• 제목/요약/키워드: tube

검색결과 11,436건 처리시간 0.043초

FLUID-ELASTIC INSTABILITY OF ROTATED SQUARE TUBE ARRAY IN AN AIR-WATER TWO-PHASE CROSSFLOW

  • CHUNG HEUNG JUNE;CHU IN-CHEOL
    • Nuclear Engineering and Technology
    • /
    • 제38권1호
    • /
    • pp.69-80
    • /
    • 2006
  • Fluid-elastic instability in an air-water two-phase cross-flow has been experimentally investigated using two different arrays of straight tube bundles: normal square (NS) array and rotated square (RS) array tube bundles with the same pitch-to-diameter ratio of 1.633. Experiments have been performed over wide ranges of mass flux and void fraction. The quantitative tube vibration displacement was measured using a pair of strain gages and the detailed orbit of the tube motion was analyzed from high-speed video recordings. The present study provides the flow pattern, detailed tube vibration response, damping ratio, hydrodynamic mass, and the fluid-elastic instability for each tube bundle. Tube vibration characteristics of the RS array tube bundle in the two-phase flow condition were quite different from those of the NS array tube bundle with respect to the vortex shedding induced vibration and the shape of the oval orbit of the tube motion at the fluid-elastic instability as well as the fluid-elastic instability constant.

알루미늄/GFRP 혼성 사각튜브의 정적 압축 붕괴 및 에너지 흡수 특성 (Axial crush and energy absorption characteristics of Aluminum/GERP hybrid square tube)

  • 김구현;이정주
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 1999년도 추계학술발표대회 논문집
    • /
    • pp.168-171
    • /
    • 1999
  • For the axial crushing tests of various shape of tubes, it was reported that composite tubes need trigger mechanism to avoid brittle failure. In this study, static axial crush tests were performed with the new aluminum/GFRP hybrid tubes. Glass/Epoxy prepregs were wrapped around aluminum tube and co-cured. The failure of hybrid tube was stable and progressive without trigger mechanism, and specific energy absorption was increased to maximum 34% in comparison with aluminum tube. Effective energy absorption is possible for inner aluminum tube because wrapped composite tube constrain the deflection of aluminum tube and reduce the folding length. The failure of hybrid composite tube was stable without trigger mechanism because inner aluminum tube could play the role of crack initiator and controller. Aluminum/Glass-Epoxy hybrid tube is suitable for the vehicle front structure due to effective energy absorption capability, easy production, and simple application for RTM process.

  • PDF

고온에서 이중튜브의 열응력특성해석 (Analysis of the Stress Characteristics of Double Layered Tube at Elevated Temperature)

  • 김은화;장정환;박성필;문영훈
    • 소성∙가공
    • /
    • 제19권7호
    • /
    • pp.405-410
    • /
    • 2010
  • Double layered tube that has been used for transportation and oil piping system is occasionally exposed to elevated temperature. The change in stress state at elevated temperature is important for the safe design of double layered tube. In this study, the variation of stress state for hydroformed double layered tube of which inner tube is stainless steel and outer tube is mild steel has been analytically analyzed. To characterize the thermal stress at elevated temperature, analytical model to provide thermal stresses between outer tube and inner tube was developed by using theories of elasticity and Lame equation. The feasibility of analytical model is verified by finite element analysis using ANSYS $CLASSIC^{TM}$, commercially available code. The variation of thermal stress at various thickness combination of inner and outer tube has also been investigated by proposed analytical model.

소형 관성관 맥동관 냉동기의 단열 해석 및 성능 실험 (Adiabatic analysis and performance experiment of miniature inertance pulse tube refrigerator)

  • 남중원;남관우;정상권
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.28-32
    • /
    • 2003
  • Miniature inertance pulse tube refrigerator was designed and fabricated to provide optimal performance with 10W compressor. An adiabatic model was used to design an inertance pulse tube refrigerator. Among the various design parameters which should be optimized, pulse tube length and inertance tube length were considered. PdV work and various losses were calculated for various pulse tube and inertance tube length. Experiments were carried out for different pulse tube length and inertance tube length. It was shown that the experimental results were similar to the calculated results. The reason why the quantitative optimal point exists is explained.

  • PDF

RIPPLE TUBE의 열전달(熱傳達) 특성(特性)에 관(關)한 실험적(實驗的) 연구(硏究) (An Experimental Study on Heat Transfer Characteristics of a Ripple Tube)

  • 최승성
    • 설비공학논문집
    • /
    • 제2권4호
    • /
    • pp.316-326
    • /
    • 1990
  • The measurements of heat transfer and pressure drop were performed on ripple tube with air flow. The results with the tube were compared with the performance of smooth tube. The enhancements in heat transfer coefficient for ripple tube, being compared with smooth tube, was ranged from 7.4 to 39 percent. The local Nusselt number for the inner fin tube, being compared with that for smooth tube, varied from 7.4% to 39%, while the corresponding increase in friction factors were 4.1 to 8.1%. One of the most direct indications of Nusselt number of ripple tube is given as following equation: $$Nu=0.061Re^{0.75}Pr^{0.4}(Tb/Tw)^{0.5}$$ We can see that Nusselt number for ripple tube in this experiment is consistent with the theoretical one taken from Walkinson's equation at Reynolds number range from 8,000 to 20,000.

