• Title/Summary/Keyword: treatment plan

Search Result 1,562, Processing Time 0.032 seconds

Evaluation of the Usefulness of MapPHAN for the Verification of Volumetric Modulated Arc Therapy Planning (용적세기조절회전치료 치료계획 확인에 사용되는 MapPHAN의 유용성 평가)

  • Woo, Heon;Park, Jang Pil;Min, Jae Soon;Lee, Jae Hee;Yoo, Suk Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.115-121
    • /
    • 2013
  • Purpose: Latest linear accelerator and the introduction of new measurement equipment to the agency that the introduction of this equipment in the future, by analyzing the process of confirming the usefulness of the preparation process for applying it in the clinical causes some problems, should be helpful. Materials and Methods: All measurements TrueBEAM STX (Varian, USA) was used, and a file specific to each energy, irradiation conditions, the dose distribution was calculated using a computerized treatment planning equipment (Eclipse ver 10.0.39, Varian, USA). Measuring performance and cause errors in MapCHECK 2 were analyzed and measured against. In order to verify the performance of the MapCHECK 2, 6X, 6X-FFF, 10X, 10X-FFF, 15X field size $10{\times}10$ cm, gantry $0^{\circ}$, $180^{\circ}$ direction was measured by the energy. IGRT couch of the CT values affect the measurements in order to confirm, CT number values : -800 (Carbon) & -950 (COUCH in the air), -100 & 6X-950 in the state for FFF, 15X of the energy field sizes $10{\times}10$, gantry $180^{\circ}$, $135^{\circ}$, $275^{\circ}$ directionwas measured at, MapPHAN allocated to confirm the value of HU were compared, using the treatment planning computer for, Measurement error problem by the sharp edges MapPHAN Learn gantry direction MapPHAN of dependence was measured in three ways. GANTRY $90^{\circ}$, $270^{\circ}$ in the direction of the vertically erected settings 6X-FFF, 15X respectively, and Setting the state established as a horizontal field sizes $10{\times}10$, $90^{\circ}$, $45^{\circ}$, $315^{\circ}$, $270^{\circ}$ of in the direction of the energy-6X-FFF, 15X, respectively, were measured. Without intensity modulated beam of the third open arc were investigated. Results: Of basic performance MapCHECK confirm the attenuation measured by Couch, measured from the measured HU values that are assigned to the MAP-PHAN, check for calculation accuracy for the angled edge of the MapPHAN all come in a range of valid measurement errors do not affect the could see. three ways for the Gantry direction dependence, the first of the meter built into the value of the Gantry $270^{\circ}$ (relative $0^{\circ}$), $90^{\circ}$ (relative $180^{\circ}$), 6X-FFF, 15X from each -1.51, 0.83% and -0.63, -0.22% was not affected by the AP/PA direction represented. Setting the meter horizontally Gantry $90^{\circ}$, $270^{\circ}$ from the couch, Energy 6X-FFF 4.37, 2.84%, 15X, -9.63, -13.32% the difference. By-side direction measurements MapPHAN in value is not within the valid range can not, because that could be confirmed as gamma pass rate 3% of the value is greater than the value shown. You can check the Open Arc 6X-FFF, 15X energy, field size $10{\times}10$ cm $360^{\circ}$ rotation of the dose distribution in the state to look at nearly 90% pass rate to emerge. Conclusion: Based on the above results, the MapPHAN gantry direction dependence by side in the direction of the beam relative dose distribution suitable for measuring the gamma value, but accurate measurement of the absolute dose can not be considered is. this paper, a more accurate treatment plan in order to confirm, Reduce the tolerance for VMAT, such as lateral rotation investigation in order to measure accurate absolute isodose using a combination of IMF (Isocentric Mounting Fixture) MapCHEK 2, will be able to minimize the impact due to the angular dependence.

