• Title/Summary/Keyword: tubing

Search Result 248, Processing Time 0.026 seconds

A Study on Minimizing the Residual $^{18}F$-FDG in the Tubing Using Nitrogen Gas (FDG 합성 후 질소가스를 이용한 튜빙의 잔류 $^{18}F$-FDG 최소화를 위한 방법의 유용성)

  • Kim, Dong-Il;Park, Hoon;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.8-12
    • /
    • 2010
  • Purpose: In $^{18}F$-FDG automated synthesizer, deliver is done in automated mode after synthesis until the dispenser. After the delivery, the yield is calculated from the radioactivity which was read by the dose calibrator located in the dispenser. However, when the distance between the automated synthesizer and the dispenser is far, there are $^{18}F$-FDG residues, which results in loss of the amount of $^{18}F$-FDG. This study investigated the usefulness of a method that minimizes $^{18}F$-FDG residues. Materials and Methods: The structure of the tubing between the (TRACERlab Mx FDG; GE.) and the dispenser is that the distance is 8 m and the internal diameter is 1/16 inch. The synthesis process of The module goes through the synthesis process of trap, synthesis, delivery in the automated module. The time taken for synthesis is about 25 to 26 minutes, after which rinsing is done. However, after rinsing, as the distance of the tubing increased, there were 10~13% of $^{18}F$-FDG residues. Therefore, a method of using push syringe and $N_2$ gas in manual mode to minimize $^{18}F$-FDG residues is analyzed. Results: In manual mode, there were $^{18}F$-FDG residues of 4~5% for the push syringe, and there were $^{18}F$-FDG residues of less than 1% for the $N_2$ gas, which showed that the method using $N_2$ gas had superior usefulness. Also, there were no $^{18}F$-FDG residues in the cleaning the next day. Conclusion: The distance between the synthesizer and the dispenser needs to be reduced as much as possible, to reduce the rate of loss of $^{18}F$-FDG resulting from the distance of the tubing. However, in case the distance between the synthesizer and the dispenser has to be increased due to the system structure, using push syringe and $N_2$ gas simultaneously is a useful method for minimizing $^{18}F$-FDG residues.

  • PDF

Flow Characteristics of Elastin-Like Polypeptide(ELP) Coated Packed Bed (온도 감응성 폴리펩티드로 표면 처리된 충전층의 유동 특성)

  • Kim, Duck-Jong;Lee, Jong-Hwan;Park, Sang-Jin;Hyun, Jin-Ho
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3187-3190
    • /
    • 2007
  • Elastin-Like polypeptide (ELP) composed of elastin-based repeating units is an artificial biomaterial which is biocompatible and non-immunogenic. ELP shows a characteristic inverse phase transition between hydrophobic and hydrophilic phase by external stimuli such as salt, pH and temperature. In this study, ELP coated PS (polystyrene) beads are packed in tubing and the thermo -responsive flow characteristics of the packed bed are investigated. Preliminary test results show that the control of the fluid flow can be achieved by using the temperature driven phase transition effect of the ELP coated beads in a microchannel.

  • PDF

Technique for Soil Solution Sampling Using Porous Ceramic Cups

  • Chung, Jong-Bae
    • Applied Biological Chemistry
    • /
    • v.41 no.8
    • /
    • pp.583-586
    • /
    • 1998
  • Porous ceramic cups are used for monitoring ion concentration in soil solutions in various time course and depth. A soil solution sampler was constructed in laboratory by inserting pliable perfluoroalkoxy(PFA) tubings into porous cup through holes in PVC rod segment which plugged top opening of the porous cup. The system was installed in drip irrigated soil in a vertical position, and nitrogen movement below the drip basin was monitored. To collect soil solution, vacuum in the cup was applied with a hand vacuum pump. The samples obtained were sufficient enough to run quantitative analyses for a number of chemicals. Nitrogen transformation and movement could be well defined, and the system seemed to be relevant to the other soil solution samplers in monitoring chemical movement in soil. Although this system has general deficiencies found in the other samplers using ceramic cup, it could be easily constructed at a low cost. Since the tubing was pliable, the cups could be installed in horizontal position, and this allows installations of the cups at more precise depth increments and also more precise samplings of soil solution at each depth.

