• 제목/요약/키워드: transmission power

검색결과 5,780건 처리시간 0.075초

낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준 (Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation)

  • 우정욱;문재덕
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제55권12호
    • /
    • pp.555-560
    • /
    • 2006
  • As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To Protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.

An Architecture to Support Power Saving Transmission Services with Route Stability in Mobile Ad-hoc Wireless Networks

  • An, Beong-Ku;Kim, Nam-Soo
    • Journal of Ubiquitous Convergence Technology
    • /
    • 제1권1호
    • /
    • pp.35-41
    • /
    • 2007
  • In mobile ad-hoc wireless networks, one of the most important challenging issues is how to conserve energy, maximizing the lifetime of route(networks) in the view points of both power and mobility of nodes. However, many transmission methods presented in the previous works can not satisfy these two objectives simultaneously. To obtain these two goals, in this paper we propose an architecture to support power saving transmission services with route stability in mobile ad-hoc wireless networks. The proposed architecture consists of two parts, the underlying route stability method to support route(network) lifetime and the power saving transmission methods. The performance evaluation of the proposed architecture is achieved via simulation and analysis.

  • PDF

Integrated Optimization of Combined Generation and Transmission Expansion Planning Considering Bus Voltage Limits

  • Kim, Hyoungtae;Kim, Wook
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권4호
    • /
    • pp.1202-1209
    • /
    • 2014
  • A novel integrated optimization method is proposed to combine both generation and transmission line expansion problem considering bus voltage limit. Most of the existing researches on the combined generation and transmission expansion planning cannot consider bus voltages and reactive power flow limits because they are mostly based on the DC power flow model. In this paper the AC power flow model and nonlinear constraints related to reactive power are simplified and modified to improve the computation time and convergence. The proposed method has been successfully applied to Garver's six-bus system which is one of the most frequently used small scale sample systems to verify the transmission expansion method.

전기유변성 클러치의 동력전달 메커니즘 제1보: 동력전달 메커니즘의 해석적 전개 (Power Transmission Mechanism of Electrorheological Clutch Part I: Analytical development of power transmission mechanism)

  • 이규한;심현해;김창호;임윤철
    • Tribology and Lubricants
    • /
    • 제13권2호
    • /
    • pp.27-38
    • /
    • 1997
  • ER clutch is a device using ER fluid, so called "intelligent material" and is a power transmission system controlled with electric field strength. This device responses very rapidly when controlled by rapid and continuous electrical signal and can form a servosystem. Wear, noise and vibration during operation is very low level. This study was undertaken to investigate substitutive possibilities of this ER clutch for existing power transmission mechanism. An analytic relationships using rheological model (so called, 'Bingham plastic model') of ER fluid were developed, and operation constraints and optimum design concepts were constructed. With this relationships, typical responses of ER clutch and effects of changing geometric, kinetic parameters of ER clutch and ER fluid properties were described. In conclusion, compared with existing mechanisms, an excellent performance of ER clutch was confirmed.confirmed.

경쟁적 전력시장에서 혼잡을 고려한 송전설비계획 기준설정에 관한 연구 (A Study on a Criterion of Transmission Planning in a Competitive Electricity Market)

  • 김종만;한석만;김발호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제54권7호
    • /
    • pp.358-365
    • /
    • 2005
  • Transmission networks play an important role which transfer generated electric power to a consumer in power system operation. In a competitive environment of electric power industry, developing the technological criterions and methodologies on transmission planning is becoming new challenge to transmission system planner. The use of a locational signal and the provision of a indicative plan to control the transmission investment reasonably is very important in the viewpoint of a regulator. The main target of this study is to develop a systematic criterion of transmission expansion planning. And system congestion cost is considered. The proposed methodology was demonstrated with several case studies.

동적 특성을 고려한 자동변속기의 모델링 (Dynamically-Correct Automatic Transmission Modeling)

  • 김정호;조동일
    • 한국자동차공학회논문집
    • /
    • 제5권5호
    • /
    • pp.73-85
    • /
    • 1997
  • An automatic transmission is an important element of automotive power systems that allows a driving convenience. Compared to a manual transmission, however, it has a few problems in efficiency, shift feel, and maintenance. To improve these, it is imperative to understand the dynamics of automatic transmissions. This paper develops a dynamically-correct model of an automatic transmission, using the bond graph method. The bond graph method is ideally suited for modeling power systems, because the method is based on generalized power variables. The bond graph method is capable of providing correct dynamic constraints and kinematic constraints, as well as the governing differential equations of motion. The bond graph method is applied to 1-4 in-gear ranges, as well as various upshifts and downshifts of an automatic transmission, which allows an accurate simulation of an automatic transmission. Conventional automatic transmission models have no dynamic constraint, which do not allow correct simulation studies.