  • PDF

Experimental investigation of the photoneutron production out of the high-energy photon fields at linear accelerator (고에너지 방사선치료 시 치료변수에 따른 광중성자 선량 변화 연구)

  • Kim, Yeon Su;Yoon, In Ha;Bae, Sun Myeong;Kang, Tae Young;Baek, Geum Mun;Kim, Sung Hwan;Nam, Uk Won;Lee, Jae Jin;Park, Yeong Sik
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.257-264
    • /
    • 2014
  • Purpose : Photoneutron dose in high-energy photon radiotherapy at linear accelerator increase the risk for secondary cancer. The purpose of this investigation is to evaluate the dose variation of photoneutron with different treatment method, flattening filter, dose rate and gantry angle in radiation therapy with high-energy photon beam ($E{\geq}8MeV$). Materials and Methods : TrueBeam $ST{\time}TM$(Ver1.5, Varian, USA) and Korea Tissue Equivalent Proportional Counter (KTEPC) were used to detect the photoneutron dose out of the high-energy photon field. Complex Patient plans using Eclipse planning system (Version 10.0, Varian, USA) was used to experiment with different treatment technique(IMRT, VMAT), condition of flattening filter and three different dose rate. Scattered photoneutron dose was measured at eight different gantry angles with open field (Field size : $5{\time}5cm$). Results : The mean values of the detected photoneutron dose from IMRT and VMAT were $449.7{\mu}Sv$, $2940.7{\mu}Sv$. The mean values of the detected photoneutron dose with Flattening Filter(FF) and Flattening Filter Free(FFF) were measured as $2940.7{\mu}Sv$, $232.0{\mu}Sv$. The mean values of the photoneutron dose for each test plan (case 1, case 2 and case 3) with FFF at the three different dose rate (400, 1200, 2400 MU/min) were $3242.5{\mu}Sv$, $3189.4{\mu}Sv$, $3191.2{\mu}Sv$ with case 1, $3493.2{\mu}Sv$, $3482.6{\mu}Sv$, $3477.2{\mu}Sv$ with case 2 and $4592.2{\mu}Sv$, $4580.0{\mu}Sv$, $4542.3{\mu}Sv$ with case 3, respectively. The mean values of the photoneutron dose at eight different gantry angles ($0^{\circ}$, $45^{\circ}$, $90^{\circ}$, $135^{\circ}$, $180^{\circ}$, $225^{\circ}$, $270^{\circ}$, $315^{\circ}$) were measured as $3.2{\mu}Sv$, $4.3{\mu}Sv$, $5.3{\mu}Sv$, $11.3{\mu}Sv$, $14.7{\mu}Sv$, $11.2{\mu}Sv$, $3.7{\mu}Sv$, $3.0{\mu}Sv$ at 10MV and as $373.7{\mu}Sv$, $369.6{\mu}Sv$, $384.4{\mu}Sv$, $423.6{\mu}Sv$, $447.1{\mu}Sv$, $448.0{\mu}Sv$, $384.5{\mu}Sv$, $377.3{\mu}Sv$ at 15MV. Conclusion : As a result, it is possible to reduce photoneutron dose using FFF mode and VMAT method with TrueBeam $ST{\time}TM$. The risk for secondary cancer of the patients will be decreased with continuous evaluation of the photoneutron dose.

The Location of Medical Facilities and Its Inhabitants' Efficient Utilization in Kwangju City (광주시(光州市) 의료시설(醫療施設)의 입지(立地)와 주민(住民)의 효율적(效率的) 이용(利用))

