• Title/Summary/Keyword: turbidity analysis

Search Result 317, Processing Time 0.026 seconds

Analysis of water withdrawal and quality of intake pipe with functional screen (기능성 스크린이 부착된 집수관의 취수량 및 수질 분석)

  • Yang, Jeong-Seok;Kim, Il-Hwan;Jeong, Jae-Hoon
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.8
    • /
    • pp.579-586
    • /
    • 2017
  • In order to analyze the quantitative water withdrawal amount of intake pipe with functional screen and to evaluate the improvement effect of the suspended solid and turbidity through the filter media, four-step research methods were suggested. In the first step, laboratory scale experiments were constructed to determine the constitution method of the sample device filter media. In the second step, sample device was constructed and the flow rate was observed through intake pipe with functional screen. In the third step, flow rate was observed at different turbidity conditions for each filter material, and the hydraulic conductivity was estimated using MODFLOW. Finally, numerical model was constructed with the MODFLOW for the sample device and the estimated hydraulic conductivities were applied to the third step and the amount of water withdrawal was analyzed. As a result of applying hydraulic conductivity at 0 NTU, 39.96% more withdrawal was calculated than the observed flow rate. On the other hand, when hydraulic conductivity was applied at 100~120 NTU, the difference in flow rates was 9.41%.

Development of SV30 Detection Algorithm and Turbidity Assumption Model using Image Analysis Method (이미지 분석기법을 이용한 SV30 자동감지방법 및 탁도 추정 모델 개발)

  • Choi, Soo-Jung;Kim, Ye-Jin;Yoom, Hoon-Sik;Cha, Jae-Hwan;Choi, Jae-Hoon;Kim, Chang-Won
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.168-174
    • /
    • 2008
  • Diagnosis on setteability based on human operator's experimental knowledge, which could be established by long term operation, is a limit factor to construction of automation control system in wastewater treatment plant. On-line SVI(Sludge Volume Index) analyzer was developed which can measure SV30 automatically by image capture and image analysis method. In this paper, information got by settling process was studied using On-line SVI analyzer for better operation & management of WWTPs. First, SV30 detection algorithm was developed using image capture and image analysis for settling test and it showed that automatic detection is feasible even if deflocculation and bulking was occurred. Second, turbidity assessment model was developed using image analysis.

Study of the Floc Size Distribution for the Efficiency Assessment of Flocculation Process in Water Works (플럭크기를 이용한 응집공정 진단에 관한 연구)

  • Jung, Jin-Hong;Choi, Gye-Woon;Park, Jae-Roh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.12
    • /
    • pp.7438-7442
    • /
    • 2014
  • An assessment of flocculation was performed by measuring the distribution of the floc size during sedimentation in water works. The size and number of flocs have a greater effect on an evaluation of the efficiency of flocculation rather than the turbidity. The data was collected in situ using particle image velocimetry and image analysis. The measurements were carried out at a water depth of 1m. The removal efficiency of the total organic compounds, UV absorbance and turbidity depended on the size and floc size distribution in flocculation as the G value. The G value of 50 sec-1, 30 sec-1 and 10 sec-1 showed the highest degree of efficiency in the case of an inlet water turbidity of 5 NTU, and the highest degree of efficiency was observed at a G value of 65 sec-1, 40 sec-1 and 10 sec-1 when the inlet water turbidity was 263 NTU. The number of flocs with a distribution of above $1,200{\mu}m$ was 14. The dynamics between two important growth mechanisms were investigated as the energy input changed. This is a certain method that makes use of the size and number of flocs as an efficiency assessment.

Spatial Distribution of Epilithic Diatom Communities in the Estuary of Korean Peninsula (한반도 하구역 부착돌말류의 공간적 분포)

