• Title/Summary/Keyword: turbidity

Search Result 1,713, Processing Time 0.036 seconds

Analysis on the Correlation between Hydrological Data and Raw Water Turbidity of Han River Basin (한강수계의 수문자료와 원수탁도의 상관관계 분석)

  • Jeong, Anchul;Kang, Taeun;Kim, Seongwon;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • A correlation analysis between raw water turbidity at two wide-area water treatment plants and hydrological data was conducted for efficient water supply, design and management of water treatment plant. Both correlation analysis and principal component analysis were conducted using hydrological time series data such as inflow discharge, outflow discharge, and rainfall at dam basin of intake station of wide-area water treatment plants. And, forecasting of change in turbidity was conducted using regression equation for turbidity prediction. The raw water turbidity of two water treatment plants was strongly related to time series of discharge. The raw water turbidity of Chungju water treatment plant is strongly related to outflow discharge at Chungju dam (0.708). Whereas, the raw water turbidity of Wabu water treatment plant is strongly related to inflow discharge at Paldang dam (0.805). Similar trends between turbidity forecasting result using regression equation and calculation result using estimation equation on Korea water supply facilities standard were obtained. The result of this study can provide basic data for construction and management of water treatment plant.

The Predilution Effect of Al-based Liquid Coagulants for the Optimal Efficacy (최적 응집 효율을 위한 Al계 액상 응집제의 희석 효과)

  • Heo, Jae-Yong;Lee, Sang-Wha
    • Applied Chemistry for Engineering
    • /
    • v.17 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • The coagulation efficacy of Al-based coagulants (such as Alum, PACS, and PACC) was investigated to ascertain removal efficiencies of turbidity and phosphate with variation of solution pH, coagulant dosages, and pre-dilution ratios. The efficacy of Al-based coagulants was maximized in the pH range of 6~9. Under the initial condition of pH 8, $10mg/L\;{PO_4}^{3-}$, and 20 NTU, Al-based coagulants exhibited a similar efficacy in the removal of turbidity, whereas the removal efficiency of phosphate was clearly dependent on the basicity of coagulants: Alum (0%) > PACS (45~50%) > PACC (70%). At high initial turbidity of 100 NTU, polymeric coagulants, such as PACS and PACC, exhibited a higher removal efficiency of turbidity compared to Alum. In comparison to direct injection of coagulants at low initial turbidity (20 NTU), 500~2000 times pre-diluted Alum, exhibited reduced coagulation efficacy; however, removal efficiencies of turbidity and phosphate increased with the increase of retention time. Pres-diluted PACC exhibited the enhanced coagulation efficacy followed by silght decrease of the removal efficiencies with increase of the retention time. At high initial turbidity of 100 NTU, pre-diluted Alum and PACC exhibited higher removal efficiencies of turbidity and phosphate.

Formation and Evolution of Turbidity Maximum in thd Keum Estuary, West Coast of Korea (금강 하구에서의 최대혼탁수 형성 및 변화에 대한 연구)

  • 이창복;김태인
    • 한국해양학회지
    • /
    • v.22 no.2
    • /
    • pp.105-118
    • /
    • 1987
  • A series of anchor stations were occupied along the Keum EAstuary during six different periods of tidal and fluvial regimes. The results clearly show that the formation and evolution of the turbidity maximum play an important role in the sedimentary processes in this environment. The turbidity maximum in the Keum Estuary is primarily related to the tidal range at the mouth and is caused by the resuspension of bottom sediments. In this estuary, the turbidity maximum is not a permanent feature and shows semidiurnal, fortnightly and seasonal variations. Repetition of deposition and resuspension of fine sediments occur in response to the variation in current velocity associated with semidiurnal tidal cycles. The core of turbidity maximum shifts landward or seaward accordion to the flood-ebb succession. The turbidity maximum also shows a fortnightly variation in response to the spring-neap cycles. Thus, the turbidity maximum degenerates during neap-tide and regenerates during spring-tide. The freshwater discharge is also an important factor in the formation and destruction of the turbidity maximum. The increase in freshwater discharge in rainy season can create an ebb-dominant current pattern which enhances the seaward transport of suspended sediments, resulting in the shortening of residence time of suspended materials in the estuary. Thus, under this high discharge condition, the turbidity maximum exists only during spring-tide and starts to disappear as the tidal amplitude decreases.

