• 제목/요약/키워드: two fluid

검색결과 4,078건 처리시간 0.034초

자발성 지주막하출혈 후 발생하는 수두증에 대한 단락술의 필요성 및 예후에 관한 분석 - 뇌실외배액술의 기간, 일일배액량 및 총배액량과 예후관계 - (The Analysis of the Need Rate of Shunt and the Outcome in Hydrocephalus Following SAH - Relationship between the Outcome and the Duration, Daily and Total Amount of CSF Drainage at EVD -)

  • 이원창;최창화
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권sup1호
    • /
    • pp.99-107
    • /
    • 2001
  • Objective : Hydrocephalus and vasospasm are the common complications following subarachnoid hemorrhage (SAH). In spite of development of perioperative management and operative technique, hydrocephalus cause neurological deficit and poor prognosis. Usually CSF drainage procedure(external ventricular drainage(EVD) or shunt) is needed in hydrocephalus following SAH. The aim of this study was to investigate whether the need for shunting and the outcome after shunting in hydrocephaus following SAH can be related to the duration, daily and total amount of cerebrospinal fluid(CSF) drainage at EVD. Material and Method : IVH is one of several factors which cause hydrocephalus. In this retrospective study, firstly we investigated the incidence of IVH in total cases and frequency of IVH according to aneurysmal site and then prognosis of IVH following SAH. Among 629 patients with SAH, hydrocephalus was diagnosed by CT scan and symptoms. And then those 102 hydrocephalus following SAH were divided into two groups which were hydrocephalus with IVH group and without IVH group. In these two groups, we investigated and compared the incidence of hydrocephalus in all case, frequency of hydrocephalus according to aneurysmal site, the outcome according to H-H grade on admission and the need rate of shunt, etc. Of those hydrocephalus, 100 EVD procedures were done. The duration, daily and total amount of CSF drainage at EVD were investigated. Fifty cases expired during EVD was excluded. We analyzed whether the need rate of shunt and the final outcome after shunting can be related to IVH, the duration and daily and total amount of CSF drainage. Result : The incidence of hydrocephalus following SAH was 20%(with IVH group ; 64%, without IVH group ; 11%). As H-H grade on admission was better, the outcome of hydrocephalus was also better. The mortality rate of hydrocephalus with IVH was 64% which was higher than 40% that of hydrocephalus without IVH. The need rate of shunt in all cases of hydrocephalus following SAH was 20%, but those with IVH group excluding expired patients before shunt was 40%. This was very similar to 41% of the need rate of shunt in hydrocephalus without IVH. The total amount of CSF drainage was statistically related to the need rate of shunt(total amount : need rate of shunt/<1000cc : 15%, 1000-2000cc : 40%, >2000cc : 50%). The duration and daily amount of CSF drainage were not statistically related to the need rate of shunt, but as daily amount of CSF drainage was more and duration was longer, the need rate of shunt was increased(daily amount : need rate of shunt /<100cc : 16%, 100-200cc : 25%, >200cc : 40%//duration : need rate of shunt/<1week : 8%, 1-2weeks : 30%, >2weeks : 47%), and also the final outcome after shunting was poor. Especially the total amount of CSF drainage was significant related to the final outcome after shunting(total amount : GOS/<1000cc : I&II(3/4), 1000-2000cc : II(2/4), III(2/4), >2000cc : III&IV(6/7)). Conclusion : This study revealed that the incidence and mortality rate of hydrocephalus following SAH were influenced by IVH. So SAH associated IVH has the higher incidence of hydrocephalus and poor outcome. As the CSF drainage amount was more and duration of drainage was longer, the need rate of shunt was increased and the final outcome after shunting was poor. Especially the total amount of CSF drainage were strongly related to the need rate of shunt and the outcome after shunting.

