• 제목/요약/키워드: turn over

검색결과 706건 처리시간 0.035초

A collaborative simulation in shipbuilding and the offshore installation based on the integration of the dynamic analysis, virtual reality, and control devices

  • Li, Xing;Roh, Myung-Il;Ham, Seung-Ho
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권2호
    • /
    • pp.699-722
    • /
    • 2019
  • It is difficult to observe the potential risks of lifting or turn-over operations in the early stages before a real operation. Therefore, many dynamic simulations have been designed to predict the risks and to reduce the possibility of accidents. These simulations, however, have usually been performed for predetermined and fixed scenarios, so they do not reflect the real-time control of an operator that is one of the most important influential factors in an operation; additionally, lifting or turn-over operations should be a collaboration involving more than two operators. Therefore, this study presents an integrated method for a collaborative simulation that allows multiple workers to operate together in the virtual world. The proposed method is composed of four components. The first component is a dynamic analysis that is based on multibody-system dynamics. The second component is VR (virtual reality) for the generation of realistic views for the operators. The third component comprises the control devices and the scenario generator to handle the crane in the virtual environment. Lastly, the fourth component is the HLA (high-level architecture)-based integrated simulation interface for the convenient and efficient exchange of the data through the middleware. To show the applicability of the proposed method, it has been applied to a block turn-over simulation for which one floating crane and two crawler cranes were used, and an offshore module installation for which a DCR (dual-crane rig) was used. In conclusion, the execution of the proposed method of this study is successful regarding the above two applications for which multiple workers were involved.

Design on Multi-Surveillance System for turn-out stations of the railway

  • Oh, Se-Ho;Park, Jung-Gyun;Park, Hyen-Young;Lee, Yong-Jae;Kim, Yang-mo
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -1
    • /
    • pp.579-582
    • /
    • 2002
  • For train service, safety and reliability is an inevitable performance. Specially, turn-out system of the railway for safety because of actual part. Hence the management is strictly executed over turn-out systems of the railway. Also number of turn-out system need to monitoring systems. In this paper, the data multi-acquisition system for monitoring it is necessary to reduce the cost from the expensive characteristics of multi-monitoring system according to the importance of each data because this system is based on communication of one to several units. We designed the data multi-acquisition system using numbers of micro-controller and the experiment was executed to the actual turn-out system.

  • PDF

무절연 고온 초전도 레이스트랙형 코일의 직선구간 압력변화에 따른 열적 안정성 연구 (A Study on Thermal Stability of the Non-insulated HTS Racetrack-type Coil Under Various External Pressures Applied to Straight Sections)

  • 권오준;김광록;최윤혁;양동규;김영균;이태성;고태국;이해근
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제14권3호
    • /
    • pp.33-37
    • /
    • 2012
  • An HTS racetrack-type coil without turn-to-turn insulation was characterized by critical current, sudden discharge, and over-current tests with respect to external pressures applied to the straight sections of the coil. The thermal stability of the non-insulated HTS racetrack-type coil was remarkably enhanced with increasing external pressure applied to the straight sections of racetrack-type coil. Furthermore, over-current test results confirmed that the non-insulated HTS racetrack-type coil with increased turn-to-turn thermal contact has the potential to be manufactured into field coils of HTS wind turbine generators with highly enhanced thermal and electrical stabilities.

초전도 한류기의 턴간 절연특성 (Dielectric Characteristics of Turn-ro-Turn Insulation for SFCL)

  • 백승명;정종만;이창화;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.65-68
    • /
    • 2003
  • Interconnected power system operation has given rise to the problem of increased fault levels and leads to over stressing of all the components. Use have been made of recently developed high Tc superconductor in devising a superconducting fault current limiter (SFCL) that promises optimum performance in terms of capital cost, size, auto sensing, operational losses, response time and reliability. Recently, research about the application of the SFCL is actively progressing in Korea. To be applied for SFCL practically, the electrical insulation design of SFCL must be developed. Therefore, this paper presents the result of an investigation of the dielectric characteristics of turn-to-turn insulation for SFCL in liquid nitrogen. The dielectric characteristics of turn-to-turn insulation models of SFCL were investigated. We obtained following results. The breakdown voltages increased as the spacer thickness and length increased. And the breakdown voltages of turn-to-turn model without spacer were higher than the breakdown voltages of turn-to-turn model with spacer under impulse as well as AC voltages. The information gathered in this test series should be helpful in the design of liquid nitrogen filled SFCL.

