• Title/Summary/Keyword: two-dimensional treatment

Search Result 447, Processing Time 0.025 seconds

Efficacy of Postoperative Radiotherapy Using Modern Techniques in Patients with Retroperitoneal Soft Tissue Sarcoma

  • Kim, Hyun Ju;Koom, Woong Sub;Cho, Jaeho;Kim, Hyo Song;Suh, Chang-Ok
    • Yonsei Medical Journal
    • /
    • v.59 no.9
    • /
    • pp.1049-1056
    • /
    • 2018
  • Purpose: Local recurrence is the most common cause of failure in retroperitoneal soft tissue sarcoma patients after surgical resection. Postoperative radiotherapy (PORT) is infrequently used due to its high complication risk. We investigated the efficacy of PORT using modern techniques in patients with retroperitoneal soft tissue sarcoma. Materials and Methods: Eighty patients, who underwent surgical resection for non-metastatic primary retroperitoneal soft tissue sarcoma at the Yonsei Cancer Center between 1994 and 2015, were retrospectively reviewed. Thirty-eight (47.5%) patients received PORT: three-dimensional conformal radiotherapy in 29 and intensity-modulated radiotherapy in nine patients. Local failure-free survival (LFFS), overall survival (OS), and RT-related toxicities were investigated. Results: Median follow-up was 37.1 months (range, 5.8-207.9). Treatment failure occurred in 47 (58.8%) patients including local recurrence in 33 (41.3%), distant metastasis in eight (10%), and both occurred in six (7.5%) patients. The 2-year and 5-year LFFS rates were 63.9% and 47.9%, respectively. The 2-year and 5-year OS rates were 87.5% and 71.1%. The 5-year LFFS rate was significantly higher in PORT group than in no-PORT group (74.2% vs. 24.3%, p<0.001). In multivariate analysis, PORT was the only independent prognostic factor for LFFS. However, there was no significant correlation between RT dose and LFFS. OS showed no significant difference between the two groups. Grade ${\leq}2$ acute toxicities were observed in 63% of patients, but no acute toxicity ${\geq}$ grade 3 was observed. Conclusion: PORT using modern technique markedly reduced local recurrence in retroperitoneal sarcoma patients, with low toxicity. The optimal RT technique, in terms of RT dose and target volume, should be further investigated.

Effective study of operating parameters on the membrane distillation processes using various materials for seawater desalination

  • Sandid, Abdelfatah Marni;Neharia, Driss;Nehari, Taieb
    • Membrane and Water Treatment
    • /
    • v.13 no.5
    • /
    • pp.235-243
    • /
    • 2022
  • The paper presents the effect of operating temperatures and flow rates on the distillate flux that can be obtained from a hydrophobic membrane having the characteristics: pore size of 0.15 ㎛; thickness of 130 ㎛; and 85% porosity. That membrane in the present investigation could be the direct contact (DCMD) or the air-gap membrane distillation (AGMD). To model numerically the membrane distillation processes, the two-dimensional computational fluid dynamic (CFD) is used for the DCMD and AGMD cases here. In this work, DCMD and AGMD models have been validated with the experimental data using different flows (Parallel and Counter-current flows) in non-steady-state situations. A good agreement is obtained between the present results and those of the experimental data in the literature. The new approach in the present numerical modeling has allowed examining effects of the nature of materials (Polyvinylidene fluoride (PVDF) polymers, copolymers, and blends) used on thermal properties. Moreover, the effect of the area surface of the membrane (0.021 to 3.15 ㎡) is investigated to explore both the laminar and the turbulent flow regimes. The obtained results found that copolymer P(VDF-TrFE) (80/20) is more effective than the other materials of membrane distillation (MD). The mass flux and thermal efficiency reach 193.5 (g/㎡s), and 83.29 % using turbulent flow and an effective area of 3.1 ㎡, respectively. The increase of feed inlet temperatures and its flow rate, with the reduction of cold temperatures and its flow rate are very effective for increasing distillate water flow in MD applications.

True Posterior Communicating Artery Aneurysms with High Risk of Rupture despite Very Small Diameter