  • PDF

본류와 지류의 수온 차에 의한 합류부 혼합 양상 분석 (Analysis of the mixing effect of the confluence by the difference in water temperature between the main stream and the tributary)

  • 안설하;이창현;김경동;김동수;류시완;김영도
    • 한국수자원학회논문집
    • /
    • 제56권2호
    • /
    • pp.103-113
    • /
    • 2023
  • 하천 합류부는 서로 다른 지형학적 특성과 수리학적 특성을 가지는 두 개의 하천이 하나로 합쳐지는 구간으로 급격한 흐름의 변화 및 퇴적물의 유입과 수리학적 지형변화가 발생하는 구간이다. 합류부 구간에서는 물질의 종류 또는 온도 차로 유체의 흐름이 밀도 차이로 발생하게 되는데 이것을 밀도류라고 한다. 밀도 차이에 의해 성층이 생긴 수체혼합거동을 파악하기 위해서는 본류 및 지류의 일정 구간을 포함하는 합류부 구간에 대한 정밀한 계측 및 관찰이 필요하다. 이러한 수체 혼합에 대한 종합적인 분석은 유속장 및 유량 정보를 취득하여 파악할 수 있지만, 성층류가 흐르는 하천의 서로 상이한 물리적 특성과 수질특성을 가지는 수체의 혼합양상 및 그에 따른 물질혼합양상을 파악하는데 한계가 있다. 따라서 본 연구에서는 합류부 구간에서의 수온 분포를 통하여 밀도류를 파악하고자 한다. 하천의 광범위한 데이터 중 연직 자료와 수표면 자료를 취득하였고, 이를 통해 합류부의 성층현상을 확인하고자 하였다. ADCP를 보트 측면에 설치하여 저속운행으로 수리량을 측정하는 방식과 YSI를 이용해 측선설치 없이 측선 선정 후 보트를 이용하여 흐름에 직각인 방향으로 이동하며 실시간 농도를 측정하는 방식으로 얻은 연직자료 중 수온, 전도도(Conductivity) 등의 직독식 센서 데이터 값을 사용하여 수온 차에 따른 수체혼합 패턴을 분석하여 합류부의 혼합양상을 분석하고자 하였다. 본 연구는 기존 수질 측정의 한계였던 1차원적인 측정결과가 나타내는 분석결과를 2차원적으로 보완이 가능하며, 비교 분석한 결과를 토대로 밀도류에 따른 혼합양상 결과가 지니는 혼합패턴을 분석한다면 향후 하천 하류구간의 취수 시스템에 많은 도움을 줄 뿐만 아니라 합류부 구간의 혼합패턴에 따라 수층 내 성층구간의 현황조사와 하천 합류부의 혼합특성 파악하여 합류구간의 수질 관리방안이나 수체 흐름특성을 제시할 수 있을 것으로 사료된다.

소아 농흉 원인균에 대한 다기관 연구(1999. 9-2004. 8) (The causative organisms of pediatric empyema in Korea)