  • PDF

실리콘 다층절연막의 전기전도 특성 (The electrical conduction characteristics of the multi-dielectric silicon layer)

  • 정윤해;한원열;박영걸
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제7권2호
    • /
    • pp.145-151
    • /
    • 1994
  • The multi-dielectric layer SiOz/Si3N4/SiO2(ONO) is used to scale down the memory device. In this paper, the change of composition in ONO layer due to the process condition and the conduction mechanism are observed. The composition of the oxide film grown through the oxidation of nitride film is analyzed using auger electron spectroscopy(AES). AES results show that oxygen concentration increases at the interface between oxide and nitride layers as the thickness -of the top oxide layer increases. Results of I-V measurement show that the insulating properties improve as the thickness of the top oxide layer increases. But when the thickness of the nitride layer decreases below 63.angs, insulating peoperties of film 28.angs. of top oxide and film 35.angs. turn over showing that insulating property of film 28.angs. of top oxide is better than that of film 35.angs. of top oxide. This phenomenon of turn over is thought as the result of generation of surface state due to oxygen flow into nitride during oxidation process. As the thickness of the top oxide and nitride increases, the electrical breakdown field increases, but when the thickness of top oxide reaches 35.angs, the same phenomenon of turn over occurs. Optimum film thickness for scaled multi-layer dielectric of memory device SONOS is estimated to be 63.angs. of nitride layer and 28.angs. of top oxide layer. In this case, maximum electrical breakdown field and leakage current are 18.5[MV/cm] and $8{\times}{10^-12}$[A], respectively.

  • PDF

신호교차로에서 곡선반경에 따른 좌회전의 직진환산계수 산정 (Estimation of the Through Car Equivalent for Left-Turn Movement According to the Left-Turn Curve Radius in the Signalized Intersection)

  • 오영태;김기형
    • 대한교통학회지
    • /
    • 제19권2호
    • /
    • pp.21-28
    • /
    • 2001
  • 본 연구는 다양한 좌회전 곡선반경을 갖고 있는 교차로에서의 좌회전 포화교통류율의 분석을 통하여 좌회전의 직진환산계수를 산정하는 것이다. 한국 도로 용량편람에서는 곡선반경이 약 20m 이상인 곳에서는 좌회전 전용차로에 대하여 직진과 같은 포화교통류율을 보이는 것으로 조사되어 좌회전 보정계수는 없는 것으로 제안하고 있다. 하지만 KHCM은 간선도로 위주로 조사 분석되어 곡선반경이 20m 이하인 교차로가 제외되어 있다. 이에 본 연구에서는 좌회전 전용차로 1개를 갖고 곡선반경이 20m 이하인 교차로 포함하여 다양한 곡선반경 가진 교차로를 대상으로 연구를 수행하였다. 본 연구에서는 포화교통류율을 산출하는데 있어서 분산분석의 후속단계인 다중비교(Multiple comparison)방법중 던컨검정(Duncan's Test)을 이용하였다. 본 연구에서 산정된 좌회전의 직진환산계수는 도로용량편람에서 교차로 분석시 교차로 곡선반경을 반영한 정확한 포화교통류율을 산정할 수 있다. 본 연구의 결과는 좌회전 곡선반경 20m 미만 교차로에서의 좌회전 S는 직진포화교통류율 보다 낮게 결과가 나타났다. 이를 직진환산계수화 시키면 좌회전 곡선반경에 따라서 1.05에서 1.14사이다.

  • PDF

Bay길이에 따른 좌회전 용량산정에 관한 연구 (A study on Left turn Capacity by Bay Length)