  • Shin, Dong Gyu;Park, Jaechan;Kim, Myungsoo;Kim, Byoung-Joon;Shin, Im Hee
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.215-223
    • /
    • 2022
  • Objective : This retrospective study investigated the clinical and angiographic characteristics of ruptured true posterior communicating artery (PCoA) aneurysms in comparison with junctional PCoA aneurysms presenting with a subarachnoid hemorrhage. Methods : The medical records and radiological data of 93 consecutive patients who underwent three-dimensional rotational angiography and surgical or endovascular treatment for a ruptured junctional or true PCoA aneurysm over an 8-year period were examined. Results : The maximum diameter of the ruptured true PCoA aneurysm (n=13, 14.0%) was significantly smaller than that of the ruptured junctional PCoA aneurysms (n=80, 4.45±1.44 vs. 7.68±3.36 mm, p=0.001). In particular, the incidence of very small aneurysms <4 mm was 46.2% (six of 13 patients) in the ruptured true PCoA aneurysm group, yet only 2.5% (two of 80 patients) in the ruptured junctional PCoA aneurysm group. Meanwhile, the diameter of the PCoA was significantly larger in the true PCoA aneurysm group than that in the junctional PCoA aneurysm group (1.90±0.57 vs. 1.15±0.49 mm, p<0.001). In addition, the ipsilateral PCoA/P1 ratio was significantly larger in the true PCoA aneurysm group than that in the group of a junctional PCoA aneurysm (mean PCoA/P1 ratio±standard deviation, 2.67±1.22 vs. 1.14±0.88; p<0.001). No between-group difference was identified for the modified Fisher grade, clinical grade at admission, and 3-month modified Rankin Scale score. Conclusion : A true PCoA aneurysm was found to be associated with a larger PCoA and ruptured at a smaller diameter than a junctional PCoA aneurysm. In particular, the incidence of a ruptured aneurysm with a very small diameter <4 mm was significantly higher among the patients with a true PCoA aneurysm.

Measurements of the Hepatectomy Rate and Regeneration Rate Using Deep Learning in CT Scan of Living Donors (딥러닝을 이용한 CT 영상에서 생체 공여자의 간 절제율 및 재생률 측정)

  • Sae Byeol, Mun;Young Jae, Kim;Won-Suk, Lee;Kwang Gi, Kim
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.434-440
    • /
    • 2022
  • Liver transplantation is a critical used treatment method for patients with end-stage liver disease. The number of cases of living donor liver transplantation is increasing due to the imbalance in needs and supplies for brain-dead organ donation. As a result, the importance of the accuracy of the donor's suitability evaluation is also increasing rapidly. To measure the donor's liver volume accurately is the most important, that is absolutely necessary for the recipient's postoperative progress and the donor's safety. Therefore, we propose liver segmentation in abdominal CT images from pre-operation, POD 7, and POD 63 with a two-dimensional U-Net. In addition, we introduce an algorithm to measure the volume of the segmented liver and measure the hepatectomy rate and regeneration rate of pre-operation, POD 7, and POD 63. The performance for the learning model shows the best results in the images from pre-operation. Each dataset from pre-operation, POD 7, and POD 63 has the DSC of 94.55 ± 9.24%, 88.40 ± 18.01%, and 90.64 ± 14.35%. The mean of the measured liver volumes by trained model are 1423.44 ± 270.17 ml in pre-operation, 842.99 ± 190.95 ml in POD 7, and 1048.32 ± 201.02 ml in POD 63. The donor's hepatectomy rate is an average of 39.68 ± 13.06%, and the regeneration rate in POD 63 is an average of 14.78 ± 14.07%.

A Study on the Probabilistic Analysis Method Considering Spatial Variability of Soil Properties (지반의 공간적 변동성을 고려한 확률론적 해석기법에 관한 연구)

  • Cho, Sung-Eun;Park, Hyung-Choon
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.8
    • /
    • pp.111-123
    • /
    • 2008
  • Geotechnical engineering problems are characterized by many sources of uncertainty. Some of these sources are connected to the uncertainties of soil properties involved in the analysis. In this paper, a numerical procedure for a probabilistic analysis that considers the spatial variability of soil properties is presented to study the response of spatially random soil. The approach integrates a commercial finite difference method and random field theory into the framework of a probabilistic analysis. Two-dimensional non-Gaussian random fields are generated based on a Karhunen-$Lo{\grave{e}}ve$ expansion in a fashion consistent with a specified marginal distribution function and an autocorrelation function. A Monte Carlo simulation is then used to determine the statistical response based on the random fields. A series of analyses were performed to study the effects of uncertainty due to the spatial heterogeneity on the settlement and bearing capacity of a rough strip footing. The simulations provide insight into the application of uncertainty treatment to the geotechnical problem and show the importance of the spatial variability of soil properties with regard to the outcome of a probabilistic assessment.

