• Title/Summary/Keyword: two-probe method

Search Result 269, Processing Time 0.03 seconds

Noninvasive Method to Distinguish between Glucose and Sodium Chloride Solution Using Complementary Split-Ring Resonator (Complementary Split Ring Resonator(CSRR)를 이용한 포도당과 염화나트륨 수용액의 비침습적 구별)

  • Jang, Chorom;Park, Jin-Kwan;Yun, Gi-Ho;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.4
    • /
    • pp.247-255
    • /
    • 2018
  • In this work, glucose solution and sodium chloride solution were distinguished noninvasively using a microwave complementary split-ring resonator (CSRR). Based on the electrical properties of the two solutions measured using a open-ended coaxial probe, a CSRR was designed and fabricated for operation at a specific frequency that facilitates differentiating the two solutions. Furthermore, a polydimethylsiloxane mold was fabricated to concentrate the solution at a region where the electric field of the resonator was strongest, and a laminating film was used to prevent contact between the solution and resonator. Experiments were performed by dropping $50{\mu}L$ of the solution in steps of 100 mg/dL up to a maximum human blood glucose level of 400 mg/dL. Our experiments confirmed that the transmission coefficients ($S_{21}$) of glucose solution and sodium chloride solution exhibit variations of -0.06 dB and 0.14 dB, respectively, per 100 mg/dL concentration change at the resonance frequency. Thus, the opposite trends in the variation of $S_{21}$ with change in the concentration of the two solutions can be used to distinguish between them.

AC transport current loss analysis for a face-to-face stack of superconducting tapes

  • Yoo, Jaeun;Youm, Dojun;Oh, SangSoo
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.34-38
    • /
    • 2013
  • AC Losses for face to face stacks of four identical coated conductors (CCs) were numerically calculated using the H-formulation combined with the E-J power law and the Kim model. The motive sample was the face to face stack of four 2 mm-wide CC tapes with 2 ${\mu}m$ thick superconducting layer of which the critical current density, $J_c$, was $2.16{\times}10^6A/cm^2$ on IBAD-MgO template, which was suggested for the mitigation of ac loss as a round shaped wire by Korea Electrotechnology Research Institute. For the calculation the cross section of the stack was simply modeled as vertically aligned 4 rectangles of superconducting (SC) layers with $E=E_o(J(x,y,t)/J_c(B))^n$ in x-y plane where $E_o$ was $10^{-6}$ V/cm, $J_c$(B) was the field dependence of current density and n was 21. The field dependence of the critical current of the sample measured in four-probe method was employed for $J_c$(B) in the equation. The model was implemented in the finite element method program by commercial software. The ac loss properties for the stacks were compared with those of single 4 cm-wide SC layers with the same critical current density or the same critical current. The constraint for the simulation was imposed in two different ways that the total current of the stack obtained by integrating J(x,y,t) over the cross sections was the same as that of the applied transport current: one is that one fourth of the external current was enforced to flow through each SC. In this case, the ac loss values for the stacks were lower than those of single wide SC layer. This mitigation of the loss is attributed to the reduction of the normal component of the magnetic field near the SC layers due to the strong expulsion of the magnetic field by the enforced transport current. On the contrary, for the other case of no such enforcement, the ac loss values were greater than those of single 4cm-wide SC layer and. In this case, the phase difference of the current flowing through the inner and the outer SC layers of the stack was observed as the transport current was increased, which was a cause of the abrupt increase of ac loss for higher transport current.

