• Title/Summary/Keyword: treatment time

Search Result 15,942, Processing Time 0.042 seconds

A STUDY ON SURFACE HARDNESS OF COMPOSITE RESINS ACCORDING TO STORAGE CONDITON AND HEAT TREATMENT (보관조건과 열처리에 따른 복합레진의 표면경도에 관한 연구)

  • Kang, Seung-Hoon;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.194-204
    • /
    • 1994
  • The purpose of this study was to evaluate the surface hardness of composite resins according to heat treatment. storage condition and storage time. In this study. two kinds of composite resin inlays and one kind of conventional posterior composite resin were used as experimental materials. One hundred eighty composite resin specimens were constructed from composite resin inlays and conventional posterior composite resin. The conditions of this study were heat treatment. storage condition and storage time. Hardness readings were taken from the top surface of each samples using the Vickers microhardness tester(MHT-l. Matsuzawa. Japan}. The following results from this study were obtained: 1. Regardless of storage condition. both composite resin inlay and conventional posterior composite resin have a higher surface hardness under heat treatment than not. 2. Composite resins with heat treatment have a higher surface hardness under dry storage than under water immersion. 3. In case of Clearfil Photo Posterior and Brilliant Enamel with heat treatment. there was no significant difference with time. but Clearfil CR Inlay with heat treatment. there was statistical difference after 24 hours. 4. Surface hardness of composite resins with coarse hybrid type was higher than that of composite resin with fine hybrid type.

  • PDF

EFFECTS OF ACID TREATMENT OF FLUORIDE APPLIED DENTIN SURFACE ON DENTIN BONDING (불소도포한 상아질면의 산처리가 상아질접착에 미치는 영향)

  • Hwang, Hea-Kyung;Ahn, Sik-Hwan;Kim, Sung-Kyo;Jo, Kwang-Hun;Park, Jin-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.602-618
    • /
    • 1996
  • The purpose of this study was to investigate the effect of acid treatment of fluoride applied dentin surface with various concentrations of phosphoric acid for various periods of time on dentin bonding. Dentin specimens prepared from freshly extracted bovine mandibular anterior teeth were divided into fluoridated and nonfluoridated groups. Specimens of nonfluoridated group were pretreated with 10% phosphoric acid for 15 seconds. Those of fluoridated groups were treated with 2% sodium fluoride or 2% stannous fluoride solution for 5 minutes and stored in $37^{\circ}C$ distilled water for 3 days, followed by phosphoric acid treatment. The concentrations of phosphoric acid were 10%, 32% or 50% and the treatment periods of time were 15, 30 or 60 seconds. All the specimens were bonded with All Bond$^{(R)}$ 2 and Bisfil$^{TM}$ composite resin. After bonded specimens were stored in $37^{\circ}C$ distilled water for 24 hours, tensile bond strengths of each specimens were measured and the pretreated dentin and the fractured dentin surfaces were examined under the scanning electron microscope. The results were as follows : The tensile bond strengths from the fluoridated groups were significantly lower than those from the nonfluoridated group when the concentrations of phosphoric acid and the treatment periods of time were equal in all the groups (p<0.05). In general, the higher the concentration of phosphoric acid and the longer the treatment period of time for acid etching on the fluoride applied dentin surface, the higher were the bond strength values. Recovery of bond strength of the dentin bonding agent was better in the NaF applied group than in the $SnF_2$ applied one. SEM findings of NaF applied and $SnF_2$ applied dentin surfaces demonstrated reaction product-covered and partially or completely obstructed dentinal tubules. SEM findings of dentin surfaces fluoridated for 5 minutes followed by etching showed wider tubular openings and more clean dentin surfaces when dentin was etched with higher concentration of phosphoric acid for longer period of time. On the SEM observations of the fractured dentin-resin interface, the etched specimens of fluoridated group showed an adhesive failure mode when the concentration of phosphoric acid and the treatment period of time were same as in the nonfluoridated group. As the concentration of phosphoric acid and the treatment period of time increase during acid etching, the cohesive failure area increased. However, excessive acid etching caused adhesive failure.

