• 제목/요약/키워드: two-dimensional isodose curve

검색결과 7건 처리시간 0.026초

GafChromic RTQA Film을 이용한 광역학적 치료용 레이저의 선질 측정 (GafChromic RTQA Film Dosimetry for Laser Beam with Photodynamic Therapy)

  • 이병구;임현수;네클라 커나르
    • 대한의용생체공학회:의공학회지
    • /
    • 제34권2호
    • /
    • pp.73-79
    • /
    • 2013
  • Purpose: The purposes of this study were to measure the dose distribution of Photodynamic therapy(PDT) laser with 635 nm wavelength using GafChromic film. Method & Result: We made each output 300 J by changing mW and sec using the laser beam radiation mode such as C.W(Continuous Wave) mode, Pulse mode and Burst Pulse mode and measured the does at 0 mm and 5 mm of distance from optic fiber catheter end to the film, and at 5 mm distance by changing the angle of the end of the optic fiber catheter as $0^{\circ}$ and $0.5^{\circ}$. The radiated film was scanned and OD(Optical Density) was compared. And two-dimensional isodose curves were obtained and the consistency of shapes was compared. It was confirmed that there was consistency between optic density and the dose radiated on the film when we radiated GafChromic film by changing distance and angle of 300 J output in each radiation mode coordinating mW and sec. Conclusion: In this study, we could identify the stability according to changes in laser beam modes, changes in output according to distance, changes in uniformity according to angle, and beam profiles using GafChromic film, and we could also get two-dimensional isodose curve. It was found that small change in the distance and angle that is made when optic fiber catheter was contacted on the treatment area did not make big effects on the output of beam and the uniformity of dose, and it was also found that GafChromic film could be utilized for the purpose of QA of PDT laser beam.

6MV X-선과 전산화 단층 촬영상을 이용한 뇌하수체 종양 치료계획 (Three Dimensional Dose Planning Using 6MV X-ray and Multiaxial Computed Tomography for Pituitary Adenoma)

  • 이명자;최태진
    • Radiation Oncology Journal
    • /
    • 제3권1호
    • /
    • pp.59-64
    • /
    • 1985
  • Computation of three dimensional dose distribution using CT image and RT plan was applied to a case of pituitary adenoma. Algorithm was based on two dimensional Tissue Maximun Ratio model extended to the third dimension. The resulting isodose curve of transeverse, coronal and sagittal section was demonstrated. This RT plan allows computation of dose distribution in any arbitarily defined plane in addition to conventional cross sectional view.

  • PDF

방사선수술에서 종양 움직임을 재현시킨 움직이는 팬텀을 이용하여 선량 분포의 왜곡에 대한 연구 (Distortion of the Dose Profile in a Three-dimensional Moving Phantom to Simulate Tumor Motion during Image-guided Radiosurgery)