  • Kim, Ha-Kyung;Cho, In-Hwan;Kim, Young-Hyo;Lee, Min-Hyuk;Kim, Yong-Jae;Won, Du-Hee;Hwang, Su-Ok;Byun, Jung-Hwan;Hwang, Soon-Jin;Kim, Baik-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.51 no.1
    • /
    • pp.1-15
    • /
    • 2018
  • With land-use (cover) and water quality, the distributional characteristics of epilithic diatom communities were studied with 193 samples from estuaries of Korean peninsula between 2015 and 2016. Of total 394 taxa classified, Nitzschia perminuta (19.6%) and N. inconspicua (14.0%) were the 1st and 2nd dominant species. Using a cluster analysis, the epilithic diatom communities of Korean estuaries were divided into four groups (G1-G4). Ecological characteristics of each group were followed: G1 was located in estuaries of the East Sea, and characterized by high forest land-use and high DO and low nutrients; G2 was the eastern part of the South Sea, and characterized by low turbidity and nutrients; G3 was the western part of the South Sea, and characterized by high agriculture, low electric conductivity and low salinity; G4 was the Yellow Sea, and characterized by high nutrients. The environmental factors having significant correlation with diatom distributions were as follows: TN to G1, turbidity to G2, agriculture to G3, and TP to G4. Moreover, the important factors affecting the occurrence of indicator species were forest land-use for Fragilaria construens var. venter in G1, turbidity for Rhoicosphenia abbreviata in G2, urban land- use and total phosphorus (TP) for Bacillaria paradoxa and Hantzschia amphioxys of G3, and TP and turbidity for N. ovalis and Stephanodiscus invistatus of G4. These results collectively indicate that the distribution of epilithic diatom communities in Korean peninsula was largely effected by water quality and land cover/use.

High Ferrihydrite Turbidity in Groundwater of Samdong-Myeon (Ulsan) by Carbonate-Water Inflow of Deep Origin (심부 탄산수의 유업에 의한 울산시 삼동면 지하수의 높은 페리하이드라이트 탁도)

  • Jeong, Gi-Young;Kim, Seok-Hwi;Kim, Kang-Joo;Jun, Seong-Chun;Ju, Jeong-Woung;Choi, Mi-Jung;Cheon, Jeong-Yong
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.91-99
    • /
    • 2011
  • The turbidity in several wells of Samdong-myeon, Ulsan, exceeded potable groundwater standard (1 NTU). Mineralogical analysis showed that the fine suspended particles are ferrihydrite spheres with a size of less than $0.5\;{\mu}m$ and helical iron-oxidizing bacterial filaments, and their aggregates. Ferrihydrite was almost amorphous only showing two electron diffraction rings, and contained Si and P. Helical bacterial filaments were almost replaced by ferrihydrite. The helical bacteria have played an important role in the ferrihydrite formation by becoming the loci for ferrihydrite precipitation as well as oxidizing ferrous iron. The physicochemical conditions of low pH, low redox potential, high Ca concentration, and high alkalinity are consistent with the hydrogeochemical characteristics of carbonate groundwater, implicating that the inflow of deep ferriferous carbonate groundwater and its oxidation have caused the ferrihydrite turbidity in several wells of the study area.

Optimizing Coagulation Conditions of Magnetic based Ballast Using Response Surface Methodology (반응표면분석법을 이용한 자성기반 가중응집제의 응집조건 최적화)

  • Lee, Jinsil;Park, Seongjun;Kim, Jong-Oh
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.12
    • /
    • pp.689-697
    • /
    • 2017
  • As a fundamental study to apply the new flocculation method using ballast in water treatment process, the optimal conditions for general and ballast coagulant dosage, and pH, which are known to have a significant influence, were derived by response surface methodology. Poly aluminum chloride (PAC) and magnetite ballast were used as a general coagulant and ballast, respectively. Coagulation experiments were performed by jar-tester using the kaolin based synthetic water. The effects of three independent variables (pH, PAC, and ballast) on response variables (turbidity removal rate and average settling velocity of flocs) and the optimum condition of independent variables to induce the optimum flocculation were obtained by 17 experimental conditions designed by Box-Behnken procedure. After performing experiments, the quadratic regression model was derived for each of response variables, and the response surface analysis was conducted to explore the correlation between independent variables and response variables. The $R^2$ values for the turbidity removal rate and the average settling velocity were 0.9909 and 0.8295, respectively. The optimal conditions of independent variables were 7.4 of pH, 38 mg/L of PAC and 1,000 mg/L of ballast. Under these conditions, the turbidity removal rate was more than 97% and the average settling velocity exceeded 35 m/h.

Effects of Temperature on Flocculation Kinetics Using Fe(III) Coagulant in Water Treatment (정수처리시 Fe(III) 응집제를 사용한 응집동력학에 대한 온도의 영향)

  • 강임석
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.181-194
    • /
    • 1995
  • Flocculation kinetics using ferric nitrate as a coagulant to coagulate kaolin clay in water was examined as a tool to investigate the effect of low temperature under tightly controlled treatment conditions. Both the particle size distribution data obtained from Automatic Image Analysis (AIA) system and the on-line measurement of the degree of turbidity fluctuation in a flowing suspension by Photometric Dispersion Analyzer (PDA) were used to measure flocculation kinetics. Results show that cold water temperature had a pronounced detrimental effect on flocculation kinetics. For improving flocculation kinetics at low water temperature, maintaining constant pOH to adjust water chemistry for temperature changes was found to be partially effective only in the more acidic pH range studied.

