• Title/Summary/Keyword: trapezoidal rule method

Search Result 56, Processing Time 0.029 seconds

Bioequivalence of AmbrectTM Tablet to MucopectTM Tablet (Ambroxol hydrochloride 30 mg) (뮤코펙트 정(염산암브록솔 30 mg)에 대한 암브렉트 정의 생물학적 동등성)

  • Yoo, Jeong-Yeon;Joung, Sun-Koung;Choi, Mee-Hee;Han, Sang-Beom;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.33 no.3
    • /
    • pp.215-221
    • /
    • 2003
  • A bioequivalence study of $Ambrect^{TM}$ tablets (Dong Wha Pharm. Ind. Co., Ltd.) to $Mucopect^{TM}$ tablets (Boehringer Ingelheim Korea, Ltd.) was conducted according to the guideline of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korea volunteers received each medicine at the ambroxol hydrochloride dose of 30 mg in a $2{\times}2$ crossover study. There was a one-week wash out period between the doses. Plasma concentrations of ambroxol were monitored by a high-performance liquid chromatography for over a period of 24 hours after the administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calulated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}\;(time\;to\;reach\;C_{max})$ were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Ambrect^{TM}/Mucopect^{TM}$ were 0.89-1.01 and 0.89-1.02, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Ambrect^{TM}\;and\;Mucopect^{TM}$ with respect to the rate and extent of absorption.

Bioequivalence of DilastTM Capsule to Ketas® Capsule (Ibudilast 10 mg) (케타스캅셀(이부딜라스트 10 mg)에 대한 딜라스트캡슐의 생물학적동등성)

  • Chang, Kyu-Young;Kang, Seong-Woo;Yoo, Eun-Ju;Lew, Soo-Hyun;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.3
    • /
    • pp.197-203
    • /
    • 2007
  • A bioequivalence study of $Dilast^{TM}$ Capsule (Chong Kun Dang Pharma. Co., Ltd.) to $Ketas^{(R)}$ Capsule (Han Dok Pharma. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty eight healthy male Korean volunteers received each medicine at the ibudilast dose of 20 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of ibudilast were monitored by a liquid chromatography-tandem mass spectrometry (LC-MS/MS) for over a period of 36 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 36 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Dilast^{TM}$ $Capsule/Ketas^{(R)}$ Capsule were $log0.93{\sim}log1.06$ and $log0.93{\sim}log1.11$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Thus, our study demonstrated the bioequivalence of $Dilast^{TM}$ Capsule and $Ketas^{(R)}$ Capsule with respect to the rate and extent of absorption.

Bioequivalence Study of Toriem® Tablet to Motilium-M® Tablet (Domperidone Maleate 12.72 mg) Evaluated by Liquid Chromatography/Tandem Mass Spectrometry

  • Ryu, Ju-Hee;Choi, Sang-Jun;Lee, Myung-Jae;Lee, Jin-Sung;Kang, Jong-Min;Tak, Sung-Kwon;Seo, Ji-Hyung;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.1
    • /
    • pp.65-71
    • /
    • 2009
  • The aim of the present study was to evaluate the bioequivalence of two domperidone maleate tablets, Motilium-$M^{(R)}$ Tablet (Janssen Korea Ltd., reference product) and $Toriem^{(R)}$ Tablet (Daewon Pharm. Co., Ltd., test product). Domperidone was extracted by liquid-liquid extraction using tert-butyl methyl ether and separated in less than 3 min on $C_{18}$ reverse-phase column using an isocratic elution. A tandem mass spectrometer, as detector, was used for quantitative analysis in positive mode by a multiple reaction monitoring mode to monitor the m/z $426.1{\rightarrow}119.1$ and the m/z $837.4{\rightarrow}158.2$ transitions for domperidone and the internal standard (roxithromycin), respectively. Calibration curves, from $0.05{\sim}50$ ng/mL of domperidone, showed correlation coefficients (r) higher than 0.9941. Intra day and inter day precision (C.V. %) for quality control were ranged from 10.04 to 16.09% and from 10.87 to 18.69%, respectively. The lower limit of quantification (LLOQ) of domperidone was 0.05 ng/mL. The method described is precise and sensitive and has been successfully applied to the study of bioequivalence of domperidone in 24 healthy Korean volunteers. Twenty-four healthy male Korean volunteers received a single dose of each medicine ($2{\times}12.72\;mg$ domperidone maleate) in a $2{\times}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of domperidone were monitored for over a period of 24 hr after the administration. $AUC_{0-t}$ (the area under the plasma concentration-time curve) was calculated by the linear trapezoidal rule. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. The 90% confidence intervals for the log transformed data were within acceptable range of log 0.8 to log 1.25 (e.g., $log\;0.92{\sim}log\;1.05$ for $AUC_{0-t}$, $log\;0.81{\sim}log\;1.05$ for $C_{max}$). The major parameters, $AUC_{0-t}$ and $C_{max}$ met the criteria of KFDA for bioequivalence indicating that $Toriem^{(R)}$ tablet is bioequivalent to Motilium-$M^{(R)}$ tablet.