  • 염혜영;김우겸;김진택;김현희;나영호;박용민;손명현;안강모;이수영;홍수종;이혜란
    • Clinical and Experimental Pediatrics
    • /
    • 제50권1호
    • /
    • pp.33-39
    • /
    • 2007
  • 목 적 : 농흉은 세균성 폐렴의 주요 합병증으로 소아과 영역의 중요 질환이며 새로운 백신의 개발과 광범위 항생제의 사용으로 농흉의 임상 양상과 원인균주의 변화가 예상된다. 본 연구는 최근 5년간의 전국의 2, 3차 병원에서 농흉으로 진단, 치료를 받은 환아들을 대상으로 그 임상 양상과 원인균주에 대한 분석을 하여 보고하는 바이다. 방 법 : 1999.9.1-2004.8.31까지 만 5년간 2, 3차 병원에 내원한 소아연령의 농흉 환자들의 임상기록을 검토하여 임상 양상 및 검사실 소견, 치료 및 경과를 후향적으로 조사하였다. 결 과 : 전국 35개 2, 3차 병원의 122명의 환자가 선정되었다. 이중 1세에서 3세미만이 가장 많아 48명(39.3%)였다. 주증상은 기침과 발열, 호흡곤란, 기면, 흉통, 복통, 구토, 과민, 복부 팽창, 청색증 등의 순서로 관찰되었다. 흉강 천자 결과 육안으로 보았을 때 황색을 보인 경우가 58례(47.5%)로 가장 많았다. 흉막액의 백혈구 수는 평균 $30,365.8{\pm}64,073.0/{\mu}g$였고 단백량은 $522.3{\pm}1,582.3g/dL$였다. 전체 환자 중 80례(65.6%)에서 원인균이 배양되었다. 흉막액 배양에서 균이 동정된 증례 중 45명(36.9%)에서 S. pneumoniae가 검출되었고 Group A Streptococcus, coagulase negative staphylococcus, S. aureus 순서로 동정되었다. 혈액배양에서 양성을 보인 경우는 15례(12.3%)로 S. pneumoniae, S. aureus, coagulase negative staphylococcus, H. influenzae type b, Enterobacter cloacae의 순서로 나타났다. 107명(87.7%)의 환자에서 폐렴이 동반되었다. 그 외에 기흉, 패혈증, 뇌성마비, 무기폐, hyper IgE 증후군, X-linked agammaglobulinemia, 기관식도누출관, 철분 결핍성 빈혈, 유미흉, 폐쇄 항문 등이 동반되었다. 좌우측을 명시한 단순 흉부 방사선 소견을 조사한 결과 좌측의 병변이 42례(34.4%), 우측의 병변이 75례(61.5%)였고 양측 모두에 농흉이 있던 경우가 1례였다. 전 환자에서 항생제를 투여하였고 75례(61.5%)에서 폐쇄성 배농을 시행하였다. 이 중 8례는 흉관을 통해 urokinase를 투여하였다. 27례(22.1%)에서는 항생제만을 투여하였고 16례(13.1%)에서는 개방성 배농을 시행하고 4례(3.3%)에서 겉질제거를 시행하였다. 투여한 항생제는 vancomycin 46례(36.6%), cefotaxime 44례(36.1%), ampicillin with clavulinic acid 38례(31.1%), ceftriaxone 36례(29.5%), teicoplanin 6례(4.9%)의 순서로 사용되었다. 평균 입원기간은 $28.6{\pm}15.3$일 이었다. 21-30일간 입원한 환자가 37례(30.3%)로 가장 많았다. 사망 1례는 Hyper IgE 증후군을 가진 9세 남아로서 우측 페의 농흉이 있던 증례로 폐출혈과 호흡부전으로 사망하였다. 결 론 : 1999. 9. 1-2004. 8. 31까지 만 5년간 2, 3차 병원에 내원한의 122명의 소아 농흉 환자를 대상으로 임상양상을 분석한 결과 1985년 이전의 국내 보고와 달리 1세에서 3세 미만의 연령에서 호발하고 주원인균은 S. pneumoniae, Group A Streptococcus, coagulase negative staphylococcus, S. aureus 순서로 동정되었다. 항생제로는 vancomycin과 2, 3세대 세팔로스파린을 가장 많이 투여하였으며 폐쇄성 배농을 주로 시행하고 일부에서 개방성 배농과 fibrinolysis를 시행하였다. 폐구균 백신의 사용과 항생제 내성균의 출현에 따른 원인균주의 변화 및 항생제 감수성에 대한 지속적 연구가 요구된다.

위증에 대한 동서의학적(東西醫學的) 고찰(考察) (The Literatual Study on the Wea symptom in the View of Western and Oriental Medicine)