Assessment of alveolar bone changes in response to minimally invasive periodontal surgery: A cone-beam computed tomographic evaluation

  • Solaleh Shahmirzadi;Taraneh Maghsoodi-Zahedi;Sarang Saadat;Husniye Demirturk Kocasarac;Mehrnoosh Rezvan;Rujuta A. Katkar;Madhu K. Nair
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate 3-dimensional cone-beam computed tomography (CBCT) images of alveolar bone changes in patients who underwent minimally invasive periodontal surgery-namely, the pinhole surgical technique (PST). Materials and Methods: Alveolar bone height was measured and compared on CBCT images of 254 teeth from 23 consecutive patients with Miller class I, II, or III recession who had undergone PST. No patient with active periodontal disease was selected for surgery. Two different methods were used to assess the alveolar bone changes postoperatively. In both methods, the distance between the apex of the tooth and the mid-buccal alveolar crestal bone on pre- and post-surgical CBCT studies was measured. Results: An average alveolar bone gain >0.5 mm following PST was identified using CBCT(P=0.05). None of the demographic variables, including sex, age, and time since surgery, had any significant effect on bone gain during follow-up, which ranged from 8 months to 3 years. Conclusion: PST appears to be a promising treatment modality for recession that results in stable clinical outcomes and may lead to some level of resolution on the bone level. More long-term studies must be done to evaluate the impact of this novel technique on bone remodeling and to assess sustained bone levels within a larger study population.

The Impact of Abdominal Drawing-in Maneuver and Tensor Fasciae Latae-iliotibial Band Self-stretching on Lumbopelvic Kinematics in Individuals With Lumbar Extension Rotation Syndrome

  • One-bin Lim;Oh-yun Kwon;Heon-seock Cynn;Chung-hwi Yi
    • Physical Therapy Korea
    • /
    • v.31 no.1
    • /
    • pp.79-88
    • /
    • 2024
  • Background: The abdominal drawing-in maneuver (ADIM), a method of lumbar stabilization training, is an effective neuromuscular intervention for lumbar instability associated with low back pain (LBP). Objects: The purpose of this study was to compare the effect of a 2-week period of the ADIM and tensor fasciae latae-iliotibial band (TFL-ITB) self-stretching on lumbopelvic rotation angle, lumbopelvic rotation movement onset, TFL-ITB length, and pain intensity during active prone hip lateral rotation. Methods: Twenty-two subjects with lumbar extension rotation syndrome accompanying shortened TFL-ITB (16 males and 6 females) were recruited for this study. The subjects were instructed how to perform ADIM training or ADIM training plus TFL-ITB self-stretching program at home for a 2-week period. A 3-dimensional ultrasonic motion analysis system was used to measure the lumbopelvic rotation angle and lumbopelvic rotation movement onset. An independent t-test was used to determine between-group differences for each outcome measure (lumbopelvic rotation angle, lumbopelvic rotation movement onset, TFL-ITB length, and pain intensity). Results: The results showed that ADIM training plus TFL-ITB self-stretching decreased the lumbopelvic rotation angle, delayed the lumbopelvic rotation movement onset, and elongated the TFL-ITB significantly more than did ADIM training alone. Pain intensity was lower in the ADIM training plus TFL-ITB self-stretching group than the ADIM training alone group; however, the difference was not significant. Conclusion: ADIM training plus TFL-ITB self-stretching performed for a 2-week period at home may be an effective treatment for modifying lumbopelvic motion and reducing LBP.

4-Dimensional dose evaluation using deformable image registration in respiratory gated radiotherapy for lung cancer (폐암의 호흡동조방사선치료 시 변형영상정합을 이용한 4차원 선량평가)

  • Um, Ki Cheon;Yoo, Soon Mi;Yoon, In Ha;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.83-95
    • /
    • 2018
  • Purpose : After planning the Respiratory Gated Radiotherapy for Lung cancer, the movement and volume change of sparing normal structures nearby target are not often considered during dose evaluation. This study carried out 4-D dose evaluation which reflects the movement of normal structures at certain phase of Respiratory Gated Radiotherapy, by using Deformable Image Registration that is well used for Adaptive Radiotherapy. Moreover, the study discussed the need of analysis and established some recommendations, regarding the normal structures's movement and volume change due to Patient's breathing pattern during evaluation of treatment plans. Materials and methods : The subjects were taken from 10 lung cancer patients who received Respiratory Gated Radiotherapy. Using Eclipse(Ver 13.6 Varian, USA), the structures seen in the top phase of CT image was equally set via Propagation or Segmentation Wizard menu, and the structure's movement and volume were analyzed by Center-to Center method. Also, image from each phase and the dose distribution were deformed into top phase CT image, for 4-dimensional dose evaluation, via VELOCITY Program. Also, Using $QUASAR^{TM}$ Phantom(Modus Medical Devices) and $GAFCHROMIC^{TM}$ EBT3 Film(Ashland, USA), verification carried out 4-D dose distribution for 4-D gamma pass rate. Result : The movement of the Inspiration and expiration phase was the most significant in axial direction of right lung, as $0.989{\pm}0.34cm$, and was the least significant in lateral direction of spinal cord, as -0.001 cm. The volume of right lung showed the greatest rate of change as 33.5 %. The maximal and minimal difference in PTV Conformity Index and Homogeneity Index between 3-dimensional dose evaluation and 4-dimensional dose evaluation, was 0.076, 0.021 and 0.011, 0.0 respectfully. The difference of 0.0045~2.76 % was determined in normal structures, using 4-D dose evaluation. 4-D gamma pass rate of every patients passed reference of 95 % gamma pass rate. Conclusion : PTV Conformity Index was more significant in all patients using 4-D dose evaluation, but no significant difference was observed between two dose evaluations for Homogeneity Index. 4-D dose distribution was shown more homogeneous dose compared to 3D dose distribution, by considering the movement from breathing which helps to fill out the PTV margin area. There was difference of 0.004~2.76 % in 4D evaluation of normal structure, and there was significant difference between two evaluation methods in all normal structures, except spinal cord. This study shows that normal structures could be underestimated by 3-D dose evaluation. Therefore, 4-D dose evaluation with Deformable Image Registration will be considered when the dose change is expected in normal structures due to patient's breathing pattern. 4-D dose evaluation with Deformable Image Registration is considered to be a more realistic dose evaluation method by reflecting the movement of normal structures from patient's breathing pattern.

