• Title/Summary/Keyword: trichloromethane

Search Result 9, Processing Time 0.028 seconds

Volatile Organic Compounds contamination in some urban runoff and groundwater samples in Seoul City (서울시 도로변 빗물과 지하수의 VOCs오염)

  • 이평구;박성원;전치완;신성천
    • Journal of Soil and Groundwater Environment
    • /
    • v.6 no.3
    • /
    • pp.73-91
    • /
    • 2001
  • compounds (VOCs) were selected for assessment of VOCs contamination in some urban runoff and groundwater samples in Seoul. They included 3 aromatic hydrocarbons, 13 alkyl benzenes, 1 ether, 26 halogenated alkanes, 10 halogenated alkenes, and 9 halogenated aromatics. The levels of VOCs in urban runoff and groundwater were measured for samples collected in March 2000, June 2000 and November 2000 in Seoul City. A total of 78 samples (44 run-off water, 27 groundwater, and 7 samples from 4 urban wastewater treatment plants in Seoul) were collected and analysed by GC-MS with purge and trap. After examination of the runoff, it was concluded that alkyl benzenes and aromatic hydrocarbons were organic compounds which were significantly impacted by traffic flows in Seoul. Of 62 VOCs, only 11 VOCs were not detected in runoff samples, while 14 VOCs were detected in 27 groundwater samples. The toluene content in the runoff was extremely variable from 0.1ppb to 29,310ppb, depending on the different sampling sites. The concentrations of xylene ranged between 0.07ppb and 2970ppb in the runoff. The concentrations ranged from 0.05ppb to 33.0ppb for benzene, 0.05ppb to 960ppb for ethylbenzene, 0.08ppb to 20ppb for trichloromethane (chloroform) , 0.03ppb to 4.30ppb for trichloroethylene(TCE) and 0.1ppb to 50ppb for 1,1,2-trichloroethane. From the preliminary study of groundwater from some wells in Seoul, the most frequently detected VOCs are djchlorornethane(methylene chloride), trichloromethane(chloroform) and toluene. Most of aromatic hydrocarbons, alkyl benzenes and other solvents generally lower than detection limits.

  • PDF

Characteristics of Exposure to High-Risk Substances in the Electronics Industry Using the Work Environment Survey and Work Environment Measurement Database (2018~2022) in South Korea -Dichloromethane, Trichloromethane, and Tetramethylammonium Hydroxide- (작업환경실태조사 및 작업환경측정자료(2018~2022) 결과를 활용한 우리나라 전자산업에서의 고위험물질 노출 특성 -디클로로메탄, 트리클로로메탄, 수산화테트라메틸암모늄 중심으로-)

  • Sung Ho Hwang;Seunhon Ham;Hyoung-Ryoul Kim;Hyunchul Ryu;Jinsoo An;JinHa Yoon;Chungsik Yoon;Naeun Lee;Sangman Lee;Jaehwan Lee;Se Young Kwon;Jaepil Chang;Kwonchul Ha
    • Journal of Environmental Health Sciences
    • /
    • v.50 no.3
    • /
    • pp.221-228
    • /
    • 2024
  • Background: Social interest is increasing due to frequent accidents caused by chemicals in the electronics industry. Objectives: The purpose of this study is to present a management plan by evaluating the exposure characteristics of dichloromethane (DCM), trichloromethane (TCM), and tetramethyl ammonium hydroxide (TMAH), which are high-risk substances to which people may be exposed in the electronics industry in South Korea. Methods: To investigate the handling companies and status of the hazardous chemicals DCM, TCM, and TMAH, the handling status of the three substances was classified based on electronics industry-related codes from the 2019 Work Environment Survey (Chemical Handling and Manufacturing) data with work environment measurement results for five years. Results: DCM, TCM, and TMAH are commonly used as cleaning agents in the electronics industry. For DCM, it was found that all work environment measurement results from 2018 to 2021 but not 2022 exceeded the exposure standard. Conclusions: Identifying the distribution channels of hazardous chemicals is an intervention point that can reduce exposure to hazardous chemicals. It requires management through tracking systems such as unique verification numbers at the import and manufacturing stages, and proper cultivation of and related support for handling chemicals by business managers.