Bioequivalence of FLUTAL Tablet to SOMALGEN Tablet (Talniflumate 370 mg) (소말겐 정(탈니플루메이트 370 mg)에 대한 플루탈 정의 생물학적동등성)

  • Lee, Heon-Woo;Cho, Sung-Hee;Park, Wan-Su;Im, Ho-Taek;Kim, Young-Kwan;Rew, Jae-Hwan;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.35 no.4
    • /
    • pp.303-308
    • /
    • 2005
  • The purpose of the present study was to evaluate the bioequivalence of two talniflumate tablets, SOMALGEN tablet (Kun Wha Pharm. Co., Ltd., Seoul, Korea, reference drug) and FLUTAL tablet (Kukje Pharm. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received two tablets at the talniflumate dose of 740 mg in a $2{\pm}2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of niflumic acid were monitored by an HPLC-UV for over a period of 14 hr after the administration. $AUC_t$(the area under the plasma concentration-time curve from time zero to 14 hr) was calculated by the linear trapezoidal rule method. $C_{max}$(maximum plasma drug concentration) and $T_{max}$(time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$, $C_{max}$ and untransformed $T_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$, ratio and the $C_{max}$ ratio for SOMALGEN/FLUTAL were $log0.8510{\sim}log1.0318$ and $log0.9264{\sim}log1.0607$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Taken together, our study demonstrated the bioequivalence of SOMALGEN and FLUTAL with respect to the rate and extent of absorption.

Bioequivalence Of SudoTM Ranitidine Hydrochloride Tablet to CuranTM Tablet (Ranitidine Hydrochloride 150 mg) (큐란 정(염산라니티딘 150 mg)에 대한 수도염산라니티딘정의 생물학적동등성)

  • Lee, Sun-Neo;Ko, Youn-Jung;Kang, Seung-Woo;Yoon, Seo-Hyun;Park, Moo-Sin;Lee, Ye-Ri;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.3
    • /
    • pp.193-199
    • /
    • 2006
  • A bioequivalence study of $Sudo^{TM}$ Ranitidine HCI tablet (Sudo Pharma. Ind. Co., Ltd.) to $Curan^{TM}$ tablet (Il Dong Pharma. Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty four healthy male Korean volunteers received each medicine at the ranitidine hydrochloride dose of 150 mg in a 2x2 crossover study. There was a one week wash-out period between the doses. Plasma concentrations of ranitidine were monitored by a high-turbulent liquid chromatography (HTLC) for over a period of 12 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found far all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Sudo^{TM}$ Ranitidine $HCl/Curan^{TM}$ were 0.92-1.00 and 0.90-1.03, respectively. These values were within the acceptable bioequivalence intervals of 0.80-1.25. Thus, our study demonstrated the bioequivalence of $Sudo^{TM}$ Ranitidine HCI and $Curan^{TM}$ with respect to the rate and extent of absorption.

