• Title/Summary/Keyword: two-phase system

Search Result 2,653, Processing Time 0.028 seconds

Two-Phase Magnet in the Co/Co2MnSn System

  • Kim, Tae-Wan;Yim, Hye-In;Lee, Hyun-Yong;Lee, Kyoung-Il
    • Journal of Magnetics
    • /
    • v.16 no.1
    • /
    • pp.10-14
    • /
    • 2011
  • This study reports on Co/$Co_2$MnSn two-phase magnets. The Co/$Co_2$MnSn two-phase magnet has Co precipitates in a $Co_2MnSn$ Heusler alloy matrix, in which the two phases are exchange-coupled at the phase boundary. The as-casted Co/$Co_2$MnSn system, which has Co-Mn solid solution precipitates in a $Co_2$MnSn Heusler alloy matrix, showed that the Co solid solution precipitates are crystallographically coherent and there is exchange coupling at the phase boundary. To form pure Co precipitates by removal of Mn solute atoms in Co-Mn solid solution, annealing was carried out 48 hours at $870^{\circ}C$. After annealing, the low $T_c$ and low magnetization phase of the Co-Mn solid solution became a high $T_c$ and high magnetization phase of hexagonal Co.

Partitioning of Lactobacillus helveticus Cells and Lactic Acid in Aqueous PEI/HEC Two-Phase Systems. (수용성 이상계에서의 젖산과 Lactobacillus helveticus세포의 분배특성)

  • 안한군;권윤중
    • Microbiology and Biotechnology Letters
    • /
    • v.26 no.1
    • /
    • pp.55-60
    • /
    • 1998
  • For an ideal extractive bioconversion in aqueous two-phase systems, the product has to be preferentially partitioned into the phase opposite to the one in which the biocatalyst is located. Partitioning behaviors of Lactobacillus helveticus IAM 11090 and lactic acid in aqueous two-phase systems composed a polycation, poly(ethylenimine) (PEI), and an uncharged polymer (hydroxyethyl)cellulose (HEC) were investigated. L. helveticus cells were preferentially partitioned to the HEC-rich top phase while about 85% of lactic acid was partitioned to the PEI-rich bottom phase. These results indicate that extraction of charged, low molecular weight products in an aqueous two-phase systems can be promoted by using an oppositely charged polymer as one of the phase-forming polymer. By the ideal partitioning of the cells and lactic acid, an aqueous PEI/HEC two-phase system can be used as a potential system for the extractive lactic acid fermentation of cheese whey.

  • PDF

Air-Water Two-phase Flow Patterns and Pressure Distributions in a Screw-type Centrifugal Pump

  • Kim, You-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.8
    • /
    • pp.1203-1210
    • /
    • 2004
  • It was reported recently that the pump head degradation near the best efficiency point from single-phase flow to the break-down due to air entrainment became less in a screw-type centrifugal pump than in a general centrifugal pump. In this paper, I carried out internal pressure measurements and visualizations, and investigated the various physical phenomena occurring inside a screw-type centrifugal pump operated in air-water two-phase flow. The results could give some characteristics about the degradation of pump performance on air-water two-phase flow.

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • v.3 no.4
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

MRAS Based Sensorless Control of a Series-Connected Five-Phase Two-Motor Drive System

  • Khan, M. Rizwan;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • v.3 no.2
    • /
    • pp.224-234
    • /
    • 2008
  • Multi-phase machines can be used in variable speed drives. Their applications include electric ship propulsion, 'more-electric aircraft' and traction applications, electric vehicles, and hybrid electric vehicles. Multi-phase machines enable independent control of a few numbers of machines that are connected in series in a particular manner with their supply being fed from a single voltage source inverter(VSI). The idea was first implemented for a five-phase series-connected two-motor drive system, but is now applicable to any number of phases more than or equal to five-phase. The number of series-connected machines is a function of the phase number of VSI. Theoretical and simulation studies have already been reported for number of multi-phase multi-motor drive configurations of series-connection type. Variable speed induction motor drives without mechanical speed sensors at the motor shaft have the attractions of low cost and high reliability. To replace the sensor, information concerning the rotor speed is extracted from measured stator currents and voltages at motor terminals. Open-loop estimators or closed-loop observers are used for this purpose. They differ with respect to accuracy, robustness, and sensitivity against model parameter variations. This paper analyses operation of an MRAS estimator based sensorless control of a vector controlled series-connected two-motor five-phase drive system with current control in the stationary reference frame. Results, obtained with fixed-voltage, fixed-frequency supply, and hysteresis current control are presented for various operating conditions on the basis of simulation results. The purpose of this paper is to report the first ever simulation results on a sensorless control of a five-phase two-motor series-connected drive system. The operating principle is given followed by a description of the sensorless technique.