  • Jeon, Kyung-Sook
    • Journal of the Korean association of regional geographers
    • /
    • v.3 no.2
    • /
    • pp.163-193
    • /
    • 1997
  • Medical services are a fundamental and essential service in all urban areas. The location and accessibility of medical service facilities and institutions are critical to the diagnosis, control and prevention of illness and disease. The purpose of this paper is to present the results of a study on the location of medical facilities in Kwangju and the utilization of these facilities by the inhabitants. The following information is a summary of the findings: (1) Korea, like many countries, is now witnessing an increase in the age of its population as a result of higher living standards and better medical services. Korea is also experiencing a rapid increase in health care costs. To ensure easy access to medical consultation, diagnosis and treatment by individuals, the hierarchical efficient location of medical facilities, low medical costs, equalized medical services, preventive medical care is important. (2) In Korea, the quality of medical services has improved significantly as evident by the increased number of medical facilities and medical personnel. However, there is still a need for not only quantitative improvements but also for a more equitable distribution of and location of medical services. (3) There are 503 medical facilities in Kwangju each with a need to service 2,556 people. This is below the national average of 1,498 inhabitants per facility. The higher locational quotient and satisfactory population per medical facility showed at the civic center. On the other hand, problem regions such as the traditional residential area in Buk-Gu, Moo-deung mountain area and the outer areas of west Kwangju still maintain rural characteristics. (4) In the study area there are 86 general medicine clinics which provide basic medical services. i. e. one clinic per every 14,949 residents. As a basic service, its higher locational quotient showed in the residential area. The lower population concentration per clinic was found in the civic center and in the former town center, Songjeong-dong. In recently build residential areas and in the civic center, the lack of general medicine clinics is not a serious medical services issue because of the surplus of medical specialists in Korea. People are inclined to seek a consultation with a specialist in specific fields rather than consult a general practitioner. As a result of this phenomenon, there are 81 internal medicine facilities. Of these, 32.1% provide services to people who are not referred by a primary care physician but who self-diagnose then choose a medical facility specializing in what they believe to be their health problem. Areas in the city, called dongs, without any internal facilities make up 50% of the total 101 dongs. (5) There are 78 surgical facilities within the area, and there is little difference at the locational appearance from internal medicine facilities. There are also 71 pediatric health clinics for people under 15 years of age in this area, represents one clinic per 5,063 people. On the quantitative aspect, this is a positive situation. Accessibility is the most important facility choice factor, so it should be evenly located in proportion to demander distribution. However, 61% of 102 dongs have no pediatric clinics because of the uneven location. (6) There are 43 obstetrical and gynecological clinics in Kwangju, and the number of residents being served per clinic is 15,063. These services need to be given regularly so it should increase the numbers. There are 37 ENT clinics in the study area with the lower concentration in Dong-gu (32.4%) making no locational differences by dong. There are 23 dermatology clinics with the largest concentration in Dong-Gu. There are 17 ophthalmic clinics concentrated in the residential area because of the primary function of this type of specialization. (7) The use of general medicine clinics, internal medicine clinics, pediatric clinics, ENT clinics by the inhabitants indicate a trend toward primary or routine medical services. Obstetrics and gynecology clinics are used on a regular basis. In choosing a general medicine clinic, internal medicine clinic, pediatric clinic, and a ENT clinic, accessibility is the key factor while choice of a general hospital, surgery clinic, or an obstetrics and gynecology clinic, thes faith and trust in the medical practitioner is the priority consideration. (8) I considered the efficient use of medical facilities in the aspect of locational and management and suggest the following: First, primary care facilities should be evenly distributed in every area. In Kwangju, the number of medical facilities is the lowest among the six largest cities in Korea. Moreover, they are concentrated in Dong-gu and in newly developed areas. The desired number of medical facilities should be within 30 minutes of each person's home. For regional development there is a need to develop a plan to balance, for example, taxes and funds supporting personnel, equipment and facilities. Secondly, medical services should be co-ordinated to ensure consistent, appropriate, quality services. Primary medical facilities should take charge of out-patient activities, and every effort should be made to standardize and equalize equipment and facility resources and to ensure ongoing development and training in the primary services field. A few specialty medical facilities and general hospitals should establish a priority service for incurable and terminally ill patients. (9) The management scheme for the inhabitants' efficient use of medical service is as follows: The first task is to efficiently manage medical facilities and related services. Higher quality of medical services can be accomplished within the rapidly changing medical environment. A network of social, administrative and medical organizations within an area should be established to promote information gathering and sharing strategies to better assist the community. Statistics and trends on the rate or occurrence of diseases, births, deaths, medical and environment conditions of the poor or estranged people should be maintained and monitored. The second task is to increase resources in the area of disease prevention and health promotion. Currently the focus is on the treatment and care of individuals with illness or disease. A strong emphasis should also be placed on promoting prevention of illness and injury within the community through not only public health offices but also via medical service facilities. Home medical care should be established and medical testing centers should be located as an ordinary service level. Also, reduced medical costs for the physically handicapped, cardiac patients, and mentally ill or handicapped patients should be considered.

