• 제목/요약/키워드: tube current

검색결과 921건 처리시간 0.026초

Anatomy of a flare-producing current layer dynamically formed in a coronal magnetic structure

  • Magara, Tetsuya
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.41.3-42
    • /
    • 2016
  • No matter how intense magnetic flux it contains, a coronal magnetic structure has little free magnetic energy when a composing magnetic field is close to a potential field, or current-free field where no volume electric current flows. What kind of electric current system is developed is therefore a key to evaluating the activity of a coronal magnetic structure. Since the corona is a highly conductive medium, a coronal electric current tends to survive without being dissipated, so the free magnetic energy provided by a coronal electric current is normally hard to release in the corona. This work aims at clarifying how a coronal electric current system is structurally developed into a system responsible for producing a flare. Toward this end, we perform diffusive MHD simulations for the emergence of a magnetic flux tube with different twist applied to it, and go through the process of structuring a coronal electric current in a twisted flux tube emerging to form a coronal magnetic structure. Interestingly, when a strongly twisted flux tube emerges, there spontaneously forms a structure inside the flux tube, where a coronal electric current changes flow pattern from field-aligned dominant to cross-field dominant. We demonstrate that this structure plays a key role in releasing free magnetic energy via rapid dissipation of a coronal electric current, thereby producing a flare.

  • PDF

소아 CT 촬영시 방사선 피폭과 저감화 방법 (Medical Radiation Exposure in Children CT and Dose Reduction)

  • 이정근;장성주;장영일
    • 한국콘텐츠학회논문지
    • /
    • 제14권1호
    • /
    • pp.356-363
    • /
    • 2014
  • 소아 CT 촬영시 피폭선량을 저감시킬 수 있는 조건을 찾기 위하여 pediatric phantom을 이용하여 소아 방사선량을 비교 분석하였다. 관전류변동제어(tube current modulation:TCM) 방식과 low dose CT protocol(LDCTP)에 따라 소아 검사를 시행하였으며, 검사는 brain, chest, abdomen-pelvis 부위를 전산화 단층촬영 장치를 이용한 3개의 검사 프로토콜을 사용하였다. 거의 모든 MDCT 장치는 volume CT dose index(CTDIvol), dose length product(DLP)와 유효선량 평가 결과를 기록, 보관하고 있으며, 이러한 정보들은 환자들의 방사선 노출 및 위험도를 평가하는 데 필수적이다. 방사선 노출 위험도를 감소시키기 위해서 적정화 및 정당화 원칙을 반드시 준수해야 한다. 관전압(kV)에 따른 TCM 방식을 사용하였을 경우 kV가 낮아질수록 유효선량이 낮아지는 경향을 나타내었으며, low dose CT protocol을 사용한 경우가 유효선량이 상대적으로 더 적은 것을 알 수 있었다. 또한 평균 유효선량은 brain, chest, abdomen-pelvis CT의 결과가 독일의 reference dose 보다 각각 47%, 13.8%, 25.7%로 더 낮게 나타났고. 영국의 reference dose와 비교해도 55.7%, 10.2%, 43.6%에 불과했다. 결론적으로 선량 감소를 위해 주의할 것은 body-weight based tube current adaption을 포함한 TCM, 그리고 LDCTP 등 모든 선량 감소 방안을 이용하여야 한다.

초소형 튜브와 튜브판의 링 프로젝션 용접 공정개발 및 강도 평가 (Development and Strength Evaluation of Ring Projection Welding Process of the Microminiature Tube and Tubesheet)

  • 윤영현;김현준;김창수;조상명
    • Journal of Welding and Joining
    • /
    • 제27권2호
    • /
    • pp.63-68
    • /
    • 2009
  • Microminiature heat exchanger has been applied to the gas turbine in order to increase energy efficiency. During the production of microminiature heat exchanger, however, it is very difficult to weld tube to tubesheet. In this study, therefore, welding process of resistance ring projection was used, and weld tensile tests were performed. Sound weld joint was obtained as a result of applying resistance ring projection welding to microminiature heat exchanger to tubesheet. Cold weld occurred at under 1600A. Even though tensile strength was increased with increasing current, splash occurred and tensile strength decreased at 2000A due to the excessive current. Therefore it was determine that the optimal current is 1900A. As result of tensile tests based on ASME code for tube to tubesheet weldment, rupture position was weldment due to Fs(Fractured section) of nugget, which was smaller than tube thickness (t), and it was proven as a partial strength welding because of the average joint efficiency fr = 0.90.

Effects of Physical Factors on Computed Tomography Image Quality

  • Jeon, Min-Cheol;Han, Man-Seok;Jang, Jae-Uk;Kim, Dong-Young
    • Journal of Magnetics
    • /
    • 제22권2호
    • /
    • pp.227-233
    • /
    • 2017
  • The purpose of this study was to evaluate the effects of X-ray photon energy, tissue density, and the kernel essential for image reconstruction on the image quality by measuring HU and noise. Images were obtained by scanning the RMI density phantom within the CT device, and HU and noise were measured as follows: images were obtained by varying the tube voltages, the tube currents and eight different kernels. The greater the voltage-dependent change in the HU value but the noise was decreased. At all densities, changes in the tube current did not exert any significant influence on the HU value, whereas the noise value gradually decreased as the tube current increased. At all densities, changes in the kernel did not exert any significant influence on the HU value. The noise value gradually increased in the lower kernel range, but rapidly increased in the higher kernel range. HU is influenced by voltage and density, and noise is influenced by voltage, current, kernel, and density. This affects contrast resolution and spatial resolution.

