• 제목/요약/키워드: transpedicular approach

검색결과 9건 처리시간 0.021초

Ultrasound-Guided Posterolateral Approach for Midline Calcified Thoracic Disc Herniation

  • Tan, Lee A.;Lopes, Demetrius K.;Fontes, Ricardo B.V.
    • Journal of Korean Neurosurgical Society
    • /
    • 제55권6호
    • /
    • pp.383-386
    • /
    • 2014
  • Objective : Symptomatic thoracic disc herniation often requires prompt surgical treatment to prevent neurological deterioration and permanent deficits. Anterior approaches offer direct visualization and access to the herniated disc and anterior dura but require access surgeons and are often associated with considerable postoperative pain and pulmonary complications. A disadvantage with using posterior approaches in the setting of central calcified thoracic disc herniation however, has been the limited visualization of anterior dura and difficulty to accurately assess the extent of decompression. Methods : We report our experience with intraoperative ultrasound (US) guidance during a modified posterior transpedicular approach for removal of a central calcified thoracic disc herniation with a review of pertinent literature. Results : The herniated thoracic disc was successfully removed with posterior approach with the aid of intraoperative US. The patient had significant neurological improvement at three months follow-up. Conclusion : Intraoperative ultrasound is a simple yet valuable tool for real-time imaging during transpedicular thoracic discectomy. Visualization provided by intraoperative US increases the safety profile of posterior approaches and may make thoracotomy unnecessary in a selected group of patients, especially when a patient has existing pulmonary disease or is otherwise not medically fit for the transthoracic approach.

흉추에서의 경척추경 접근법을 통한 경피적 척추체성형술 및 척추체 후만변형 복원술에 관한 후향성 연구 (Retrograde Study on Thoracic Percutaneous Vertebroplasty and Kyphoplasty Done by Transpedicular Approach)

  • 조주연;배영곤;김양현;이은형;이철중;이상철;김용락
    • The Korean Journal of Pain
    • /
    • 제18권2호
    • /
    • pp.204-207
    • /
    • 2005
  • Background: Transpedicular percutaneous vertebroplasty, along with kyphoplasty of the thoracic vertebrae, is technically more difficult than those of the lumbar vertebrae due to the anatomical differences. During the last four years, all the percutaneous vertebroplasty and kyphoplasty of the thoracic vertebrae carried out at our institution were performed using a transpedicular approach; therefore, we tried to find if there were any problems or complications associated with the process. Methods: The medical records of all the patients who had undergone thoracic percutaneous vertebroplasty or kyphoplasty were retrospectively reviewed. The following were looked up: the procedure name, unipedicular or bipedicular, the level of the thoracic vertebrae treated, and the pre- and postoperative changes in the Visual Analog Scales (VAS), the volume of cement injected and complications. Results: In the last four years, 58 vertebral bodies in 58 patients were treated. Twelve and 46 vertebral bodies were treated by kyphoplasty and vertebroplasty, respectively. A total of 58 mid and lower thoracic levels were treated: T5 (n=1), T6 (n=1), T7 (n=3), T8 (n=4), T9 (n=1), T10 (n=4), T11 (n=14) and T12 (n=30). The mean preoperative and postoperative VAS scores were $8.1{\pm}1.4$ and $5.2{\pm}1.7$, respectively. The mean volume of cement injected was $4.01{\pm}1.85ml$; $3.18{\pm}0.60ml$ at T5-8 and $4.22{\pm}2.27ml$ at T9-12. There were no clinical complications, such as pedicular fracture or cement leakage. Conclusions: Although transpedicular vertebroplasty and kyphoplasty at the mid to lower thoracic vertebral bodies is technically difficult compared to that at the lumbar region, the procedures can be performed safely.

