary/Keyword: type specimens

검색결과 2,191건 처리시간 0.029초

On geometry dependent R-curve from size effect law for concrete-like quasibrittle materials

  • Zhao, Yan-Hua;Chang, Jian-Mei;Gao, Hong-Bo
    • Computers and Concrete
    • /
    • 제15권4호
    • /
    • pp.673-686
    • /
    • 2015
  • R-curve based on the size effect law previously developed for geometrically similar specimens (geometry type III) is extended to geometries with variable depth (geometry type I) as well as with variable notch (geometry type II), where the R-curve is defined as the envelope of the family of critical strain energy release rates from specimens of different sizes. The results show that the extended R-curve for type I tends to be the same for different specimen configurations, while it is greatly dependent on specimen geometry in terms of the initial crack length. Furthermore, the predicted load-deflection responses from the suggested R-curve are found to agree well with the testing results on concrete and rock materials. Besides, maximum loads for type II specimen are predicted well from the extended R-curve.

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권4호
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

경질형 폴리우레아의 개발 및 보강 순서에 따른 RC 슬래브의 성능 평가 (Evaluation of Strengthening Performance of Stiff Type Polyurea Retrofitted RC Slab Based on Attachment Procedure)

  • 김장호;박정천;이상원;김성배
    • 콘크리트학회논문집
    • /
    • 제23권4호
    • /
    • pp.511-520
    • /
    • 2011
  • 최근 국내에서는 고분자 화합물인 폴리우레아를 이용하여 보강 성능의 향상을 위한 연질형 폴리우레아를 개발하여 구조물에 적용하였지만 보강 성능은 미비한 것으로 나타났다. 따라서, 이 연구에서는 폴리우레아를 구조물의 보강재로 사용하기 위하여 연질형 폴리우레아의 구성 요소를 변화시켜 경질형 폴리우레아를 개발하였다. 개발된 경질형 폴리우레아는 연질형 폴리우레아에 비해 경도와 인장강도가 향상된 성능을 나타내었다. 경질형 폴리우레아를 일반 구조물의 보강재로 사용하기 위하여 RC 슬래브 시험체를 제작하여 보강 성능을 평가하였으며, 현재 보강재로 사용되는 섬유 시트와 적층하여 보강한 후 성능을 평가하였다. 실험 결과 경질형 폴리우레아만으로 보강한 시험체가 무보강 시험체보다 우수한 강성 증진 효과와 연성 증진 효과를 나타내는 것으로 나타났다. 또한, 섬유 시트를 부착한 후 경질형 폴리우레아를 외부에 도포하여 보강한 시험체는 섬유 시트만으로 보강한 시험체보다 보강 성능이 매우 우수한 것으로 나타났다. 그러나 경질형 폴리우레아를 도포한 후 섬유 시트를 부착한 시험체는 경질형 폴리우레아의 변형을 강성이 높은 섬유 시트가 억제하여 하중이 가해지며 생기는 응력이 한곳에 집중되어 취성적인 파괴 거동을 보이는 것으로 나타났다.

Cyclic testing of weak-axis column-tree connections with formation of plastic hinge at beam splice

  • Oh, Keunyeong;Chen, Liuyi;Hong, Sungbin;Yang, Yang;Lee, Kangmin
    • Earthquakes and Structures
    • /
    • 제8권5호
    • /
    • pp.1039-1054
    • /
    • 2015
  • The purpose of this study was to evaluate the seismic performance of weak-axis column-tree type connections used in steel moment frames. These connections are composed of a shop-welded and fieldbolted steel structure and can improve welding quality. On this basis, column-tree type connections are widely used in steel moment resisting frames in Korea and Japan. In this study, splices designed with a semirigid concept regarding the seismic performance of column-tree connections were experimentally evaluated. The structures can absorb energy in an inelastic state rather than the elastic state of the structures by the capacity design method. For this reason, the plastic hinge might be located at the splice connection at the weak-axis column-tree connection by reducing the splice plate thickness. The main variable was the distance from the edge of the column flange to the beam splice. CTY series specimens having column-tree connections with splice length of 600 mm and 900 mm were designed, respectively. For comparison with two specimens with the main variable, a base specimen with a weak-axis column-tree connection was fabricated and tested. The test results of three full-scale test specimens showed that the CTY series specimens successfully developed ductile behavior without brittle fracture until 5% story drift ratio. Although the base specimen reached a 5% story drift ratio, brittle fracture was detected at the backing bar near the beam-to-column connection. Comparing the energy dissipation capacity for each specimen, the CTY series specimens dissipated more energy than the base specimen.