The Estimation of Link Travel Time for the Namsan Tunnel #1 using Vehicle Detectors (지점검지체계를 이용한 남산1호터널 구간통행시간 추정)

  • Hong Eunjoo;Kim Youngchan
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.1 no.1
    • /
    • pp.41-51
    • /
    • 2002
  • As Advanced Traveler Information System(ATIS) is the kernel of the Intelligent Transportation System, it is very important how to manage data from traffic information collectors on a road and have at borough grip of the travel time's change quickly and exactly for doing its part. Link travel time can be obtained by two method. One is measured by area detection systems and the other is estimated by point detection systems. Measured travel time by area detection systems has the limitation for real time information because it Is calculated by the probe which has already passed through the link. Estimated travel time by point detection systems is calculated by the data on the same time of each. section, this is, it use the characteristic of the various cars of each section to estimate travel time. For this reason, it has the difference with real travel time. In this study, Artificial Neural Networks is used for estimating link travel time concerned about the relationship with vehicle detector data and link travel time. The method of estimating link travel time are classified according to the kind of input data and the Absolute value of error between the estimated and the real are distributed within 5$\~$15minute over 90 percent with the result of testing the method using the vehicle detector data and AVI data of Namsan Tunnel $\#$1. It also reduces Time lag of the information offered time and draws late delay generation and dissolution.

  • PDF

$TiO_2$ Thin Film Patterning on Modified Silicon Surfaces by MOCVD and Microcontact Printing Method

  • 강병창;이종현;정덕영;이순보;부진효
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2000.02a
    • /
    • pp.77-77
    • /
    • 2000
  • Titanium oxide (TiO2) thin films have valuable properties such as a high refractive index, excellent transmittance in the visible and near-IR frequency, and high chemical stability. Therefore it is extensively used in anti-reflection coating, sensor, and photocatalysis as electrical and optical applications. Specially, TiO2 have a high dielectric constant of 180 along the c axis and 90 along the a axis, so it is highlighted in fabricating dielectric capacitors in micro electronic devices. A variety of methods have been used to produce patterned self-assembled monolayers (SAMs), including microcontact printing ($\mu$CP), UV-photolithotgraphy, e-beam lithography, scanned-probe based micro-machining, and atom-lithography. Above all, thin film fabrication on $\mu$CP modified surface is a potentially low-cost, high-throughput method, because it does not require expensive photolithographic equipment, and it produce micrometer scale patterns in thin film materials. The patterned SAMs were used as thin resists, to transfer patterns onto thin films either by chemical etching or by selective deposition. In this study, we deposited TiO2 thin films on Si (1000 substrateds using titanium (IV) isopropoxide ([Ti(O(C3H7)4)] ; TIP as a single molecular precursor at deposition temperature in the range of 300-$700^{\circ}C$ without any carrier and bubbler gas. Crack-free, highly oriented TiO2 polycrystalline thin films with anatase phase and stoichimetric ratio of Ti and O were successfully deposited on Si(100) at temperature as low as 50$0^{\circ}C$. XRD and TED data showed that below 50$0^{\circ}C$, the TiO2 thin films were dominantly grown on Si(100) surfaces in the [211] direction, whereas with increasing the deposition temperature to $700^{\circ}C$, the main films growth direction was changed to be [200]. Two distinct growth behaviors were observed from the Arhenius plots. In addition to deposition of THe TiO2 thin films on Si(100) substrates, patterning of TiO2 thin films was also performed at grown temperature in the range of 300-50$0^{\circ}C$ by MOCVD onto the Si(100) substrates of which surface was modified by organic thin film template. The organic thin film of SAm is obtained by the $\mu$CP method. Alpha-step profile and optical microscope images showed that the boundaries between SAMs areas and selectively deposited TiO2 thin film areas are very definite and sharp. Capacitance - Voltage measurements made on TiO2 films gave a dielectric constant of 29, suggesting a possibility of electronic material applications.

  • PDF

A Case of Congenital Midline Fistula of the Lower Lip (아랫입술에 생긴 선천성 샛길 증례)