골다공증성 추체골절에 대한 경피적 척추성형술 : 초기성적 (Percutaneous Vertebroplasty in Treatment of Osteoporotic Vertebral Body Fractures : Early Result)

  • 유영상;신재학;김일만
    • Journal of Korean Neurosurgical Society
    • /
    • 제30권2호
    • /
    • pp.163-167
    • /
    • 2001
  • Objective : Percutaneous vertebroplasty has recently been introduced as an interesting therapeutic alternative for the treatment of thoracolumbar vertebral body fractures in elderly persons with osteoporosis. The authors present the early results of this method. Method and Material : From July 1999 to April 2000, percutaneous transpedicular technique was used in 20 patients (2 men and 18 women) whose mean age was 67.5 years old(range 59-79) with painful vertebral compression(22) and burst(2) fractures. The interval between fracture and vertebroplasty ranged 1 day to 4 months. The procedure involved percutaneous puncture of the injured vertebra via transpedicular approach under fluoroscopic guidance, followed by injection of polymethylmetacrylate(PMMA) into the vertebral body through a disposable 11-guage Jamshidi needle. Result : The most common cause of fracture was slip down and the most frequent injured level was the twelfth thoracic spine. The procedure was technically successful bilaterally in 18 patients(9 thoracic and 15 lumbar spines) with an average injection amount of 7.7ml PMMA in each level. Seventeen(94.4%) patients reported significant pain relief immediately after treatment. Two leaks of PMMA were detected with postoperative CT in spinal epidural space and extravertebral soft tissue without clinical symptoms. Conclusion : Although this study represents the early results, percutaneous vertebroplasty seems to be valuable tool in the treatment of painful osteoporotic vertebral body fractures in elderly, providing acute pain relief and early mobilization.

  • PDF

흉추 압박골절환자를 위한 경피적 척추성형술의 새로운 접근법 -증례 보고- (A New Method of Approach for Percutaneous Thoracic Vertebroplasty in Vertebral Compression Fracture -Case report-)

  • 신근만
    • The Korean Journal of Pain
    • /
    • 제13권2호
    • /
    • pp.237-241
    • /
    • 2000
  • Vertebral compression fractures commonly afflict the elderly. Some patients suffer from severe mechanical pain in spite of treatments with strong analgesics and bracing. Vertebroplasty, which was originally used for vertebral hemangioma, is effective for patients who do not respond to these more conservative treatments. However, the procedure has some risk. Leaks of bone cement into perineural tissues can be a serious complication. In contrast to the lumbar vertebrae, the outer margin of the pedicle of the thoracic vertebrae is almost in line with the outer margin of the body. This, combined with the thinner pedicle of the thoracic vertebrae, makes proper needle placement difficult. The posterolateral approach is preferred to the transpedicular approach in order to avoid the danger of destroying the inner cortex of the pedicle. But there can be a problems with the standard posterolateral approach. The rib can be broken, the pleura can be punctured. A new and safer approach is possible. Before penetrating the bone, the needle is positioned at the upper margin of the transverse process, 5 mm away from the pedicle. To achieve this positioning, the needle must puncture the skin 1~1.5 cm laterally and 3~5 mm cranially to the target point on the bone. This approach was used for 10 patients and we achieved good results with no serious complication.

  • PDF

Modified Trajectory of C2 Laminar Screw-Double Bicortical Purchase of the Inferiorly Crossing Screw

  • Rhee, Woo-Tack;You, Seung-Hoon;Jang, Yeon-Gyu;Lee, Sang-Youl
    • Journal of Korean Neurosurgical Society
    • /
    • 제43권2호
    • /
    • pp.119-122
    • /
    • 2008
  • The crossing laminar screw fixation might be the most recently developed approach among various fixation techniques for C2. The new construct has stability comparable to transarticular or transpedicular screw fixation without risk of vertebral artery injury. Quantitative anatomical studies about C2 vertebra suggest significant variation in the thickness of C2 lamina as well as cross sectional area of junction of lamina and spinous process. We present an elderly patient who underwent an occipito-cervical stabilization incorporating crossed C2 laminar screw fixation. We preoperatively recognized that she had low profiles of C2 lamina, and thus made a modification of trajectory for the inferiorly crossing screw. We introduce a simple modification of crossing C2 laminar screw technique to improve stability in patients with low laminar profiles.