Bioequivalence of MelaxTM Capsule to MobicTM Capsule (Meloxicam 7.5 mg) (모빅 캡슐(멜록시캄 7.5 mg)에 대한 멜락스 캡슐의 생물학적동등성)

  • Lee, Ye-Rie;Yeom, Seung-Bock;Ko, Youn-Jung;Ko, Jung-Kil;Kim, Ho-Hyun;Lee, Hee-Joo;Lee, Kyung-Ryul
    • Journal of Pharmaceutical Investigation
    • /
    • v.34 no.5
    • /
    • pp.413-418
    • /
    • 2004
  • A bioequivalence of $Melax^{TM}$ capsules (Chong Kun Dang Pharm., Korea) and $Mobic^{TM}$ capsules (Boehringer Ingelheim Korea) was evaluated according to the guideline of Korea Food and Drug Administration (KFDA). Single 15 mg dose of meloxicam of each medicine was administered orally to 24 healthy male volunteers. This study was performed in a $2\;{\times}\;2$ crossover design. Concentrations of meloxicam in human plasma were monitored by a high-performance liquid chromatography. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 72 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was performed using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Melax^{TM}/Mobic^{TM}$ were 0.95 - 1.04 and 0.98 - 1.14, respectively. This study demonstrated a bioequivalence of $Melax^{TM}$ and $Mobic^{TM}$ with respect to the rate and extent of absorption.

Bioequivalence of LosartanTM Tablet to CozzarTM Tablet (Losartan Kalium 50 mg) (코자 정(로자탄 칼륨 50 mg)에 대한 로자르탄 정의 생물학적동등성)

  • Kim, Yong-Won;Park, Wan-Su;Kim, Sung-Su;Seo, Ji-Hyung;Cho, Sung-Hee;Lee, Heon-Woo;Rew, Jae-Hwan;Lee, Kyung-Tae
    • Journal of Pharmaceutical Investigation
    • /
    • v.36 no.2
    • /
    • pp.131-136
    • /
    • 2006
  • The purpose of the present study was to evaluate the bioequivalence of two losartan tablets, $Cozaar^{TM}$ tablet (MSD Korea. Co., Ltd., Seoul, Korea, reference drug) and $Losartan^{TM}$ tablet (DaeWon Pharm. Co., Ltd., Korea, test drug), according to the guidelines of Korea Food and Drug Administration (KFDA). Twenty-four healthy male Korean volunteers received two tablets at the losartan kalium dose of 100 mg in a $2\;{\time}\;2$ crossover study. There was a one-week washout period between the doses. Plasma concentrations of losartan were monitored by an LC-MS/MS for over a period of 12 hr after the administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 12 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for $Cozaar^{TM}/Losartan^{TM}$ were $log\;0.97{\sim}log\;1.12\;and\;log\;0.93{\sim}log\;1.23$, respectively. These values were within the acceptable bioequivalence intervals of $log\;0.80{\sim}log\;1.25$. Taken together, our study demonstrated the bioequivalence of $Cozaar^{TM}$ and $Losartan^TM$ with respect to the rate and extent of absorption.

Bioequivalence of NimegenTM Soft Capsule to RoAccutane® Soft Capsule (Isotretinoin 10 mg) (로아큐탄 연질캡슐(이소트레티노인 10 mg)에 대한 니메겐 연질캡슐의 생물학적동등성)

  • Yang, Seung-Kwon;La, Sook-Ie;Chang, Kyu-Young;Lee, Yun-Young;Yoon, Mi-Kyeong;Lew, Soo-Hyun;Lee, Kyung-Ryul;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.37 no.4
    • /
    • pp.255-261
    • /
    • 2007
  • A bioequivalence study of $Nimegen^{TM}$ soft capsule (Medica Korea Pharma. Co., Ltd.) to $RoAccutane^{(R)}$ soft capsule (Roche Korea Ind. Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Thirty healthy male Korean volunteers received each medicine at the isotretinoin dose of 60 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of isotretinoin were monitored by a high performance liquid chromatography (HPLC) for over a period of 48 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 48 hr) was calculated by the linear trapezoidal rule method. $C_{MAX}$ (maximum plasma drug concentration) and $T_{MAX}$ (time to reach $C_{MAX}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t\;and\;C_{MAX}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{MAX}$ ratio for $Nimegen^{TM}/RoAccutane^{(R)}$ were $log0.860{\sim}log0.98\;and\;log0.85{\sim}log1.00$, respectively. These values were within the acceptable bioequivalence intervals of $log0.80{\sim}log1.25$. Thus, our study demonstrated the bioequivalence of $Nimegen^{TM}\;and\;RoAccutane^{(R)}$ with respect to the rate and extent of absorption.