  • 김용성;김철중
    • 혜화의학회지
    • /
    • 제8권2호
    • /
    • pp.211-243
    • /
    • 2000
  • This study was performed to investigate the cause, symptom, treatment, medicine of Wei symptom through the literature of oriental and western medicine. The results obtained were as follows: 1. Wei symptom is the symptom that reveals muscle relaxation without contraction and muscle relaxation occures in the lower limb or upper limb, in severe case, leads to death. 2. Since the pathology and etiology of Wei symptom was first described as "pe-yeol-yeop-cho"(肺熱葉焦) in Hung Ti Nei Ching(黃帝內經), for generations most doctors had have accepted it. but after Dan Ge(丹溪), it had been classified into seven causes, damp-heat(濕熱), phlegm-damp(濕痰), deficiency of qi(氣虛), deficiency of blood(血虛), deficiency of yin(陰處), stagnant blood(死血), stagnant food(食積). Chang Gyeng Ag(張景岳) added the cause of deficiency of source qi(元氣). 3. The concept of "To treat Yangming, most of all"(獨治陽明) was emphasized in the treatment of Wei symptom and contains nourishment of middle warmer energy(補益中氣), clearance of yangming-damp-heat(淸化陽明濕熱). 4. Since Nei-ching era(內經時代), Wei and Bi symptom(痺症) is differenciated according to the existence of pain. After Ming era(明代) appeared theory of co-existence of Wei symptom and pain or numbness but they were accepted as a sign of Wei symptom caused by the pathological factor phelgm(痰), damp(濕), stagnancy(瘀). 5. In the western medical point of view, Wei symptom is like paraplegia, or tetraplegia. and according to the causative disease, it is accompanied by dysesthesia, paresthsia, pain. thus it is more recommended to use hwal-hyel-hwa-ae(活血化瘀) method considering damp-heat(濕熱), qi deficiency of spleen and stornach(脾胃氣虛) as pathological basis than to simply differenciate Wei and Bi symptom according to the existence of pain. 6. The cause of Gullian-Barre syndrome(GBS) is consist of two factors, internal and external. Internal factors include asthenia of spleen and stomach, and of liver and kidney. External factors include summur-damp(暑濕), damp-heat(濕熱), cold-damp(寒濕) and on the basis of "classification and treatment according to the symptom of Zang-Fu"(臟腑辨證論治), the cause of GBS is classified into injury of body fluid by lung heat(肺熱傷津), infiltration of damp-heat(濕熱浸淫), asthenia of spleen and kidney(脾腎兩虛), asthenia of spleen and stomach(脾胃虛弱), asthenia of liver and kidney (肝腎兩虛). 7. The cause of GBS is divided by according to the disease developing stage: Early stage include dryness-heat(燥熱), damp(濕邪), phlegm(痰濁), stagnant blood(瘀血), and major treatment is reducing of excess(瀉實). Late stage include deficiency of essence(精虛), deficiency with excess(虛中挾實), and essencial deficiency of liver and kidney(肝腎精不足) is major point of treatment. 