Vertebroplasty Utilizing Percutaneous Vertebral Body Access (PVBA) Technique for Osteoporotic Vertebral Compression Fractures in the Middle Thoracic Vertebrae

  • Cho, Yong-Jun;Choi, Jong-Hun;Cho, Sung-Min
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권3호
    • /
    • pp.161-165
    • /
    • 2007
  • Objective : Percutaneous approach to the middle thoracic vertebra through the transpedicular route for the patients with osteoporotic vertebral compression fractures is difficult due to the small size of the pedicle and parasagittally oriented vertebra body anatomy. The percutaneous vertebral body access [PVBA] technique utilizing the posterolateral extrapedicular approach avoids the pedicle and provides direct access to the vertebral body. The objective of this study is to evaluate the efficacy of the vertebroplasty utilizing PVBA technique for osteoporotic vertebral compression fractures in the middle thoracic vertebrae. Methods : A retrospective review was done on 20 patients who underwent vertebroplasty utilizing PVBA technique performed for painful osteoporotic compression fracture in the middle thoracic vertebrae at 22 levels from May 2003 to June 2006. The average amount of the injected cement was 1.5-2.5ml. The postprocedural outcome was assessed using a visual analogue scale [VAS]. Results : The treated vertebrae were T5 [1 level], T6 [5 levels], 17 [7 levels], and T8 [9 levels]. The compression rate and kyphotic angle were improved after procedure from $18%{\pm}13.4$ to $16%{\pm}13.8$ [p > 0.05] and from $6.9^{\circ}{\pm}6.7$ to $6.6^{\circ}{\pm}6.2$ [p>005], respectively. Preprocedural VAS was $8.2{\pm}0.70$ and was decreased to $2.1{\pm}1.02$ [p < 0.01] after treatment. Postprocedural cement leakage was noted in 3 levels [13.7%]. There were no cases of leakage to epidural space or neural foramen, segmental artery injury, and pneumothorax. Conclusion : These results suggest that the complication rates are low and good results can be achieved with vertebroplasty utilizing PVBA technique for the osteoporotic vertebral compression fractures especially in the middle thoracic vertebrae.

Titanium Mesh Cage for Anterior Stabilization in Tuberculous Spondylitis : Is It Safe?

  • Bak, Koang-Hum;Cheong, Jin-Hwan;Kim, Jae-Min;Kim, Choong-Hyun;Kim, Seung-Bum
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권6호
    • /
    • pp.412-418
    • /
    • 2006
  • Objective : The safety of titanium metal cages in tuberculous spondylitis has not been investigated. We evaluated the outcome and complications of titanium mesh cages for reconstruction after thoracolumbar vertebrectomy in the tuberculous spondylitis. Methods : There were 17 patients with 18 operations on the tuberculous spondylitis in this study. Sixteen patients were operated with anterior corpectomy and reconstruction with titanium mesh cage followed by posterior transpedicular screw fixations on same day, two pateints were operated by either anterior or posterior approach only. After the affected vertebral body resection and pus drainage from the psoas muscle, titanium mesh cage, filled with morselized autogenous bone, was inserted. All the patients had antituberculosis medication for 18 months. The degree of kyphosis correction and the subsidence of cage were measured in the 15 patients available at a minimum of 2 years. Outcome was assessed with various cross-sectional outcome measures. Recurrent infection was identified by serial ESR[Erythrocyte Sedimentation Rate] and CRP[Cross Reactive Protein]. Results : There was no complication from the use of a titanium mesh cage. Recurrent infection was not detected in any case. Average preoperative of $9.2^{\circ}$ was reduced to $-2^{\circ}$ at immediate postoperative period, and on final follow up period kyphotic angle was measured to be $4.5^{\circ}$. Postoperatively, subsidence was detected in most patients especially at ambulation period, however further subsidence was prevented by the titanium mesh cage. Osseous union was identified in all cases at the final follow-up. Conclusion : The cylindrical mesh cage is a successful instrument in restoring and maintaining sagittal plane alignment without infection recurrence after vertebrectomy for tuberculous spondylitis.

