• Title/Summary/Keyword: tube internal

Search Result 591, Processing Time 0.033 seconds

A human case of internal myiasis in Korea (내부 승저증(internal myiasis) 1례)

  • 정평림;정영헌
    • Parasites, Hosts and Diseases
    • /
    • v.34 no.2
    • /
    • pp.151-154
    • /
    • 1996
  • A 71-year old male patient was admitted in Inha hospital due to right facial palsy, quadriplegia and aphasia. This patient was operated to replace his heart valves 7 years ago and has been treated with Coumarin. an anti-coagulant drug. to prevent the formation of thrombus in the hpart. A number of fly maggots continuoully crawled out from the nasogastric tube set up for supplying a liquid diet and patient's mouth for 2 days until his death in the intensive care unit of hospital. These maggots were about 11.5 mm long on the average and identified as genus Lucilio belonging to family Calliphoridae. The lesion of this myiasis case might be regarded in the castro-intestinal . System of patient. This is the first report of an internal myiasis case in Korea.

  • PDF

Effect of Octreotide on Patients with Malignant Bowel Obstruction (악성장폐색 환자에서 Octreotide의 치료 효과)

  • Park, Ji-Chan;Jang, Yi-Sun;Jeon, Eun-Kyoung;Kim, Dong-Kyu;Lee, Wook-Hyun;Lee, Guk-Jin;You, Si-Young;Choi, Hyun-Ho;Park, Suk-Young
    • Journal of Hospice and Palliative Care
    • /
    • v.12 no.4
    • /
    • pp.194-198
    • /
    • 2009
  • Department of Internal Medicine, The Catholic University of Korea College of Medicine, Seoul, Korea Purpose: Malignant bowel obstruction causes gastrointestinal symptoms and leads to diminished quality of life in patients with advanced cancer. Several studies have shown the efficacy of octreotide for the relief of malignant bowel obstruction-related symptoms. The aim of this study is to assess the efficacy and safety of octreotide in patients with malignant bowel obstruction. Methods: We retrospectively reviewed medical records of twenty nine patients who had suffered from malignant bowel obstruction without clinical improvement of conservative care and subsequently, received octreotide treatment. Initial dosage of octreotide was 0.1 mg/day, and dose was escalated depending on the clinical effect. For each patient, we assessed visual analogue scale (VAS) of pain, number of vomiting episode, and amount of nasogastric tube drainage. Results: Median dosage of octreotide was 0.2 mg/day (range 0.1~0.6), and median duration from initial medication to death was 20 days (range 2~103). VAS before and after octreotide treatment were 5.6$\pm$1.24, and 2.7$\pm$0.96, respectively. The numbers of vomiting episode before and after octreotide treatment were 3.6/day$\pm$2.5, and 0.4/day$\pm$0.8, respectively. The mean amounts of nasogastric tube drainage before and after octreotide treatment were 975$\pm$1,083 cc/day and 115$\pm$196 cc/day, respectively. Statistically significant reduction in VAS, the number of vomiting episode and the amount of nasogastric tube drainage were observed after octreotide treatment (P<0.05). Conclusion: Administration of octreotide in patients with malignant bowel obstruction, which is uncontrolled by other medication, was effective and safe. In such clinical situations, physicians should consider to add of octreotide for symptomatic control.

  • PDF

Preliminary Study on Optimization of the Tube Hydroforming Process Using the Equivalent Static Loads (등가정하중을 이용한 튜브 하이드로포밍 공정 최적설계에 관한 기초연구)

  • Jang, Hwan-Hak;Park, Gyung-Jin;Kim, Tai-Kyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.3
    • /
    • pp.259-268
    • /
    • 2015
  • An optimization method for the tube hydroforming process is developed using the equivalent static loads method for non linear static response structural optimization (ESLSO). The aims of the tube hydroforming optimization are to determine the axial forces (axial feedings) and the internal pressures, and to obtain the desired shape without failures after hydroforming analysis. Therefore, the magnitude of the forces should be design variables in the optimization process. Also, some tube hydroforming optimization needs to consider the result of the thickness in nonlinear dynamic analysis as responses. However, the external forces are considered as constants and the thickness is not a response in the linear response optimization process of the original ESLSO. Thus, a new ESLSO process is proposed to overcome the difficulties and some examples are solved to validate the proposed method.

Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists

  • Porcel, Jose M.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.81 no.2
    • /
    • pp.106-115
    • /
    • 2018
  • Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (${\leq}14F$) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established.

Study on NOx Reduction with Multi-Perforated Tube Geometry in Integrated Urea-SCR Muffler (촉매삽입형 Urea-SCR 머플러 다공튜브 형상변화에 따른 NOx 저감 특성에 관한 연구)

  • Moon, Namsoo;Lee, Sangkyoo;Ko, Sangchul;Lee, Jeekeun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.12
    • /
    • pp.1017-1026
    • /
    • 2014
  • A multi-perforated tube is generally installed between the muffler inlet and in front of selective catalytic reduction (SCR) catalysts in the integrated urea-SCR muffler system in order to disperse the urea-water solution spray uniformly and to make better use of the SCR catalyst, which would result in an increase nitrogen oxide ($NO_x$) reduction efficiency and a decrease in the ammonia slip. The effects of the multi-perforated tube orifice area ratios on the internal flow characteristics were investigated analytically by using a general-purpose commercial software package. From the results, it was clarified that the multi-perforated tube geometry sensitively affected the generation of the bulk swirling motion inside the plenum chamber set in front of the SCR catalyst and to the uniformity index of the velocity distribution produced at the inlet of the catalyst. To verify the analytical results, engine tests were carried out in the ESC and ETC modes. Results of these tests indicated that the larger flow model in the longitudinal direction showed the highest NOx reduction efficiency, which was a good agreement with the analytical results.

Corrosion Failure Analysis of the Convection Part of District Heating Peak Load Boiler (지역난방 첨두부하보일러 대류부 부식 파손 분석)

  • Kim, Youngsu;Chae, Hobyung;Hong, Minki;Song, Min Ji;Cho, Jeongmin;Kim, Woo Cheol;Ha, Tae Baek;Lee, Soo Yeol
    • Corrosion Science and Technology
    • /
    • v.18 no.2
    • /
    • pp.55-60
    • /
    • 2019
  • Corrosion failure in the convection part of peak load boiler (PLB) of the district heating system led to water leakage. Herein, Internal Rotary Inspection System (IRIS) inspection was employed to examine wall thinning and the cause of leakage in the flue tube. The corrosive products of the turbulator and tube were investigated using scanning electron microscope combined with energy dispersive spectroscopy, X-ray diffraction, and inductively coupled plasma (ICP). Majority of the serious corrosion damage was observed near the turbulator located in the upper flue tube. ICP analysis of the boiler water revealed oxide formation of sodium chloride in the lower end part of the flue tube. A cross-sectional view of the turbulator revealed the presence of double-layers of the oxide film, indicating environmental change during operation associated with water leakage. The outer surface of the turbulator consisted of the acid oxides such as $NO_x$ and $SO_x$ along with sodium and chloride ions. Dew-point corrosion is hypothesized as the main cause for the formation of acid oxides in the region of contact of the flue tube and the turbulator.

The evaluation of image-guided catheter drainage in pleural effusion and empyema (흉수 및 농흉에서의 영상유도하 도관배액술의 유용성 평가)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.3
    • /
    • pp.403-409
    • /
    • 1996
  • Background : Pleural fluid collections may pose a difficult therapeutic problem. Complete drainage of complicated effusions or empyemas and reexpansion of atelectatic lung are important in obtaining a satisfactory clinical outcome. The usual approach to the diagnosis and treatment of patients with pleural effusion and empyema has been with needle thoracentesis and chest tube drainage. With chest tube drainage, technical difficulties and failures may occur as a result of improper tube drainage, particularly when there is a loculation or multiple and inaccesible collections. Fluoroscopic or sonographic guidance facilitates the proper tube insertion and drainage. Method : Twenty eight patients were required for tube drainage due to pleural fluid collections between January 1994 to February 1996. The author compared the results of drainage under applying each different method between blind chest tube insertion and image guided catheter insertion. Results : The conventional blind chest tube group comprised 14 patients; 6 empyema, 6 tuberculous effusion, and 2 parapneumonic effusion. The image guided catheter group of smaller french were composed of 14 patients; 2 empyema, 6 tuberculous effusion, 5 parapneumonic effusion, and 1 effusion of undetermined origin. Radiologic improvement with successful drainage was noticed in 79% with the blind chest tube group, whereas in 93% with the image guided catheter group. The complication with the latter method was unremarkable. Conclusion : Image guided catheter drainage was safe and highly successful in treating patients, not only with complicated effusion also with loculated empyema. Image guided catheter drainage offers an alternative in patients in whom closed drainage is required as the initial treatment.

