• Title/Summary/Keyword: transmission line parameters

Search Result 289, Processing Time 0.024 seconds

Unifying calculation of vortex-induced vibrations of overhead conductors

  • Leblond, Andre;Hardy, Claude
    • Wind and Structures
    • /
    • v.8 no.2
    • /
    • pp.79-88
    • /
    • 2005
  • This paper deals with a unified way for calculating vortex-induced vibrations (Aeolian vibrations in transmission line parlance) of undamped single overhead conductors. The main objective of the paper is to identify reduced parameters which would unify the predicted vibration response to the largest possible extent. This is actually done by means of a simple mathematical transformation resulting, for a given terrain (associated to a given wind turbulence intensity), into a single, unified response curve that is applicable to any single multi-layered aluminium conductor. In order to further validate the above process, the predicted, unified response curve is compared with measured response curves drawn from tests run on a full-scale test line using several aluminium-conductor-steel-reinforced (ACSR), all-alloy-aluminium-conductor (AAAC) and aluminium-conductor-alloy-reinforced (ACAR) conductors strung at different tensions. On account of the expected scatter in the results from such field tests, the agreement is shown to be good. The final results are expressed by means of only four different curves pertaining to four different terrain characteristics. These curves may then be used to assess the vibration response of any undamped single, multi-layer aluminium conductor of any diameter, strung at any practical tension.

Design for Minimizing Transmission Loss of Broadband Right-Angle Coaxial-to-Microstrip Transition (광대역 동축-마이크로스트립 수직 트랜지션의 전송 손실 저감 설계)

  • Kim, Sei-Yoon;Roh, Jin-Eep;Chung, Ji-Young;Ahn, Bierng-Chearl;You, Young-Gap
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1040-1049
    • /
    • 2006
  • A design method for minimizing transmission loss of a broadband right-angle transition from a coaxial cable to a microstrip line is presented. The right-angle transition has been widely used where printed circuit applications need to be fed from behind the ground plane using coaxial line. To obtain the minimized transmission loss over the whole operating frequency range of the transition, design parameters such as ground aperture and probe diameters, ground aperture offset, and stub length are optimized using a commercial electromagnetic simulation software. Results are presented for the optimum right-angle transition from an SMA connector to a microstrip line on common reinforced 0.787 mm thick PTFE substrates. Measurements of a fabricated transition show that reflection coefficient is less than -22 dB and insertion loss is less than 0.45 dB over $0.05{\sim}20GHz$.

Design of High-Speed Multi-Layer PCB for Ultra High Definition Video Signals (UHD급 영상구현을 위한 다층인쇄회로기판의 특성 임피던스 분석에 관한 연구)

  • Jin, Jong-Ho;Son, Hui-Bae;Rhee, Young-Chul
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1639-1645
    • /
    • 2015
  • In UHD high-speed video transmission system, when a signal within certain frequency region coincides electrically and structurally, the system becomes unstable because the energy is concentrated, and signal flux is interfered and distorted. For the instability, power integrity analysis should be conducted. To remove the signal distortion for MLB, using a high-frequency design technique for EMI phenomenon, EMI which radiates electromagnetic energy fluxed into power layer was analyzed considering system stabilization. In this paper, we proposed an adaptive MLB design method which minimizes high-frequency noise in MLB structure, enhances signal integrity and power integrity, and suppresses EMI. The characteristic impedance for multi-layer circuit board proposed in this study were High-Speed Video Differential Signaling(HSVDS) line width w = 0.203, line gap d = 0.203, beta layer height h = 0.145, line thickness t = 0.0175, dielectric constant εr = 4.3, and characteristic impedance Zdiff = 100.186Ω. When high-speed video differential signal interface board was tested with optimized parameters, the magnitude of Eye diagram output was 672mV, jittering was 6.593ps, transmission frequency was 1.322GHz, signal to noise was 29.62dB showing transmission quality improvement of 10dB compared to previous system.

On the Current Limiting Characteristics and Parameters of Superconducting Fault Current Limiter Introduced to 345kV Electric Power System due to Resistive-Type, Reactive-Type (유도형과 저항형 초전도한류기의 파라메타를 고려한 전력계통도입효과의 분석 및 고찰)

  • 홍원표;김용학;전영환;이승학
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.285-290
    • /
    • 2002
  • Power systems are becoming larger and larger for meeting electric power demand. Therefore, the over-currents resulting from contingencies such short circuits are increasing higher. The Maximum short circuit current of modern power system is becoming so large that circuit breaker are not expected th be able to shut down the current in the future. In order to cut over-currents, a system composed of a superconducting fault current limiter(SFCL) and traditional breaker seems to provide a promising solution for future power operation. In present paper, three line-to-ground fault is assumed to happen at the center of 345kV transmission lines in a large capacity electric power system The superconducting fault current limiter was represented using a commutation type, which consists of a non-inductive superconducting coil and current limiting element(resistor or reactor). The introduction merits of the SFCL were investigated quantitatively by RTDS/EMTDC from the viewpoint of current limiting performance, the prevention of the voltage drop at the load bus and comparison characteristics for two type SFCL. Desired design specification and operation parameters of SFCL were also given qualitatively by the performance evaluation of the two type SFCL in the power system.

