• 제목/요약/키워드: transmission lines

검색결과 1,304건 처리시간 0.055초

고속 디지털 신호 전송선로에서의 Crosstalk 에 관한 연구 (A Study on Crosstalk in High Speed Digital Signal Transmission Line)

  • 김세영;장상건;남상식;박항구;신연강
    • 전자공학회논문지A
    • /
    • 제31A권8호
    • /
    • pp.16-25
    • /
    • 1994
  • The prediction of crosstalk in one of important problems in estimating the EMC of a system for high speed digital signal transmission. Crosstalk curves are shown in terms of characteristic impedance of lines spacing between lines and rise time of pulse by using general multiple coupled transmission line equation and harmonic-balance method. The coupled symmetrical two-line on dielectric material epoxy-glass FR 4(${\varepsilon}_r$), is fabricated to measure crosstalk occuring at the near end and far end of the passive line. The inter-line is inserted to reduce crosstalk between two microstrip lines. The simulation results and the measurement results are shown and found to be very close.

  • PDF

Helical gear multi-contact tooth mesh load analysis with flexible bearings and shafts

  • Li, Chengwu;He, Yulin;Ning, Xianxiong
    • Structural Engineering and Mechanics
    • /
    • 제55권4호
    • /
    • pp.839-856
    • /
    • 2015
  • A multi-contact tooth meshing model for helical gear pairs considering bearing and shaft deformations is proposed. First, to easily incorporate into the system model, the complicated Harris' bearing force-displacement relationship is simplified applying a linear least square curve fit. Then, effects of shaft and bearing flexibilities on the helical gear meshing behavior are implemented through transformation matrices which contain the helical gear orientation and spatial displacement under loads. Finally, true contact lines between conjugated teeth are approximated applying a modified meshing equation that includes the influence of tooth flank displacement on the tooth contact induced by shaft and bearing displacements. Based on the model, the bearing's force-displacement relation is examined, and the effects of shaft deformation and external load on the multi-contact tooth mesh load distribution are also analyzed. The advantage of this work is, unlike previous works to search true contact lines through time-consuming iterative strategy, to determine true contact lines between conjugated teeth directly with presentation of deformations of bearings and shafts.

화염으로 인한 전기적 섬락특성 변화 (A Flashover Characteristics Due to Flames)

  • 손홍관;이형권;한형주;박인표;오한호;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.703-704
    • /
    • 2007
  • Most of the transmission lines in Korea pass through a mountains. The forest fire occurred in around the transmission lines make an accident such as flashover and faults in the power transmission lines. In spite of that risk, there are no research on the flashover characteristics by fires in electric discharge engineering in our country. This paper was mentioned about the relation between the flame and flashover characteristics. We were carried out simple test by using artificial flame generator and rod-plane or conductor-plane gaps. And we were summarized test results.

  • PDF

노후 송전선로의 가공송전선 직선 슬리브 분석 연구 (The Study on Aged Sleeves for Old Transmission Lines)

  • 김병걸;김상수;안상현;손홍관;박인표;장태인
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.538-540
    • /
    • 2007
  • A detailed study on aged sleeves for old transmission lines was carried out to clarify the deterioration of sleeves and the condition of installation. A lot of removed aged sleeves from transmission lines were investigated. Many biased installed cases and corrosion of steel sleeve part were found. These defects can cause a serious accident such as blackout during operating. The detailed results were presented in the text.

  • PDF

765kV 비연가 송전선로에서 단상지락고장 시어 거리개전 알고리즘 (A New Distance Relaying Algorithm for Phase-to-Ground Fault in 765kV Untransposed Transmission Lines)

  • 안용진;강상희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.452-454
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-ground fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for Phase-to-ground fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kV untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

765kV 비연가 송전선로에서 상간단락고장 시어 거리계전 알고리즘 (A New Distance Relaying Algorithm for Phase-to-Phase Short Fault in 765kV Untransposed Transmission Lines)

  • 안용진;강상회
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.455-457
    • /
    • 2004
  • An accurate digital distance relaying algorithm which is immune to reactance effect of the fault resistance and the load current for phase-to-phase short fault in 765kV untransposed transmission lines is proposed. The algorithm can estimate adaptively the impedance to a fault point independent of the fault resistance. To compensate the magnitude and phase of the apparent impedance, this algorithm uses the angle of an impedance deviation vector. The impedance correction algorithm for phase-to-phase short fault uses a voltage equation at fault point to compensate the fault current at fault point. A series of tests using EMTP output data in a 765kv untransposed transmission lines have proved the accuracy and effectiveness of the proposed algorithm.

