Analysis and Discussion of Small-size Roundabout Accidents by Vehicle Type (차종별 소규모 회전교차로 사고의 분석 및 논의)

  • Cho, Ah Hae;Park, Byung Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.6
    • /
    • pp.131-136
    • /
    • 2017
  • This study deals with the small-size roundabout accidents. The purpose of this study is to analyze the characteristics of small-size roundabout accidents from developing various types of accident models, and to discuss the improvement countermeasures by vehicle type. The geometric characteristics of 36 roundabouts are surveyed, and the traffic accident data from 2008 to 2014 are collected and classified as those of car, truck and motor cycle. In this study, dependent variable is the number of accident and independent variables are such 15 variables as geometry and traffic volume. The main results are as follows. First, the null hypotheses that the size of roundabout and type of vehicle are not related to traffic accident are rejected. Second, 8 count data models which are all statistically significant are developed. Third, the number of circulatory roadway lane and sidewalk are selected as common variables of roundabout size. Finally, the number of entry and circulatory roadway lane are selected as common variables of vehicle type.

Designation of Bodytypes and Size Specifications for Designing of the Ready-made Jacket (신사복 상의 설계를 위한 체형의 호칭 분류와 사이즈 스팩;36세에서 43세 우리나라 남성을 대상으로)

  • 김구자
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.8
    • /
    • pp.1240-1247
    • /
    • 1999
  • The purpose of this study was to classify size specifications of Korean adult male for the men's ready-made garments especially jacket and dress shirts By the stratified sampling method data were collected by the real anthropometric measurement. Sample size was 263 subjects as the sample and their age range was from 36 to 43 years old 66 variables from the direct anthropometric data were applied to analyze. ANOVA is SPSSWIN 8.0 package was applied to the data and the expected frequency distribution of 10.000 men was calculated by the extraction of density function. This study was performed to classify size specificatios by the control dimensions. The drop values of 9,12 and 6 have the high coverage rate of 28.52% 23.44% respectively Obese body type ; H type HD type and HE type are composed of the majority of 55.47% of the subjects. According to the drop values size specifications and distribution of control dimensions are predicted About 69.82% of the expected frequency distribution were covered by 19 size specifications.

  • PDF

Lower Body Type Classification by Buttocks Shapes of Korean Women in Their 20's (국내 20대 여성의 엉덩이 형태에 따른 하반신 체형 분류)

  • Choi, Se-Lin;Do, Wol-Hee
    • Fashion & Textile Research Journal
    • /
    • v.18 no.3
    • /
    • pp.327-337
    • /
    • 2016
  • The purpose of this study is for size suitability and fitness improvement for Korean 20's women. This study has classified hip types of 20's women by the 6th Korean Anthropometric Survey(Size Korean), then compared their lower body-type by hip types each other. The results are as follows. Factor analysis in sorting hip types can be explained 77.72% by nine factors. And cluster analysis can be divided into three types. Type 1 is referred to as a general type which has the largest size in the 'Hip circumference', but the buttocks's horizontal sizes are in the middle size besides the hip line. Type 2 is referred to as a protruding type in upper buttocks which is large in protruding volume of upper buttocks, but the buttock's horizontal sizes are small including 'Hip circumference', and buttock's horizontal section form close to circle. Type 3 is referred to as a type which is contrary to Type 2. Type 3 is small in protruding volume of upper buttocks, but large in lower buttocks, and the protrusions in whole buttocks are small, so the side view of Type 3 made gentle fit shape. By these results, the study could classify lower body of 20's women, and it can be basic data for new sizing systems and pattern development of bottoms.

Analytical Approach for Optimal Allocation of Distributed Generators to Minimize Losses

  • Kaur, Navdeep;Jain, Sanjay Kumar
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.6
    • /
    • pp.1582-1589
    • /
    • 2016
  • In this paper the integration of Distributed Generation (DG) in radial distribution system is investigated by computing the optimal site and size of DG to be placed. An analytical expression based on equivalent current injection has been derived by utilizing topological structure of radial distribution system to find optimal size of DG to minimize losses. In the presented formulation, the optimal DG placement is obtained without repeatedly computing the load flow. The proposed formulation can be used to find the optimal size of all types of DGs namely Type-I, Type-II, Type-III and Type-IV DGs. The investigations are carried out on IEEE 33-bus and 69-bus radial distribution systems. The optimal DG placement results into reduction in active and reactive power losses and improvement in voltage profile of the buses.

A study on the Characteristics of the Blowing type Rotary Burner (송풍형 로터리 버너의 특성 연구)

  • Choi Y. H.;Kim K. H.;Yoon S. J.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.303-306
    • /
    • 2002
  • Liquid atomization by means of a spinning cup is widely used as a device for combustion, in cooling and spray drying. In this study, the blowing type rotary atomizer was experimental carried out the investigations on the characteristics of the blowing type rotary atomizer which is an air flow energy of blower instead of an electric motor most commonly used to a driven energy. The analysis on the rotary cup speed, air velocity with the blower conditions was performed and also the drop size was measured using LDPA. It was tried to analyzed on air-nozzle size and liquid flowrate as the result. It was found that the increase of the relative velocity between liquid and air improve significantly atomization liquid, and decrease of the liquid flowrate improved the maximum drop size though the mean drop size is really the same.