8. Following is the herbal medicine of GBS according to the stage. In case of summur-damp(暑濕), chung-seu-iki-tang(淸暑益氣湯) is used which helps cooling and drainage of summer-damp(淸利暑濕), reinforcement of qi and passage of collateral channels(補氣通絡). In case of damp-heat, used kun-bo-hwan(健步丸), In case of cool-damp(寒濕), used 'Mahwang-buja-sesin-tang with sam-chul-tang'(麻黃附子細辛湯合蓼朮湯). In case of asthenia of spleen and kidney, used 'Sam-lyeng-baik-chul san'(蔘笭白朮散), In case of asthenia of liver and kidney, used 'Hojam-hwan'(虎潛丸). 9. Following is the herbal medicine of GBS according to the "classification and treatment according to the symptom of Zang-Fu"(臟腑辨證論治). In the case of injury of body fluid by lung heat(肺熱傷津), 'Chung-jo-gu-pae-tang'(淸燥救肺湯) is used. In case of 'infiltration of damp-heat'(濕熱浸淫), us-ed 'Yi-myo-hwan'(二妙丸), In case of 'infiltration of cool-damp'(寒濕浸淫), us-ed 'Yui-lyung-tang', In case of asthenia of spleen, used 'Sam-lyung-bak-chul-san'. In case of yin-deficiency of liver and kidney(肝腎陰虛), used 'Ji-bak-ji-hwang-hwan'(知柏地黃丸), or 'Ho-jam-hwan'(虎潛丸). 10. Cervical spondylosis with myelopathy is occuered by compression or ischemia of spinal cord. 11. The cause of cervical spondylosis with myelopathy consist of 'flow disturbance of the channel points of tai-yang'(太陽經兪不利), 'stagnancy of cool-damp'(寒濕凝聚), 'congestion of phlegm-damp stagnant substances'(痰濕膠阻), 'impairment of liver and kidney'(肝腎虛損). 12. In treatment of cervical spondylosis with myelopathy, are used 'Ge-ji-ga-gal-geun-tang-gagam'(桂枝加葛根湯加減), 'So-hwal-lack-dan-hap-do-hong-eum-gagam(小活絡丹合桃紅飮加減), 'Sin-tong-chuck-ue-tang-gagam(身痛逐瘀湯加減), 'Do-dam-tang-hap-sa-mul-tang-gagam'(導痰湯合四物湯加減), 'Ik-sin-yang-hyel-guen-bo-tang'(益腎養血健步湯加減), 'Nok-gakyo-hwan-gagam'(鹿角膠丸加減). 13. The cause of muscle dystropy is related with 'the impairement of vital qi'(元氣損傷), and 'impairement of five Zang organ'(五臟敗傷). Symptoms and signs are classified into asthenia of spleen and stomach, deficiency with excess, 'deficiency of liver and kidney'(肝腎不足) infiltration of damp-heat, 'deficiency of qi and blood'(氣血兩虛), 'yang deficiency of spleen and kidney'(脾腎陽虛). 14. 'Bo-jung-ik-gi-tang'(補中益氣湯), 'Gum-gang-hwan'(金剛丸), 'Yi-gong-san-hap-sam-myo-hwan'(異功散合三妙丸), 'Ja-hyel-yang-gun-tang'(滋血養筋湯), 'Ho-jam-hwan'(虎潛丸) are used for muscle dystropy. 15. The causes of myasthenia gravis are classified into 'insufficiency of middle warmer energy'(中氣不足), 'deficiency of qi and yin of spleen and kidney'(脾腎兩處), 'asthenia of qi of spleen'(脾氣虛弱), 'deficiency of qi and blood'(氣血兩虛), 'yang deficiency of spleen and kidney'(脾腎陽虛). 16. 'Bo-jung-ik-gi-tang-gagam'(補中益氣湯加減), 'Sa-gun-ja-tang-hap-gi-guk-yang-hyel-tang'(四君子湯合杞菊地黃湯), 'Sa-gun-ja-tang-hap-u-gyi-eum-gagam'(四君子湯合右歸飮加減), 'Pal-jin-tang'(八珍湯), 'U-gyi-eum'(右歸飮) are used for myasthenia gravis.