  • PDF

승용차용 브레이크 Tube-End의 최적설계에 관한 연구 (A Study on the Optimal Design of the Brake Tube-End for Automobiles)

  • 한규택;박정식
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2002년도 추계학술대회 논문집
    • /
    • pp.53-57
    • /
    • 2002
  • Brake tube is considered one of the most important parts in automobile. The shape of brake tube-end has a great influence on the function of brake, and the quality and productivity of brake tube have relation to die design. The forming process of brake tube-end is peformed by hydraulic press forming machine. In this paper, the forming processes of tube-end for automobile is analyzed and designed to make the optimal form of brake tube-end. Also, finite element analysis has been carried out using DEFORM-3D$\^$TM/ to predict the optimal shape of brake tube-end and the results obtained showed the optimal length between punch and chuck is 1.0 ∼ 1.2mm. The shape of tube-end is in good agreement with the finite element simulations and the experimental results.

  • PDF

A Study on the Perforating Process of the Muffer Tube using FEM

  • Han Kyu-Taek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권3호
    • /
    • pp.275-280
    • /
    • 2005
  • Recently there has been a growing interest in the design and manufacturing of the muffler tube due to the strict environment regulations, A muffler is an important part used to reduce noise and to purify exhaust gas in cars and heavy equipment. The shape of the muffler tube and the number of the tube hole has been made variously according to the weight and function of the car. The perforating technique of the muffler tube has a great influence on the manufacturing cost. In this study, metal forming analysis has been carried out to investigate the perforating process for the muffler tube and predict an optimal forming conditions of the muffler tube, Also its simulation results by the finite element method were reflected to the die design and the manufacturing system for the muffler tube. The perforating process is performed in the longitudinal direction of the tube. According to the simulation results, when the shear angle of punch was similar to the tube curvature, the optimal shape was obtained. Also when the clearance of die was 0.2mm, the burr was minimized and optimal shear section was obtained.

Flow-induced instability and nonlinear dynamics of a tube array considering the effect of a clearance gap

  • Lai, Jiang;Sun, Lei;Li, Pengzhou
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1650-1657
    • /
    • 2019
  • Fluidelastic instability and nonlinear dynamics of tube bundles is a key issue in a steam generator. Especially, once the post-instability motion of the tube becomes larger than the clearance gap to other tubes, effective contact or impact between the tubes under consideration and the other tube inevitable. There is seldom theoretical analysis to the nonlinear dynamic characteristics of a tube array in two-phase flow. In this paper, experimental and numerical studies were utilized to obtain the critical velocity of the flow-induced instability of a rotated triangular tube array. The calculation results agreed well with the experimental data. To explore the post-instability dynamics of the tube array system, a Runge-Kutta scheme was used to solve the nonlinear governing equations of tube motion. The numerical results indicated that, when the flow pitch velocity is larger than the critical velocity, the tube array system is undergoing a limit cycle motion, and the dynamic characteristics of the tube array are almost similar for different void fractions.

Experimental results of Stilting type Pulse Tube refrigerator with inertance tube

  • Hong, Yong-Ju;Park, Seong-Je;Kim, Hyo-Bong;Koh, Deuk-Yong;Park, Young-Don
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권1호
    • /
    • pp.118-122
    • /
    • 2003
  • Pulse tube refrigerator, which has no moving parts at its cold section, is attractive fer obtaining higher reliability, simpler construction and lower vibration than Stilting refrigerator or Gifford-McMahon refrigerator. Commonly used means to achieve optimum performance of Stilting type pulse tube refrigerator is an inertance tube. The use of inertance tube is a simple way to generate the phase shift needed to make pulse tube refrigerator operate as efficiently as Stilting refrigerator. In this study, the performance of the inertance pulse tube refrigerator (IPTR) was investigated experimentally. An in-line type IPTR consists of a linear compressor with two reciprocating pistons driven by linear motors, which makes pressure waves, a regenerator a pulse tube with the inertance tube, and a reservoir, The dynamic pressures (the compressor, pulse tube, reservior) and the temperature at the cold heat exchanger are measured to explore the dependence of the inertance tube on the performance of the IPTR. The experimental results show the dependency of cool-down characteristics, no-load temperature and amplitude of the pressures on the length and diameter of the inertance tube.

신경외과에 입원한 경관급식 환자의 영양지원 실태와 영양상태에 관한 연구 (A Study on Nutritional Status and Clinical Practice of Neurosurgical Tube-fed Patients)

  • 박명희;안정옥
    • 대한지역사회영양학회지
    • /
    • 제3권3호
    • /
    • pp.430-439
    • /
    • 1998
  • This study was performed to investigate the nutritional status of neurosurgical tube-fed patients. The objective of this study was to improve the nutrition management of tube-fed patients. The current practices of tube feeding and enteral nutrition formula as for 95 patients in the hospital were examined by reviewing patients charts, and interviewing patients, nurses and their family members. The results are summarized as follows ; 57.9% of patients that received the formula showed a decrease in mental status. Among the subjects, 55.7% had nervous system diseases due to old age. Most of the tube-fed patients were hospitalized in the emergency room and while hospitalized, the status of their respiratory organ was abnormal. The method of tube-feeding was by Bolus injection and the type of the tube was a 16Fr size silicone tube. The amount of the injection per day while tube-feeding was on average 1424kcal for men and 1322kcal for women and the calories per day ranged from 1000-1500kcal(50.5%). The injection volume averaged 332.7ml and 45% of patients received more than 300ml per injection. The tube feeding intake rate was 127.9ml/min with 50% of subjects in the range of 50-100ml/min and 10% at 20ml/min. The longer the hospitalization, the older age, coma status, and the higher tube feeding rate, the more decreased were the biochemical parameters.

  • PDF