  • PDF

이중 특성 임피던스 전송 선로를 이용한 전력 전송 또는 전력 분배가 가능한 회로 설계 (The circuit design to be power transmission or power distribution using the dual characteristic impedance transmission line)

  • 박웅희
    • 한국정보통신학회논문지
    • /
    • 제18권10호
    • /
    • pp.2339-2344
    • /
    • 2014
  • 마이크로스트립 선로 형태의 전송선로 밑면에 플로팅 동판을 위치시키면 플로팅 동판과 접지면 사이의 단락 또는 개방 연결에 따라 전송선로는 마이크로스트립 선로 또는 코플라나 선로 형태로 동작하게 된다. 이러한 동작은 하나의 전송 선로 폭에 대해 서로 다른 두 개의 특성 임피던스를 가질 수 있음을 의미한다. 플로팅 동판이 존재하는 마이크로스트립 전송 선로를 이용하여 안정적인 입력 정합 상태를 가지며 조건에 따라 단순히 신호를 전달하는 2-단자 전력 전송 선로 또는 전력 분배가 가능한 2-way 전력 분배 회로로 동작할 수 있는 가변 전송선로를 제안 및 제작하였다. 제안된 회로는 코플라나 선로로 동작하는 경우에는 전력 전송 선로로 동작하고, 마이크로스트립 선로로 동작하는 경우에는 2-way 전력 분배 회로로 동작한다. 제작된 가변 전송 선로는 700 MHz 이상의 주파수에서 전력 전송 선로로 동작하는 경우 -0.2 dB 이내의 전달 손실($S_{21}$)과 -15 dB 이하의 반사 계수($S_{11}$)를 보였으며, 전력 분배 선로로 동작하는 경우에는 -10 dB 이하의 반사 계수($S_{11}$), -3.8 dB이내의 전달 손실($S_{21}$ or $S_{31}$), ${\pm}0.3dB$이내의 출력 전력차($S_{21}/S_{31}$)를 보였다.

동적 구속조건을 적용한 자동변속장치의 효과적인 시뮬레이션방법에 관한 연구 (A study on the efficient simulation methods for an automatic power transmission system applying dynamic torque constraint)

  • 정헌술;이교일
    • 대한기계학회논문집A
    • /
    • 제22권3호
    • /
    • pp.504-518
    • /
    • 1998
  • Degree-Of-Freedom(DOF) for most power transmission system varies according to the operation status which consists of friction elements to change the power flow or to adjust the speed ratio such as clutches, brakes or one-way clutches. To simulate the dynamic characteristics of automatic power transmission system which is a typical example of such a variable DOF systems, many sets of governing equations and complicated phase decision routines are necessary. In this paper dynamic constraint theorem is derived explaining the torque transmission characteristics during the clutch engagement process and a robust stable algorithm is developed describing this phase transition phenomenon effectively by introducing the concept of direct torque and virtual damping. Finally, applying this algorithm to a passenger car automatic transmission gear consisting of several friction elements, an efficient simulation methods for such a complex system will be suggested that is very simple and systematic.

Various Factors Influencing the Lifetime of Suspension-Type Porcelain Insulators for 154 kV Power Transmission Lines

  • Choi, In Hyuk;Park, Joon Young;Kim, Tae Gyun;Yoon, Yong Beum;Yi, Junsin
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권3호
    • /
    • pp.151-154
    • /
    • 2017
  • In this article, we investigated the various influencing factors that degraded the lifetime of suspension insulators in 154 kV transmission lines, and showed the possible solutions to avoid such breakdowns. With respect to achieve safety, reliability and aesthetical considerations, the characteristics of transmission and distribution network power cables should be improved. Suspension insulators are particularly important to study, as they have developed to be the main component of transmission lines due to their ability to withstand the electrical conductivity of high-voltage power transmission. Suspension insulators are mostly made from glass, rubber and ceramic material due to their high resistivity. In Korea, porcelain suspension insulators are typically used in the transmission line system, as they are cheaper and more flexible compared to other types of insulators. This is effective from preventing very high and steep lightening impulse voltages from causing the breakdown of suspension insulators used in power lines. Other influential factors affect the lifetime of suspension insulators that we studied include temperature, water moisture, contamination, mechanical vibration and electrical stress.

근거리 무선 전력 전송을 위한 평형 증폭기 구조의 10MHz 10W급 전력원 설계 (Design of the 10MHz and 10W Power Source for Short Distance Wireless Power Transmission)

  • 박동훈;김귀성;임은천;박혜미;이문규
    • 전기학회논문지
    • /
    • 제61권3호
    • /
    • pp.437-441
    • /
    • 2012
  • In this paper, we have designed and manufactured 10MHz power source for the application of short distance wireless power transmission. The designed power source consists of a DDS(direct digital synthesizer) signal generator, a buffer driver and a balanced power amplifier. Short range wireless power transmission is usually carried out by near-field inductive coupling between source and load. The distance variation between source and load gives rise to the change of load impedance of power amplifier, which has effect on the operation of power amplifier. To overcome this problem due to load variation of power amplifier, we have adopted the balanced power amplifier using the quadrature hybrid implemented by lumped capacitors and a mutually coupled coil. The experiment results show the above 40dBm output power, frequency range of 9 to 11MHz, and total DC power consumption of 36W.