Occurrence and Molecular Identification of Anisakis Dujardin, 1845 from Marine Fish in Southern Makassar Strait, Indonesia

  • Anshary, Hilal;Sriwulan, Sriwulan;Freeman, Mark A.;Ogawa, Kazuo
    • Parasites, Hosts and Diseases
    • /
    • 제52권1호
    • /
    • pp.9-19
    • /
    • 2014
  • Anisakis spp. (Nematoda: Anisakidae) parasitize a wide range of marine animals, mammals serving as the definitive host and different fish species as intermediate or paratenic hosts. In this study, 18 fish species were investigated for Anisakis infection. Katsuwonus pelamis, Euthynnus affinis, Caranx sp., and Auxis thazard were infected with high prevalence of Anisakis type I, while Cephalopholis cyanostigma and Rastrelliger kanagurta revealed low prevalence. The mean intensity of Anisakis larvae in K. pelamis and A. thazard was 49.7 and 5.6, respectively. A total of 73 Anisakis type I larvae collected from K. pelamis and A. thazard were all identified as Anisakis typica by PCR-RFLP analysis. Five specimens of Anisakis from K. pelamis and 15 specimens from A. thazard were sequenced using ITS1-5.8S-ITS2 region and 6 specimens from A. thazard and 4 specimens from K. pelamis were sequenced in mtDNA cox2 region. Alignments of the samples in the ITS region showed 2 patterns of nucleotides. The first pattern (genotype) of Anisakis from A. thazard had 100% similarity with adult A. typica from dolphins from USA, whereas the second genotype from A. thazard and K. pelamis had 4 base pairs different in ITS1 region with adult A. typica from USA. In the mtDNA cox2 regions, Anisakis type I specimens from A. thazard and K. pelamis showed similarity range from 94% to 99% with A. typica AB517571/DQ116427. The difference of 4 bp nucleotides in ITS1 regions and divergence into 2 subgroups in mtDNA cox2 indicating the existence of A. typica sibling species in the Makassar Strait.

RC 부재의 휨 보강을 위한 외부 비부착형 탄소섬유판 포스트텐션 시스템 (Post-tensioning System with Externally Unbonded CFRP Strips for Strengthening RC Members)

  • 유영찬;최기선;김긍환
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제12권6호
    • /
    • pp.147-154
    • /
    • 2008
  • 본 연구에서는 외부 비부착형 프리스트레스트 탄소섬유판으로 보강된 RC보의 휨거동을 분석하기 위한 실험연구를 수행하였다. 실험체는 프리스트레스 양 및 정착장치의 형상을 변수로 총 10개로 제작되었다. 또한 프리스트레스의 도입에 따른 구조성능 비교를 위하여 기준실험체와 단순부착 실험체를 함께 제작하였다. 실험결과, 단순 부착 탄소섬유판으로 보강된 부재는 조기 박리에 의해 탄소섬유판 인장강도의 50% 이하에서 최종파괴되었다. 그러나, 프리스트레스를 도입하여 보강한 실험체는 모두 탄소섬유판의 파단하중까지 도달하였다. 또한 스터드형 정착장치를 적용한 실험체들의 보강성능은 매립형 정착장치를 적용한 실험체와 동등한 보강성능을 나타내었다.

Relationship between the Applied Torque and CCT to obtain the Same Corrosion Resistance for the Plate and Cylindrical Shape Stainless Steels

  • Chang, Hyun Young;Kim, Ki Tae;Kim, Nam In;Kim, Young Sik
    • Corrosion Science and Technology
    • /
    • 제15권2호
    • /
    • pp.58-68
    • /
    • 2016
  • Many industries need the universal standard or technique to obtain the identical CCT regardless of specimen geometries. This study aimed to determine an appropriate applied torque to the cylindrical specimen defining the apparatus and the procedure to measure the temperature of initiating crevice corrosion in tubular shape products such as pipes, tubes and round rods etc; the test method also proved applicable to the plate type specimen. A series of experiments for CCT measurements with the plate type and cylindrical stainless steel specimens of various diameters with different microstructures (austenitic and duplex) and PRENs were conducted to determine the relationship among geometries on CCT. Thus, the apparatus that could measure the CCT of stainless steels with both plate and cylindrical geometries was newly designed. The use of the apparatus facilitated the same CCT value for both geometries only if the specimens were made of the same alloy. The applied torque can be calculated for various diameters of the cylindrical specimens using the following relation; Applied torque, $Nm=-0.0012D^2+0.019D+2.4463$ (D; the diameter of cylindrical specimen, mm). However, upwards of 35 mm diameter cylindrical specimens require 1.58Nm, which is the same torque for the plate type specimen; in addition, this test method cannot be used for cylindrical specimens of less than 15 mm diameter.