  • PDF

가공송전선 유도장해 특성을 고려한 최적 상배열 연구 (Study on Optimal Phase Arrangement Considering the Characteristics of Inductive Interference from Overhead Transmission Lines)

  • 강경두;김진규
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.13-18
    • /
    • 2019
  • The domestic overhead transmission lines use a vertical configuration and reverse phase arrangement, but when there is a limitation in steel tower height because the transmission lines pass a height limit zone or special zone, an application of triangular arrangement is necessary, and a study on the optimal phase arrangement to minimize inductive interference for this is necessary. If conductor arrangement are changed, the action of electrostatic induction and electromagnetic induction becomes different from before changes, so the changed conductor arrangement should be reviewed in terms of inductive interference. So this paper presents an optimal phase arrangement to reduce inductive interference by calculating electrostatic induction and electromagnetic induction according to conductor arrangement.

CPW와 Offset 결합 전송선로를 이용한 비대칭 다단 분배기 (Unequal Multi-Section Power Divider using CPW and Offset Coupled Transmission Lines)

  • 최종운;윤영철;성규제;김영
    • 한국항행학회논문지
    • /
    • 제23권4호
    • /
    • pp.309-315
    • /
    • 2019
  • 본 논문은 1:3과 1:4 분배 비율을 갖는 비대칭 분배기를 CPW와 offset 결합 전송선로를 이용하여 다단 구조로 구현한 것이다. 이 분배기는 다단 구조의 전송선로와 캐패시터와 저항이 병렬로 연결된 회로로 구성되어 있다. 다단 전송선로는 임의의 임피던스로 종단된 ${\lambda}/4$ 단일 전송선로를 분해하여 그것을 $90^{\circ}$ 전기적 길이보다 짧은 다단 전송선로로 정합시키는 방법으로 구현하였고, RC 병렬회로는 출력 포트의 반사계수와 출력 포트 사이의 고립 특성을 얻기 위해서 전송선로 사이에 연결하였다. 이러한 방법으로 2 GHz에서 설계된 전력분배기는 각 단의 전송선로는 ${\lambda}/4$보다 짧게 구현되어 기존 것 보다 최소 27% 작게 구현하였고, 광 대역 특성을 얻을 수 있음을 확인하였다.

가공송전선의 송전용량을 증가시키기 위한 동적송전용량 시스템의 설계 (A Design for Dynamic Line Rating System to increase Overhead Transmission Line Capacities)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.72-77
    • /
    • 2011
  • Dynamic Line Rating (DLR) techniques have been greatly worthy of notice for efficiently increasing transmission capacity as well as controlling load-flow in overhead transmission lines, in comparison with the existing power system operating with Static Line Rating (SLR). This paper describes an utilization method to implement DLR control system for old transmission lines built in the first stage using the ground clearance design standard with lower dips. The suggested DLR system is focused on designing as temperature control system rather than current/load control system. Based on several performance for conductor temperatures, it is shown that DLR system with efficiency can be implemented.

한전 765kV 송전선로 확충계획의 확률론적 신뢰도 평가 (Probabilistic Reliability Evaluation for 765kV Transmission Lines of KEPCO Grid Expansion Planning)

  • 트란트룽틴;권중지;최재석;전동훈;한경남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.237-239
    • /
    • 2005
  • The importance and necessity conducting studies on grid reliability evaluation have been increasingly important in recent years due to the number of black-out events occurring through in the world. Quantity evaluation of transmission system reliability is very important in a competitive electricity environment. The reason is that the successful operation of electric power under a deregulated electricity market depends on transmission system reliability management. Also in Korea it takes places. This paper presents the probabilistic reliability evaluation for 765KV transmission lines of KEPCO grid expansion planning. The Transmission Reliability Evaluation for large-Scale Systems (TRElSS) Version 6.2, a software package developed by Electric Power Research Institute (EPRI) is utilized in determining the improved probabilistic reliability indices of (KEPCO) system.

  • PDF