  • PDF

A Study on Compliance of Hypertensive Workers at a Department Store in Seoul (서울 시내 한 백화점 근로자의 고혈압 치료 순응도에 관한 연구)

  • Jee, Ju-Ok
    • Korean Journal of Occupational Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.19-30
    • /
    • 2003
  • Increasing occupational cerebrovascular & cardiovascular disease, it becomes the most serious problem in the occupational health management. Hypertension is the most important risk factor of cerebrovascular & cardiovascular disease. Although treatment for hypertension has the priority, hypertension has not been managed systematically at the worksite. The objectives of this study were to investigate the actual situation of its treatment, figure out what factors can affect compliance for hypertension treatment and analyze the relations between compliance and employment status. Subjects were 28 workers who have been diagnosed as hypertension at periodic health examination, 20 workers who have been managed for hypertension at dispensary and 22 workers who were diagnosed during the study periods. The results of the study were as follows; 1. More women have been hired as part time workers and had lower education background and income than the full time workers. 2. Among the factors that have been known to affect the treatment compliance, part time workers had less supports from the company than full time workers. 3. We got the comparison of difference between compliance and variables that the factor grade of cure promotion and average ages are high in high compliance. In conclusion there were not the difference of compliance by employment status. But it was hard to rule out the selection vias because the sample size was so small. So it seems difficult to generalized the conclusion that employment status doesn't affect the treatment compliance.

  • PDF

Effects of Maturing Period and Moisture Content of Swine Manure on Composting Potentials (돈분의 수분조절 및 부숙기간이 퇴비화에 미치는 영향)

  • 김원호;정광화;서성;백광수;신동은;유성오;김원영
    • Journal of Animal Environmental Science
    • /
    • v.4 no.1
    • /
    • pp.47-53
    • /
    • 1998
  • The purpose of this study was to investigate the change of temperature, moisture content, weight and chemical properties in swine manure during the maturing process and moisture content of swine manure. The manure production on the early time(1 days), middle(25 days: and late(50 days) were made by moisture 45%, 55%, 65%, 75% in swine manure, according to manure treatment of the early time, the highest temperature of swine manure treatment was 59$^{\circ}C$ as moisture 75% after mixed 24 hours, the lowest 45% in mixed 25 days(middle time), 32$^{\circ}C$ as moisture 45% in mixed 50 days(late time). 2. Weight change during maturing manure, the most treatment of weight decrease was 17.4% as moisture 45%, the least of those was 12.2% as moisture 75% during maturing process of swine manure. 3. Volume change during maturing manure, the most treatment of volume decrease was 37.1% as moisture 65%, the least of those was 32.1% as moisture 55% during maturing swine manure, but not big difference between treatment. 4. T-N, P2O5, K2O content of compost were increased during maturing process, On the contrary, T-C content and C/N ratio were reduced.

Effect of Reversed Austenite on the Damping Capacity of Austenitic Stainless Steel (오스테나이트계 스테인리스강의 감쇠능에 미치는 역변태 오스테나이트의 영향)

  • Kim, Young-Hwa;Sung, Ji-Hyun;Kang, Chang-Yong
    • Journal of Power System Engineering
    • /
    • v.19 no.1
    • /
    • pp.70-75
    • /
    • 2015
  • The influence of reversed austenite on the damping capacity in austenitic stainless steel with two phase of martensite and reversed austenite was investigated. The two phases of deformation induced martensite and reversed austenite was obtained by an reverse annealing treatment at $500^{\circ}C{\sim}700^{\circ}C$ for various time after 70% cold rolling. With an increase of the reverse annealing treatment temperature and time, volume fraction of reversed austenite was rapidly increased. With an increase of volume fraction of reveresd austenite, damping capacity was rapidly increased. At same volume of reveresd austenite, damping capacity of reversed austenite obtained by reverse annealing treatment at $700^{\circ}C$ for various time was higher then reveresd austenite obtained by reverse annealing treatment at $500^{\circ}C{\sim}700^{\circ}C$ for 10min. Thus, the damping capacity was affected greatly by reversed austenite obtained by annealing treatment at $700^{\circ}C$ for various time.

