• 제목/요약/키워드: transmission line parameters

검색결과 289건 처리시간 0.025초

자화된 페라이트 기판상의 다중 결합 마이크로스트립 선로 해석 (Analysis of multiple coupled microstrip lines on a magnetized ferrite substrate)

  • 문영찬;윤상원;창익수
    • 전자공학회논문지A
    • /
    • 제33A권5호
    • /
    • pp.65-74
    • /
    • 1996
  • in this paper, the propagation characteristics of the dominant modes in multiple coupled microstrip lines on a magnetized ferrite substrate are analyzed. The propagation constants and characteristic impedances are calculated by using the spectral domain method. With the numerical results, multi-port impedance parameters as well as scattering parameters are derived from nonreciprocal transmission line equations which are consistent with conventional transmission line theory. In additon, the numerical resutls of nonreciprocal characteristics for various values of structural, material parameters, and external magnetic fields are also presented.

  • PDF

무손실 전송선로를 가진 카오스 회로에서의 카오스 동기화 (Chaos Synchronization with Lossless Transmission Line of Chaos Circuit)

  • 배영철
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 1999년도 추계종합학술대회
    • /
    • pp.501-504
    • /
    • 1999
  • Chua's circuit is a simple electronic network which exhibits a variety of bifurcation and attractors. The circuit consists of two capacitors, an inductor, a linear resistor, and a nonlinear resistor. In this paper, a transmitter and a receiver using two identical Chua's circuits are proposed and a synchronizations of lossless transmission line are investigated. Since the synchronization of the transmission system is impossible by coupled synchronization, the drive-response synchronization theory were used. As a result, the chaos synchronization has delay characteristics in the lossless transmission system caused by the line parameters L and C.

  • PDF

Transformer Winding Modeling based on Multi-Conductor Transmission Line Model for Partial Discharge Study

  • Hosseini, Seyed Mohammad Hassan;Baravati, Peyman Rezaei
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.154-161
    • /
    • 2014
  • To study and locate partial discharge(PD) and analyze the transient state of power transformer, there is a need for a high frequency model of transformer winding and calculation of its parameters. Due to the high frequency nature of partial discharge phenomenon, there is a need for an accurate model for this frequency range. To attain this goal, a Multi-Conductor Transmission Line (MTL) model is used in this paper for modeling this transformer winding. In order that the MTL model can properly simulate the transformer behavior within a frequency range it is required that its parameters be accurately calculated. In this paper, all the basic parameters of this model are calculated by the use of Finite Element Method (FEM) for a 20kV winding of a distribution transformer. The comparison of the results obtained from this model with the obtained shape of the waves by the application of PD pulse to the winding in laboratory environment shows the validity and accuracy of this model.

기체 전달 관로에 있어서 압력 전파의 주파수 응답에 대한 부하 임피던스의 영향 (The Effect of Load Impedances on the Frequency Response of Pressure Propagation in the Pneumatic Transmission Line)

  • 윤선주;손병진
    • 설비공학논문집
    • /
    • 제6권4호
    • /
    • pp.344-353
    • /
    • 1994
  • This study numerically analyzed the dynamic characteristics of the frequency response on the pneumatic transmission line with load impedances. The pressure transfer function is represented by the distributed parameter line model. To validate the mathematical approximations of Bessel function ratios, the results of frequency response in a blocked line were compared with those obtained by the Infinite-product, Brown's and Square-root approximations. Special emphasis was given to the frequency response characteristics on the pneumatic transmission line with load impedances. Computations were carried out for the wide range of parameters in terms of load capacitance ratio and load resistance ratio. The present results indicated that the theoretical model is capable of accurately predicting the frequency response characteristics for any configuration of a fluid transmission line.

  • PDF

다양한 매질내의 손실특성 개선을 위한 크로스바 구조의 대칭 결합선로에 대한 해석 (Analysis of Symmetric Coupled Line with Crossbar Embedded Structure for Improved Attenuation Characteristics on the Various Lossy Media)

  • 김윤석
    • 대한전자공학회논문지TC
    • /
    • 제47권8호
    • /
    • pp.61-67
    • /
    • 2010
  • 일반적으로 MIS(도체-부도체-반도체)의 다층 구조로 이루어진 대칭 결합선로에 대한 해석 절차는 모드(even and odd) 해석에 기초한 특성임피던스와 전파상수를 추출함으로서 단층의 결합선로 해석 절차와 동일하다. 본 논문에서는 손실매질의 다층구조로 이루어진 마이크로 스트립선로의 손실특성의 개선을 위한 새로운 구조를 제안한다. MIS 구조로 된 전송선로의 Si와 SiO2층 사이에 0전위를 가진 도체를 일정한 간격의 주기적인 배열로 고안된 새로운 모델의 MIS구조에 대한 유한차분법을 이용한 해석방법이 사용된다. 특히 전송선로에 대한 유전체의 영향을 줄이기 위하여 0전위를 가진 주기적인 결합의 도체로 이루어진 구조가 시간영역의 신호를 통해 시험된다. 다양한 손실률을 가진 불완전 유전체에 따른 주파수 의존적인 추출된 전송선로 파라미터와 등가회로 파라미터가 주파수 함수로서 나타내진다. 특히 본 논문에서 제안한 새로운 구조의 불완전 유전체에 대한 전송선로 파라미터가 주파수 함수로 구해진다.

