• Title/Summary/Keyword: trivalent chromium

Search Result 71, Processing Time 0.03 seconds

Characteristics of Cr(III)-based Conversion Coating Solution to Apply Aluminum Alloys for Improving Anti-corrosion Properties

  • Shim, Byeong Yun;Kim, Hanul;Han, Chang Nam;Jang, Young Bae;Yun, Jeong Woo
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.23 no.4
    • /
    • pp.79-85
    • /
    • 2016
  • It is imperative to find environment-friendly coatings as an alternative to the currently used hexavalent chromate conversion coatings for the purpose of improving the anti-corrosion properties of aluminum alloys. Hence, in this study, the corrosion properties of a trivalent chromate conversion coating solution are analyzed and measured. Because of the presence of multiple components in trivalent chromate conversion coating solutions, it is difficult to control plating, attributed to their mutual organic relationship. It is of significance to determine the concentrations of the components present in these coatings; hence, qualitative and quantitative analysis is required. The coating solution contained not only an environment-friendly component chromium(III), but also zirconium, fluorine, sulfur, and potassium, in the coating film. These metals are confirmed to produce a film with improved corrosion resistance to form a thin layer. The excellent corrosion resistance for the trivalent chromate solution is attributed to various inorganic and organic additives.

Electro-deposition and Crystallization Behaviors of Cr-C and Cr-C-P Alloy Deposits Prepared by Trivalent Chromium Sulfate Bath (황화물계 3가 크롬도금욕에서 크롬-탄소 및 크롬-탄소-인 합금도금의 전착과 결정화거동)

  • Kim, Man;Kim, Dae-Young;Park, Sang-Eon;Kwon, Sik-Chul;Choi, Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.2
    • /
    • pp.80-85
    • /
    • 2004
  • Chromium-carbon (Cr-C) and chromium-carbon-phosphorus (Cr-C-P) alloy deposits using trivalent chromium sulfate baths containing potassium formate were prepared to study their current efficiency, hardness change and phase transformations behavior with heat treatment, respectively. The current efficiencies of Cr-C and Cr-C-P alloy deposits increase with increasing current density in the range of 15-35 A/dm$^2$. Carbon content of Cr-C and phosphorous of Cr-C-P layers decreases with increasing current density, whereas, the carbon content of Cr-C-P layer is almost constant with the current density. Cr-C deposit shows crystallization at $400^{\circ}C$ and has (Cr+Cr$_{ 23}$$C_{6}$) phases at $800^{\circ}C$. Cr-C-P deposit shows crystallization at $600^{\circ}C$ and has (Cr+Cr$_{23}$ $C_{6}$$+Cr_3$P) phases at $800^{\circ}C$. The hardness of Cr-C and Cr-C-P deposits after heating treatment for one hour increase up to Hv 1640 and Hv 1540 and decrease about Hv 820 and Hv 1270 with increasing annealing temperature in the range of $400~^{\circ}C$, respectively. The hardness change with annealing is due to the order of occurring of chromium crystallization, precipitation hardening effect, softening and grain growth with temperature. Less decrease of hardness of Cr-C-P deposit after annealing above $700^{\circ}C$ is related to continuous precipitation of $Cr_{23}$ $C_{6}$ and $Cr_3$P phases which retard grain growth at the temperature.

Enlargement of Anti-corrosion of Zinc Plating by the Trivalent Chromium Sulfate Conversion Coating (3가 크롬황산염의 크로메이트에 의한 아연도금내식성 증대)

  • Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.18 no.3
    • /
    • pp.296-302
    • /
    • 2007
  • A trivalent chromate conversion coating solution which is composed with $KCr_2(SO_4)$ as main component was investigated to test a feasibility of use as an alternative six-valent chromate conversion coating for improvement of anti-corrosion of zinc plating. The proposed trivalent convesion coating was consisted of $KCr(SO_4)$ 35~45 g/L as trivalent chromium source, $NaH_2PO_4$ 20~30 g/L as phosphate, $CoSO_4$, 10~20 g/L, $ZnSO_4$ 10~20 g/L as metallic sulfates. This trivalent chromate films which are coated by this chromate conversion coating solution under pH 2.0~2.2, immersion time of 20~25 s at room temperature are able to achieve over 120 h in neutral salt spray test to 5% white rust.

Reduction of Hexavalent Chromium on PVC Filters (혜산산업보건학술상 수상논문 - PVC 여과지에 채취된 6가 크롬의 환원)

  • Sin, Yong-Cheol
    • 월간산업보건
    • /
    • s.356
    • /
    • pp.16-25
    • /
    • 2017
  • Chromium exists at various valences, including elemental, trivalent, and hexavalent chromium, and undergoes reduction-oxidation reactions in the environment. Since hexavalent chromium is known as a human carcinogen, it is most important to evaluate the oxidationreduction characteristics of the hexavalent chromium species. Although hexavalent chromium can be reduced to trivalent state, the detailed information on this in workplace environments is limited. The purpose of this study was to investigate hexavalent chromium reduction in time in various conditions. A pilot chrome plating operation was prepared and operated in a laboratory for this study. There was evidence that the hexavalent chromium was reduced by time after mist generation. The percentage ratio (with 95% confidence intervals in parentheses) of hexavalent chromium to total chromium was almost 100% (99.1 ; 102.3) immediately after mist generation, and was reduced to 87.4% (84.8 ; 89.9) at 1 hour and 81.0% (78.3 ; 83.5) at 2 hours, respectively. Another test indicated that hexavalent chromium collected on PVC filters was also reduced by time after sampling. Hexavalent chromium was reduced to 90.8% (88.2 ; 93.3) at 2 hours after sampling. It also was found that hexavalent chromium was reduced during storage in air. It is recommended that air samples of hexavalent chromium be protected against reduction during storage.

  • PDF