  • 김정례;김기혁
    • 대한교통학회지
    • /
    • 제20권3호
    • /
    • pp.31-39
    • /
    • 2002
  • 본 연구는 신호교차로의 좌회전 용량을 파악하기 위하여 bay차로를 포함한 좌회전 이동류의 용량산정 모형을 개발하는데 목적이 있다. 본 연구에서는 신호교차로의 혼잡을 완화시키기 위해 설치 운용되고 있는 좌회전 bay 차로의 용량을 파악하여 보다 정확한 용량산정치 적용을 통한 교차로 운영의 분석자료를 제시하고자 한다. 연구방법은 좌회전 bay길이를 20∼120m까지 변화시키며, bay차로와 전용차로에 대한 차두시간을 분석하였다. Bay차로의 용량산정을 위해 차두시간과 차량유출행태 특성에 따라 1구간(출발손실구간:SLP), 2구간(포화차두구간:SFP), 3구간(차로선택구간:LSP)으로 구분하여 분석하였다. 수집된 차두시간 자료로 차량 대기위치순서별로 분석하였다 자료의 통계적 검증을 통하여 구간대별 평균차두시간을 설정한 후, bay길이별 용량산정 모형을 도출하였으며, 이를 이용하여 bay길이별 좌회전 용량을 산출하였다.

스너버 회로를 위한 TVS 소자의 활용 연구 (A Study on the application of TVS for snubber)

  • 이완윤;정교범
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.227-230
    • /
    • 2002
  • The switching device in an inductive circuit is stressed by the over-voltage at the turn-off time. Thus if the peak value of the over-voltage is not properly limited, the switching device may be broken. Therefore, the snubber circuit should be added to protect the switching device from the over-voltage. The circuit designer must be familiar with the design of the snubber This paper tests the possibility that TVS instead of the conventional snubber can be applied to the protection circuit of the switching device without using the complicated design equations, and shows that the rating of TVS can be easily selected by considering only several parameters of TVS. The experimental results show the reduced switching voltage of the switching device at the turn-off time.

  • PDF

지방근막 역전 피판을 이용한 발과 발목의 재건 (Adipofacial Turn-Over Flap for Reconstruction of the Foot and Ankle)

  • 이원재;양은정;탁관철;정윤구
    • Archives of Plastic Surgery
    • /
    • 제34권4호
    • /
    • pp.441-447
    • /
    • 2007
  • Purpose: Various kinds of local flap or free flap have been used for coverage for soft tissue defects with bone exposure over the ankle and dorsum of foot. Adipofascial flaps, nourished by vascular plexuses of the subcutaneous tissue and deep fascia originating from the local perforators of the major vessels, appear particularly to be indicated for the reconstruction of these areas. Our experience with this flap on the dorsum of foot and ankle has also been quite encouraging. Methods: The design of the flap is determined by the size and the location of the defect. The base of the flap is chosen depending on the availability of the soft tissue around the defect. The ratio of the area of the flap to the area of the base wound be more reliable to predict the survival of the turnover flap by the conventional length-to-width ratio. Nineteen patients with defect over the dorsum of the foot and ankle were resurfaced with adipofascial turn-over flaps and skin graft. Results: The average age of the patients was 38.2 years(3 - 81 years). The flap size was from $2{\times}3cm$ to $8{\times}5cm$. The average follow-up time was 6 months. All flaps survived completely except one case who suffered distal necrosis of the flap. The additional skin graft was required for partial skin loss in the five cases. Other functional impairment was not noted. Conclusion: Dissection of the local adipofascial turnover flap is quite easy, quick, requires less time and sacrifice of surrounding muscle itself, and maintains major arteries. In most cases, donor-site morbidity is minimal with an acceptable scar, and both functional and esthetical results were satisfactory. Therefore, Adipofascial flap could be an option for the difficult wounds around the foot and ankle.

Spike와 Turn 변수를 이용한 표면근전도 신호의 진폭 추정 (Surface EMG Amplitude Estimation by using Spike and Turn Variables)

  • 이진
    • 전기학회논문지
    • /
    • 제67권1호
    • /
    • pp.124-130
    • /
    • 2018
  • The EMG amplitude estimator, which has been investigated as an indicator of muscle force, is of high relevance not only in biomechanical studies but also more and more in clinical applications. This paper presents a new approach to estimate surface EMG amplitude by using the mean spike and mean turn amplitude(MSA and MTA) variables. Surface EMG signals, a total of 198 signals, were recorded from biceps brachii muscle over the range of 20-80%MVC isometric contraction and performance of the MSA and MTA variables applied to amplitude estimation of the EMG signals were investigated. To examine the performance, a SNR(signal-to-noise ratio) was computed from each amplitude estimate. The results of the study indicate that MSA and MTA amplitude estimations with first order whitening filter and 300[ms]-350[ms] moving average window length are optimal and show better performance(mean SNR improvement of 6%-15%) than the most frequently used variables(ARV and RMS).