  • Choi, Hwan-Jun;Choi, Yim-Don;Choi, Chang-Yong;Kim, Sook;Kim, Yong-Bae
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.73-76
    • /
    • 2011
  • Purpose: Congenital midline upper lip sinus is a rare lesion. There are two postulates that can account for the formation of the upper lip sinus based on two major theories of the development of the face: the fusion theory and the merging theory. However, congenital midline lower lip sinus is very rarely reported and described. We report a case of a congenital midline sinus of the lower lip in a 6-year-old female. Methods: A 6-year-old girl presented with a nipple like swelling on the midline lower lip. Physical examination revealed about $5{\times}5$ mm protruding round mass with a just small opening that was non-tender to palpation. The mass was not associated with any skin changes. It umbilicated at the apex and contains a fistulous tract, discharging clear fluid. Only, simple radiologic finding shows bony spur on the lower one third of mandibular symphsis. Results: A small transverse ellipse is made around the opening and elevated mass with sharpe dissection. The tract is excised using the probe and dye as the guide. The tract was extended to periosteum of the lower one third of the mandible. The tract and involved periosteum were excised en bloc, and removed protrusion of the mandibular bone using diamond burr. Microscopic examination of the resected sinus revealed the fistulous tract itself, consisting of fibrous connective tissue covered with cornified stratified squamous epithelium, was observed in the center of the sample. In 6 months follow-up, This patient had a good result was obtained by the method of fistulectomy alone. Conclusion: Midline cranoifacial fistulas represent rare lesions resulting from abnormal fusion of embryologic structures. Our case report describes the excision of a congenital midline sinus of the lower lip in a 6-year-old female. This case represents the first report of a lower lip sinus presenting in a girl as a mass in the skin of the chin with extension to the midline of the mandible. However, the etiology of this rare congenital sinus remains obscure.

Development of Radiosynthetic Methods of 18F-THK5351 for tau PET Imaging (타우 PET영상을 위한 18F-THK5351의 표지방법 개발)

  • Park, Jun-Young;Son, Jeong-Min;Chun, Joong-Hyun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.1
    • /
    • pp.51-54
    • /
    • 2018
  • Purpose $^{18}F-THK5351$ is the newly developed PET probe for tau imaging in alzheimer's disease. The purpose of study was to establish the automated production of $^{18}F-THK5351$ on a commercial module. Materials and Methods Two different approaches were evaluated for the synthesis of $^{18}F-THK5351$. The first approach (method I) included the nucleophilic $^{18}F$-fluorination of the tosylate precursor, subsequently followed by pre-HPLC purification of crude reaction mixture with SPE cartridge. In the second approach (method II), the crude reaction mixture was directly introduced to a semi-preparative HPLC without SPE purification. The radiosynthesis of $^{18}F-THK5351$ was performed on a commercial GE $TRACERlab^{TM}$ $FX-_{FN}$ module. Quality control of $^{18}F-THK5351$ was carried out to meet the criteria guidelined in USP for PET radiopharmaceuticals. Results The overall radiochemical yield of method I was $23.8{\pm}1.9%$ (n=4) as the decay-corrected yield (end of synthesis, EOS) and the total synthesis time was $75{\pm}3min$. The radiochemical yield of method II was $31.9{\pm}6.7%$ (decay-corrected, n=10) and the total preparation time was $70{\pm}2min$. The radiochemical purity was>98%. Conclusion This study shows that method II provides higher radiochemical yield and shorter production time compared to the pre-SPE purification described in method I. The $^{18}F-THK5351$ synthesis by method II will be ideal for routine clinical application, considering short physical half-life of fluorine-18 ($t_{1/2}=110min$).

Genetic Characteristics and Virulence Factors of Pandemic Vibrio parahaemolyticus Isolated in South Korea and Japan (한국과 일본에서 유행하는 장염비브리오의 병원성 인자와 유전자의 특성)