Analysis on Ampacity of Overhead Transmission Lines Being Operated

  • Yan, Zhijie;Wang, Yanling;Liang, Likai
    • Journal of Information Processing Systems
    • /
    • 제13권5호
    • /
    • pp.1358-1371
    • /
    • 2017
  • Dynamic thermal rating (DTR) system is an effective method to improve the capacity of existing overhead line. According to the methodology based on CIGRE (International Council on Large Electric systems) standard, ampacity values under steady-state heating balance can be calculated from ambient environmental conditions. In this study, simulation analysis of relations between parameters and ampacity is described as functional dependence, which can provide an effective basis for the design and research of overhead transmission lines. The simulation of ampacity variation in different rating scales is described in this paper, which are determined from real-time meteorological data and conductor state parameters. To test the performance of DTR in different rating scales, capacity improvement and risk level are presented. And the experimental results show that the capacity of transmission line by using DTR has significant improvement, with low probability of risk. The information of this study has an important reference value to the operation management of power grid.

Longitudinal reaction on conductors due to tornado wind load

  • Dingyu Yao;Ashraf El Damatty
    • Wind and Structures
    • /
    • 제38권4호
    • /
    • pp.325-339
    • /
    • 2024
  • The longitudinal force resulting from tornado loads on transmission line is considered a crucial factor contributing to the failure of transmission line structures during tornado events. Accurate estimation of this longitudinal force poses a challenge for structural designers. Therefore, the objective of this paper is to provide a set of charts that can be easily used to estimate the peak longitudinal forces transferred from the conductors to a tower. The critical wind field and corresponding configuration considered in this paper are previously studied and determined. The charts should account for all the conductor parameters that can affect the value of the longitudinal force. In order to achieve that, a parametric study is first conducted to assess the variation of the longitudinal forces with different conductor parameters, based on the critical tornado configuration. Results of this parametric study are used to develop the charts that can be used to calculate longitudinal forces by adopting a multi-variable line regression. The forces calculated from charts are validated by finite element analysis. An example for the usage of the charts is provided at the end of this paper.

DGS 전송선로의 등가회로와 전파지연계수에 대한 재고찰 (A Study for the Equivalent Circuit and Slow-Wave Factor of Defected Ground Structure Transmission Line)

  • 임종식;구자경;한상민;정용채;안달
    • 전기학회논문지
    • /
    • 제57권11호
    • /
    • pp.2041-2046
    • /
    • 2008
  • A frequency-dependent slow-wave factor (SWF) and equivalent circuit model of transmission line with defected ground structures (DGS) is described. Once S-parameters of a DGS transmission line are given, the conventional frequency -independent equivalent circuit elements are extracted using 3dB cutoff and resonant frequencies (Fc and Fo) as the first step. Using the initial equivalent elements and simple transmission line theories, a frequency-dependent equivalent transmission line model is established through an analytical method, and finally the frequency dependent SWF is calculated. The proposed equivalent circuit model and SWF are frequency-dependent and more reliable because even small insertion loss within available passband is considered, while they have been independent of frequency.

다층 다도체 선로로 구성된 회로의 펄스전송 특성 (Pulse Propagation Characteristics of Multilayer-Multiconcuctor Transmission Line Network)

  • 장행종;임영석
    • 전자공학회논문지A
    • /
    • 제31A권10호
    • /
    • pp.39-47
    • /
    • 1994
  • In this paper, by modeling the Multilayer-Multiconductor Transmission Line(MMTL) with the characteristic parameters-effective dielectric constant, eigen modal voltages, characteristic impedances at each mode, pulse propagation characteristics of MMTL network are simulated. Transmission line modelling is performed in frequency domain, then time domain resposes are obtained by transforming the frequency domain response using fast Fourier transform.

  • PDF

CPW 구조를 이용한 metamaterial 전송선로 특성에 관한 연구 (A study of metamaterial transmission line characteristics using CPW structure)

  • 김진수;황희용
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.251-255
    • /
    • 2008
  • Metamaterial are artificial structures that can be designed to exhibit specific electromagnetic properties not commonly found in nature. Metamaterial transmission lines are usually fabricated with a microstrip structure and it's equivalent circuit is composed of two series capacitances and a shunt inductance. However microstrip structure need a via hall for realizing a shunt inductance. To eliminate via hall, we proposed a CRLH transmission line using a CPW structure, and obtained equivalent circuit values, line parameters.

  • PDF