Separation of Trichlorinated Hydrocarbons by ZSM-5 Zeolite Membrane (ZSM-5 제올라이트 분리막에 의한 3가 염소화합물의 투과증발 분리)

  • Lee Yong-Taek;Sim Eun-Young;Ahn Hyo-Seong
    • Membrane Journal
    • /
    • v.16 no.2
    • /
    • pp.159-166
    • /
    • 2006
  • MFI(Mobil Five) structured hydrophobic ZSM-5 zeolite membrane was used for selective pervaporation of trichlorinated organic compounds(trichloromethane, trichloroethane, trichloroethylene) from their aqueous solutions. ZSM-5 zeolite membrane was hydrothermally synthesized on the inside of a porous stainless steel tube by secondary growth employing ZSM-5 seed powders. Separation factors for each binary mixtures were observed $16{\sim}66$ for trichloromethane/water, $3.3{\sim}4.6$ for trichloroethane/water and $1.4{\sim}8$ for trichloroethylene/water at the experimental conditions of the feed mole fraction from 0.0001 to 0.001 with temperature ranged $25{\sim}35^{\circ}C$.

Oxidation Efficiency of Organic Compounds in Water Using $TiO_2$ Photocatalytic Membranes ($TiO_2$광촉매 막을 이용한 수용액상 유기물의 산화효율)

  • 현상훈;심세진;정연규
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1993.10a
    • /
    • pp.39-39
    • /
    • 1993
  • 반도성 세라믹 광촉매 막 반응기 (membrane reactor)에 의한 난분해성 유독 유기물질의 분해공정을 개발하기 위한 기초연구로서 $TiO_2$ 막 반응기의 formic acid 및 trichloromethane에 대한 광분해 효율이 연구되었다. 막 반응기는 용액의 정밀여과 (microfiltration)는 물론 유기물의 광분해를 동시에 수행할 수 있도록 다공성 $TiO_2$ 튜브 (평균기공 : $0.2 \mu m$)를 이용한 새로운 타입으로 ㅐㄱ발되었으며 광원으로는 365 nm 파장을 갖는 UV를 사용하였다. 또한 반응기의 광분해 효율을 증진시키기 위하여 슬립케스팅법으로 제조한 $TiO_2$ 튜브표면을 $TiO_2$ 졸로 코팅하였다.

  • PDF

Organic Solvent Dyeing (IV) - The Effect of Water on Dyeing of Polyester Fiber in Alkanes - (유기용매염색(IV) - 알칸류를 염색매체로 한 폴리에스테르 섬유의 염색에 있어서 물의 영향 -)

  • 김태경;임용진;조광호;조규민;박태수
    • Textile Coloration and Finishing
    • /
    • v.12 no.5
    • /
    • pp.308-314
    • /
    • 2000
  • The dyeability of C. I. Disperse Violet 1 on polyester fiber in alkance including a small amount of water was investigated. Up to 1% of water in alkanes the dye uptakes were increased rapidly. The dyeing transition temperature of the polyester fiber in alkanes with 1% of water was $86.5^\circ{C}$ that is lower by $11^\circ{C}$ than $97.5^\circ{C}$ in alkanes only. This means that water plasticizes the polyester fiber, and that dyes begin to penetrate the polyester fiber at lower temperature. Addition of trichloromethane which is known as a strong plasticizer on polyester fiber, in alkanes, increased the dye uptakes of C. I. Disperse Violet 1 on polyester fiber at $100^\circ{C}$, but the dyeing transition temperature was lower by $3^\circ{C}$ than in alkanes only.

  • PDF

Characteristics of Disinfection By-Products Formation in Chlorination of Principal Raw Waters for Drinking Water of Jeju Island, Korea

  • Oh, Sun-Mi;Park, Tae-Hyun;Lee, Min-Gyu;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1031-1041
    • /
    • 2012
  • This study was carried out to investigate the characteristics of disinfection by-products (DBPs-trihalomethanes (THMs), haloacetic acids (HAAs) and haloacetonitriles (HANs) formation in chlorination of principal raw waters used for drinking water on Jeju Island, Korea. The domestic water supply of other area and humic acid solution (HA) were used as a reference point. The effects of chlorine contact time, solution temperature and pH on DBPs formation potential (DBPFP) were investigated for raw waters. In addition, the effect of $Br^-$ was studied for HA. The DBPFP (THMFP, HAAFP and HANFP) were increased with increasing chlorine contact time. Comparing the individual DBPFPs for raw waters, they decreased in the order of HAAFP > THMFP ${\geq}$ HANFP. As the solution temperature was increased, the THMFP, HAAFP and HANFP increased. With increasing the solution pH, the THMFP was increased, but HAAFP and HANFP were decreased. With the addition of 0.3 mg/L $Br^-$ for HA, the DBPFP was increased and the major chemical species changed: from trichloromethane to dibromochloromethane and tribromomethane for THMs; from dichloroacetic acid and trichloroacetic acid to tribromoacetic acid for HAAs; and from dichloroacetonitrile to dibromoacetonitrile for HANs.