  • PDF

A Small Size Broadband MEMS Antenna for 5 GHz WLAN Applications

  • Kim, Ji-Hyuk;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.5 no.3
    • /
    • pp.204-209
    • /
    • 2005
  • A small size broadband microstrip patch antenna with small ground plane has been fabricated using MEMS. Multiple layer substrates are used to realize small size and broadband characteristics. The microstrip patch is divided into 3 pieces and each patch is connected to each other using a metal microstrip line. The fabrication process is simple and only one mask is needed. Two types of microtrip antennas are fabricated. Type A is the micros trip antenna with metal lines and type B is the microstrip antenna without metal lines. The size of proposed microstip antenna is $8^{*}12^{*}2mm^{3}$ and the experimental results show that the antenna type A and type B have the bandwidth of 420 MHz at 5.3 GHz and 480 MHz at 5.66 GHz, respectively.

A Small Size Broadband MEMS Antenna for 5 GHz WLAN Applications (5GHz 무선랜 응용을 위한 소형 광대역 MEMS 안테나)

  • Kim, Ji-Hyuk;Kim, Hyeon-Cheol;Chun, Kuk-Jin
    • Proceedings of the IEEK Conference
    • /
    • 2006.06a
    • /
    • pp.603-604
    • /
    • 2006
  • A small size broadband microstrip patch antenna with small ground plane has been fabricated using MEMS. Multiple layer of high and low dielectric substrates are used to realize small size and broadband characteristics. The microstrip patch is divided into 4 pieces and each patch is connected to each other using a metal microstrip line. The fabrication process is very simple and only one mask is needed. Two types of microtrip antennas are fabricated. Type A is the microstrip antenna with metal lines and type B is the microstrip antenna without metal lines. The size of proposed microstip antenna is $8*12*2mm^3$ and the experimental results show that the antenna type A and type B have the bandwidth of 420MHz at 5.3 GHz and 480MHz at 5.66 GHz, respectively.

  • PDF

Studies on Grain Size Refinement for Rheocasting of Hypereutectic Al-18% Si by Using Sieve Type Mechanical Stirrer (과공정 Al-18% Si 합금의 레올로지 성형시 기계적 교반을 이용한 입자 미세화 연구)

  • 강용기;박진욱;강성수;강충길;문영훈
    • Transactions of Materials Processing
    • /
    • v.9 no.4
    • /
    • pp.389-394
    • /
    • 2000
  • The studies on gram size refinement for rheocast processing of hypereutectic Al-18%Si alloys have been investigated in the present study. To increase the efficiency of mechanical stirring, sieve type stirrer are newly designed and implemented for rheocasting of hypereutectic Al-18%Si alloy. Mechanical stirring of semi-solid slurry by using sieve type mechanical stirrer results in morphological changes of the primary Si particles, from angular rod shape to near spherical shape and uniform distribution of proeutectic Si. The remarkable spheroidization of Primary Si Particles and distributional uniformity of proeutectic Si show well the efficiency of sieve type mechanical stirring method which can accelerate the coalescence-fracture-wear of the individual particles by strong turbulent flow between lattices during rotation of sieve type stirrer.

  • PDF

Development of the Micro PM type Stepping Motor with Newly Structure (새로운 구조를 갖는 마이크로 PM형 스테핑 모터 개발)

  • Rhyu, Se-Hyun;Kwon, Byung-Il;Jung, In-Soung;Sung, Ha-Gyeong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1261-1263
    • /
    • 2005
  • The micro permanent magnet(PM) type stewing motor preferred solution for many small electronics position determination devices since it is small in size. Thus, there are growing demands for PM type stepping motor that greater mechanical output, smaller size. But, the design of the it, having high performance and small size is very difficult because of its complex mechanical structure. This paper deals with a development of the newly structured micro PM type stepping motor with claw-poles. We introduced the small-sized PM type stepping motor that has new structure and analyzed the magnetic characteristic of it versus general type model using 3-D finite element analysis(FEA).

  • PDF

Plasma LDL Particle Sizes Affect the Blood Lipid Profile and Dietary Intakes among Korean Adults (한국 성인에서 혈중 LDL 입자의 크기에 영향을 미치는 관련 인자 연구)

  • 서연경;김형숙;김정숙;김철호;최혜미
    • Korean Journal of Community Nutrition
    • /
    • v.9 no.1
    • /
    • pp.58-65
    • /
    • 2004
  • The purpose of this research was to examine the relationship between the plasma LDL particle size and blood lipid profile, dietary factors and anthropometric values (body mass index, waist circumference and waist/hip ratio). The subjects were 173 adults aged 23 to 81 years, selected from the Outpatient Clinic and Cardiovascular Department of the Seoul Municipal Hospital. Dietary data were obtained using a 3-day food record and analyzed using Korean and US nutrient databases. The subjects were divided into three groups by LDL particle size : type A (large buoyant LDL, > 25.5 nm, n=96), type I (Intermediate LDL,$25.2\leq-\leq25.5$ nm, n=18), and type B (small dense LDL, < 25.2 nm, n=59) groups. The type B group had higher age, waist circumference, and waist/hip ratio (WHR) than the type A and type I groups. Serum concentration of triglyceride, Apo B, LDL/HDL cholesterol ratio and atherogenic index were significantly higher in the type B group as compared to those in the other two groups. HDL cholesterol level and Apo A-I/Apo B ratio were significantly lower in the type B group than the other two groups. The plasma LDL particle size was highly correlated with triglyceride (r= -0.450), Apo B (r= -0.402) and HDL cholesterol (r= 0.418). However, there was no correlation between plasma LDL particle size and dietary intakes. This study showed that small dense LDL was an important biochemical risk factor that was associated with other risk factors.