  • Hong, Seuk-Won;Moon, Ji-Young;Lee, Bok-Kwon;Kim, Yung-Bu
    • Journal of Life Science
    • /
    • v.17 no.3 s.83
    • /
    • pp.386-395
    • /
    • 2007
  • A total of 27 strains of Vibrio parahaemolyticus (18 strains isolated from Korea and 9 strains from Japan) were serotyped and examined for biochemical characteristics, antimicrobial susceptibility patterns, cytotoxicity assay, thermostable direct hemolysin (TDH) production and molecular epidemiology. Using polymerase chain reaction (PCR) method and DNA probe hybridization method, the strains were tested for toxR, tdh, trh and ORF 8 genes. The V. parahaemolyticus isolated from patients were belonged to 8 different serotypes : O3:K6, O1:K38, O3:K57, O4:K9, O4:Kl2, O4:K68, O5:Kl5 and O6:K46. Urease-positive strain possessed the trh gene, and conversely, urease-negative strains lacked the gene, indicating that urease production by V. parahemolyticus strains strongly correlates with the possession of the trh gene. Most strains showed multiple resistant to more than three antibiotics and the antibiogram could be classified into 6 group (I to VI). All of the O3:K6 strains isolated in South Korea and Japan producted TDH at high levels. The TDH titers ranged between 256 and 2.048, and the average titer was 1009. To distinguish the new and increasingly common V. parahaemolyticus strains from clinical isolates, ORF 8 is a useful genetic marker. After Southern hybridization, the HindIII restriction fragment patterns of the tdh gene were grouped one type, respectively. One type showed two bands one of which was 4.3kb and the other was 11.5kb in size. Variation between the O3:K6 serotype are minor when compared to the differences seen with the non O3:K6 strains. The migration patterns of Not I -digested of the total DNA of the O3:K6 strains were similar, and only slight variations were observed between the serotypes. By contrast, the O3:K6 strains and non O3:K6 had markedly different profiles. In conclusion, Random amplified polymorphic DNA (RAPD) profile using appropriate primers was an effective epidemiological marker.

Establishment and Application of a Multibead Serotyping Assay for Pneumococci in Korea (다중구슬 폐구균 혈청형 분석법의 국내 확립과 적용 연구)

  • Kim, Han Wool;Lee, Soyoung;Lee, Miae;Kim, Kyung-Hyo
    • Pediatric Infection and Vaccine
    • /
    • v.22 no.2
    • /
    • pp.97-105
    • /
    • 2015
  • Purpose: Serotyping pneumococcal isolates is important to monitor efficacy of pneumococcal vaccines. Because of difficulties of typing pnueumocci, a multiplex bead-based (multibead) serotyping assay was recently introduced. The aim of this study is to establish a new multibead serotyping assay and to apply this method to analyze clinical isolates of pneumococci in Korea. Methods: To establish the multibead serotyping assay, six key reagents were transferred from University of Alabama at Birmingham (UAB) to Ewha Center for Vaccine Evaluation and Study (ECVES): bead set coated with polysaccharide and monoclonal antibody pool were used in one multiplex inhibition-type immunoassay and 2 bead sets coated DNA probe and 2 primer pools were used in two multiplex PCR-based assays. After multibead serotyping assay was set up, 75 test samples of pneumococci were analyzed whether ECVES is able to identify serotype correctly. After confirming the performance, serotyping assay was applied to identify serotypes of 528 clinical isolates of pneumococci collected from 3 different hospitals. Results: After establishment of the multibead pneumococcal serotyping assay system at ECVES, 75 test samples were analyzed. There was no discrepancy of serotypes of 75 test samples between the results assigned at UAB and those at ECVES. The serotypes of 528 pneumococci isolated from patients or healthy subjects were determined in 94.3% of isolates (498/528). Conclusions: The multibead pneumococcal serotyping assay can be successfully established in Korea. With this method, surveillance of serotypes of pneumococci isolated from patients as well as healthy subjects could be studied.

Development of a SNP marker set related to crown gall disease in grapevines by a genome wide association study