골다공증을 동반한 척추체 압박골절에 대한 경피적 척추 성형술 - 예비보고 - (Percutaneous Vertebroplasty in the Treatment of Vertebral Body Compression Fracture with Osteoporosis - Preliminary Report -)

  • 이상구;유찬종
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권5호
    • /
    • pp.615-622
    • /
    • 2000
  • Objective : Percutaneous vertebroplasty is an effective and minimally invasive procedure consisting of the injection of a PMMA(polymethyl methacrylate) into the vertebral body compression fracture with osteoporosis. Matherials and Methods : Twenty-eight procedures were performed for vertebral body compression fractures with osteoporosis in 25 patients(22 women, 3 men). The mean age was 65.9 years old. The inclusion criteria for percutaneous vertebroplasty were 1) acute vertebral body compression fracture with osteoporosis, 2) expected high operative morbidity in old age, 3) no neurologic deficits, 4) no or minimal canal enchroachment, 5) patient refusal of invasive surgery. All patients underwent MR images before the procedure. Under local anesthesia, after the percutaneous needle puncture of the involved vertebra via a transpedicular approach and venography using the water soluble contrast material, PMMA injection was introduced into the fractured vertebral body. Results : The procedure was technically successful in all patients. All patients experienced excellent pain relief (complete pain relief ; 10, marked pain relief ; 14). One patient experienced marked pain relief, however, the patient died during the follow-up period due to stomach cancer. There were twelve paravertebral tissue leaks, twelve paravertebral venous plexus leaks, four epidural leaks and one intradiskal leak, but no clinically significant complications occurred in all patients. Conclusion : Percutaneous vertebraoplasty is a valuable procedure in the treatment of vertebral body compression fracture with osteoporosis, providing immediate pain relief and early mobilization. MRI is the most reliable diagnostic tool for identifying painful fractured vertebral body.

  • PDF

폴리메틸메타크리레이트를 사용한 경피적 척추성형술의 골다공증 척추체 압박골절에 대한 치료효과 : 예비보고 (Percutaneous Vertebroplasty with Polymethymethacrylate in the Treatment of Osteoporotic Vertebral Body Compression Fractures : Preliminary Report)

  • 박춘근;이관성;최영근;류경식;박춘근;조경석;강준기
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권3호
    • /
    • pp.365-371
    • /
    • 2000
  • Objectives : To describe a technique for percutaneous vertebroplasty of osteoporotic vertebral body compression fractures and to report preliminary results of its use. Methods : The technique was used over a 8-month period in 9 patients with 10 painful vertebral fractures. The technique involves percutaneous puncture of the involved vertebrae with a Jamshidi needle via a transpedicular approach followed by injection of polymethylmethacrylate(PMMA) into the vertebral body. Results : The procedure was technically successful in all patients, with an average injection amount of 5.9 cc per vertebral body. One patient complained of flank pain postoperatively in spite of improvement in back pain caused by the fractured vertebra. Remaining eight patients reported significant pain relief early after treatment. The patients were followed up for 3 to 15 months(average 7.2 months) and demonstrated no recurrence of pain or aggravation of deformity. Conclusion : Vertebroplasty appears to be a valuable tool in the treatment of painful osteoporotic vertebral fractures, providing acute pain relief and early mobilization in appropriate patients. However, it needs to have more extensive prospective clinical study to confirm its definitive role in the management of this condition.

  • PDF