  • PDF

Evaluation of Error Factors in Quantitative Analysis of Lymphoscintigraphy (Lymphoscintigraphy의 정량분석 시 오류 요인에 관한 평가)

  • Yeon, Joon-Ho;Kim, Soo-Yung;Choi, Sung-Ook;Seok, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.76-82
    • /
    • 2011
  • Purpose: Lymphoscintigraphy is absolutely being used standard examination in lymphatic diagnosis, evaluation after treatment, and it is useful for lymphedema to plan therapy. In case of lymphoscintigraphy of lower-extremity lymphedema, it had an effect on results if patients had not pose same position on the examination of 1 min, 1 hour and 2 hours after injection. So we'll study the methods to improve confidence with minimized quantitative analysis errors by influence factors. Materials and Methods: Being used the Infinia of GE Co. we injected $^{99m}Tc$-phytate 37 MBq (1.0 mCi) 4 sylinges into 40 people's feet hypodermically from June to August 2010 in Samsung Medical Center. After we acquired images of fixed and unfixed condition, we confirmed the count values change by attenuation of soft tissue and bone according to different feet position. And we estimated 5 times increasing 2 cm of distance between $^{99m}Tc$ point source and detector each time to check counts difference according to distance change by different feet position. Finally, we compared 1 and 6 min lymphoscintigraphy images with same position to check the effect of quantitative analysis results owing to difference of amounts of movement of the $^{99m}Tc$-phytate in the lymphatic duct. Results: Percentage difference regarding error values showed minimum 2.7% and maximum 25.8% when comparing fixed and unfixed feet position of lymphoscintigraphy examination at 1 min after injection. And count values according to distance were 173,661 (2 cm), 172,095 (4 cm), 170,996 (6 cm), 167,677 (8 cm), 169,208 counts (10 cm) which distance was increased interval of 2 cm and basal value was mean 176,587 counts, and percentage difference values were not over 2.5% such as 1.27, 1.79, 2.04, 2.42, 2.35%. Also, Assessment results about amounts of movement in lymphatic duct within 6 min until scanning after injection showed minimum 0.15%, and maximum 2.3% which were amounts of movement. We can recognize that error values represent over 20% due to only attenuation of soft tissue and bone except for distance difference (2.42%) and amounts of movement in lymphatic duct (2.3%). Conclusion: It was show that if same patients posed different feet position on the examination of 1 min, 1 hour and 2 hours after injection in the lymphoscintigraphy which is evaluating lymphatic flow of patients with lymphedema and analyzing amount of intake by lymphatic system, maximum error value represented 25.8% due to attenuation of soft tissue and bone, and PASW (Predictive Analytics Software) showed that fixed and unfixed feet position was different each other. And difference of distance between detector and feet and change of count values by difference of examination beginning time after injection influence on quantitative analysis results partially. Therefore, we'll make an effort to fix feet position and make the most of fixing board in lymphoscintigraphy with quantitative analysis.