  • 김미숙;하성환;이동한;지영훈;류성렬;조철구;양광모;유형준;서영석;박찬일;김일한;예성준;박재홍;김금배
    • Radiation Oncology Journal
    • /
    • 제25권4호
    • /
    • pp.268-277
    • /
    • 2007
  • 목적: 호흡에 의한 종양의 움직임은 사이버나이프를 이용한 정위적 방사선수술과 같은 정확한 치료에 있어 고려할 만한 방해 요인이다 이 연구에서는 사이버나이프를 이용한 방사선 수술의 Interplay현상을 보고자 팬텀을 움직이게 하고 또한 움직이지 않게 하여 선량 분포의 왜곡을 조사하였다. 대상 및 방법: 팬텀은 $2.5{\times}2.5{\times}5.0$ 인치의 4개의 직육면체로 구성된 폴리에틸렌과 2장의 Gafchromic 필름으로 구성되었다. 치료 계획은 20, 30, 40, 50 mm지름을 가진 구를 가상하여 사이버나이프 치료기를 이용하여 104개의 빔 방향과 single center mode의 치료 계획 하에 총 30 Gy를 조사하였다. 특별히 제작된 로봇은 팬텀을 좌우, 전후, 두미쪽으로 각각 5, 10, 20 mm 움직이도록 고안되었다. 필름의 optical density을 이용하여 정적인 상태의 팬텀과 로봇에 의해 움직일 때의 팬텀의 선량 분포를 구하였다. 결 과: 정적인 상태에서 종양을 모두 포함할 수 있는 최소의 등선량은 20 mm 종양의 경우 80%, 30 mm에 84%, 40 mm에 83%이며 50 mm 종양에 80%였다. 정적인 상태와 움직일 때의 팬텀 사이에서 발생한 선량 분포의 차이(gap)는 20 mm 종양에서 두미방향으로 각각 3.2, 3.3 cm이며 오른쪽 3.5 mm, 왼쪽 1.1 mm였다. 30 mm 종양의 경우는 각각 3.9, 4.2, 2.8과 0 mm였고 40 mm 종양은 각각 4.0, 4.8, 1.1, 0 mm였다. 50 mm 종양의 경우 각각 3.9, 3.9, 0.0 mm였다. 결 론: 20 mm의 적은 종양을 치료할 때 80%의 등선량이 계획되더라도 움직이는 실제 치료에 있어 종양 움직임을 보완하기 위하여 60% 등선량으로 처방할 필요가 있다. 이때 두 등선량 곡선의 차이는 5 mm정도이다. 또한 30, 40과 50 mm의 종양에서는 움직임을 보완하기 위하여 등선량 곡선을 70%정도로 처방할 필요가 있다. 이때의 차이도 약 5 mm 미만이다. 이는 사이버나이프를 이용한 방사선수술 시 움직임 그 차체 보다 여유폭을 적게 줄 수 있다는 의미이며 이는 일반 방사선치료와 다른 점이라 할 수 있다.

Bragg-curve simulation of carbon-ion beams for particle-therapy applications: A study with the GEANT4 toolkit

  • Hamad, Morad Kh.
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2767-2773
    • /
    • 2021
  • We used the GEANT4 Monte Carlo MC Toolkit to simulate carbon ion beams incident on water, tissue, and bone, taking into account nuclear fragmentation reactions. Upon increasing the energy of the primary beam, the position of the Bragg-Peak transfers to a location deeper inside the phantom. For different materials, the peak is located at a shallower depth along the beam direction and becomes sharper with increasing electron density NZ. Subsequently, the generated depth dose of the Bragg curve is then benchmarked with experimental data from GSI in Germany. The results exhibit a reasonable correlation with GSI experimental data with an accuracy of between 0.02 and 0.08 cm, thus establishing the basis to adopt MC in heavy-ion treatment planning. The Kolmogorov-Smirnov K-S test further ascertained from a statistical point of view that the simulation data matched the experimentally measured data very well. The two-dimensional isodose contours at the entrance were compared to those around the peak position and in the tail region beyond the peak, showing that bone produces more dose, in comparison to both water and tissue, due to secondary doses. In the water, the results show that the maximum energy deposited per fragment is mainly attributed to secondary carbon ions, followed by secondary boron and beryllium. Furthermore, the number of protons produced is the highest, thus making the maximum contribution to the total dose deposition in the tail region. Finally, the associated spectra of neutrons and photons were analyzed. The mean neutron energy value was found to be 16.29 MeV, and 1.03 MeV for the secondary gamma. However, the neutron dose was found to be negligible as compared to the total dose due to their longer range.

입체적횡다증회전조사를 병합한 방사선수술의 새로운 접근 : 포톤나이프 (A New Approach with Combined Stereotactic Trans-multiarc Beams for Radiosurgery Based on the Linear Accelerator : Photon Knife)

