• Title/Summary/Keyword: triplet test

Search Result 24, Processing Time 0.028 seconds

A Comparison Between the Korean Digits-in-Noise Test and the Korean Speech Perception-in-Noise Test in Normal-Hearing and Hearing-Impaired Listeners

  • Kim, Subin;You, Sungwha;Sohn, Myoung Eun;Han, Woojae;Seo, Jae-Hyun;Oh, Yonghee
    • Journal of Audiology & Otology
    • /
    • v.25 no.4
    • /
    • pp.171-177
    • /
    • 2021
  • Background and Objectives: The purpose of the present study was to validate the performance and diagnostic efficacy of the Korean digits-in-noise (K-DIN) test in comparison to the Korean speech perception-in-noise (K-SPIN) test, which is the representative speech-in-noise test in clinical practice. Subjects and Methods: Twenty-seven subjects (15 normal-hearing and 12 hearing-impaired listeners) participated. The recorded Korean 0-9 digits were used to form quasirandom digit triplets; 50 target digit triplets were presented at the most comfortable level of each subject while presenting speech-shaped background noise at various levels of signal-to-noise ratios (-12.5, -10, -5, or +5 dB). Subjects were then instructed to listen to both target and noise masker unilaterally and bilaterally through a headphone. K-SPIN test was also conducted using the same procedure as the K-DIN. After calculating their percent correct responses, K-DIN and K-SPIN results were compared using a Pearson-correlation test. Results: Results showed a statistically significant correlation between K-DIN and K-SPIN in all hearing conditions (left: r=0.814, p<0.001; right: r=0.788, p<0.001; bilateral: r=0.727, p<0.001). Moreover, the K-DIN test achieved better testing efficacy, shorter average listening time (5 min vs. 30 min), and easier performance of task according to participants' qualitative reports than the K-SPIN test. Conclusions: In this study, the Korean version of digit triplet test was validated in both normal-hearing and hearing-impaired listeners. The findings suggest that the K-DIN test can be used as a simple and time-efficient hearing-in-noise test in audiology clinics in Korea.

A Comparison Between the Korean Digits-in-Noise Test and the Korean Speech Perception-in-Noise Test in Normal-Hearing and Hearing-Impaired Listeners

  • Kim, Subin;You, Sungwha;Sohn, Myoung Eun;Han, Woojae;Seo, Jae-Hyun;Oh, Yonghee
    • Korean Journal of Audiology
    • /
    • v.25 no.4
    • /
    • pp.171-177
    • /
    • 2021
  • Background and Objectives: The purpose of the present study was to validate the performance and diagnostic efficacy of the Korean digits-in-noise (K-DIN) test in comparison to the Korean speech perception-in-noise (K-SPIN) test, which is the representative speech-in-noise test in clinical practice. Subjects and Methods: Twenty-seven subjects (15 normal-hearing and 12 hearing-impaired listeners) participated. The recorded Korean 0-9 digits were used to form quasirandom digit triplets; 50 target digit triplets were presented at the most comfortable level of each subject while presenting speech-shaped background noise at various levels of signal-to-noise ratios (-12.5, -10, -5, or +5 dB). Subjects were then instructed to listen to both target and noise masker unilaterally and bilaterally through a headphone. K-SPIN test was also conducted using the same procedure as the K-DIN. After calculating their percent correct responses, K-DIN and K-SPIN results were compared using a Pearson-correlation test. Results: Results showed a statistically significant correlation between K-DIN and K-SPIN in all hearing conditions (left: r=0.814, p<0.001; right: r=0.788, p<0.001; bilateral: r=0.727, p<0.001). Moreover, the K-DIN test achieved better testing efficacy, shorter average listening time (5 min vs. 30 min), and easier performance of task according to participants' qualitative reports than the K-SPIN test. Conclusions: In this study, the Korean version of digit triplet test was validated in both normal-hearing and hearing-impaired listeners. The findings suggest that the K-DIN test can be used as a simple and time-efficient hearing-in-noise test in audiology clinics in Korea.

Combustion Test and Performance Analysis of Fuel Rich Gas Generator (농후 연소 가스발생기의 연소실험과 성능해석)

  • Kwon, Sun-Tak;Lee, Chang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.33 no.2
    • /
    • pp.92-97
    • /
    • 2005
  • A series of combustion test was done to verify the optimization result of a gas generator for a 10 ton thrust liquid rocket engine. An injector element is F-O-F impinging type injector and the test was conducted with kerosene/LOX propellants. Test results of combustion temperature and pressure show a very good agreement with optimal design result and verify that the design method was properly established. And turbulence ring revealed its effectiveness in enhancing combustion gas mixing and temperature difference in the radial direction showed only less than 15K. Also turbulence ring induced only 3.2% pressure loss in the combustion chamber, which is far less than conventional level observed in a gas turbine engine. Axial temperature distribution also shows that turbulence ring could effectively reduce about 10% or more in gas generator length if its location is properly selected.