Experimental study on single- and two-phase flow behaviors within porous particle beds

  • Jong Seok Oh;Sang Mo An;Hwan Yeol Kim;Dong Eok Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.3
    • /
    • pp.1105-1117
    • /
    • 2023
  • In this study, the pressure drop behavior of single- and two-phase flows of air and water through the porous beds filled with uniform and non-uniform sized spherical particles was examined. The pressure drop data in the single-phase flow experiments for the uniform particle beds agreed well with the original Ergun correlation. The results from the two-phase flow experiments were analyzed using numerical results based on three types of previous models. In the experiments for the uniform particle beds, the data on the two-phase pressure drop clearly showed the effect of the flow regime transition with a variation in the gas flow rate under stagnant liquid condition. The numerical analyses indicated that the predictability of the previous models for the experimental data relied mainly on the sub-models of the flow regime transitions and interfacial drag. In the experiments for the non-uniform particle beds, the two-phase pressure loss could be predicted well with numerical calculations based on the effective particle diameter. However, the previous models failed to accurately predict the counter-current flooding limit observed in the experiments. Finally, we propose a relation of falling liquid velocity into the particle bed by gravity to appropriately simulate the CCFL phenomenon.

Four Quadrant Operations of DC Separately-Excited Motor by the Two Phase Chopper System with Combined Output (2상2중 쵸퍼방식에 의한 직류타여자전동기의 4상한동작)

  • 정연택;한경희;김용주;이승환;방이석
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.4
    • /
    • pp.349-356
    • /
    • 1990
  • In order to control DC motors for electric cars by chopper system, four quadrant operations - forward powering, forward regenerative braking, reverse powering, reverse regenerative braking - are needed. For the four quadrant operations, the separately - excited DC motors are used in this study. The conversion of each quadrant operation has been obtained by 1) adopting the two phase chopper system with combined output for the armature control, and 2) the single phase chopper system for the field control.

  • PDF

THE CUPID CODE DEVELOPMENT AND ASSESSMENT STRATEGY

  • Jeong, J.J.;Yoon, H.Y.;Park, I.K.;Cho, H.K.
    • Nuclear Engineering and Technology
    • /
    • v.42 no.6
    • /
    • pp.636-655
    • /
    • 2010
  • A thermal-hydraulic code, named CUPID, has been being developed for the realistic analysis of transient two-phase flows in nuclear reactor components. The CUPID code development was motivated from very practical needs, including the analyses of a downcomer boiling, a two-phase flow mixing in a pool, and a two-phase flow in a direct vessel injection system. The CUPID code adopts a two-fluid, three-field model for two-phase flows, and the governing equations are solved over unstructured grids with a semi-implicit two-step method. This paper presents an overview of the CUPID code development and assessment strategy. It also presents the code couplings with a system code, MARS, and, a three-dimensional reactor kinetics code, MASTER.

Heat Transfer and Pressure Drop Characteristics of Secondary Refrigerants Applying to Indirect Refrigeration System (간접 냉동 시스템용 2차 냉매의 열전달과 압력강하 특성)

  • Oh, Hoo-Kyu;Son, Chang-Hyo;Jo, Hwan;Yi, Wen-Bin;Jeon, Min-Ju
    • Journal of Power System Engineering
    • /
    • v.17 no.4
    • /
    • pp.45-50
    • /
    • 2013
  • This paper presents the comparison of heat transfer and pressure drop of various secondary refrigerants (single-phase and two-phase) in the indirect refrigeration system. The main results were summarized as follows: In case of heat transfer, it is useful to use secondary refrigerants in low evaporating temperature region and the heat transfer coefficient of single-phase is larger than two-phase secondary refrigerants. In case of pressure drop, it is useful to use secondary refrigerants in high evaporating temperature region and the pressure drop of two-phase is smaller than single-phase secondary refrigerant. Also, $CO_2$ is the best useful because pressure drop of $CO_2$ among the secondary refrigerants is the smallest.

Design and Implementation of a Two-Phase Activity Recognition System Using Smartphone's Accelerometers (스마트폰 내장 가속도 센서를 이용한 2단계 행위 인식 시스템의 설계 및 구현)

  • Kim, Jong-Hwan;Kim, In-Cheol
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.2
    • /
    • pp.87-92
    • /
    • 2014
  • In this paper, we present a two-phase activity recognition system using smartphone's accelerometers. To consider the unique temporal pattern of accelerometer data for each activity, our system executes the decision-tree(DT) learning in the first phase, and then, in the second phase, executes the hidden Markov model(HMM) learning based on the sequences of classification results of the first phase classifier. Moreover, to build a robust recognizer for each activity, we trained our system using a large amount of data collected from different users, different positions and orientations of smartphone. Through experiments using 6720 examples collected for 6 different indoor activities, our system showed high performance based on its novel design.