  • PDF

Biofilter pretreatment for the control of microfiltration membrane fouling

  • Park, Jae-Hyung;Satoshi Takizawa;Hiroyuki Katayama;Shinichiro Ohgaki
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 2003.05a
    • /
    • pp.31-38
    • /
    • 2003
  • A pilot scale biofilter pretreatment-microfiltration system (BF-MF) was operated to investigate the effect of biofilter treatment in fouling reduction of microfiltration. Biofiltration was expected to reduce the membrane fouling by removal of turbidity and metal oxides. The hollow-fiber MF module with a nominal pore size of 0.1$\mu$m and a surface area of 8m$^2$ was submerged in a filtration tank and microfiltration was operated at a constant flux of 0.5 m/d. Biofiltration using polypropylene pellets was performed at a high filtration velocity of 320 m/d. Two experimental setups composed of MF and BF/MF, i.e., without and with biofilter pretreatment, were compared. Throughout the experimental period of 9 months, biofilter pretreatment was effective to reduce the membrane fouling, which was proved by the result of time variations of trans-membrane pressure and backwash conditions. The turbidity removal rate by biofiltration varied between 40% to 80% due to the periodic washing for biofilter contactor and raw water turbidity. In addition to turbidity, metals, especially Mn, Fe and Al were removed effectively with average removal rates of 89.2%, 67.8% and 64.9%, respectively. Further analysis of foulants on the used membranes revealed that turbidity and metal removal by biofiltration was the major effect of biofiltration pretreatment against microfiltration fouling.

  • PDF

Improving the Initial Effluent Water Quality of Rapid Sand Filter by Coagulants Injection (응집제주입에 의한 급속모래여과에서 초기유출수의 수질향상)

  • Kim Woo-Hang;Jeon Ji-Hoon
    • Journal of Environmental Science International
    • /
    • v.15 no.3
    • /
    • pp.237-242
    • /
    • 2006
  • The purpose of this research was to investigate the efficiency of coagulants dose after backwashing. The turbidity of initial effluent was high after backwashing in the rapid sand filtration and the high turbidity was almost removed by coagulants dose into filter-sand after backwashing. It was found that the turbidity of initial effluent was well removed by all kinds of the coagulants used in this study. When filtration was performed input water with differentiated pH's, the turbidity of effluent was low at the range of pH 5 - pH 7. But the removal was not good about over pH 9. This result was considered into the existence forms of aluminium, $Al(OH)^{2+}\;and\;{Al(OH)_2}^+$ at pH 5. Cryptosporidiums of effluent were 4/ml for ten minutes immediately after back washing and 3/ml until sixty minutes. However, the case of coagulant dose after backwashing, Cryptosporidiums of effluent were 0.5/ml for ten minutes with no detection after twenty minutes.

Delineation Of Coastal Features And Relative Turbidity Levels In The Mid West Sea Of Korea Using Landsat Imagery

  • Youn, Oong Koo;Lee, Byung Don;Kwak, Hi-Sang
    • 한국해양학회지
    • /
    • v.11 no.1
    • /
    • pp.9-17
    • /
    • 1976
  • Multispectral scanner data collected by LANDSAT-1 over the mid West Sea of Korea were analyzed and interpreted for delineation of coastal features and turbidity distribution patterns during different portions of the tidal cycle. Imagery from two successful LANDSAT-1 overpasses of the area in October 1972 and in October 1973 had been used to prepare schematic maps of coastal features and turbidity distributions. Color composite imagery of LANDSAT MSS 4, 5 and 7 gave the best representation of shorelines, coastlines and tidal flats. MSS 5 imagery was most effective in differentiating relative turbidity levels through density slicing techniques. Referring to the tidal power development of Garolim Bay, the basin area measurements assuming dyke construction at the bay entrance, have been carried out on the coastal reature maps comiled from LANDSAT imagery, and those results were correlated with existing data. General areal patterns of surface turbidity distribution in the study area revealed close similarity with bathymetry of the area. Synoptic circulation patterns were also well discriminated from the LANDSAT imagery using the suspended sediment as a tracer.

