• Title/Summary/Keyword: two mass system

Search Result 1,446, Processing Time 0.027 seconds

An Improved Weak-Lensing Analysis of the Galaxy Cluster ACT-CL J0102-4915 with New Wide-Field HST Imaging Data

  • Kim, Jinhyub;Jee, Myungkook James
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.29.5-30
    • /
    • 2020
  • We present an improved weak-lensing (WL) study of the high-z (z=0.87) merging galaxy cluster ACT-CL J0102-4915 ("El Gordo"), the most massive system known to date at z > 0.6. El Gordo has been known to be an exceptionally massive and rare cluster for its redshift in the current ΛCDM cosmology. Previous multi-wavelength studies have also found that the cluster might be undergoing a merging event showing two distinctive mass clumps and radio relics. The previous WL study revealed a clear bimodal mass structure and found that the entire system is indeed massive (M200a = (3.13 ± 0.56) × 1015 Msun). This mass estimate, however, was obtained by extrapolation because the previous HST observation did not extend out to the virial radius of the cluster. In this work, we determine a more accurate mass estimate of the cluster using WL analysis utilizing a new set of WFC3/IR and wide-field ACS observations. While confirming the previous bimodal mass structure, we find that the new data yield a ~20% lower mass for the entire system (M200a = (2.37 ± 0.28) × 1015 Msun). We also discuss the rarity of the cluster in the ΛCDM paradigm and suggest an updated merging scenario based on our new measurement.

  • PDF

PERIOD VARIATIONS OF RT PERSEI

  • Kim, Chun-Hwey
    • Journal of Astronomy and Space Sciences
    • /
    • v.12 no.2
    • /
    • pp.179-195
    • /
    • 1995
  • RT Per has been known as a close binary of which the orbital period has unpredictably varied so far. Although there are no agreements with the working mechanism for the changes of the period, two interpretations have been suggested and waiting for to be tested: 1) light-time effects due to the unseen 3rd and 4rd bodies (Panchatsaram 1981), 2) Abrupt period-changes, due to internal variations of the system (e.g. mass transfer or mass loss) superimposing to the light-time effect by a 3rd body (Frieboes-Conde & Herczeg 1973). In the point of view that the former interprepation models could predict the behavior of the changes of the orbital period theoretically, we checked whether the recent observed times of minimum lights follow the perdictions by the first model or not. We confirmed that the observed times of minimum lights have followed the variations calculated by the light-times effects due to the 3rd and 4rd bodies suggested by Panchatsatam. In this paper a total of 626 times of minimum lights were reanalyzed in terms of the light-time effects by the 3rd and 4rd bodies. We concluded that the eclipsing pair in SVCam system moves in an elliptic orbit about center of mass of the triple system with a period of about $42.^y2$, while the mass center of the triplet is in light-time orbit about the center of mass of the quadruple system with a period of $120^y$. The mean masses deduced for the 3rd and 4rd bodies were $0.89m_\odot$ and $0.82m_\odot$, respectively.

  • PDF

Design of Control Algorithm for Mass Driving Anti-Rolling System Considering Control Input Constraint (제어 입력포화를 고려한 횡동요 저감장치용 제어알고리듬 설계)

  • Moon, Seok-Jun;Lim, Chae-Wook;Lee, Hae-Jong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.42 no.6 s.144
    • /
    • pp.566-574
    • /
    • 2005
  • Reduction of a ship's rolling is the most important performance requirement for improving the safety of the crew on board and preventing damage to cargos as well as improving the comfort of the ride. A mass driving anti-rolling system (MO-ARS) might be one candidate of several systems against the ship's rolling. As the movable range of the mass on the ship is finite, the control system must include restriction on the mass position to protect the device and the ship. This restriction usually causes windup phenomenon and control performance is deteriorated seriously. Two control algorithms, anti-windup control and saturated sliding mode control, are studied in this paper. Control performance and robustness problem are checked out by numerical simulations.

An Experimental Study on the Mass Release for a Hot Leg Break LBLOCA in Post Blowdown

  • Hong, Soon-Joon;Park, Goon-Cherl
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.405-410
    • /
    • 1996
  • New methodology for mass and energy release assessment in LBLOCA post blowdown is needed and, first of all, the phenomenologically improved and quantitative assessments through experiment are essential. For tile experiment of a hot leg break LBLOCA in post blowdown, the test facility was set and its feature is that tile broken hot leg has two broken sections in the tore side and in the SG side respectively and a separation valve between the two in order to measure the release rate dividedly. Specially it was focused on whether the mass release through the SG side broken section happened or not. The mass release through the core side broken section is dependent on tile safety injection flow and that through the SG side broken section varies depending on several factors. The principal factor is the primary system pressure and the subfactors such as SI flow rate, SI temperature and initial primary pressure, may contribute, too.

  • PDF

Efficient Vibration Control Approach of Two Identical Adjacent Structures (동일한 인접구조물의 효율적 진동제어방안)

  • Ok, Seung-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.3
    • /
    • pp.56-63
    • /
    • 2014
  • This study proposes a new control approach for efficient vibration suppression of two identical adjacent structures. The conventional control approach of two adjacent structures is to interconnect the two structures with passive, semi-active or active control devices. However, when the two adjacent structures are identical to each other, their dynamical behaviors such as frequency and damping properties are also the same. In this case, the interconnected control devices cannot exhibit the dissipative control forces on the both structures as expected since the relative displacements and velocities of the devices become close to zero. In other words, the interconnection method does not work for the twin structures as enough as expected. In order to solve this problem, we propose several new control approaches to effectively and efficiently reduce the identically-fluctuating responses of the adjacent structures with minimum control efforts. In order to demonstrate the proposed control systems, the proposed several control systems are optimally designed and their control performances are compared with that of the conventional optimal control system where each TMD(tuned mass damper) is installed in each structure for independent control purpose. The simulated results show that one of the proposed control systems(System 04) is able to guarantee enhanced control performance compared with the conventional system.