  • PDF

A Study on Satisfaction and Evaluation of Students현 Spot-Practice in Department of Food and Nutrition (식품영양학과 학생들의 현장실습 만족도 및 평가도에 관한 연구)

  • 최미경;전예숙;홍원주;김순경;김동희;김애정;강명화;김미현
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.33 no.2
    • /
    • pp.373-380
    • /
    • 2004
  • The purpose of this study was to estimate satisfaction and evaluation degree of students' spot-practice in department of food and nutrition and to investigate relating factors to them for development of spot-practice Programme. The survey for analysis was conducted through the questionnaires to 229 students finished internship. Proportions of the students were 93.9% for senior, 93.9% for female. Proportions of spot-practice facilities were 38.9%, 46.7%, and 14.4% for school, business & industry, and hospital respectively. The major part of subjects (83.8%) took part in spot-practice during 2 weeks. The satisfaction scores to spot-practice were the lowest for pay, and the highest for a kind of spot-practice facilities. The evaluation scores were the lowest for 'I made a plan and prepared my work in advanced', and the highest for 'I did my best for doing my work'. The satisfaction score in hospital was significantly lower than those in school or business & industry. The satisfaction score in self-operated foodservice was significantly higher than that in contract managed one. However, there no significant differences in evaluation scores by foodsevice employment type. In the case of coincidence of area in spot-practice and residence, or facilities of spot-practice and job desired, the satisfaction and evaluation scores were significantly higher than those of others. The period of spot-practice was significantly positively correlated with satisfaction scores for atmosphere of spot-practice facilities, service and treatment for spot-practice student, while negatively correlated with evaluation score for 'I did my best for doing my work'. The spot-practice pay was significantly positively correlated with satisfaction and evaluation scores for various items. In conclusion, various factors are related to satisfaction and evaluation degree of spot-practice students, and consist concern and support from college St university, foodservice institution, and government for systematic spot-Practice are required.

Clinical Usefulness of Implanted Fiducial Markers for Hypofractionated Radiotherapy of Prostate Cancer (전립선암의 소분할 방사선치료 시에 위치표지자 삽입의 유용성)

  • Choi, Young-Min;Ahn, Sung-Hwan;Lee, Hyung-Sik;Hur, Won-Joo;Yoon, Jin-Han;Kim, Tae-Hyo;Kim, Soo-Dong;Yun, Seong-Guk
    • Radiation Oncology Journal
    • /
    • v.29 no.2
    • /
    • pp.91-98
    • /
    • 2011
  • Purpose: To assess the usefulness of implanted fiducial markers in the setup of hypofractionated radiotherapy for prostate cancer patients by comparing a fiducial marker matched setup with a pelvic bone match. Materials and Methods: Four prostate cancer patients treated with definitive hypofractionated radiotherapy between September 2009 and August 2010 were enrolled in this study. Three gold fiducial markers were implanted into the prostate and through the rectum under ultrasound guidance around a week before radiotherapy. Glycerin enemas were given prior to each radiotherapy planning CT and every radiotherapy session. Hypofractionated radiotherapy was planned for a total dose of 59.5 Gy in daily 3.5 Gy with using the Novalis system. Orthogonal kV X-rays were taken before radiotherapy. Treatment positions were adjusted according to the results from the fusion of the fiducial markers on digitally reconstructed radiographs of a radiotherapy plan with those on orthogonal kV X-rays. When the difference in the coordinates from the fiducial marker fusion was less than 1 mm, the patient position was approved for radiotherapy. A virtual bone matching was carried out at the fiducial marker matched position, and then a setup difference between the fiducial marker matching and bone matching was evaluated. Results: Three patients received a planned 17-fractionated radiotherapy and the rest underwent 16 fractionations. The setup error of the fiducial marker matching was $0.94{\pm}0.62$ mm (range, 0.09 to 3.01 mm; median, 0.81 mm), and the means of the lateral, craniocaudal, and anteroposterior errors were $0.39{\pm}0.34$ mm, $0.46{\pm}0.34$ mm, and $0.57{\pm}0.59$ mm, respectively. The setup error of the pelvic bony matching was $3.15{\pm}2.03$ mm (range, 0.25 to 8.23 mm; median, 2.95 mm), and the error of craniocaudal direction ($2.29{\pm}1.95$ mm) was significantly larger than those of anteroposterior ($1.73{\pm}1.31$ mm) and lateral directions ($0.45{\pm}0.37$ mm), respectively (p<0.05). Incidences of over 3 mm and 5 mm in setup difference among the fractionations were 1.5% and 0% in the fiducial marker matching, respectively, and 49.3% and 17.9% in the pelvic bone matching, respectively. Conclusion: The more precise setup of hypofractionated radiotherapy for prostate cancer patients is feasible with the implanted fiducial marker matching compared with the pelvic bony matching. Therefore, a less marginal expansion of planning target volume produces less radiation exposure to adjacent normal tissues, which could ultimately make hypofractionated radiotherapy safer.