  • PDF

Evaluation of Rapid filtration System with Particle Size Distribution and Turbidity in Different Effective Sizes

  • Park, J.A.;Eo, S.M.;Shin, J.S.;Kim, M.H.;Yu, M.J.;Chung, S.H.
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.381-385
    • /
    • 2005
  • Characterization of particle behavior is becoming more important in performance evaluation of water treatment system as well as in operation of the system because conventional parameter, turbidity has lack of explaining ability on small sized microorganisms such like Cryptosporidium etc. Accordingly, particle counter has been introduced in evaluation and operation of the treatment system. However researches on the relationship between turbidity, particle count and/or different sand/anthracite sizes have not been concurrent. Therefore in this study, the relationship was investigated to improve performance evaluation of sand filter so as to help choosing sand/anthracite effective size as a design parameter of water treatment facility. According to the results, too small or too large effective size media filter reached to turbidity limit(0.1 NTU)earlier. However, because shallow sand layer may cause early breakthrough, the depth of sand layer should be provided enough in order to compromise water quality and productivity.

  • PDF

Simulation of Turbid Water in the Stratified Daecheong Reservoir during Gate Operation (댐 배수조작에 따른 저수지내 탁수변화 모의 - 대청댐을 대상으로 -)

  • Lee, Jae-Yil;Seo, Se-Deok;Lee, Gyu-Sung;Ha, Sung-Ryong
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.377-386
    • /
    • 2009
  • Due to severe flooding, the long-term residence of turbidity flows within the stratified Daecheong Reservoir have lengthened. A long-term residence of turbidity flows within the stratified Daecheong Reservoir after floods has been major environmental issue. The objective of this study was to assess the impact to water supply from the hydrodynamics and turbidity outflow. Two gate operation scenarios were investigated. Scenario A refers to gate operations according to rainfall events, and scenario B refers to gate operations according to inflow. From the results of secenario A, the SS concentrations decreased from 0.44mg/l to 0.54mg/l at the front of the dam, whereas SS concentrations increased from 0.24mg/l to 1.24mg/l at the intake points at Munhi and Daejeon. From the results of scenario B, the SS concentrations decreased from 0.61mg/l to 0.83mg/l at the front of Dam; howeve, SS concentrations also decreased from 0.16mg/l to 0.48mg/l at the intake points at Munhi and Daejeon. It seems that it may be more efficient to control turbidity by creating additional outflows of generated discharge after intensive rainfalls than not.

Control of Turbid Water Transport with Filamentous Mat (섬모상 매트에 의한 탁수이동차단에 관한 실험적 연구)

  • Yu, Jianghua;Yi, Qitao;Kim, Youngchul
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.1
    • /
    • pp.44-51
    • /
    • 2010
  • A lab-scale apparatus for turbid water transport control was tested and examined. The channel had a dimension of $100cm{\times}30cm{\times}15cm$ (length${\times}$hight${\times}$width). And the turbidity water was prepared using two types of particles, bentonite and loess. The channel equipped with filamentous mat was operated under various shock load conditions. In the control channel, instantly, turbid water mixed with the clean water inside the channel and turbidity prevails the entire channel. While in the mat-equipped channel, it increases only at the bottom. Overall, the filamentous mat gave capture efficiency of 70~90% compared with the control group. The capture efficiency of turbid particles decreased with increased input turbidity flux. The result of experimental run on how turbid particles are separated in the mat channel shows that settling, filtration and attachment are the main processes. Meanwhile, turbidity was diffused from the channel bottom due to turbidity gradient before and after mat zone. The particle size before mat zone was lightly coarser than that after mat zone.

Monitoring on Pectinase Treatment Conditions for Clarification of Persimmon Vinegar (감식초 청징화를 위한 Pectinase 처리조건의 모니터링)

  • 정용진;이기동;이명희;여명재;이경훤;최신양
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.28 no.4
    • /
    • pp.810-815
    • /
    • 1999
  • The pectinase treatment conditions for clarification of persimmon vinegar were optimized and monitored by response surface methodology. In clarification of persimmon vinegar by pectinase treatment with variations in temperature, time and concentration, coefficients of determinations(R2) of the models were above 0.91(p<0.05) in turbidity, browning color intensity and tannin content. The turbidity of persimmon vinegar was decreased along with an increase of pectinase treatment temperature. The minimum value of turbidity by pectinase treatment was 0.0021(absorbance at 660nm) in 49.38oC of pectinase treatment temperature, 73.08min of pectinase treatment time and 55.57ppm of pectinase concentration. The minimum value of browning color intensity by pectinase treatment was 0.27(absorbance at 660nm) in 48.39oC, 71.74min and 65.69ppm. The minimum value of total tannin contents by pectinase treatment was 43.72mg/100 ml in 40.05oC, 66.02min and 65.26ppm. The optimum conditions of pectinase treatment that satisfies the least common multiple of turbidity, browning color and tannin content were 40~50oC, 60~70min and 55~70ppm.

  • PDF