  • PDF

Oxygen Plasma Effect on AlGaN/GaN HEMTs Structure Grown on Si Substrate

  • Seo, Dong Hyeok;Kang, Sung Min;Lee, Dong Wha;Ahn, Du Jin;Park, Hee Bin;Ahn, Youn Jun;Kim, Min Soo;Kim, Yu Kyeong;Lee, Ho Jae;Song, Dong Hun;Kim, Jae Hee;Bae, Jin Su;Cho, Hoon Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.420-420
    • /
    • 2013
  • We investigated oxygen plasma effect on defect states near the interface of AlGaN/GaN High Electron Mobility Transistor (HEMT) structure grown on a silicon substrate. After the plasma treatment, electrical properties were evaluated using a frequency dependant Capacitance-Voltage (C-V) and a temperature dependant C-V measurements, and a deep level transient spectroscopy (DLTS) method to study the change of defect densities. In the depth profile resulted from the temperature dependant C-V, a sudden decrease in the carrier concentration for two-dimensional electron gas (2DEG) nearby 250 K was observed. In C-V measurement, the interface states were improved in case of the oxygen-plasma treated samples, whereas the interface was degraded in case of the nitrogen-plasma treated sample. In the DLTS measurement, it was observed the two kinds of defects well known in AlGaN/GaN structure grown on sapphire substrate, which have the activation energies of 0.15 eV, 0.25 eV below the conduction band. We speculate that this defect state in AlGaN/GaN on the silicon substrate is caused from the decrease in 2DEG's carrier concentrations. We compared the various DLTS signals with filling pulse times to identify the characteristics of the newly found defect. In the filling pulse time range under the 80 us, the activation energies changed as the potential barrier model. On the other hand, in the filling pulse time range above the 80 us, the activation energies changed as the extended potential model. Therefore, we suggest that the found defect in the AlGaN/GaN/Si structure could be the extended defect related with AlGa/N/GaN interface states.

  • PDF

INFLUENCE OF MINIPLATE SHAPES AS SKELETAL ANCHORAGE FOR APPLICATION OF ORTHOPEDIC FORCE: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS (악정형력 적용을 위한 골내 고정원으로서 미니플레이트 형상의 영향: 3차원 유한요소법적 연구)

  • Lee, Nam-Ki;Baek, Seung-Hak;Choi, Dong-Soon;Park, Young-Wook;Kim, Ji-Hyuck;Cha, Bong-Kuen
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.4
    • /
    • pp.345-352
    • /
    • 2008
  • Purpose: This study was performed to evaluate the stress distribution in the bone and the displacement distribution of the miniscrew under orthopedic force with two different types of miniplate design as skeletal anchorage for orthopedic treatment. Materials and methods: Finite element models were made for 6-hole miniplate (0.8mm in thickness), which were designed in two different shapes-one is curvilinear shaped (C plate, Jeil Medical Co., Korea) and another, Y shaped (Y plate), fixed with 3 pieces of miniscrew 2mm-diameter and 6mm-long respectively. A traction force of 4 N was applied in $0^{\circ}$, $30^{\circ}$ and $60^{\circ}$ to imaginary axis connecting two unfixed distalmost holes of the miniplate. Results: The maximum von Mises stress in the bone was much greater in the cortical portion rather than in the cancellous portion. C plate showed greater maximum von Mises stress in the cortical bone than Y plate. The maximum displacement of the miniscrew was greater in C plate than Y plate. The more increased the angle of the applied orthopedic force, the greater maximum von Mises stress in the bone and maximum displacement of the miniscrew. It was observed that in C plate, the von Mises stress in the bone and displacement of the miniscrew were distributed around the distalmost screw-fixed area. Conclusions: The results suggest that Y plate should have the advantage over C plate and in the placement of the miniplate, its imaginary axis should be placed as parallel as possible to the direction of orthopedic force to obtain its primary stability.