주문진 어시장 살오징어(Todarodes pacificus)의 아니사키스 유충 감염상 (Infection Status of Todarodes pacificus (Mollusca: Cephalopoda) with Anisakid Larvae in the Markets from Jumungin)

  • 전계식;김세화
    • 한국해양학회지:바다
    • /
    • 제1권1호
    • /
    • pp.55-57
    • /
    • 1996
  • 1995년 11, 12월에 동해안 주문진 어시장에서 구입한 살오징어(Todarodes pacificus) 248개체중 34개체로부터 116개체의 아니사키스 유충이 채집되어 13.7% 의 유충 감염율을 나타내었다. 형태 및 크기를 바탕으로 유충의 종류 및 근육, 내장, 망 등 어체 부위별 감염상황을 조사한 결과 유충의 길이는 13.5-29.5 mm 이었으며 Anisakis type I이 68개체 (58.6%:회수율), Contracaecum type A 5개 체 (4.3%), Anisakis type II 17개체 (14.6%), Contracaecum type D 8개체 (7.0%) 및 불명 18개체 (15.5%)로 분류되었다.

응력비 변화에 따른 십자형 접합부의 피로거동 평가 (An Estimation of the Fatigue Behavior on the Cruciform Type Specimen by Variation of the Stress Ratio)

  • 김태봉;서상구;우상익
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.140-145
    • /
    • 2000
  • 강교량 부재인 십자연결형 접착부를 하중비전달형과 하중전달형으로 각각 제작하여 피로 강도 저감 정도와 응력비 변화에 따른 피로거동을 평가하였다. 또한, 필렛용접 비드의 기하학적 형상에 따른 응력집중을 확인하기 위하여 전산해석을 수행하였다. 피로실험 결과 시험편의 응력비가 피로 강도에 미치는 영향은 거의 없는 것으로 나타났으며, 하중전달형 시험편과 대부분의 밀착 시험편은 용접지단부에서 균열이 발생하여 모재가 파단됨을 알 수 있었다. 모재가 파단된 십자형 시험편의 피로강도는 ${\Delta}\sigma_c$=63.5 MPa로 하중 비전달형 시험편의 피로강도 ${\Delta}\sigma_c$=83.8 MPa보다 약 24% 작게 나타났다. 본 연구대상 시험편은 도로교 시방서상에 모재단면에 대한 응력으로 피로범주 C등급으로 규정하고 있으므로, 실험결과를 모재단면에 대한 응력으로 피로강도를 환산하면 78.27 MPa로 허용 피로강도보다 작은 것으로 나타났다.

  • PDF

스핀-코팅법으로 제작한 K(Ta,Nb)O3/Pb(Zr,Ti)O3 이종층 박막의 전기 열량 효과 (Electrocaloric Effect in Heterolayered K(Ta,Nb)O3/Pb(Zr,Ti)O3 Thin Films Fabricated by Spin-Coating Method)

  • 양영민;육지수;김지원;이삼행;박주석;김영곤;이성갑
    • 한국전기전자재료학회논문지
    • /
    • 제33권6호
    • /
    • pp.465-470
    • /
    • 2020
  • Heterolayered K(Ta,Nb)O3/Pb(Zr,Ti)O3 thin films on Pt/Ti/SiO2/Si substrates were prepared by a sol-gel process and spin-coating method. The structural and electrical properties were measured to investigate the possibility of application as an electrocaloric effect device. All specimens exhibited dense and uniform cross-sectional structures without pores, and the average thickness of the specimen coated six times was approximately 394 nm. Curie temperatures were observed at 5℃ or less in type-I and 10℃ in type-II specimens, respectively. Type-II specimens coated 6 times showed a relative dielectric constant of 758 and remanent polarization of 9.71 μC/㎠ at room temperature. The maximum electrocaloric effect occurred between 20 and 25℃, slightly higher than their Curie temperature, and the electrocaloric property (ΔT) of the type-II specimens coated 6 times was approximately 1.2℃ at room temperature.