  • PDF

Continuous Processing of Monodispersed Zirconia Powders (초음파 혼합 연속공정에 의한 단분산 지르코니아 분체의 합성)

  • Rhee, Jhun;Jo, Dong-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.12
    • /
    • pp.919-925
    • /
    • 1992
  • Continuous synthesis process for monodispersed zirconia powders with ultrasonic wave mixing was developed. Reactant solutions were flowed through a T-tube with small diameter and then mixed in a microscale with ultrasonification. Reaction and aging were followed during the mixed solution of reactants is in plug flowing through a narrow long teflon tubing. Zr(n-OC4H9)4 in ethanol and H2O in ethanol were used as reactants. From this process monodispersed, spherical, non-agglomerated, singlet hydrated zirconia powders with 0.6 $\mu\textrm{m}$ average size were obtained. Geometrical standard deviation of the particle size distribution was less than 1.2 with ultrasonic mixing, and the geometrical standard deviation was not affected by the flow rate of the reactants.

  • PDF

Extractive Butanol Fermentation Using Pervaporation and a Low Acid Producing Strain (투과증발과 유기산 저생성 균주를 이용한 부탄올 추출발효)

  • 윤지용
    • KSBB Journal
    • /
    • v.15 no.4
    • /
    • pp.380-387
    • /
    • 2000
  • An extractive fermentation process using pervaporation was studied in a 7 liter fermentor. Pervaporation was performed using a silicone membrane module and a low-acid-producing strain Clostridium acetobutylicu, B18 was used to produce butanol. In batch culture without pervaporation pH 5.5 and initial glucose concentration of 60 g/L resulted in the highest butanol productivity (0.216 g/L$.$h) with butanol yield of 0.261 Butanol flux through the membrane was best at 2.0 L/min-tubing of air flow rate In batch and fed-batch fermentation glucose consumption rate increased by 1.3 times with pervaporation.

  • PDF

Development of Innovative Neutron Flux Mapping System (혁신적인 중성자 속 분포 측정 시스템의 개발)

  • 조병학;신창훈;변승현;박준영;양장범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.60-63
    • /
    • 2004
  • An innovative in-core neutron flux mapping system has been developed and applied successfully for service in a commercial pressurized water reactor. With the benefit of double indexing path selector (Dip $s^{ⓡ}$) mechanism, the reliability of the detector drive system has been improved five times higher than that of conventional systems, and the problems caused by the serious friction generated between the detector cable and guide tubing has been solved completely because the Dip $s^{ⓡ}$ architecture allows the detector guide tubings to have larger curvature and shorter length in nature. The simple and fast maintenance is particularly emphasized in the detector drive system to secure minimum radiation exposure to the maintenance personnel by optimizing the number of components and providing easy access to the components. The programmable logic controller based digital controller with Window $s^{ⓡ}$ based operator s console provides fully automated and user friendly operation and maintenance support means.

  • PDF

Use of New Passive Sampler to Assess PAHs Contamination (새로운 생물농축 기법에 의한 PAHs의 오염도 확인)

  • 박정규;황인영;문성환;정홍배
    • Environmental Analysis Health and Toxicology
    • /
    • v.16 no.4
    • /
    • pp.171-179
    • /
    • 2001
  • A new passive sampler was developed, improving SPMD (Semipermeable Membrane Devices) that contained triolein in nonporous, low-density polyethylene layflat tubing. Experiments to measure PAHs concentration were carried out at four sites (Dukpo, Sochi, Sohwonggando, Yeonmok) on the southern coast of Korea that were contaminated by oil spills. Passive samplers were deployed at 4 and 8 week intervals at each site. Results showed that bioconcentration levels of PAHs were increased in proportion to exposure duration from all sample sites and accumulation in the passive sampler was much higher than in biota at the Dukpo site. Results of these tests suggest that new passive sampler is a useful tool for measuring bioconcentration organic compounds in aquatic environments.