Relations between 10 Primary Pulse Conditions Based on Doctors' Pulse Diagnoses (전문가 진단에 기반한 10대 맥상들 간의 연관성에 대한 연구)

  • Lee, Jae-Chul;Kang, Nam-Sik;Lee, Hae-Jung;Kim, Jong-Yeol;Kim, Jae-Uk
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.24 no.6
    • /
    • pp.1077-1081
    • /
    • 2010
  • In this work, we report the diagnostic relations among some primary pulse conditions such as the floating/sunken, deficient/forceful, large/fine, and the long/short pulses. For this purpose, we carried out a clinical test, in which 11 Oriental medical doctors had participated to diagnose the pulses for 1566 healthy subjects. The subjects were divided into 11 subgroups and each subgroup was allocated to an individual doctor. It resulted in that, for 847 subjects (54%), two or more than two pulse conditions were felt simultaneously, for which we counted the frequency of the pairs of the pulse conditions. For the statistical analysis, we used a Chi-square test. As a result, at high frequency, the forceful, large, and the long pulses were diagnosed in pairs or in their triplet, and a similar close relation was found between the deficient, fine, and the short pulses. The pairwise diagnoses of the pulse conditions between the forceful, large, and the long pulses, and between the deficient, fine, and the short pulses imply their close relatedness in clinics. This result is supported by the theory of deficiency/excess syndromes. Moreover, we show that the close relatedness among the pulse conditions can be understood in terms of the geometric features of the radial artery near the prominent bone. This is the first work which reports the relatedness between the primary pulses by an objective clinical test.

Construction of a Thermal Vacuum Chamber for Environment Test of Triple CubeSat Mission TRIO-CINEMA

  • Jeon, Jeheon;Lee, Seongwhan;Yoon, Seyoung;Seon, Jongho;Jin, Ho;Lee, Donghun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.335-344
    • /
    • 2013
  • TRiplet Ionospheric Observatory-CubeSat for Ion, Neutron, Electron & MAgnetic fields (TRIO-CINEMA) is a CubeSat with 3.14 kg in weight and 3-U ($10{\times}10{\times}30$ cm) in size, jointly developed by Kyung Hee University and UC Berkeley to measure magnetic fields of near Earth space and detect plasma particles. When a satellite is launched into orbit, it encounters ultra-high vacuum and extreme temperature. To verify the operation and survivability of the satellite in such an extreme space environment, experimental tests are conducted on the ground using thermal vacuum chamber. This paper describes the temperature control device and monitoring system suitable for CubeSat test environment using the thermal vacuum chamber of the School of Space Research, Kyung Hee University. To build the chamber, we use a general purpose thermal analysis program and NX 6.0 TMG program. We carry out thermal vacuum tests on the two flight models developed by Kyung Hee University based on the thermal model of the TRIO-CINEMA satellite. It is expected from this experiment that proper operation of the satellite in the space environment will be achieved.

TRIO-CINEMA의 환경시험 및 결과 분석

  • Geum, Gang-Hun;U, Ju;Lee, Seong-Hwan;Lee, Yong-Seok;Jeon, Je-Heon;Chae, Gyu-Seong;Jin, Ho;Seon, Jong-Ho;Lee, Dong-Hun;Thomas, Immel;Lin, Robert P.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.167.2-167.2
    • /
    • 2012
  • 경희대학교와 UC Berkeley, Imperial College London에서 공동으로 진행하는 TRIO-CINEMA Mission(TRiplet Ionosphere Observatory-Cubesat for Ion, Neutral, Electron and MAgnetic fields)은 총 3기의 초소형 위성으로 구성되어 있다. 3기의 위성은 고도 650~800km 상공의 태양동주기 궤도운동을 예상하고 있으며, 지구 근접공간의 입자 검출과 자기장 측정의 과학 임무를 맡게 된다. TRIO-CINEMA 비행 모델(Flight Model)의 환경시험은 진동시험과 열진공시험으로 진행되었다. 진동시험은 X, Y, Z 세 축에 대해 Sine 과 Random 모드로 진행되었다. TRIO-CINEMA가 탑재 될 러시아의 드네프르 로켓의 요구사항은 각 축에서 20Hz 이상의 고유진동수, Sine의 경우 최대 0.8G와 4oct/min Sweep Rate, Random의 경우 5.2Grms 와 35초의 지속시간에서의 안정성을 만족하는 것이다. 시험 결과 TRIO-CINEMA가 요구사항을 모두 만족시키는 것을 확인하였다. 또한, 열 주기 시험(Thermal Cycling Test)을 진행하여 우주공간에서 위성 시스템이 정상 동작하는지에 대한 신뢰성을 검증하였다. 열주기 시험은 미국 MIL표준 값을 참고하여 $10^{-6}Torr$에서 $-20{\sim}30^{\circ}C$의 온도를 주었으며, 시험을 진행하는 동안과 시험 후에 위성이 정상작동 함을 확인하였다. 이에 본 연구의 시험 방법과 그 결과를 기술하였다.