  • PDF

소방이 형성된 결핵성 흉막염 환자에서 경피적 도관을 이용한 유로카나제 치료의 효과 ; 전향적 무작위연구 (The Effects of Urokinase Instillation Therapy via Percutaneous Transthoracic Catheter Drainage in Loculated Tuberculous Pleural Effusion: A Randomized Prospective Study)

  • 이용환;곽승민;권미영;배인영;박찬섭;문태훈;조재화;류정선;이홍렬;노형근;조철호
    • Tuberculosis and Respiratory Diseases
    • /
    • 제47권5호
    • /
    • pp.601-608
    • /
    • 1999
  • 연구배경: 결핵성 흉막염은 항결핵요법만으로 치료가 잘되므로 일반적으로 진단적 흉수천자이외에 흉막염의 적극적 배액은 불필요하다고 알려져 있다. 그러나 항결핵요법 후에도 흉막박피술등의 처치가 필요할 정도로 흉막비후가 오는 경우를 비교적 흔히 접하게 된다. 이에 저자들은 소방이 형성된 결핵성 흉막염 환자에게 경피적 도관을 이용한 유로키나제 치료로 적극적 배액을 시도한 경우와 진단적 흉수천자와 항결핵요법으로 치료한 경우 흉막비후의 차이가 있는지에 대한 비교연구를 함으로서, 소방이 형성된 결핵성 흉막염 환자에서 유로키나제에 의한 흉막비후에 대한 치료효과를 결정하고 자하였다. 방 법: 소방이 형성된 결핵성 흉막염으로 확진된 37명의 환자를 대상으로 전향적 무작위연구로 16명의 유로키나제군(경피적 도관을 삽입 후 유로키나제 투여+항결핵제 투여)과 21명의 비유로키나제군(항결핵제 투여)으로 나누어, 두군 환자들의 치료전 후의 흉부사진으로 흉막비후(RPT) 을 관찰하였으며, 또한 두 군의 진단당시 임상상 및 흉막액의 백혈구수, pH, 혈당, 단백질, LDH, ADA를 비교하였다. 결 과: 1) 유로키나제군과 비유로카나제군의 흉막비후는 각각 $5.08{\pm}6.77$ mm와 $20.32{\pm}26.37$ mm로, 유로키나제군에서 흉막비후가 유의하게 적었다(P<0.05). 2) 두 군의 흉막비후에(RPT$\geq$10 mm) 영향을 미치는 임상적 지표 중 흉통, 발열, 호흡곤란 등 치료 전 증상 발현기간이 흉막비후가(RPT$\geq$10 mm) 있는 경우(평균 $5.23{\pm}3.89$ 주)가 흉막비후가 없는 경우(평균 $2.63{\pm}1.99$ 주)보다 의의 있게 길었다(p<0.05). 3) 흉막비후(RPT는 10 mm)의 예측인자로 흉수액 천자검사에서 백혈구수, pH, 혈당, 단백질, LDH, ADA등은 차이가 없었다. 결 론: 소방이 형성된 결핵성 흉막염 환자에서 항결핵제 치료 와 함께 유로키나제를 이용한 흉막액의 적극적 배액시 흉막비후의 후유증을 줄일 수 있는 것으로 생각된다.

  • PDF

특발성폐섬유화증에서 스테로이드와 면역억제제의 단기 치료효과 및 치료반응 예측인자 (Short-Term Efficacy of Steroid and Immunosuppressive Drugs in Patients with Idiopathic Pulmonary Fibrosis and Pre-treatment Factors Associated with Favorable Response)