  • PDF

A Case of Human Pulmonary Dirofilariasis in a 48-Year-Old Korean Man

  • Kang, Hyo Jae;Park, Young Sik;Lee, Chang-Hoon;Lee, Sang-Min;Yim, Jae-Joon;Yoo, Chul-Gyu;Kim, Young Whan;Han, Sung Koo;Chai, Jong-Yil;Lee, Jinwoo
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.5
    • /
    • pp.569-572
    • /
    • 2013
  • Dirofilariasis is a rare disease in humans. We report here a case of a 48-year-old male who was diagnosed with pulmonary dirofilariasis in Korea. On chest radiographs, a coin lesion of 1 cm in diameter was shown. Although it looked like a benign inflammatory nodule, malignancy could not be excluded. So, the nodule was resected by video-assisted thoracic surgery. Pathologically, chronic granulomatous inflammation composed of coagulation necrosis with rim of fibrous tissues and granulations was seen. In the center of the necrotic nodules, a degenerating parasitic organism was found. The parasite had prominent internal cuticular ridges and thick cuticle, a well-developed muscle layer, an intestinal tube, and uterine tubules. The parasite was diagnosed as an immature female worm of Dirofilaria immitis. This is the second reported case of human pulmonary dirofilariasis in Korea.

The Effect of Cooling Efficiency on Fouling by EGR Cooler Internal Shape (EGR Cooler 내부 형상에 따른 Fouling이 냉각 성능에 미치는 영향)

  • Nam, Youn-Woo;Oh, Kwang-Chul;Lee, Chun-Hwan;Lee, Chun-Beom;Lee, Won-Nam
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.1
    • /
    • pp.101-108
    • /
    • 2011
  • Understanding the exhaust gas recirculation (EGR) cooler fouling in diesel engine is important factor in the durability characteristic of a EGR system. We develope a test rig and PM feeder using carbon black to examine the effect of fouling on EGR cooler devices those were consisted of flat and shell & tube type. The EGR cooler fouling process is a complex interaction involving heat exchanger shape, boundary condition, constitutes, chemistry and operating mode. As the soot deposited to EGR cooler, these formed a thin deposit layer that was less heat exchange than the fresh status of tube enclosing the exhaust gas, resulting in lower heat exchange effectiveness in both type coolers. But these deposits caused different results in pressure drop, it is increased in flat type, but decreased in Shell & tube type of EGR cooler. A cause was estimated from a change of the flow structure and a decrease of contact area as the EGR cooler fouling.

Remote Field Energy Flow Path at Nonmagnetic Coaxial Tubes (비자성체 이중관의 원격장 에너지 전달 경로)

  • Yi, Jae-Kyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.5
    • /
    • pp.526-531
    • /
    • 2001
  • The flow of remote field eddy current energy is studied at nonmagnetic coaxial tubes by using both experiments and finite element calculations based on commercial software package. The results showed that remote field eddy current energy at coaxial tubes flow along over the outer surface of external tube, not through the gap between internal and external tubes. This means that the through wall transmission characteristic of remote field eddy current testing (RFECT) is still valid at tube in tube configurations and the RFECT could be potential nondestructive technique for crack detection, spacer location and gap sizing at the coaxial CANDU fuel channel tubes.

  • PDF