  • PDF

An Analytic Method for Measuring Accurate Fundamental Frequency Components (기본파 성분의 정확한 측정을 위한 해석적 방법)

  • Nam, Sun-Yeol;Gang, Sang-Hui;Park, Jong-Geun
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.4
    • /
    • pp.175-182
    • /
    • 2002
  • This paper proposes an analytic method for measuring the accurate fundamental frequency component of a fault current signal distorted with a DC-offset, a characteristic frequency component, and harmonics. The proposed algorithm is composed of four stages: sine filer, linear filter, Prony's method, and measurement. The sine filter and the linear filter eliminate harmonics and the fundamental frequency component, respectively. Then Prony's method is used to estimate the parameters of the DC-offset and the characteristic frequency component. Finally, the fundamental frequency component is measured by compensating the sine-filtered signal with the estimated parameters. The performance evaluation of the proposed method is presented for a-phase to around faults on a 345 kV 200 km overhead transmission line. The EMTP is used to generate fault current signals under different fault locations and fault inception angles. It is shown that the analytic method accurately measures the fundamental frequency component regardless of the characteristic frequency component as well as the DC-offset.

Scattering of Oblique Waves by an Inanite Flexible Membrane Breakwater (유연막 방파제에 의한 경사파의 산란)

  • 조일형;홍석원
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.7 no.3
    • /
    • pp.219-226
    • /
    • 1995
  • The wave interaction with flexible membrane such as PVC and PU fabrics is studied to prove its applicability to portable breakwaters. To analyze the wave deformation due to the flexible membrane. eigen-function expansion method is employed. The fluid domain is seperated into two regions. The velocity potential in each regions and the deformation of membrane are coupled by the body boundary conditions. Herein the deformation of membrane is obtained by solving the membrane equation. As a numerical example, transmission and reflection coefficients according to the change of several design parameters such as tensile force. mooring line stiffness and membrane height are investigated. It is found that the efficiency of flexible membrane breakwater is significantly affected by these design parameters. The angle of incident wave is an important role to the performance of breakwater. Finally we conclude that flexible membrane can be used to engineering material for the future breakwaters.

  • PDF

Extraction of Design Parameters for Re-entrant Mode Microstrip Directional Coupler with High Directivity Using FE Calculation (유한요소계산을 이용한 고지향성을 갖는 재-진입모드 마이크로스트립 방향성 결합기의 설계 파라미터 추출)

  • Kim, Hyeong-Seok;Park, Jun-Seok;Ahn, Dal
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.5
    • /
    • pp.238-242
    • /
    • 2001
  • In this paper, we extracted design parameters for re-entrant mode microstrip directional coupler using FE(finite element) calculations. The microstrip directional coupler suffers from a poor directivity due to effect of the inhomogeneous dielectric including both dielectric substrate and air in microstrip transmission lines. Thus, the phase velocity of even mode is not equal to that of odd mode. In order to improve the directivity of microstrip directional coupler, a novel re-entrant mode microstrip directional coupler was employed. In microstrip configuration, the high directivity can be reached by matching the even- and odd-mode effective phase velocities. Through the values of capacitance obtained from 2-dimensional FE calculations, the phase velocities for each mode and the design parameter were extracted for the proposed parallel coupled-line configuration. Based on the extracted design parameter with phase matching condition, we designed and fabricated a 30dB directional coupler at 0.85GHz. Experimental results show good performance with excellent, isolation and directivity.

  • PDF

A study for the extraction of DGS 4-port equivalent circuit and it's parameters (DGS 구조의 4-port 등가회로 및 파라미터에 대한 추출 방법에 대한 연구)

  • Son, Chang-Sin;Jeong, Myung-Sub;Choi, Wan-Seoung;Park, Jun-Seok;Lim, Jae-Bong;Choi, Hong-Goo
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2043-2045
    • /
    • 2004
  • This thesis complemented the weak points that the existing theses did not represented a phase characteristic as the equivalent circuit by applying 4-port simulation to DGS (Defected Ground Structure) characteristic and an equivalent circuit, which are the transmission line structure that has the defect made in the ground surface. We used a distribute device and a lumped device, obtained the equivalent circuit by applying the structure of balun to a discontinuous part. An indicated DGS (Defected Ground structure) is a dumbbells-shaped single defect, we indicated satisfying a magnitude and phase characteristics by applying this equivalent circuit.

  • PDF

Analysis of the Equivalent Circuits of the )-Dimensional Stepped Discontinuity in Microstrip Lines (계단형 3차원 구조를 갖는 마이크로스트립 선로의 등가회로 해석)

  • 윤현보;임계재
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.4
    • /
    • pp.401-406
    • /
    • 2002
  • A microstrip circuit with multilayer structure is applied variously in the MMIC. For effective transmission between microstrip lines with different dielectric height, it is need to analyze and to induce accurately the equivalent circuit in 3 dimensional stepped discontinuous microstrip line. In this paper, by using the S parameters obtained by FDTD numerical method and measurement, T equivalent circuit and its element values were induced. And the analyzed and measured results showed good agreement in 1 ∼5 ㎓ range.

Derivation of A,B,C,D Parameters of Long Transmission Line Using T-model and Hyperbolic Function (T-모델과 쌍곡선함수를 이용한 장거리 송전선로의 A,B,C,D 파라미터 유도)

  • Kim, Do-Won;Lee, Sang-Joong;Yang, Seong-Deog
    • Proceedings of the KIEE Conference
    • /
    • 2008.11a
    • /
    • pp.53-55
    • /
    • 2008
  • 본 논문에서는, 기존의 문헌에 사용되어 온 $\Gamma$형을 대체할 수 있는 새로운 T형 장거리 송전선로 모델을 제시한다. 특히, T-모델은 선로 양단의 병렬 어드미턴스와의 중복이 없다. 또한, 기존 문헌에 제시된 hyperbolic solution을 이용한 간단한 장거리 송전선로 A,B,C,D 파라미터 유도방법을 소개한다. hyperbolic solution으로 장거리 송전선로 파라미터를 유도할 경우, exponential solution보다 수식의 양을 줄일 수 있고, 초기값도 간단하게 구할 수 있다.

  • PDF