  • 강경우;박상준;고영민;이상표;서지영;정만표;한정호;김호중;권오정;이경수;이종헌
    • Tuberculosis and Respiratory Diseases
    • /
    • 제46권5호
    • /
    • pp.685-696
    • /
    • 1999
  • 연구배경 : 특발성폐섬유화증은 만성적으로 간질 및 폐포에 염증반응과 섬유화가 진행되어 평균 생존기간이 5년 정도에 불과한 예후가 나쁜 질환이고 스테로이드나 면역억제제와 같이 부작용이 많은 약물치료로 효과를 보이는 환자는 일부에 불과하여 적극적 치료를 하기 힘든 실정이다. 이에 저자들은 특발성폐섬유화증에서 스테로이드 및 면역억제제 치료의 단기간 치료효과를 평가하면서 치료효과에 영향을 미치는 인자를 밝히고자 하였다. 방 법 : 1997년 1월부터 1998년 6월까지 삼성서울병원에서 수술적 폐생검을 통해 특발성 폐섬유화증으로 확진된 환자중 질환의 활동성이 있다고 판단되어 스테로이드나 면역억제제를 투여한 후 6개월이 경과한 18명 환자의 기록과 방사선 소견을 조사하였다. 치료전 기저검사로는 병력청취를 통한 임상적 특정과 폐기능검사, 기관지폐포세척술, 흉부HRCT를 시행하였고 치료 6개월째에 호흡곤란 정도의 변화, 폐기능검사의 변화와 흉부HRCT에서 병변 범위의 변화를 종합하여 치료효과를 판정하였다. 호전군은 1) 호흡곤란의 정도가 1단계이상 호전 2) FVC 또는 TLC가 10% 이상, 또는 DLco가 20% 이상 증가 3) 흉부HRCT소견상의 호전과 같은 3가지 항목중 2가지 이상 만족한 군으로 판정하였으며 나머지는 비호전군으로 정의하였다. 결 과 : 대상환자의 특성 대상환자 18명의 연령분포는 46세에서 69세로 연령의 중앙값은 54세였고, 남자가 6명, 여자가 12명이었다. 평균 흡연력은 8.6년이었고 치료전 호흡기증상의 기간이 평균 10개월이었다. 치료약제의 사용 전체 18명의 환자중 12명에서 prednisolone으로 치료를 시작하여 이중 2명은 치료중에도 임상적으로 악화를 보여 cyclophosphamide로 치료를 전환하였으나 질환의 악화가 진행하였으며 나머지 10명은 prednisolone만으로 끝까지 치료하여 7명이 호전군으로 판정되었다. Cyclophosphamide로 치료를 시작하였던 6명은 모두 약제변경없이 끝까지 투여하여 2명이 호전군으로, 4명은 비호전군으로 판정되었다. 치료효과 및 약제부작용 18명의 환자중 호전군이 9명이었고 비호전군이 9명이었다. 폐기능검사상 호전군에서 유일하게 FVC가 평균 15.7%가 증가하였고(p<0.05) 흉부HRCT 소견중 간유리음영의 면적이 유의한 감소를 보였으며($8.5{\pm}3.6%$ 감소, p<0.05) 비호전군에서는 불규칙 망상음영(2.7% 증가, p<0.05) 과 봉와양음영(7.0% 증가, p<0.05)의 범위가 증가하였다. 치료약제의 부작용으로는 스테로이드 유발성 정신병이 1명에서 발생하였는데 중도에 치료를 포기하여 최종 대상환자 18명에는 포함되지 않았고, 나머지 스테로이드 복용환자중 결핵성 늑막염 1명, 대상포진 2명, 백내장 1명, 당뇨병이 1명에서 발생하였고 cyclophosphamide 복용 환자군에서는 가벼운 위장장애 외에는 특별한 부작용이 없었다. 치료효과에 대한 예측인자 조직학적 분류상 NSIP(p<0.001), 여성(p<0.01), 호흡곤란의 정도가 3단계이상(p<0.05) 및 비흡연자(p<0.001), BAL 검사상 임파구 증가 소견(p<0.05)이 있었던 경우와 흉부HRCT상 불규칙 망상음영이나 봉와양음영의 면적이 적었던 경우(p<0.05)에 치료에 대한 반응이 좋았다. 결 론 : 특발성폐섬유화증 환자에서 내과적 약물치료는 적지 않은 부작용이 있었으나, 병리진단이 NSIP로 확인되거나 기관지폐포세척술 검사상 임파구 증가 소견이 있는 환자는 적극적인 스테로이드 및 면역억제제 치료를 통해 호전될 수 있을 것으로 생각된다. 향후 좀 더 많은 환자수에서 다변량분석을 통해 이러한 예측인자들의 독립적인 변수로서의 검정이 필요하리라 사료된다.

  • PDF

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

캐나다 Athabasca 오일샌드의 투수도 모델링을 위한 다양한 탄성파 속성들을 이용한 상 구분 향상 (Improvement in facies discrimination using multiple seismic attributes for permeability modelling of the Athabasca Oil Sands, Canada)