Mass transfer with Asymmetric Light Curve of Contact and Near-Contact Binaries

  • Rittipruk, Pakakaew;Kang, Young-Woon
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.50.1-50.1
    • /
    • 2010
  • We have analyzed times of minima for of 6 binary systems. Three binary systems show period decrease at rate $3.19{\times}10-5$ yr -1 for SV Cen, $1.35{\times}10-7$ yr -1 for RT Scl and $1.14{\times}10-7$ yr -1 for AD Phe. Two systems show period increase $5.696{\times}10-8$ yr -1 for SX Aur and $6.93{\times}10-8$ yr -1 for GO Cyg. One system shows cyclic period variation. We estimated the mass transfer rate for 5 binary systems. Four systems show asymmetric light curves. Two asymmetric light curves (SV Cen and RT Scl) are due to hot spot caused by mass transfer. And two asymmetric light curves (AD Phe and TY Boo) are due to cool spot caused by magnetic activities on the cooler component. We also obtain absolute dimensions from photometric solution and spectroscopic solution by analyzing their light curves and radial velocity curves, which are collected from literatures, using 2007 version Wilson and Deviney computer code.

  • PDF

A STUDY OF LYNDS 1251 DARK CLOUD: I. STRUCTURE AND KINEMATICS

  • LEE YOUNGUNG
    • Journal of The Korean Astronomical Society
    • /
    • v.27 no.2
    • /
    • pp.159-175
    • /
    • 1994
  • We have mapped the whole extent of a dark cloud Lynds 1251 in the emission of the J=1-0 transitions of $^{12}CO\;and\;^{13}CO$ using FCRAO's fifteen-beam array receiver in high angular resolution of 50'. We have derived physical parameters of L1251, discussed three different mass estimate techniques, and obtained a large range of mass, 600 to $6,000M_\bigodot$, depending on the techniques. The factor of 10 discrepancy between the virial and LTE masses is much larger than expected based on the uncertainties residing in two methods. The large virial mass may reflect the fact that L1251 is not gravitationally bound system as in the case of dark clouds in solar neighborhood. Two outflows are affecting the dynamics of cloud significantly but not enough to reshape the whole extent of the cloud. The small cloud, 'Stripe', which is apparently connected with main cloud, is not likely to be associated with L1251. The velocity gradient composed on this small cloud may be driven by other unknown sources. It is found that L1251 cloud itself is very quiescent except the two bipolar outflow regions.

  • PDF

Flow Pattern and Pressure Drop of Pure Refrigerants and Their Mixture in Horizontal Tube

  • Lim, Tae-Woo
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2289-2295
    • /
    • 2005
  • Two-Phase flow pattern and pressure drop data were obtained for pure refrigerants R134a and R123 and their mixtures as test fluids in a horizontal tube. The flow pattern is observed through tubular sight glasses located at inlet and outlet of the test section. The flow map of Baker developed for air-water two-phase flow at atmospheric pressure failed to predict the observed flow patterns at the higher value of the mass velocity used in the present study. The map of Kattan et al. predicted the data well over the entire region of mass velocity selected in the present study. The measured pressure drop increased with an increase in vapor quality and mass velocity. A new two-phase multiplier was developed from a dimensional analysis of the frictional pressure drop data measured in the present experiment. This new multiplier was found successfully to correlate the frictional pressure drop.

Convective Boiling Two-phase Flow in Trapezoidal Microchannels : Part 1-Pressure Drop Characteristics (사다리꼴 미세유로의 대류비등 2상유동 : 1부-압력강하 특성)

  • Kim, Byong-Joo;Kim, Geon-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.87-94
    • /
    • 2011
  • Characteristics of two-phase pressure drop in microchannels were investigated experimentally. The microchannels consisted of 9 parallel trapezoidal channels with each channel having $205\;{\mu}m$ of bottom width, $800\;{\mu}m$ of depth, $3.6^{\circ}$ of sidewall angle, and 7 cm of length. Pressure drops in convective boiling of Refrigerant 113 were measured in the range of inlet pressure 105~195 kPa, mass velocity $150{\sim}920\;kg/m^2s$, and heat flux $10{\sim}100\;kW/m^2$. The total pressure drop generally increased with increasing mass velocity and/or heat flux. Two-phase frictional pressure drop across the microchannels increased rapidly with exit quality and showed bigger gradient at higher mass velocity. A critical review of correlations in the literature suggested that existing correlations were not able to match the experimental results obtained for two-phase pressure drop associated with convective boiling in microchannels. A new correlation suitable for predicting two-phase friction multiplier was developed based on the separated flow model and showed good agreement with the experimental data.

Control of flutter of suspension bridge deck using TMD

  • Pourzeynali, Saeid;Datta, T.K.
    • Wind and Structures
    • /
    • v.5 no.5
    • /
    • pp.407-422
    • /
    • 2002
  • Passive control of the flutter condition of suspension bridges using a combined vertical and torsional tuned mass damper (TMD) system is presented. The proposed TMD system has two degrees of freedom, which are tuned close to the frequencies corresponding to vertical and torsional symmetric modes of the bridge which get coupled during flutter. The bridge-TMD system is analyzed for finding critical wind speed for flutter using a finite element approach. Thomas Suspension Bridge is analyzed as an illustrative example. The effectiveness of the TMD system in increasing the critical flutter speed of the bridge is investigated through a parametric study. The results of the parametric study led to the optimization of some important parameters such as mass ratio, TMD damping ratio, tuning frequency, and number of TMD systems which provide maximum critical flutter wind speed of the suspension bridge.