INDIVIDUALIZED RECONSTRUCTION OF THE LOWER OCCLUSAL PLANE ACCORDING TO SKELETAL PATTERN (안면 골격 형태에 따른 하악 교합평면의 재구성)

  • Hyun, Seong-Wook
    • The korean journal of orthodontics
    • /
    • v.25 no.4
    • /
    • pp.465-485
    • /
    • 1995
  • The purpose of this study is to locate the proper position of the lower occlusal plane according to individual skeletal pattern. Cephalometric films of 234 subjects of the control group, 358 of the pretreatment group and 358 of the treated group were analyzed to study proper relationships between vertical dimension ratio(VDR) and lower occlusomandibular plane angle(LOM). The control group was divided into two subgroups by the age. The first subgroup consisted of 113 subjects of the age 14 years and under and with the mean age of 10.82 years. The other subgroup consisted of 113 subjects of the age 18 years and above with the mean age of 23.76 years. The pretreatment group was divided into three subgroups by the age. The first subgroup consisted of 274 subjects of the age 14 years and under with the mean age of 11.36 years. The second subgroup consisted of 54 subjects of the age 14 through 18 years with the mean age of 15.4 years. The last subgroup consisted of 30 subjects of the age 18 years and above with the mean age of 21.35 years. The treated group was also divided into three subgroups by the age. The first subgroup consisted of 145 subjects of the age 14 years and under with the mean age of 12.91 years. The second subgroup consisted of 166 subjects of the age 14 through 18 years with the mean age of 15.64 years. The last subgroup consisted of 47 subjects of the age 18 years and above with the mean age of 21.61 years. Cephalometric films of the sample were traced. Measurements were made to a hundredth using a program specifically prepared for this study, and the results were entered into a 486DX PC. Means and Standard deviations of all the veriables were calculated for each group. Correlation coefficients between pertinent variables were calculated. Significance tests on those coefficients, one-way ANOVA and t-tests between variables or groups were performed. On the basis of the results studied above, certain subjects were selected from the control and the treated groups to locate the proper position of the occlusal plane, and designated as the optimal occluaion group. The subjects of this optimal occlusion group had 1-3 mm overbite, 1-3 mm of overjet and less than 1.75 mm of curve of Spee. A total subjects of 187 in this group consisted 104 treated subjects and 83 control group. Regression analysis was carried out between VDR and LOM, and regression equations were tabulated for this optimal occlusion group. The results were as follows : 1. Highly significant correlations were observed between various variables useful for identifying vertical component of skeletal frame, but any one particular variable did not accurately indicate the magnitude of anterior vertical overbite. 2. Of the variables useful identifying vertical component of skeletal frame, The VDR showed the highest correlation to the LOM. 3. Of the total sample, 80 percent had overbite within the normal range, irrespective of VDR. 4. The optimal occlusion group was divided into 9 subgroups by the age and the anteroposterior skeletal pattern, and correlation coefficient and determination coefficient between VDR and LOM of each group were calculated. Correlation coefficients and determination coefficients were found to be significantly high in all groups. 5. Regression equation was induced for each of the optimal occlusion group to find proper LOM according to the VDR. 6. It was found that the mean value of the cant of occlusal plane itself is not enough for a diagnosis and a treatment plan. Rather, It is very important to locate the proper occlusal plane for an Individual skeletal pattern.