토양 및 지하수 Investigation 과 Remediation에 대한 현장적용

  • Wallner, Heinz
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.11a
    • /
    • pp.44-63
    • /
    • 2000
  • Situated close to Heathrow Airport, and adjacent to the M4 and M25 Motorways, the site at Axis Park is considered a prime location for business in the UK. In consequnce two of the UK's major property development companies, MEPC and Redrew Homes sought the expertise of Intergeo to remediate the contaminated former industrial site prior to its development. Industrial use of the twenty-six hectare site, started in 1936, when Hawker Aircraft commence aircraft manufacture. In 1963 the Firestone Tyre and Rubber Company purchased part of the site. Ford commenced vehicle production at the site in the mid-1970's and production was continued by Iveco Ford from 1986 to the plant's decommissioning in 1997. Geologically the site is underlain by sand and gravel, deposited in prehistory by the River Thames, with London Clay at around 6m depth. The level of groundwater fluctuates seasonally at around 2.5m depth, moving slowly southwest towards local streams and watercourses. A phased investigation of the site was undertaken, which culminated in the extensive site investigation undertaken by Intergeo in 1998. In total 50 boreholes, 90 probeholes and 60 trial pits were used to investigate the site and around 4000 solid and 1300 liquid samples were tested in the laboratory for chemical substances. The investigations identified total petroleum hydrocarbons in the soil up to 25, 000mg/kg. Diesel oil, with some lubricating oil were the main components. Volatile organic compounds were identified in the groundwater in excess of 10mg/l. Specific substances included trichloromethane, trichloromethane and tetrachloroethene. Both the oil and volatile compounds were widely spread across the site, The specific substances identified could be traced back to industrial processes used at one or other dates in the sites history Slightly elevated levels of toxic metals and polycyclic aromatic hydrocarbons were also identified locally. Prior to remediation of the site and throughout its progress, extensive liaison with the regulatory authorities and the client's professional representatives was required. In addition to meetings, numerous technical documents detailing methods and health and safety issues were required in order to comply with UK environmental and safety legislation. After initially considering a range of options to undertake remediation, the following three main techniques were selected: ex-situ bioremediation of hydrocarbon contaminated soils, skimming of free floating hydrocarbon product from the water surface at wells and excavations and air stripping of volatile organic compounds from groundwater recovered from wells. The achievements were as follows: 1) 350, 000m3 of soil was excavated and 112, 000m3 of sand and gravel was processed to remove gravel and cobble sized particles; 2) 53, 000m3 of hydrocarbon contaminated soil was bioremediated in windrows ; 3) 7000m3 of groundwater was processed by skimming to remove free floating Product; 4) 196, 000m3 of groundwater was Processed by air stripping to remove volatile organic compounds. Only 1000m3 of soil left the site for disposal in licensed waste facilities Given the costs of disposal in the UK, the selected methods represented a considerable cost saving to the Clients. All other soil was engineered back into the ground to a precise geotechnical specification. The following objective levels were achieved across the site 1) By a Risk Based Corrective Action (RBCA) methodology it was demonstrated that soil with less that 1000mg/kg total petroleum hydrocarbons did not pose a hazard to health or water resources and therefore, could remain insitu; 2) Soils destined for the residential areas of the site were remediated to 250mg/kg total petroleum hydrocarbons; in the industrial areas 500mg/kg was proven acceptable. 3) Hydrocarbons in groundwater were remediated to below the Dutch Intervegtion Level of 0.6mg/1; 4) Volatile organic compounds/BTEX group substances were reduced to below the Dutch Intervention Levels; 5) Polycyclic aromatic hydrocarbons and metals were below Inter-departmental Committee for the Redevelopment of Contaminated Land guideline levels for intended enduse. In order to verify the qualify of the work 1500 chemical test results were submitted for the purpose of validation. Quality assurance checks were undertaken by independent consultants and at an independent laboratory selected by Intergeo. Long term monitoring of water quality was undertaken for a period of one year after remediation work had been completed. Both the regulatory authorities and Clients representatives endorsed the quality of remediation now completed at the site. Subsequent to completion of the remediation work Redrew Homes constructed a prestige housing development. The properties at "Belvedere Place" retailed at premium prices. On the MEPC site the Post Office, amongst others, has located a major sorting office for the London area. Exceptionally high standards of remediation, control and documentation were a requirement for the work undertaken here.aken here.