  • Kashihara, Koji;Tsuji, Takashi
    • 지구물리와물리탐사
    • /
    • 제13권1호
    • /
    • pp.80-87
    • /
    • 2010
  • 본 연구는 Athabasca 오일샌드광구의 역청 생산방법인, SAGD 수행에 영향을 주는 불균질한 유효투수도의 분포도를 만드는 저류층 모델링 작업 공정을 개발하기 위한 것이다. 암석학적 상 분포는 연구 지역 역청 저류층 내의 불균질성의 주요 원인이다. 대상 매질은 사암과 이암으로 구성된 하천에서 바다로 이어지는 채널로서 이암이 유체의 흐름을 방해해 유효 투수도를 감소시키고 있다. 본 연구에서는 암석학적 상등을 이암의 모양에 따라 마른 특성의 유효투수도를 갖는 세 종류로 분류하였다. 본 연구의 저류층 모델링 작업과정은 상 모델과 투수도 모델링, 두 가지 주요 모듈로 구성되어 있다. 상 모델링은 확률적인 접근을 이용하여 유효투수도 결정에 중요한, 세가지 상등 중에 어떤 종류에 속하는지를 알려준다. 투수도 모델링은 먼저 이암의 체적율을 구하고 그것을 유효투수도로 변환시킨다. 암석상들의 소형 모델에 대한 일련의 시뮬레이션 적용을 통해 이암 체적율을 유효투수도로 변환시키는 변환함수를 얻는다. 탄성파 자료는 지구통계학적 방법으로 상 모델링에 입력되는 상등의 우선 확률을 제공함으로써 상 모델링에 기여한다. 특히, 본 연구에서는 상들의 우선 확률을 개선하기 위해 상등의 예측 시 다양한 탄성파 속성들을 복합적으로 사용하는 신경망 방법을 이용하였다. 상 구분에 있어서의 얼마만큼 개선되었는지를 보여주기 위해 상 모델링 시 개선된 우선 확률을 사용한 결과를 단일 탄성파 속성을 이용하는 기존 방법의 결과와 비교하였다. 다중 탄성파 속성들의 복합적인 사용에서 밀도와 P파 속도를 조합해서 이용하는 것이 상구분을 향상시키는데 필수적이다. 또한 본 연구에서는 검층으로부터 얻은 공극률과 P파 속도, 사진찍은 것 같이 예측된 이암의 부피를 이용하여 sand matrix의 공극률이 정확하게 평가원 연구지역에서, 다른 상등 사이에서 P파 속도가 달라지게 하는 sand matrix의 공극률에 대해서도 논의하였다.

영아 비후성 유문협착증 - 대한소아외과학회 정회원을 대상으로 한 전국조사 - (Infantile Hypertrophic Pyloric Stenosis - A Survey by the Korean Association of Pediatric Surgeons -)

  • 김인구;김상윤;김신곤;김우기;김재억;김재천;김현학;박귀원;박영식;박우현;송영택;양정우;오수명;유수영;이두선;이명덕;이석구;이성철;장수일;정상영
    • Advances in pediatric surgery
    • /
    • 제4권2호
    • /
    • pp.149-155
    • /
    • 1998
  • Thirty three members of the Korean Association of Pediatric Surgeons were surveyed to determine the clinical manifestations and current management of infantile hypertrophic pyloric stenosis (IHPS). The members completed a registration form and a questionnaire that indicated their treatment preferences for patients treated during 1996. The response rate was 84.8 %, and 23 institutions participated. Three hundred and sixty-three cases of IHPS were analysed. The male to female ratio was 5.15: 1. The presenting symptoms were nonbilious vomiting in 363 cases(100 %), palpable mass in the upper abdomen in 200 cases (55.1 %) and visible peristaltic waves in 67 cases(18.5 %). Fluid therapy was done in 161 cases(44.4 %) for preoperative preparation. Twenty patients(5.5 %) were premature. There were 27 low birth weight babies(7.7 %). The onset of symptoms ranged from 1 to 14 weeks of age with a peak occurrence at 2 to 4 weeks of age. Two hundred and thirty-six cases(66.6 %) presented within 4 weeks of age. There was one set of male twins and a family history of twins. The modes of feedings were: breast feeding; 69 cases(24.5 %), formula feeding; 176 cases(62.4 %) and mixed feeding; 37 cases(13.1 %). The preferred diagnostic modalities were ultrasonography (US) 229 cases(63.1 %), UGI series 27 cases(7.4%) and US and UGI series combined 86 cases(23.7 %). Only 21 cases(5.8 %) were operated on without imaging study, ie. with positive physical finding. Perforation of the mucosa during pyloromytomy occurred in 5 cases. All were treated successfully with primary closure. Persistent vomiting over 2 weeks after operation were reported in 5 cases. Three wound infections, one aspiration pneumonia and one postoperative bleeding were reported. There was no mortality in 363 cases.

  • PDF