  • PDF

The Characteristics and the Effects of Pollutant Loadings from Nonpoint Sources on Water Quality in Suyeong Bay (수영만 수질에 미치는 비점원 오염부하의 특성과 영향)

  • CHO Eun Il;LEE Suk Mo;PARK Chung-Kil
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.28 no.3
    • /
    • pp.279-293
    • /
    • 1995
  • The most obvious and easily recognizable sources of potential water pollution are point sources such as domestic and industrial wastes. But recently, the potential effects of nonpoint sources on water quality have been increased apparently. In order to evaluate the characteristics and the effects of nonpoint sources on water quality, this study was performed in Suyeong Bay from May, 1992 to July, 1992. The depth-averaged 2-dimensional numerical model, which consists of the hydrodynamic model and the diffusion model was applied to simulate the water quality in Suyeong Bay. When flowrate was $65.736m^3/s,$ the concentration of pollutants (COD, TSS and VSS) at Oncheon stream (Sebeong bridge) during second flush were very high as much as 121.4mg/l of COD, 1148.0mg/l of TSS and 262.0mg/1 of VSS. When flowrate was 4.686m^3/s, the concentration of pollutants $(TIN,\;NH_4\;^+-\;N,\;NO_2\;^--N\;and\;PO_4\;^{3-}-P)$ during the first flush were very high as much as 20.306mg/1 of TIN, 14.154mg/1 of $NH_4\;^+-N$, 9.571mg/l of $NO_2\;^--N$ and l.785mg/l of $PO_2\;^{3-}-P$ As results of the hydrodynamic model simulation, the computed maximum velocity of tidal currents in Suyeong Bay was 0.3m/s and their direction was clockwise flow for ebb tide and counter clockwise flow for Hood tide. Four different methods were applied for the diffusion simulation in Suyeong Bay. There were the effects for the water quality due to point loads, annual nonpoint loads and nonpoint loads during the wet weather and the investigation period, respectively. The efforts of annual nonpoint loads and nonpoint loads during the wet weather seem to be slightly deteriorated in comparison with the effects of point loads. However, the bay was significantly polluted by the nonpoint loads during the investigation period. In this case, COD and SS concentrations ranged 2.0-30.0mg/l, 7.0- 200.0mg/l in ebb tide, respectively. From these results, it can be emphasized that the large amount of pollutants caused by nonpoint sources during the wet weather were discharged into the bay, and affected significantly to both the water quality and the marine ecosystem. Therefore, it is necessary to consider the loadings of nonpoint pollutants to plan wastewater treatment plant.

  • PDF

Breathing Reserve Index at Anaerobic Threshold of Cardiopulmonary Exercise Test in Chronic Obstructive Pulmonary Disease (만성폐쇄성 폐질환의 운동부하 심폐기능검사에서 무산소역치 예비호흡지수의 의의)

  • Lee, Byoung-Hoon;Kang, Soon-Bock;Park, Sung-Jin;Jee, Hyun-Suk;Choi, Jae-Chol;Park, Yong-Bum;Ahn, Chang-Hyuk;Kim, Jae-Yeol;Park, In-Won;Choi, Byung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.795-802
    • /
    • 1999
  • Objective : Cardiopulmonary exercise test is a useful tool to evaluate the operative risk and to plan exercise treatment for the patients with chronic obstructive pulmonary disease(COPD). In cardiopulmonary exercise test, most of the measured parameters are recorded at the time of peak exercise, which are hard to attain in COPD patients. So we evaluated the usefulness of the parameter, breathing reserve index(BRI=minute ventilation [$V_E$]/maximal voluntary ventilation[MVV]) at the time of anaerobic threshold($BRI_{AT}$) for the differentiation of COPD patients with normal controls. Methods : Thirty-six COPD patients and forty-two healthy subjects underwent progressive, incremental exercise test with bicycle ergometer upto possible maximal exercise. All the parameters was measured by breath by breath method. Results : The maximal oxygen uptake in COPD patients (mean$\pm$SE) was $1061.2{\pm}65.6ml/min$ which was significantly lower than $2137.6{\pm}91.4ml/min$ of normal subjects(p<0.01). Percent predicted maximal oxygen uptake was 54.3% in COPD patients and 86.0% in normal subjects(p<0.01). Maximal exercise(respiratory quotient; $VCO_2/VO_2{\geq}1.09$) was accomplished in 7 of 36 COPD patients(19.4%) and in 18 of 42 normal subjects(42.9%). The $BRI_{AT}$ of COPD patients was higher($0.50{\pm}0.03$) than that of control subject($028{\pm}0.02$, p<0.01), reflecting early hyperventilation in COPD patient during exercise. The correlation between $BRI_{AT}$ and BRI at maximal exercise in COPD patients was good(r=0.9687, p<0.01). Conclusion : The $BRI_{AT}$ could be a useful parameter for the differentiation of COPD patients with normal controls in the submaximal cardiopulmonary exercise test.