  • PDF

The protective effect of Red Giseng on the organotin compounds(TBTO) poison : Focusing on the Immunity and sex hormone (유기주석화합물의 독성에 대한 홍삼의 방어효과 - 면역 및 성 호르몬물질 중심으로 -)

  • 최한영
    • Journal of environmental and Sanitary engineering
    • /
    • v.16 no.3
    • /
    • pp.8-13
    • /
    • 2001
  • This study was carried out effect of red ginseng extract(1.0g/kg) on organotin compounds (10, 20 and 40 mg/kg) which poisons against some organs like thyroid gland, liver, kindey, testis, ovary, serum immuinty and sex hormone activity of rats were examinned by gastric tubing for 3 weeks. The weight of each organ in TBTO treated group were significantly increased other organs which excepted kinedy in males and only liver in females.(p<0.05, p<0.01). In case of Immunity activity of each sex, IgM level was small change comparsion with that of control group in all sex. but IgG level was significantly decreased females rather than males comparsion with that of control group.(p<0.05, p<0.01) In case of sex hormone activity, the testosterone activity of males and the estradiol activity of females were significantly decreased rather than the control group. on the other hand, red singsong treated group was only significantly increased estradiol activity.( p<0.05, p<0.01)

  • PDF

High Temperature Size Exclusion Chromatography for High Throughput Analysis

  • Chang, Tai-Hyun;Park, Soo-Jin;Cho, Hee-Sook;Kim, Young-Tak;Ihm, Kyu-Hyun
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.202-202
    • /
    • 2006
  • With a modern size exclusion chromatography (SEC) column, molecular weight analysis of a polymer sample takes about 10 min. However, it is desirable to reduce the analysis time further, in particular, for high throughput measurements required in combinatorial analyses or 2D-HPLC analyses. We implemented the high temperature SEC for the purpose. By inserting a narrow bore tubing between the column and the detector, a sufficient backpressure can be maintained to prevent the mobile phase from boiling and the effluent is cooled down enough when it reaches the detector. Therefore, a normal SEC detector can be used without any modification. The SEC resolution is greatly improved at the elevated temperature at high flow rate which allows high speed operation.

  • PDF

Blood Conservation in Coronary Artery Bypass Surgery - in 24 consecutive patients - (관상동맥 우회로술 환자에서 혈액 보존법)

  • 최종범
    • Journal of Chest Surgery
    • /
    • v.25 no.10
    • /
    • pp.1048-1054
    • /
    • 1992
  • With use of a simple, inexpensive and nonpharmacological program for blood conservation, 24 consecutive patients underwent elective or urgent coronary artery bypass grafting without need of homologous red cell transfusions and /or fresh frozen plasma transfusions in 16 patients[66.7%]. Left internal mammary artery graftings were done in 18 patients[75%], with supplemental saphenous vein grafts in all. Intraoperatively, autologous heparinized blood was removed before bypass and retransfused at the conclusion of ext-racorporeal circulation. The volume remaining in the oxygenator and tubing set was returned without cell processing or hemofiltration. Using the hard-shell cardiotomy reservoir from the oxygenator, autotransfusion of the shed mediastinal blood was continued hourly by the next early;norning. The mean postoperative mediastinal blood loss was 364$\pm$234ml, whereas 553$\pm$383ml was autotransfused. 4 patients [16.7%] received homologous blood and an additional 4 patients[16.7%] fresh frozen plasma. Thus, in total, 16 patients[66.7%] were not exposed to any homologous blood products during the hospital stay. At discharge, the mean hemoglobin concentration was 10.3$\pm$1.6g /dl. Postoperative complications were few and there was no hospital death.

  • PDF