A Study on 3-Dimensional Profilometry of Steam Generator Tube Using a New Eddy Current Probe

  • Kim, Young-Kyu;Song, Myung-Ho;Choi, Myung-Sik
    • 비파괴검사학회지
    • /
    • 제30권3호
    • /
    • pp.225-235
    • /
    • 2010
  • There are many types of the geometric transitions such as dent, bulge, protrusion, expansion, etc, on the inner and outer surfaces of heat exchanger tubes, steam generator tubes, and condenser tubes of nuclear power plants. Such geometric transition causes a local residual stress in heat exchanger tubes and acts as a structural factor accelerating the evolution of defects, in particular stress corrosion cracks. In the conventional eddy current test methods, the bobbin coil profilometry can provide 2-dimensional geometric information on the variation of the average inner diameter along the tube length, but the 3-dimensional distribution and the quantitative size of a local geometric transition existing in the tube cannot be measured. In this paper, a new eddy current probe, developed for the 3-dimensional profile measurement, is introduced and its superior performance is compared with that from the conventional bobbin coil profilometry for the various types of geometric transition. Also, the accuracy of the probe for the quantitative profile measurement is verified by comparing the results with that from the laser profilometry. It is expected that the new eddy current probe and techniques can be effectively used for an optimization of the tube expansion process, and the management of tubes with geometric transitions in service.

배열형 탐촉자를 이용한 증기발생기 세관 검사 적용성 검토 (A Study on Applying Array Probe for Steam Generator Tube Inspection)

  • 김인철;천근영;이영호
    • 한국압력기기공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.25-31
    • /
    • 2009
  • Steam Generator(SG) tube is an important component of Nuclear Power Plant(NPP), which comprises of the pressure boundary of primary system. The integrity of SG tube has been confirmed by the eddy current test every outage. In Korea, Bobbin probe and MRPC probe have been generally used for the eddy current test. Meanwhile the usage of Array probe has gradually increased in U.S., Japan and other countries. In this study, we investigated the defect detection capability of the Array probe through its preliminary application to SG tube inspection. The Array probe has the equivalent capability in the defect detection and sizing as the conventional methods. Thus it is desirable that the Array probe is generally applied to SG tube inspection in the domestic NPPs.

  • PDF

Magnetic Interference on the Infrastructure for a Super-speed Tube Train

  • Lee, Hyung-Woo;Jang, Seung-Yup;Kang, Bu-Byoung;Cho, Su-Yeon;Lee, Ju
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권3호
    • /
    • pp.364-368
    • /
    • 2011
  • The super-speed tube train was introduced to increase the speed of ground transportation. It levitates magnetically and runs in a partial vacuum tube, which significantly reduces air resistance. However, strong magnetic force sufficient to propel the massive train can affect the infrastructure. The induced eddy current produces joule heat, and raises the inside temperature of the girder, which might lead to electrochemical corrosion on the girder, thereby weakening its durability. In this paper, the authors analyzed the magnetic flux and induced eddy current in the reinforced concrete girder by using three-dimensional FEM, particularly by varying the number of reinforcing steels of the upper flange of the girder to the condition of almost the same flexural strength and reinforcing steel amount.

온도 변화에 따른 X-선진단장치의 관전압, 관전류, 조사선량에 관한 연구 (A Study of x-ray tube voltage, tube current and dose rate depeding on temperature)

  • 전기환;황민선;최면웅;이송이;김민지;양동일;이귀열
    • 한국항행학회논문지
    • /
    • 제15권2호
    • /
    • pp.264-272
    • /
    • 2011
  • X-ray를 연속하여 촬영함에 따라서 튜브의 내부온도가 올라가게 되고 거기에 비례하여 mA값과 조사선량이 증가하게 된다. 자연히 X-선 방출량도 많아지게 됨에 따라 임상적으로는 물론이고 환자의 피폭선량에 영향을 미치는 결과를 가져온다. 특히 방사선 성능검사에서 합격 혹은 불합격의 오차범위에 영향을 받는다고 볼 수 있다. 본 논문에서는 온도 차이에 따른 X-선 진단장치의 관전압, 관전류 및 조사선량의 변화에 관한 연구를 수행하였다. X-선 진단장치 검사 중 과도한 사용으로 인한 관전류의 오차을 막고 환자의 피폭을 줄여 보다 효과적으로 X-선 진단장치를 사용하도록 하였다. 연구 결과 튜브의 수명을 연장시킴으로서 병원의 재정에 많은 도움이 될 것으로 사료된다.

증기발생기 전열관 와전류검사용 국내 개발 보빈탐촉자 적용성 분석 (Determination of Availability of Domestic Developed Bobbin Probe for Steam Generator Tube Inspection)

  • 김인철;주경문;문용식
    • 한국압력기기공학회 논문집
    • /
    • 제7권4호
    • /
    • pp.19-25
    • /
    • 2011
  • Steam Generator(SG) tube is an important component of Nuclear Power Plant(NPP), which is the pressure boundary between the primary and secondary systems. The integrity of SG tube has been confirmed by the eddy current test every outage. The eddy current technique adopting bobbin probe is currently the primary technique for the steam generator tubing integrity assesment. The bobbin probe is one of the essential components which consist of the whole ECT examination system and provides us a decisive data for the evaluation of tube integrity. Until now, all of the ECT bobbin probes in Korea which is necessary to carry out inspection are imported from overseas. However, KHNP has recently developed the bobbin probe design technology and transferred it to domestic manufacturers to fabricate the probes. This study has been conducted to establish technical requirements applicable to the steam generator tube inspection using the bobbin probes fabricated by the domestic manufactures. The results have been compared with the results obtained by using foreign probe to identify the availability to the steam generator tube inspection. As a result, it is confirmed that the domestic bobbin probe is generally applicable to SG tube inspection in the NPPs.