Study on the Ag Thin Film Layer Deposition of the YBCO Coated Conductor Using a Plasma Surface Treatment (플라즈마 표면처리를 이용한 YBCO Coated Conductor의 Ag 박막층 증착에 관한 연구)

  • Jeong, Hyun-Gi;Yang, Sung-Chae;Choi, Byoung-Jung;Du, Ho-Ik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.1
    • /
    • pp.32-36
    • /
    • 2017
  • The Ag thin film of YBCO (yttrium barium copper oxide) CC (coated conductor) protect the YBCO layer and, at the same time, affects the electrical characteristics of the YBCO CC. Therefore, YBCO CC with the commercialization of the Ag thin film layers makes it easy to establish a process, it can lead to a variety of characteristic changes in YBCO CC. In this paper, plasma surface treatment was carried out to facilitate the deposition of the Ag thin film and the deposition process of YBCO CC. Surface roughness from the test results was increased as the time of the plasma surface treatment increased from 5 to 20 minutes. On the other hand, the surface roughness was decreased for the time of the plasma surface treatment over 20 minutes. Furthermore, after depositing, the increasing of deposit amount and reduced lifting phenomenon showed a similar tendency with the rise time of surface roughness.

Bioremediation of Phenolic Compounds Having Endocrine-disrupting Activity Using Ozone Oxidation and Activated Sludge Treatment

  • Nakamura, Yoshitoshi;Daidai, Masakazu;Kobayashi, Fumihisa
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.3
    • /
    • pp.151-155
    • /
    • 2004
  • The bioremediation of water system contaminated with phenolic compounds having endocrine-disrupting activity, i.e. 2,4-dichlorophenol, 2,4-dichlorophenoxy acetic acid (2,4-D), and 2,4,5-trichlorophenoxy acetic acid (2,4,5-T), was investigated by using ozone oxidation and activated sludge treatment. Ozone oxidation (ozonation time: 30 min) followed by activated sludge treatment (incubation time: 5 days) was an efficient treatment method for the conversion of phenolic compounds in water into carbon dioxide and decreased the value of total organic carbon (TOC) up to about 10% of initial value. Furthermore, 2,4-D was dissolved in water containing salt, i.e. artificial seawater (ASW), and this water was used as model coastal water contaminated with phenolic compounds. The activated sludge treatment (incubation time: 5 days) could consume significantly organic acids produced from 2,4-D in the model costal water by the ozone oxidation (ozonation time: 30min) and decrease the value of TOC up to about 35% of initial value.

Characteristics of Surface Hardening by Laser Power Control in Real Time of Spheroidal Graphite Cast Iron (실시간 출력 제어를 통한 구상흑연 주철의 레이저 표면경화 특성)

  • Kim, Jongdo;Song, Mookeun
    • Laser Solutions
    • /
    • v.18 no.2
    • /
    • pp.1-4
    • /
    • 2015
  • This study is related to the surface hardening treatment to spheroidal graphite cast iron for die by using high power diode laser. Laser device used in this experiment is capable of real-time laser power control. This is because the infrared temperature sensor (two color pyrometer) attached to the optical system measures the surface temperature of specimen and adjusts the laser power in real time. The surface treatment was carried out with the change of heat treatment temperature at the beam travel speed 3 mm/sec. Hardened width and depth was measured and hardened zone was analyzed by micro vickers hardness test in order to research the optimum condition of heat treatment. The changes in microstructure of the hardened zone also was examined. As a result of hardness measurement and observations on microstructure of hardened zone, hardness increased over three times as compared with base metal because the martensite was formed on the matrix structure.

Frequency and time of actual duties of some dental hygienists (일부지역 치과위생사의 실제 업무의 빈도와 소요시간)

  • Hwang, Soo-Jeong;Han, Yang-Keum
    • Journal of Korean Academy of Dental Administration
    • /
    • v.7 no.1
    • /
    • pp.10-20
    • /
    • 2019
  • Korean dental hygienists perform more tasks in dental clinics than are described in the law. The purpose of this study was to investigate the actual work of Korean dental hygienists in dental clinics using an observational study design. Two dental hygienists observed and recorded the work performed in 1 day from the time of commencement to the time of leaving work by 18 dental hygienists working in the dental clinic in a single area. Data management, prevention of infection, counseling, calculus removal, radiography, assistance of fixed orthodontic treatment, assistance of fixed prosthetic treatment, and preparation for implant surgery were recorded. Among the tasks that take more than 1 min, the most time-consuming tasks were document management, infection control, consultation, calculus removal, preparation for implant surgery, assistance of orthodontic treatment, and assistance of fixed prosthetic treatment. Korean dental hygienists are performing various tasks, such as infection control, dental hospital/clinic management, oral disease prevention, and dental treatment assistants.