  • PDF

The Black Hole Mass - Stellar Velocity Dispersion Relation of Narrow-Line Seyfert 1 Galaxies

  • Yoon, Yosep;Woo, Jong-Hak
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.75.1-75.1
    • /
    • 2012
  • Narrow-Line Seyfert 1 galaxies are arguably the most important AGN subclass in investigating the origin of the black hole mass-galaxy stellar velocity dispersion (MBH-${\sigma}$) relation because of their high accretion rates close to the Eddington limit. Currently, it is still under discussion whether NLS1s are off from the local MBH-${\sigma}$ relation. We select a sample of 325 NLS1 at relatively low redshift (z<0.1) from the SDSS DR7 by constraining FWHM of $H{\beta}$ in the range of 800-2,200 km/s. Among them, we measured stellar velocity dispersion of 40 objects which show strong stellar absorption lines, e.g. Mg b triplet(${\sim}5175{\AA}$), Fe($5270{\AA}$). In contrast, the other 285 objects show too weak stellar absorption lines to measure velocity dispersion. Using the sample of 40 objects with stellar velocity dispersion measurements, we investigate whether NLS1s follow the same MBH-${\sigma}$ relation as normal galaxies and broad line AGNs. We also test the reliability of the width of narrow lines as a surrogate of stellar velocity dispersion by comparing directly measured stellar velocity dispersion with ${\sigma}$ inferred from [O III], [N II], [S II] line widths, respectively. We will discuss the connection between AGN activity in NLS1s and galaxy evolution based on these results.

  • PDF

A Study on Improving Facial Recognition Performance to Introduce a New Dog Registration Method (새로운 반려견 등록방식 도입을 위한 안면 인식 성능 개선 연구)

  • Lee, Dongsu;Park, Gooman
    • Journal of Broadcast Engineering
    • /
    • v.27 no.5
    • /
    • pp.794-807
    • /
    • 2022
  • Although registration of dogs is mandatory according to the revision of the Animal Protection Act, the registration rate is low due to the inconvenience of the current registration method. In this paper, a performance improvement study was conducted on the dog face recognition technology, which is being reviewed as a new registration method. Through deep learning learning, an embedding vector for facial recognition of a dog was created and a method for identifying each dog individual was experimented. We built a dog image dataset for deep learning learning and experimented with InceptionNet and ResNet-50 as backbone networks. It was learned by the triplet loss method, and the experiments were divided into face verification and face recognition. In the ResNet-50-based model, it was possible to obtain the best facial verification performance of 93.46%, and in the face recognition test, the highest performance of 91.44% was obtained in rank-5, respectively. The experimental methods and results presented in this paper can be used in various fields, such as checking whether a dog is registered or not, and checking an object at a dog access facility.

Experimental study of combustion stability assessment of injector (분사기의 연소 안정성 평가를 위한 실험적 방법 연구)

  • Seo, Seong-Hyeon;Lee, Kwang-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.4
    • /
    • pp.61-66
    • /
    • 2004
  • The objective of the present study is to develop methodology for the assessment of combustion stability of liquid rocket injectors. To simulate actual combustion occurring inside of a thrust chamber, a fullscale injector has been employed in the study, which bums gaseous oxygen and mixture of methane and propane. The main idea of the experiment is that the mixing mechanism is considered as a dominant factor significantly affecting combustion instability in a fullscale thrust chamber. A single split triplet injector has been used with an open-end cylindrical combustion chamber. The characteristics revealed by excited dynamic pressures in gaseous combustion show degrees of relative acoustic damping depending on operating conditions. Upon test results, the direct comparison between various types of injectors can be realized for the selection of the best design among prospective injectors.

Development of CINEMA Mission Uplink Communication System

  • Yoon, Na-Young;Yoon, Se-Young;Kim, Yong-Ho;Yoon, Ji-Won;Jin, Ho;Seon, Jong-Ho;Chae, Kyu-Sung;Lee, Dong-Hun;Lin, Robert P.
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.1
    • /
    • pp.33-40
    • /
    • 2012
  • Triplet Ionospheric Observatory (TRIO) CubeSatforIon, Neutral, Electron MAgneticfields (CINEMA) is a CubeSat with the weight 3 kg that will be operated in the orbit conditions of about 800 km altitude and $90^{\circ}$ inclination angle, using the S-band and ultra-high frequency (UHF)-band communication frequencies. Regarding the communication antenna loaded on the satellite, the two patch antennas has the downlink function in the S-band, whereas the two whip antennas has the function to receive the command sent by the ground station to the satellite in the UHF-band. The uplink ground station that communicates through the UHF-band with the CINEMA satellite was established at Kyung Hee University. The system is mainly composed of a terminal node controller, a transceiver, and a helical antenna. The gain of the helical antenna established at the Kyung Hee University ground station was 9.8 dBi. The output of the transceiver was set to be 5 W (6.9 dB) for the communication test. Through the far-field test of the established system, it was verified that the Roman characters, figures and symbols were converted into packets and transmitted to the satellite receiver in the communication speed of 9,600 bps.