  • PDF

UV Photodegradation of Chlorinated VOCs: Removal Efficiency and Products (염소계 VOCs의 UV 광분해 연구: 제거율 및 부산물)

  • Kang, InSun;Xi, Jinying;Wang, Can;Hu, Hong-Ying
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.2
    • /
    • pp.87-96
    • /
    • 2017
  • In this study, 4 gases containing typical chlorinated volatile organic compounds (VOCs) were treated by ultraviolet (UV) irradiation. The typical chlorinated VOCs are dichloromethane (DCM), trichloromethane (TCM), carbon tetrachloride (CTC) and trichloroethylene (TCE). The removal efficiency (RE) and the products of chlorinated VOCs by UV irradiation are investigated. At this time, 2 types of background gas (air and nitrogen) were used to figure out the RE by photooxidation and photolysis. The specification of UV-lamp used in this study was low-pressure mercury lamp emitting wavelength of 185~254 nm. The experimental conditions were set as initial VOC concentration of $180{\pm}10ppm$, empty bed retention time (EBRT) of 53 s, temperature of $23{\pm}2^{\circ}C$ and relative humidity of $65{\pm}5%$. In the photolysis condition with nitrogen ($N_2$) as background gas, the averaged RE of the 4 types of chlorinated VOCs was about 24% higher than that with photooxidation; and the REs of VOCs except CTC were confirmed as >99%. The composition of off-gases after UV photooxidation in air was investigated and several intermediates from DCM, TCM and TCE were detected by GC/MS. Among them, phosgene which is a toxics was detected as an intermediate of TCM. In addition, the concentration of carbon dioxide ($CO_2$) in the off-gases was measured to calculate the mineralization rate (MR). With the photooxidation, TCE showed the highest RE (>99%) while MR was the lowest (17%); and the MR of DCM was the highest (86%). In addition, particulate matters (PM) in the off-gases was also detected and high concentrated $PM_{10}$ ($21,580{\mu}g{\cdot}m^{-3}$) and $PM_{2.5}$ ($6,346{\mu}g{\cdot}m^{-3}$) were detected in TCE off-gas. More than 99% of the chlorinated VOCs could be removed using UV254-185 nm lamp, while it is necessary to conduct further studies on the production and treatment of secondary pollutants.

Review of Problems with Use of Halogenated Cleaning Solvents Revealed through Case Studies of Cleaning Solvent Poisoning and Analysis of Domestic and Overseas Regulations (세척제 용매 중독 사례와 국내·외 규제 검토를 통한 할로겐화 용매 세척제 사용의 문제점 고찰)

  • Naroo Lee;Hye Jin Lee;Sujin Jeong;Dohee Lee;Arom Shin
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.4
    • /
    • pp.517-527
    • /
    • 2023
  • Objectives: We examine cases of chemical poisoning that occurred in the cleaning of metal parts and the regulations on halogenated solvents in other countries and propose regulations necessary to prevent chemical poisoning from halogenated solvents. Methods: We collected cases of chemical poisoning through the website of the Korea Occupational Safety and Health Agency. A review of the literature was conducted focusing on regulations related to halogenated solvents in the United States and the European Union, particularly for cleaning metal parts. Among the Material Safety Data Sheets submitted to the government, MSDS containing eleven substances were extracted to confirm the composition and product use. We investigated cleaning methods for metal parts used in South Korea. For the hazard classification, the European Chemicals Agency or Japan's NITE's website was used. Results: In the case of poisoning, the cleaning methods involving trichloromethane were dipping and dry, which was not found in the literature. It was confirmed that many halogenated solvents and dimethyl carbonate were used for metal cleaning in South Korea. In vapor degreasing using TCE in the USA, even if the facility is strictly managed, such as by installing cooling coils in open cleaning facilities, the risk of exposure to TCE is considered to be not only carcinogenic but also a concern for acute and chronic effects. In comparison, exposure through Korean work methods such as dipping and drying operations is inevitably much higher. Conclusions: The transition to water-based cleaning with low-hazard chemicals should be a priority in the cleaning process. In the case of metal parts that require precise cleaning, if the use of a halogenated solvent is inevitable, a closed degreasing facility should be used to minimize exposure. The current regulations in the Occupational Safety and Health Act, the Chemical Substances Control Act, and the Air Environment Conservation Act do not require cleaning facilities to minimize emissions. To protect the health of workers using halogenated solvents to clean metal parts, regulations that require a fundamental reduction in exposure will be necessary.