  • 최태진;김진희;김옥배
    • Radiation Oncology Journal
    • /
    • 제14권2호
    • /
    • pp.149-158
    • /
    • 1996
  • 목적 : 선형가속기의 광자선을 이용한 두개내 소병변의 방사선수술에서 다중회전조사와 횡다중회전조사를 병용한 방사선 수술방법을 개발하고, 컴퓨터단층영상을 재구성한 방사선수술계획을 통해 선량분포를 비교하여 병변이외 정상조직의 선량을 줄이기 위한 선량변수를 구하였다. 대상 및 방법 : 선형가속기 6 MV 광자선을 이용하여 치료대 각과 선원지지체 회전 및 환자체위변위를 이용한 입체적 다중 및 횡다중회전조사를 조사하여 선량분포를 비교하였다. 입체적 선량분포와 횡단면, 시상면 및 관상면 치료대 영상재구성의 선량분포는 본 대학에서 개발한 방사선수술기구 및 소프트웨어 (Photon Knife)를 통해 이루어졌다. 입체적 다중회전조사에 의해 얻은 선량은 치료대 각이 20, 50, 120, 160 도, 각각의 선원지지체 회전각은 20-160도이며, 다중회전조사의 치료대각 30, 150도와 횡다중회전조사의 치료대각 30, 150도에 선원 회전각 20-160도를 입체조사하여 비교하였다. 결과 : 선형가속기를 이용한 방사선수술선량분포는 동일 콜리메이터에서도 치료대와 선원지지체 각에 따라 크게 변하였다. 입체횡다중회전조사를 시행한 경우 표적을 중심으로 전후방향의 선량분포는 다중회전조사만을 사용한 경우보다 선량기울기가 증가하여 정상뇌조직의 손상을 더 감소시킬 수 있음을 알 수 있었으며, 병변주위의 치명장기 위치에 따라 방사선 회전 방향을 적절히 정할 수 있다. 방사선수술의 입체선량과 주위 장기 및 표적의 On-Target 입체화는 방사선수술의 정확성, 복수개의 표적중심결정과 주위정상장기의 선량포함범위를 비교적 정확하게 보여줌을 알 수 있다. 결론 : 방사선수술선량계획의 입체화는 선량과 표적 및 주위장기의 선량범위를 입체적으로 정할 뿐만 아니라, 표적의 모양이 불규칙형일 때는 복수개의 표적중심결정에 필수적임을 알 수 있었다. 다중회전조사와 횡다중회전조사를 병합한 방사선수술은 표적주위의 치명정상장기의 손상을 줄이기 위해 총회전각의 변화없이 치명장기에 도달될 선량을 줄일 수 있으며, 25 mm 직경의 콜리메이터를 사용한 선량분포는 $80-50\%$의 간격이 $1.1\~3.0 mm$, $90\~50\%$$2.0\~3.0mm$를 나타내었다.

  • PDF

$GafChromic^{(R)}$ EBT2 Film Dosimetry를 위한 품질 관리용 초기 프로그램 개발 (Development of Preliminary Quality Assurance Software for $GafChromic^{(R)}$ EBT2 Film Dosimetry)

  • 박지연;이정우;최경식;홍세미;박병문;배용기;정원균;서태석
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.113-119
    • /
    • 2010
  • GafChromic EBT2 필름 dosimetry에 필요한 품질 관리용 소프트웨어를 개발하였다. 개발한 프로그램에서는 EBT2 필름특성에 맞게 붉은색, 초록색, 파란색 및 회색 채널에 따른 필름 교정이 가능하도록 하였다. 또한 평판형 스캐너의 빛의 산란 효과나 필름 내 방사선에 반응하는 물질(active layer)의 두께 차이가 선량 검증에 미치는 영향을 평가할 수 있도록 하였다. EBT2 필름을 이용한 측정 결과는 방사선 치료계획 시스템, ECLIPSE 또는 2차원 이온 전리함 배열의 선량 값과 비교할 수 있다. 개발한 소프트웨어를 이용한 GafChromic EBT2 필름의 선량 검증은 파일 입력, 잡음 제거, 배경 보정(background) 및 반응 물질 보정(active layer correction), 선량 계산 및 평가 단계를 통해서 이루어진다. 절대적 또는 상대적 배경 보정 방법을 선택적으로 적용할 수 있으며 필름 교정 결과 및 교정 곡선에 대한 적합식(fitting equation)은 결과 파일로 출력할 수 있다. 선량 행렬의 화소 크기 조정을 위한 보간법, 대화식 영상 이동 및 회전 기능을 이용하여 선량 행렬 간 구조적 위치를 일치시킨 후, 빔 측면도(beam profile) 및 등선량곡선(isodose curve)을 비교할 수 있다. 또한 거리 및 선량 차이에 대한 허용값을 적용하여 gamma index 및 gamma histogram을 이용한 선량 분석이 가능하다. 60도 동적 쐐기 조사면과 전립선 세기조절방사선치료의 조사면을 이용하여 개발한 소프트웨어의 기초 성능 평가를 수행하였을 때, 동적 쐐기 조사면에서 ECLIPSE와 EBT2 필름 간 절대적 빔 측면도는 3% 오차 범위 내에서 일치하였다. EBT2 필름을 이용한 두 종류의 선량 검증 모두, 99% 이상의 영역이 3 mm, 3%의 gamma index의 평가 기준을 만족하였다. 개발한 선량 검증용 소프트웨어를 이용하여 주기적으로 수행되는 일반적인 품질관리뿐만 아니라 빔의 세기가 조절된 복잡한 조사면의 품질관리에도 활용할 수 있으며, Radiochromic 필름을 이용한 선량 평가에 필요한 유용한 분석 툴을 제공할 수 있다.