Enhanced Variable Structure Control With Fuzzy Logic System

  • Charnprecharut, Veeraphon;Phaitoonwattanakij, Kitti;Tiacharoen, Somporn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.999-1004
    • /
    • 2005
  • An algorithm for a hybrid controller consists of a sliding mode control part and a fuzzy logic part which ar purposely for nonlinear systems. The sliding mode part of the solution is based on "eigenvalue/vector"-type controller is used as the backstepping approach for tracking errors. The fuzzy logic part is a Mamdani fuzzy model. This is designed by applying sliding mode control (SMC) method to the dynamic model. The main objective is to keep the update dynamics in a stable region by used SMC. After that the plant behavior is presented to train procedure of adaptive neuro-fuzzy inference systems (ANFIS). ANFIS architecture is determined and the relevant formulation for the approach is given. Using the error (e) and rate of error (de), occur due to the difference between the desired output value (yd) and the actual output value (y) of the system. A dynamic adaptation law is proposed and proved the particularly chosen form of the adaptation strategy. Subsequently VSC creates a sliding mode in the plant behavior while the parameters of the controller are also in a sliding mode (stable trainer). This study considers the ANFIS structure with first order Sugeno model containing nine rules. Bell shaped membership functions with product inference rule are used at the fuzzification level. Finally the Mamdani fuzzy logic which is depends on adaptive neuro-fuzzy inference systems structure designed. At the transferable stage from ANFIS to Mamdani fuzzy model is adjusted for the membership function of the input value (e, de) and the actual output value (y) of the system could be changed to trapezoidal and triangular functions through tuning the parameters of the membership functions and rules base. These help adjust the contributions of both fuzzy control and variable structure control to the entire control value. The application example, control of a mass-damper system is considered. The simulation has been done using MATLAB. Three cases of the controller will be considered: for backstepping sliding-mode controller, for hybrid controller, and for adaptive backstepping sliding-mode controller. A numerical example is simulated to verify the performances of the proposed control strategy, and the simulation results show that the controller designed is more effective than the adaptive backstepping sliding mode controller.

  • PDF

Bioequivalence of LANIDIEM® Tablet 4 mg to Vaxar® Tablet 4 mg(Lacidipine 4 mg) (박사르®정 4 밀리그램(라시디핀 4 mg)에 대한 라니디엠®정 4 밀리그램의 생물학적동등성)

  • Lee, Yun-Young;Kim, Hye-Jin;La, Sookie;Cho, Kyung-Hee;Jang, Moon-Sun;Park, Young-Joon;Lee, Hee-Joo
    • Journal of Pharmaceutical Investigation
    • /
    • v.40 no.2
    • /
    • pp.125-131
    • /
    • 2010
  • A bioequivalence study of LANIDIEM$^{(R)}$ tablet 4 mg (Samil. Co., Ltd.) to Vaxar$^{(R)}$ tablet 4 mg (GlaxoSmithKline Co., Ltd.) was conducted according to the guidelines of Korea Food and Drug Administration (KFDA). Forty healthy male Korean volunteers were enrolled in the study and thirty six volunteers completed the study according to the protocol. Thirty six volunteers received each medicine at the lacidipine dose of 4 mg in a $2{\times}2$ crossover study. There was one week wash-out period between the doses. Plasma concentrations of lacidipine were monitored by a high performance liquid chromatography - tandem mass spectrometry (LC-MS/MS) for over a period of 24 hours after drug administration. $AUC_t$ (the area under the plasma concentration-time curve from time zero to 24 hr) was calculated by the linear trapezoidal rule method. $C_{max}$ (maximum plasma drug concentration) and $T_{max}$ (time to reach $C_{max}$) were compiled from the plasma concentration-time data. Analysis of variance was carried out using logarithmically transformed $AUC_t$ and $C_{max}$. No significant sequence effect was found for all of the bioavailability parameters indicating that the crossover design was properly performed. The 90% confidence intervals of the $AUC_t$ ratio and the $C_{max}$ ratio for LANIDIEM$^{(R)}$/Vaxar$^{(R)}$ were log 0.8102~log 1.0417 and log 0.8493~log 1.1439, respectively. These values were within the acceptable bioequivalence intervals of log 0.80~log 1.25. Thus, our study demonstrated the bioequivalence of LANIDIEM$^{(R)}$ tablet 4 mg and Vaxar$^{(R)}$ tablet 4 mg with respect to the rate and extent of absorption.