  • PDF

A Study on the concept of makwon in onbyeonghak(溫病學) and its practical application (온병학(溫病學)의 막원(膜原) 개념과 그 실제적 활용에 대한 고찰)

  • Kim, Sanghyun
    • Journal of Korean Medical classics
    • /
    • v.30 no.4
    • /
    • pp.83-93
    • /
    • 2017
  • Objective : Doctors' discussions on Makwon's warm-disease are studied in an effort to contemplate a way to use the outcome in practice. Method : Doctors' discussions on Makwon as found in researches and texts are categorized into physical and pathologica, and their symptoms and treatments are analyzed. Result & Conclusion : Many doctors of warm disease explained that, in terms of the physical aspect, Makwon is closely related to stomach. Some doctors also mentioned its relationship with triple engizers, defense and nutrient qi, and spleen. In terms of pathology, most of the doctors considered Makwon to be a hiding place of foul turbidity pathogen, and explained that a treatment has to be applied before the disease pattern worsens. Diverse syndroms of Makwonwere introduced. Their discussions mainly revolved around warm and epidemic or category of dampness-heat diseases. Alternating chills and fever was also mentioned often, and generalized pain, nausea, tongue of thick and slimy fur symptoms are shown. Ouguk's Dalwonneum is used as the basic treatment. The most effective prevention method of the incubation of pathogen are the symptoms that allows the analysis of the mechanism of disease. Therefore, a good utilization method of resolve turbidity with aroma or spices may contribute to the prevention of Makwon-disease in terms of cultural aspect.

Inquiry of Water Environment in Mihocheon (Stream) - Water Quality Monitoring focused on TOC - (미호천의 물 환경 탐구 - TOC를 중심으로 한 수질모니터링 -)

  • Lyu, Jai Hong;Lee, Du Gon
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.5
    • /
    • pp.731-739
    • /
    • 2007
  • In this study, water quality monitoring focused on TOC was performed at 5 points in Mihocheon (Stream) from January to December 2006. And 10 parameters (water temperature, pH, DO, EC, turbidity, SS, BOD, $PO_4-P$, TOC, TN) were monitored every month for one year. According to this study, TOC increased towards the lower stream (#4~#5). Correlation coefficients between TOC and DO, EC, turbidity, SS, BOD, $PO_4-P$, TN were -0.126, 0.351, 0.320, 0.286, 0.711, 0.525, 0.666. TOC was highly related to BOD. As a result of linear regression analysis, regression equation between BOD and TOC was BOD=0.58TOC+1.90 ($R^2=0.506$). In Mihocheon (Stream), BOD/TOC ratio decreased towards the lower stream. This results show decrease of ratio of biodegradable organic material to total organic pollutants towards the lower stream. This study is significant since it has revealed the potential value of TOC as organic material indicator for inquiry of water quality characteristics in the natural water system.

A study on the charateristic of Natural Spring Water Quality in Seoul (서울시 일원의 약수터 수질특성에 관한 연구)

  • 김익수;권승미;이지영;김주형;이재영
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.57-59
    • /
    • 2002
  • Because of the growing demand for protect and maintain one's health, population search for good water increase very rapid in recent. This study was performed to investigate the at 432 sites natural spring water quality in Seoul. Samples for analysis were collected form January to December in 2001. The quality of water was evaluated by analyzing fourty items of Korea drinking water criteria. The main results of this study were as follows 1. The rate of natural spring water was 26.6% and the Total colony, E.Coli and Yersinia of the total incongruence cause was 67.9% 2. The distribution of phisical-chemical item on the incongruence cause was Residues on evaporation 8.6%, Turbidity 4.3%, Nitrate nitrogen 2.5%, pH 2.5% and F-1,2% 3. The most population area of mean drinking population per one day was that man of Gangnam was 312.92 person. Next to Yangcheon Seocho Seodaemun and Dongjak was 229.6, 195.31, 190.50, 190,00 person. 4. The more person and the number of natural spring water, the more non passed drinking criteria natural spring water except for Gangnam and Gangbuk. 5. The corelationship of drinking population and results of the tests do not exist and the corelationship of results and Total colony, E.Coli, Color, Turbidity, KMNO4 consumption, Residues on evaporation, Fe, Mn, Zn and A1 are existed positive relationship.

  • PDF