구동팬텀 시스템에 의한 움직이는 장기의 선량분포 분석 (Analysis of the Dose Distribution of Moving Organ using a Moving Phantom System)

  • 김연래;박병문;배용기;강민영;이귀원;방동완
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.81-87
    • /
    • 2006
  • 목 적: 움직이는 장기의 방사선치료시에 움직임을 고려한 선량분포의 연구가 많이 이루어지지 않았고, 정적인 상태로서의 선량분포가 고려된 치료 및 연구가 이루어졌다. 그래서 본 연구는 구동팬텀 시스템을 이용하여 움직이는 장기의 선량분포 계측을 시행하였다. 이 연구의 목적은 호흡에 따른 선량분포의 변화가 어떻게 일어나는지에 대한 실험적 계측에 대한 평가이다. 재료 및 방법: 호흡에 의한 움직이는 장기의 선량분포 측정을 위해서 다목적 팬텀과 구동팬텀을 고안 하였다. 다목적 팬텀의 구성은 아크릴과 코르크를 사용하였고, 아크릴의 밀도는 $1.14g/cm^3$이고 코르크는 $0.32g/cm^3$이다. 아크릴은 정상조직을 표현하기 위해 사용되었고, 코르크는 폐를 묘사하기 위해 제작 되었다. 측정용 필름은 가프크로믹 필름과 EDR2필름을 사용하였다. 구동팬텀 시스템은 상하좌우 2차원적인 움직임을 하도록 설계되었으나 본 실험은 1차원적인 움직임만으로 구동하여 측정하였다. 결 과: 코르크 팬텀에서 측정된 선량분포가 아크릴에서 측정된 선량분포보다 반음영이 크게 나타났다. 가프크로믹 필름으로 측정된 선량분포는 선량분포에 따른 광학농도가 낮기 때문에 분포곡선이 평탄하지 않았다. 내부장기의 움직임이 증가함에 따라 선량분포에서 반음영, 평탄도, 대칭도가 점점 증가하였다. 모든 가프크로믹 필름으로 측정된 선량분포는 EDR2필름으로 측정된 필름보다 평탄도나 대칭도가 좋지 않았지만 반음영은 비슷하게 분포되었다. 결 론: 가프크로믹 필름은 현상이 필요 없기 때문에 사용하기 편하고, 조그만 크기로도 쉽게 잘라서 사용할 수 있다. 또한 많은 양의 방사선을 조사할 수 있는 장점이 있다. 그러나 선량에 따른 광학농도의 변화가 작기 때문에 측정 시에 선량분포에 평탄도가 좋지 않다. 움직이는 장기의 방사선치료시 다목적 팬텀과 구동팬텀을 이용하여 질보정이 이루어진다면 치료효과를 향상시킬 것이라 사료된다.

  • PDF