  • Kim, Dae-Gyu;Jang, Hyun A;Lim, Dong Jun;Hur, Youn Young;Lee, Kyo-Sang;Min, Jiyoung;Oh, Sang-Keun
    • Korean Journal of Agricultural Science
    • /
    • v.47 no.3
    • /
    • pp.693-705
    • /
    • 2020
  • Grapes (Vitis spp. L.) are the third most produced fruit in the world. Crown gall disease caused by Agrobacterium vitis forms galls in the stems of the grapevines and reduces the vitality of the fruit trees, resulting in reduced yields. This pathogen has occurred in vineyards worldwide and caused serious economic losses. It is a soil-borne disease, so Agrobacterium vitis can survive for several years in vineyards and is difficult to control. Additionally, since there is no effective chemical control method, the most effective control method is the breeding of resistant varieties. To make the resistant variety, marker-assisted selection (MAS) enables fast breeding with low cost. In this study, we applied a genome-wide association study (GWAS), by combining phenotyping and genotyping-by-sequencing (GBS), for the development of a single nucleotide polymorphism (SNP) marker set related to crown gall disease using 350 grapevine varieties. As a result of the GBS based genotyping analysis, about 58,635 SNPs were obtained. In addition, the phenotypic analysis showed 35.2% resistance, 73% moderate susceptibility and 16.4% highly susceptibility. Moreover, after confirmation, two genes (VvARF4 and VvATL6-like) were shown to be related to crown gall disease based on the results of GWAS analysis, using the phenotypic data, and GBS. High-resolution melting analysis (HRMA) was performed using the Luna® Universal Probe with real-time PCR to distinguish the melting peaks of the resistant and susceptible varieties. Our data show that these SNP markers are expected to be helpful in evaluating resistance against grapevine crown gall disease and in breeding.

HIGH HEAT FLUX TEST WITH HIP BONDED 35X35X3 BE/CU MOCKUPS FOR THE ITER BLANKET FIRST WALL

  • Lee, Dong-Won;Bae, Young-Dug;Kim, Suk-Kwon;Jung, Hyun-Kyu;Park, Jeong-Yong;Jeong, Yong-Hwan;Choi, Byung-Kwon;Kim, Byoung-Yoon
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.662-669
    • /
    • 2010
  • To develop the manufacturing methods for the blanket first wall (FW) of the International Thermonuclear Experimental Reactor (ITER) and to verify the integrity of the joint, Be/Cu mockups were fabricated and tested at the KoHLT-1 (Korea Heat Load Test facility), a graphite heater facility located at the Korea Atomic Energy Research Institute (KAERI). Since Be and Cu joining is the focus of the present study, the fabricated mockups had a CuCrZr heat sink joined with three Be tiles as an armor material, unlike the original ITER blanket FW, which has a stainless steel structure and coolant tubes. Hot isostatic pressing (HIP) was carried out at $580^{\circ}C$ and 100 MPa for 2 hours as the method for Be/Cu joining. Three interlayers, namely, $1{\mu}mCr/10{\mu}mCu$, $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$, and $5{\mu}mTi/10{\mu}mCu$ were applied as a coating to the Be tiles by a physical vapor deposition (PVD) method. A shear test was performed with the specimens, which were fabricated by the same methods as those used to fabricate the mockups. The average values were 125 MPa to 180 MPa, and the samples with the $1{\mu}mCr/10{\mu}mCu$ interlayer showed the lowest value. No defect or delamination was found in the joints of the mockups by the developed ultrasonic test using a flat-type probe with a 10 MHz frequency and a 0.25 inch diameter. High heat flux (HHF) tests were performed at $1.0\;MW/m^2$ heat flux for each mockup using the given conditions, and the results were analyzed by ANSYS-CFX code. For the test criteria, an expected fatigue lifetime about 1,000 cycles was obtained by analysis with ANSYS-mechanical code. Mockups using the interlayers of $1{\mu}mTi/0.5{\mu}mCr/10{\mu}mCu$ and $5{\mu}mTi/10{\mu}mCu$ survived up to 1,100 cycles over the required number of cycles. However, one of the Be tiles in the other two mockups using the $1{\mu}mCr/10{\mu}mCu$ interlayer was detached during the screening test, and others were detached by discharge after 862 cycles. The integrity of the joints using the proposed interlayers was proven by the HHF test, but the other interlayer requires more study before it can be used for the joining of Be to Cu. Moreover, it was confirmed that the measured temperatures agreed well with the analysis temperatures, which were used to estimate the lifetime and that the developed facility showed its capability of the long time operation.