  • PDF

USABILITY EVALUATION OF PLANNING MRI ACQUISITION WHEN CT/MRI FUSION OF COMPUTERIZED TREATMENT PLAN (전산화 치료계획의 CT/MRI 영상 융합 시 PLANNING MRI영상 획득의 유용성 평가)

  • Park, Do-Geun;Choe, Byeong-Gi;Kim, Jin-Man;Lee, Dong-Hun;Song, Gi-Won;Park, Yeong-Hwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.127-135
    • /
    • 2014
  • Purpose : By taking advantage of each imaging modality, the use of fused CT/MRI image has increased in prostate cancer radiation therapy. However, fusion uncertainty may cause partial target miss or normal organ overdose. In order to complement such limitation, our hospital acquired MRI image (Planning MRI) by setting up patients with the same fixing tool and posture as CT simulation. This study aims to evaluate the usefulness of the Planning MRI through comparing and analyzing the diagnostic MRI image and Planning MRI image. Materials and Methods : This study targeted 10 patients who had been diagnosed with prostate cancer and prescribed nonhormone and definitive RT 70 Gy/28 fx from August 2011 to July 2013. Each patient had both CT and MRI simulations. The MRI images were acquired within one half hour after the CT simulation. The acquired CT/MRI images were fused primarily based on bony structure matching. This study measured the volume of prostate in the images of Planning MRI and diagnostic MRI. The diameters at the craniocaudal, anteroposterior and left-to-right directions from the center of prostate were measured in order to compare changes in the shape of prostate. Results : As a result of comparing the volume of prostate in the images of Planning MRI and diagnostic MRI, they were found to be $25.01cm^3$(range $15.84-34.75cm^3$) and $25.05cm^3$(range $15.28-35.88cm^3$) on average respectively. The diagnostic MRI had an increase of 0.12 % as compared with the Planning MRI. On the planning MRI, there was an increase in the volume by $7.46cm^3$(29 %) at the transition zone directions, and there was a decrease in the volume by $8.52cm^3$(34 %) in the peripheral zone direction. As a result of measuring the diameters at the craniocaudal, anteroposterior and left-to-right directions in the prostate, the Planning MRI was found to have on average 3.82cm, 2.38cm and 4.59cm respectively and the diagnostic MRI was found to have on average 3.37cm, 2.76cm and 4.51cm respectively. All three prostate diameters changed and the change was significant in the Planning MRI. On average, the anteroposterior prostate diameter decrease by 0.38cm(13 %). The mean right-to-left and craniocaudal diameter increased by 0.08cm(1.6 %) and 0.45cm(13 %), respectively. Conclusion : Based on the results of this study, it was found that the total volumes of prostate in the Planning MRI and the diagnostic MRI were not significantly different. However, there was a change in the shape and partial volume of prostate due to the insertion of prostate balloon tube to the rectum. Thus, if the Planning MRI images were used when conducting the fusion of CT/MRI images, it would be possible to include the target in the CTV without a loss as much as the increased volume in the transition zone. Also, it would be possible to reduce the radiation dose delivered to the rectum through separating more clearly the reduction of peripheral zone volume. Therefore, the author of this study believes that acquisition of Planning MRI image should be made to ensure target delineation and localization accuracy.